SciELO - Scientific Electronic Library Online

 
vol.13 número2Comparative study of rules employed for calculation of pediatric drug dosageMTA and calcium hydroxide for pulp capping índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Journal of Applied Oral Science

versión impresa ISSN 1678-7757

Resumen

VASCONCELLOS, Diego Klee de et al. The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks. J. Appl. Oral Sci. [online]. 2005, vol.13, n.2, pp. 120-125. ISSN 1678-7757.  http://dx.doi.org/10.1590/S1678-77572005000200005.

OBJECTIVES: The present in vitro study was designed to compare the differences in the vertical misfit of implant-supported frameworks using three different forces for tightening the bridge locking screws: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. METHODS: The investigation was conducted based on the results given by 9 six-unit nickel-chromium (2 abutments/ 4 pontics) screw-retained implant-supported frameworks. The structures were exposed to simulated porcelain firings. The marginal misfit measurements were made using a traveling measuring microscope at selected screw tightening forces: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. The results were submitted to one-way ANOVA with repeated measures on one factor, and post hoc pairwise comparisons using Tukey test (5%). RESULTS: The mean marginal misfit of the frameworks, fastening the screws by hand until first resistance, was 41.56µm (SD±12.45µm). The use of torque driver devices caused a significant reduction in marginal opening (p<0.05). With the lowest torque available (10Ncm), the mean marginal discrepancy at the abutment-framework interface was reduced an average of 52% to a mean marginal opening of 19.71µm (SD±2.97µm). After the use of the 20Ncm torque driver, the mean marginal discrepancy of the frameworks was reduced an average of 69% to a mean marginal opening of 12.82µm (SD±4.0µm). Comparing the use of torque drivers with 10 and 20 Ncm torque, the means are not significantly different from one another. CONCLUSION: The seating force has an important effect on the vertical misfit measurements, once it may considerably narrow the vertical misfit gaps at the abutment-framework interface, thus leading to a misjudgment of the real marginal situation.

Palabras llave : Dental implants; Osseointegration; Implant-supported dental prosthesis; Torque; misfit.

        · resumen en Portugués     · texto en Inglés     · pdf en Inglés