SciELO - Scientific Electronic Library Online

 
vol.9 issue3Cephalometric evaluation of Angle Class II division 1 treatment with Kloehn extraoral and edgewise fixed appliance: facial pattern influenceOral microflora chemical control in cleft lip and palate patients during orthodontic-surgical treatment pilot study author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

Share


Revista Dental Press de Ortodontia e Ortopedia Facial

On-line version ISSN 1980-5500

Abstract

MOURA, Walter Leal de; MOREIRA, Thaís Cristina Araújo  and  TELES, João Batista Mendes. Evaluation of the resistance to traction of orthodontic devices - bracket, bouton and frame - bonded in premolar with autopolimerizable resin. "in vitro" study. Rev. Dent. Press Ortodon. Ortop. Facial [online]. 2004, vol.9, n.3, pp.110-115. ISSN 1980-5500.  https://doi.org/10.1590/S1415-54192004000300011.

Restrained is the tooth which, reached its physiological moment of eruption, shows some obstruction to accomplish it. The treatment, with orthodontic-surgical involvement, type drives at to dislocate the dental element for right position in the dental arch, without to cause damages for adjacent dental element, re-establishing the aesthetics and function. Therefore, the direct bonding of orthodontic bracket and bouton for retained teeth traction became the preferred technic for, besides more clear, it demands smaller surgical amplitude and tissue removal to grant access to the dental crown. The research intended analyse the intensity of applied force to the entirety teeth/device/tie-wire, tractioning through, and to observe the splot rupture. Maked use of 45 premolar, conserved in 0.9%¹ physiological serum, that was divided into three groups (15 with brackets, 15 with boutons and 15 with frames). The tooth was filled in PVC pipe filled with acrylic resin and the devices was bonded to the teeth with autopolimerizable resin. After the bonding realization of the orthodontic devices, the tooth was be preserved in physiological serum and the tests was be realized after 72 hours of the bonding by means of a computer program. The bracket endured to medium force of 36,0N, being the junction wire-device the spot less resistant; the bouton endured to medium force of 41,2N, the juncion wire-bouton was the plot less resistant and the frame was endured to medium force of 28,8N, being the junction teeth/frame the plot less resistant.

Keywords : Tractioning; Restrainment; Canine restrainmed.

        · abstract in Portuguese     · text in Portuguese     · Portuguese ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License