Repair of Penetrating Pericardial and Diaphragmatic Injury with Cormatrix® Patch in a Case of Suicide Attempt

Abstract

The authors report the case of a suicide attempt. A 59-year-old man with self-inflicted penetrating chest trauma underwent emergency cardiothoracic surgery. Pre-operative computed tomography scan showed critical proximity between the blade and the right ventricle. Intraoperative findings showed a pericardial laceration and a huge diaphragmatic lesion with heart and abdominal organs integrity. The diaphragm muscle was repaired with a CorMatrix® patch, an acceptable alternative to the traditional synthetic mesh avoiding infection and repeated herniation.

Keywords:
Diaphragm/Injuries; Pericardium/Injuries; Thoracic Injuries/Surgery; Suicide, Attempted