vol.35 issue11The decrease in uroporphyrinogen decarboxylase activity induced by ethanol predisposes rats to the development of porphyria and accelerates xenobiotic-triggered porphyria, regardless of hepatic damageAntimicrobial resistance among invasive Haemophilus influenzae strains: results of a Brazilian study carried out from 1996 through 2000 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Brazilian Journal of Medical and Biological Research

On-line version ISSN 1414-431X

Abstract

BENCHIMOL-BARBOSA, P.R. et al. Clinical assessment of the effect of digital filtering on the detection of ventricular late potentials. Braz J Med Biol Res [online]. 2002, vol.35, n.11, pp. 1285-1292. ISSN 1414-431X.  http://dx.doi.org/10.1590/S0100-879X2002001100005.

Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI) and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD) filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40), clinically normal controls, GII (N = 158), subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT), and GIII (N = 23), subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05) for GII and 0.31 for GIII (P = NS)]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05). Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.

Keywords : High resolution electrocardiogram; Digital filtering; Health technology assessment.

        · text in English     · pdf in English