SciELO - Scientific Electronic Library Online

 
vol.90 issue3Sexual activity after myocardial infarction: taboo or lack of knowledge?Analysis of the takeuchi procedure for the treatment of anomalous origin of the left coronary artery from the pulmonary artery author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Arquivos Brasileiros de Cardiologia

Print version ISSN 0066-782X

Abstract

LIMA, Carlos Eduardo Batista de et al. ICD patients with elevated defibrillation threshold: clinical behavior and therapeutic alternatives. Arq. Bras. Cardiol. [online]. 2008, vol.90, n.3, pp. 177-184. ISSN 0066-782X.  http://dx.doi.org/10.1590/S0066-782X2008000300004.

BACKGROUND: The ideal programming of the implantable cardioverter defibrillator (ICD) shock energy should be at least 10J above the defibrillation threshold (DFT), requiring alternative techniques when the DFT is elevated. OBJECTIVE: To assess the clinical behavior of ICD patients with DFT>25J and the efficacy of the chosen therapy. METHODS: Patients who had undergone ICD implantation between Jan/00 and Aug/04 (prospective database) and presented intraoperative DFT>25J were selected. The analyzed variables were: clinical characteristics, LVEF, rescue of arrhythmic events from ICD and causes of deaths. RESULTS: among 476 patients, 16 (3.36%) presented DFT>25J. The mean age was 56.5 years, and 13 patients (81%) were men. According to the baseline cardiomyopathy, 09 patients had Chagas' disease, 04 had ischemic cardiomyopathy and 03 had idiopathic cardiomyopathy. Mean LVEF was 0.37 and amiodarone was used by 94% of the patients. Mean follow-up (FU) period was 25.3 months. DFT was higher than maximum energy shock (MES) in 2 patients and it was necessary to implant an additional shock electrode (array). It was programmed MES in ventricular fibrillation zone of ICD therapy in the other patients. In the FU, 03 patients had 67 successful appropriate shock therapies (AST). There were 05 noncardiac and 02 heart failure deaths. The patients who died showed higher DFT levels (p=0.044) without correlation with death because there wasn't unsuccessful AST. CONCLUSION: In this cohort of ICD patients, the occurrence of elevated DFT (>25J) was low, leading to alternative therapies. There was an association with severe ventricular dysfunction, although without correlation to the causes of death.

Keywords : Defibrillation threshold; defibrillators, implantable; death, sudden, cardiac.

        · abstract in Portuguese     · text in English | Portuguese     · pdf in English | Portuguese