SciELO - Scientific Electronic Library Online

 
vol.28 número2Oxidação eletroquímica do metanol sobre partículas de PtRu e PtMo suportadas em carbono de alta área superficialPreparação e caracterização eletroquímica de nanoparticulas de Pt dispersas em óxido de nióbio índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

Compartilhar


Eclética Química

versão impressa ISSN 0100-4670versão On-line ISSN 1678-4618

Resumo

ROSA, T. F.; SACZK, A. A.; ZANONI, M. V. B.  e  STRADIOTTO, N. R.. Voltammetric determination of necrodil sodium using glassy carbon electrode. Eclet. Quím. [online]. 2003, vol.28, n.2, pp.63-68. ISSN 1678-4618.  https://doi.org/10.1590/S0100-46702003000200008.

Electroanalytical studies had been carried with the Nedocromil Sodium, an antiasthmatic drug, using the techniques of Linear Scan, Diferencial-Pulse and Square Wave Voltammetry. The technique of Linear Scan Voltammetry was used for determination of Nedocromil Sodium, at a glassy carbon electrode, in pH 4 Britton-Robinson buffer. Two irreversible reduction peaks where obtained in the values of potential of 0,86 V and 1,1 V. Calibration graphs were shown to be linear in the range 5,0x10-4 - 5,0x10-3 mol L-1. The coefficients of linear correlation have been equal to 0,9990, being the detection limit equal to 8,2x10-5 mol L-1 and the amperometric sensitivity equal to 6,3x103 mA/ mol L-1. Diferencial-Pulse Voltammetry two irreversible reduction peaks were obtained at the values of potential of -0.67 V and -0.75 V. The study of the dependence of Ipc with the concentration of the solution showed linearity in the range 3,0x10-6 - 1,0x10-5 mol L-1, with coefficient of linear correlation of 0,9990. The detection limit was calculated to be 4,9x10-7 mol L-1, being the amperometric sensitivity equal to 8,7x104 µA/ mol L-1. The technique of Square Wave Voltammetry was used for the studies of the Nedocromil Sodium in the range 5,0x10-7 - 1,0x10-5 mol L-1. Two irreversible reduction peaks where obtained in the values of potential of 0,80 V and 0,91 V. The coefficients of linear correlation have been equal to 0,9748, being the detection limit equal to 2,7x10-6 mol L-1 and the amperometric sensitivity equal to 1,1x106 µA/ mol L-1.

Palavras-chave : nedocromil sodium; linear scan voltammetry; diferencial-pulse voltammetry; square wave voltammetry; asthma.

        · resumo em Português     · texto em Português     · Português ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons