SciELO - Scientific Electronic Library Online

 
vol.33 número3Simpatectomia torácica por videotoracoscopia para tratamento da hiperidrose primária: estudo retrospectivo de 521 casos comparando diferentes níveis de ablação índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

Compartilhar


Jornal Brasileiro de Pneumologia

versão impressa ISSN 1806-3713versão On-line ISSN 1806-3756

Resumo

TERRA, Ricardo Mingarini et al. Self-expanding stent made of polyester mesh with silicon coating (Polyflex®) in the treatment of inoperable tracheal stenoses. J. bras. pneumol. [online]. 2007, vol.33, n.3, pp.241-247. ISSN 1806-3713.  http://dx.doi.org/10.1590/S1806-37132007000300003.

OBJECTIVE: To evaluate the Polyflex® stent in terms of its efficacy, ease of implantation, and complications in patients with tracheobronchial affections. METHODS: This was a prospective study, in which sixteen patients with inoperable tracheal stenosis secondary to orotracheal intubation (n = 12), neoplasia (n = 3), or Wegener's granulomatosis (n = 1) were monitored. Of these patients, eleven were women, and five were men. The mean age was 42.8 years (range, 21-72 years). Patients were submitted to implantation of a total of 21 Polyflex® stents. All procedures were carried out in the operating room under general anesthesia, and the stents were implanted via suspension laryngoscopy using the stent applicator. RESULTS: Stents were implanted and symptoms were resolved in all cases. The stents remained in place for a mean period of 7.45 months, ranging from 2 to 18 months. The complications observed in the immediate postoperative period were dysphonia (in two patients, 12.5%) and odynophagia (in two patients, 12.5%). Late complications were cough (in ten patients, 62.5%), migration (in seven patients, 43.75%), granuloma formation (in two patients, 12.5%), and pneumonia (in one patient, 6.25%). CONCLUSION: The Polyflex® stent is easily implanted, easily removed, well tolerated by patients and effective in resolving symptoms. However, its use is associated with a high rate of migration, especially in patients with post-orotracheal intubation stenosis.

Palavras-chave : Tracheal stenosis; Intubation, intratracheal; Prostheses and implants; Stents.

        · resumo em Português     · texto em Português | Inglês     · Português ( pdf epdf ) | Inglês ( pdf epdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons