Services on Demand
Journal
Article
Indicators
Cited by SciELO
Access statistics
Related links
Cited by Google
Similars in SciELO
Similars in Google
Share
RGO - Revista Gaúcha de Odontologia
Print version ISSN 0103-6971On-line version ISSN 1981-8637
Abstract
BUENO, Juliana do Prado Tavares; MELO, Tiago André Fontoura de and KUNERT, Gustavo Golgo. Evaluation of the tip of standardized D0 gutta percha cones of four Rotary systems, by means of an endodontic ruler. RGO, Rev. Gaúch. Odontol. [online]. 2017, vol.65, n.4, pp.299-302. ISSN 1981-8637. https://doi.org/10.1590/1981-863720170002000023168.
Objective
: This study aimed to evaluate the D0 diameter of standardized gutta-percha cones for four mechanized systems: ProTaper Universal®, Mtwo®, Wave One® and Reciproc®.
Methods:
An endodontic calibrator ruler was used to measure the D0 diameter of 60 main cones of the above systems. Measurements were made according 3 scores as follows: gutta-percha cone fits exactly into the same hole as the endodontic ruler gauge (score 1), cone falls short of the ruler gauge whole size (score 2); or exceeding the ruler gauge hole size (score 3). The diameters D0 obtained were compared with the values reported by manufacturers. All data were analyzed by means of T Test, at 1% level of significance.
Results:
The average value measured was significantly higher than the measures established by manufacturers (p <0.001).
Conclusion
: The gutta-percha cones of ProTaper Universal® systems Mtwo®, Wave One® and Reciproc® were not standardized, except for R40 cone of the Reciproc® system (Reciproc®). The trend was for variation in the D0 Diameter towards increasing measurement values.
Keywords : Dimensional measurement accuracy; Endodontics; Gutta-percha; Root canal obturation.