OBJECTIVES: To describe a new method to analyze the static sitting postural sway and to compare the results of healthy young and older adult subjects. METHODS: Thirty-eight healthy subjects took part in the study, including 17 young adults (mean age 23±2.38 years old) and 21 older adults (mean age 67±2.42 years old). The device used to quantify trunk sway was the magnetic field sensor Polhemus® 3Space Isotrack II. The measurements were taken in the eyes-opened (EO) and eyes-closed (EC) condition with the subjects seated first on a wooden stable surface (SS) then on a foam unstable surface (US) without back or foot support. Each sensory condition was assessed for 90 seconds. The analyzed parameters were: maximum amplitude (Amp), total trajectory (Traj) and mean velocity (Vel) in the sagittal (X) and frontal (Y) planes. RESULTS: In the EO and EC conditions on SS, young adults presented greater postural sway in the X and Y planes on the Traj and Vel parameters. In the US, young adults showed greater Y Traj and Y Vel in the EO and EC conditions, and there was no significant difference between the groups with regard to X Traj and X Vel in the EC condition. The young adults presented greater Amp only in the EOSS condition in the X plane. CONCLUSIONS: The young adult subjects presented greater sway in the sitting position than the older adult subjects. In addition, the Polhemus® device was a useful tool to analyze static sitting postural sway and can be used in future studies that associate static sitting postural sway with the effect of various motor tasks.
postural sway; sitting balance; older adults; young adults