In vitro evaluation of the thermal alterations on the root surface during preparation with different Ni-Ti rotary instruments

The present study evaluated, in vitro, the temperature alterations on the external root surface during instrumentation with four different rotary systems. A total of 20 extracted human maxillary lateral incisors were instrumented using either the ProFile, MicroMega, Quantec or K³ systems and the thermal alterations on the root surface were recorded by means of three thermocouples attached to the coronal, middle and apical portions of the root. Mean temperature increases no higher than 0.4ºC ± 1.0ºC (ProFile system) were recorded, which indicates that these instruments are safe for the surrounding periodontal tissues.

thermal alterations; rotary instruments; nickel-titanium