Abstract
Objective:
To describe a new technique of sternal closure, modified from the conventional figure-of-eight approach, which can provide a secure closure and prevent sternal complications.
Methods:
The modified technique is based on the intercalation of the caudal portion of each steel wire passed along the sternum. This is a retrospective analysis of patients operated with this modified technique at our institution between January 2014 and December 2016.
Results:
One hundred and forty-three patients underwent sternal closure with the modified technique. In-hospital mortality rate was 1.4% (n=2). No sternal instability was observed at 30 days postoperatively. Two patients developed mediastinitis that required extraction of the wires.
Conclusion:
Short-term results have shown that the modified sternal closure technique can be used safely and effectively, with complications rates being consistent with worldwide experience.
Keywords:
Sternum - Surgery; Mediastinitis; Steel; Bone Wires; Hospital Mortality; Wound Closure Techniques