SciELO - Scientific Electronic Library Online

 
vol.39 issue3An alternative synthesis of 1,2,3,4-tetrahydro-9H-pyrido-[3,4-b]-indoleEvaluation of new polysaccharides networks for extended-release purposes: mesquite seed gum (MSG), xanthan gum and chitosan author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

Share


Revista Brasileira de Ciências Farmacêuticas

Print version ISSN 1516-9332

Abstract

NASCIMENTO, Jorge Willian Leandro et al. Micromethod for plasma cefuroxime quantification through high performance liquid chromatography: application to the prophylaxy of patients submitted to cardiac surgery. Rev. Bras. Cienc. Farm. [online]. 2003, vol.39, n.3, pp.265-272. ISSN 1516-9332.  http://dx.doi.org/10.1590/S1516-93322003000300006.

An improved, simple, selective and sensitive micromethod based on HPLC-UV is described to determine cefuroxime plasma levels, a second generation cephalosporin. Once changes on pharmacokinetics of drugs in patients submitted to heart surgery with cardiopulmonary bypass and hypothermia (CPB-H) were reported previously, the objective of the present study was to investigate cefuroxime plasma levels for antimicrobial prophylaxis of infections in those patients after surgery using HPLC-UV. Only 200 µL of plasma were required, and cefuroxime was determined by a chromatographic method using reversed phase system, after a simple clean up of plasma samples. Peaks monitored at 280 nm were eluted isocratically at 12.5 min (cefuroxime) and at 4.0 min (vancomicyn, internal standard,) from a 4  µm, NovaPak column (150 x 3.9 mm) using a binary mobile phase at flow rate 0.8 mL/min, consisting of 0.375 M acetate buffer, pH 5,0 and acetonitrile, 96:4 (v/v). The method validated with basis of parameters evaluated for the confidence limits of cefuroxime measurements in spiked blank plasma, presents 0.1 µg/mL sensitivity, 0.2 - 200 µg/mL linearity, (r2 0.998), systematic error of 98.2% and 96.9% (intra- and interday accuracy), intra- and interday precision (CV %: 3.2 % and 4.2 %). A good stability and high percentage of recovery (99.2%) were obtained. Patients received cefuroxime 6 g i.v. bolus (1,5 g, 4 times in 24 hours), showed in the first postoperative day plasma levels of 108.0 µg/mL (zero), 32.8 µg/mL (3rd h), 9.9  µg/mL (6th h), 3.4 µg/mL (9th h) and 0.8 µg/mL (12th h), after the last dose.

Keywords : Cefuroxime; Plasma; HPLC-UV; Prophylaxis; Heart surgery.

        · abstract in Portuguese     · text in Portuguese     · Portuguese ( pdf epdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License