vol.14 número2Applications of capillary electrophoresis to the analysis of compounds of clinical, forensic, cosmetological, environmental, nutritional and pharmaceutical importanceDetermination of catecholamines in pharmaceutical formulations using a biosensor modified with a crude extract of fungi laccase (Pleurotus ostreatus) índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Articulo

Indicadores

Links relacionados

Compartir


Journal of the Brazilian Chemical Society

versión impresa ISSN 0103-5053
versión On-line ISSN 1678-4790

Resumen

BORGES, Daniel L. G.; DIAS, Lúcia F.; VEIGA, Márcia A. M. S. da  y  CURTIUS, Adilson J.. Determination of cadmium in sediments and in sewage sludge by slurry sampling electrothermal atomic absorption spectrometry using iridium as permanent modifier. J. Braz. Chem. Soc. [online]. 2003, vol.14, n.2, pp.291-296. ISSN 0103-5053.  http://dx.doi.org/10.1590/S0103-50532003000200017.

A procedure for the determination of Cd in sediment and sewage sludge as slurries by electrothermal atomic absorption spectrometry is proposed. The slurry, 1 mg mL-1, was prepared by mixing sample ground to a particle size £ 50 mm with 5% v/v nitric acid in an ultrasonic bath. The homogeneity of the slurries was assured by passing a constant flow of argon into the autosampler cup, just before transferring an aliquot to the graphite furnace. Two permanent modifiers deposited on the platform were tested: Ru and Ir. Modifiers in solution were also tested: Pd plus Mg and phosphate alone or plus Mg. The Ir-treated tube was adopted due to its good performance as modifier and also for practical reasons. About 80% of Cd is extracted to the water phase of the slurry. To test the accuracy of the method, three certified materials were analyzed: a marine sediment, a river sediment and a domestic sewage sludge. The concentrations obtained, using calibration against aqueous standards prepared in the same medium as the slurries, are in agreement with the certified values, at a confidence level of 95%, according to the Student-t test. The limit of detection (3s) was 43 ng g-1 in the solid sample and the relative standard deviation for the sediment MESS-2 was 2.3% (n = 10).

Palabras clave : cadmium, slurry; ET AAS; modifier; sediment; sewage sludge.

        · resumen en Portugués     · texto en Inglés     · Inglés ( pdf epdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons