Acessibilidade / Reportar erro

Different culture media applied to the study of Cryptococcus neoformans susceptibility to amphotericin B and fluconazole

Diferentes meios de cultivo empregados ao estudo da suscetibilidade de Cryptococcus neoformans frente a anfotericina B e fluconazol

This study compared the performance of three culture media used for the determination of minimal inhibitory concentration (MIC) of amphotericin B and fluconazole against 48 Cryptococcus neoformans strains. For amphotericin B the media employed were RPMI 1640 medium, as indicated by NCCLS as reference, Yeast Nitrogen Base (YNB) as proposed by Ghannoum et al. (YNB-1), Antibiotic medium 3 (AM3) indicated by others, and YNB as proposed by us (YNB-2). In YNB-1, amphotericin B showed broader MIC ranges, varying from 0.125 µg/ml to 1.0 µg/ml; in RPMI 1640 medium and YNB-2 the MICs were similar and in AM3 the MIC ranges were narrower. The same pattern was observed for MIC 90%. For fluconazole the media employed were RPMI 1640 and YNB-1. The MIC ranges were broader and elevated when YNB-1 was employed. MIC 50% were 2.0 µg/ml in RPMI 1640 medium and 4.0 µg/ml in YNB-1. Our results indicate that RPMI 1640 supplemented with 2% glucose allowed a good growth at 48h; YNB as recommended by Ghannoum et al. provided a broader MIC range, AM3 provided a narrow MIC range for amphotericin B, and YNB-2 was very similar to RPMI 1640 medium.

Cryptococcus neoformans; susceptibility; antifungal agents


Sociedade Brasileira de Microbiologia USP - ICB III - Dep. de Microbiologia, Sociedade Brasileira de Microbiologia, Av. Prof. Lineu Prestes, 2415, Cidade Universitária, 05508-900 São Paulo, SP - Brasil, Ramal USP 7979, Tel. / Fax: (55 11) 3813-9647 ou 3037-7095 - São Paulo - SP - Brazil
E-mail: bjm@sbmicrobiologia.org.br