SciELO - Scientific Electronic Library Online

 
vol.15 issue1Initial study in ministernotomy and mini-incision Dante Pazzanese Institute of CardiologyExpression of nitric oxide synthases in coronary artery disease after heart transplantation author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

Share


Brazilian Journal of Cardiovascular Surgery

Print version ISSN 0102-7638On-line version ISSN 1678-9741

Abstract

PACHON MATEOS, José Carlos et al. Right ventricular bifocal stimulation in treatment of heart failure with dilated cardiomyopathy. Rev Bras Cir Cardiovasc [online]. 2000, vol.15, n.1, pp.44-54. ISSN 1678-9741.  https://doi.org/10.1590/S0102-76382000000100007.

BACKGROUND: Widening of QRS by ventricular conventional pacing (CP) impairs ventricular contractility and mitral performance. PURPOSE: To study an alternative mode of cardiac stimulation with narrower QRS, using 2 leads in the right ventricle and to test it, compared to CP. MATERIAL AND METHODS: 5 dilated cardiomyopathy patients (3 Chagas´ disease, 2 unknown) with cardiac failure (NYHA III/4) and pacemaker (PM) indication, 4 male/1 female, mean age 52.2. years, cardiac shape 3+/4+, chronic AF with AVB, were submitted to endocardial PM implants with 2 right ventricular leads. The first in the His bundle area (septal) and the second, conventional, in the right ventricular apex. The generator was Biotronik Dromos DR (the short programmable AV = 15ms). The septal lead was connected to the atrial outflow and the one of the apex to the ventricular exit. After 2 weeks, they were studied by echocardiogram, in 3 stimulation modes in the same session with same cardiac rate: mode "AAI" (septal), mode VVI (conventional) and mode "DDT" with AV interval=15ms (almost simultaneous bifocal stimulation). RESULTS: The averages of the parameters studied were: n1a07t0b.gif (9767 bytes) CONCLUSION: The echocardiographic evaluation for the immediate comparison in the same patient with 3 stimulation modes, revealed: 1. The conventional mode showed the worse hemodynamic performance; 2. the bifocal mode showed the best result with mean increase of the EF of 6.8% and of CO in 0.6 l/min, mean reduction of LA in 7.5 cm2, mean reduction of the area of mitral regurgitation in 7.6 cm2 and mean reduction in the QRS duration of 61ms, (p < 0.03). It was the best stimulation in cardiomyopathy with heart failure, functional mitral regurgitation and pacemaker indication.

Keywords : Cardiomyopathy [congestive]; Cardiomyopathy [therapy]; Pacemaker [artificial]; Cardiac output [low therapy].

        · abstract in Portuguese     · text in Portuguese     · Portuguese ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License