SciELO - Scientific Electronic Library Online

 
vol.6 issue6Actions of sitting and rising from the ground are negatively affected by overweight author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Revista Brasileira de Medicina do Esporte

Print version ISSN 1517-8692

Abstract

SOUZA, Eva Cantalejo Munhoz Stadler de et al. Cardiopulmonary stress testing in clinical practice. Rev Bras Med Esporte [online]. 2000, vol.6, n.6, pp. 249-254. ISSN 1517-8692.  http://dx.doi.org/10.1590/S1517-86922000000600005.

Cardiopulmonary stress testing (CPT) is a very useful tool to determine the diagnosis and prognosis in clinical practice. The objective of this study is to demonstrate that data obtained in a laboratory outside the hospital are similar to those described in the literature. METHODOLOGY: Patients were submitted to CPT, treadmill ramp protocol, and 13 lead electrocardiogram to evaluate CPT in the clinical practice. RESULTS: Among 261 CPT, 53.3% were male, mean age 48.2 ± 14.3 years, with active (45.2%) or sedentary (34.5%) lifestyle. Male patients showed higher maximal aerobic capacity (O2 max) and a significant decrease of O2 for each ten years of increment in age, but it decreased from 30 to 69 years in females. Females showed a significant higher (p = 0.0006) distribution in functional classes described as "in training programs or well trained and high motivation". A O2 max was superior in maximal effort tests, but anaerobic threshold (O2AT) did not show differences between maximal or submaximal tests. The functionalcapacity evaluated by O2AT as a fraction (%) of the O2 max predicted in comparison to the fraction of the O2 max measured was more rigorous, which implies a higher number of patients with circulatory impairment (p = 0.002) and also with lower physical capacity as opposed to active patients or patients under training programs (p < 0.00001); however, between 50.0% and 59.0% of the patients could be classified equally by one or the other criteria (p = 0.221). The more frequent abnormality in CPT was that it did not achieve 85.0% of the O2 max predicted, more significant for females. CONCLUSION: Despite the limitations, this experience indicates that CPT data are reproducible in a laboratory outside the hospital, suggesting that CPT may be applied in clinical practice.

Keywords : Spirometry; Cardiopulmonary exercise testing; Spiroer-gometry.

        · abstract in Portuguese     · text in Portuguese     · pdf in Portuguese