SciELO - Scientific Electronic Library Online

 
vol.18 issue3Heart rate variability in women with joint hipermobilityMusculoskeletal risks in different departments of a footwear manufacturing company author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Fisioterapia e Pesquisa

Print version ISSN 1809-2950

Abstract

GUARIGLIA, Débora Alves; PEREIRA, Ligia Maxwell; PEREIRA, Hugo Maxwell  and  CARDOSO, Jefferson Rosa. Reliability and usability assessment of three different softwares for photogrammetric analysis of hip flexion angle. Fisioter. Pesqui. [online]. 2011, vol.18, n.3, pp. 247-251. ISSN 1809-2950.  http://dx.doi.org/10.1590/S1809-29502011000300008.

The photogrammetric analysis can be done by using different softwares. Thus, the purpose of this study was to assess the reliability and the usability of three different softwares during the hip flexion photogrammetric analysis and to discuss the qualitative and quantitative aspects of each one. Twenty-six volunteers participated in this study with age between 19 and 30 years old (x=25.4 years, SD=2.5) who underwent the sit-to-reach test through adapted Wells´ bench. Reflective skin markers were positioned in the anterior superior iliac spine and greater trochanter. The image acquisition was collected in the maximum limit of test execution. All softwares showed a high reliability between measures, besides it was presented specifics advantages and disadvantages during adoption one of them. SAPO´s software was considered with major points for professional practice, although taking the analysis for scientific research all softwares demonstrated characteristics that must be taken into consideration before adopting them.

Keywords : biomechanics; range of motion; articular; hip joint; reproducibility of results.

        · abstract in Portuguese     · text in Portuguese     · pdf in Portuguese