Figure 1
Comparison between experimental results of monolithic beam-column connection and numerical simulations using model proposed by Alva and El Debs [21[21] ALVA, G. M. S.; EL DEBS, A. L. H. C. Moment-rotation relationship of RC beam-column connections: Experimental tests and analytical model. Engineering Structures, v. 56, p. 1427-1438, 2013. ] - Lee et al. [29[29] LEE, L.N.; WIGHT, J.K.; HANSON, R.D. RC beam-column joints under large load reversals. Journal of the Structural Division 1977; 103(12): 2337-50.]: specimen 2
Figure 2
Cracking and slippage of reinforcement in beam-column joints
Figure 3
Deformation mechanisms in exterior beam-column connections [22[22] ALVA, G. M. S.; FERREIRA, M. A.; EL DEBS, A. L. H. C. Engastamento parcial de ligações viga-pilar em estruturas de concreto armado. Revista IBRACON de Estruturas e Materiais, v. 2, n. 4, p.356-379, 2009.]
Figure 4
End-fixity factor - ABNT NBR 9062 [24[24] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 9062: Projeto e execução de estrururas de concreto pré-moldado. Rio de Janeiro: ABNT, 2017.]
Figure 5
Moment-rotation relationship of precast concrete beam-column connections - Brazilian Code [24[24] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 9062: Projeto e execução de estrururas de concreto pré-moldado. Rio de Janeiro: ABNT, 2017.]
Figure 6
Definition of effective area Ac,eff for prediction of crack spacing
Figure 7
Typical floor plan of five-storey building (dimensions in cm)
Figure 8
Typical floor plan of nineteen-storey building (dimensions in cm)
Figure 9
Algorithm used to determine the end-fixity fator αR of the connections
Figure 10
Ferreira et al. [1[1] FERREIRA, M.A.; EL DEBS, M.K.; ELLIOT, K.S. Determinação teórico-experimental da relação momento-rotação em ligações viga-pilar de estruturas pré-moldadas de concreto. V Simpósio EPUSP sobre estruturas de concreto. São Paulo: EPUSP, 2003.] model: lateral displacements for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 11
Ferreira et al. [1[1] FERREIRA, M.A.; EL DEBS, M.K.; ELLIOT, K.S. Determinação teórico-experimental da relação momento-rotação em ligações viga-pilar de estruturas pré-moldadas de concreto. V Simpósio EPUSP sobre estruturas de concreto. São Paulo: EPUSP, 2003.] model: coefficient γz for for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 12
Ferreira et al. [1[1] FERREIRA, M.A.; EL DEBS, M.K.; ELLIOT, K.S. Determinação teórico-experimental da relação momento-rotação em ligações viga-pilar de estruturas pré-moldadas de concreto. V Simpósio EPUSP sobre estruturas de concreto. São Paulo: EPUSP, 2003.] model: longitudinal reinforcement of column P1 for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 13
Ferreira et al. [1[1] FERREIRA, M.A.; EL DEBS, M.K.; ELLIOT, K.S. Determinação teórico-experimental da relação momento-rotação em ligações viga-pilar de estruturas pré-moldadas de concreto. V Simpósio EPUSP sobre estruturas de concreto. São Paulo: EPUSP, 2003.] model: longitudinal reinforcement of column P2 for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 14
Ferreira et al. [1[1] FERREIRA, M.A.; EL DEBS, M.K.; ELLIOT, K.S. Determinação teórico-experimental da relação momento-rotação em ligações viga-pilar de estruturas pré-moldadas de concreto. V Simpósio EPUSP sobre estruturas de concreto. São Paulo: EPUSP, 2003.] model: longitudinal reinforcement of column P6 for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 15
Alva and El Debs [21[21] ALVA, G. M. S.; EL DEBS, A. L. H. C. Moment-rotation relationship of RC beam-column connections: Experimental tests and analytical model. Engineering Structures, v. 56, p. 1427-1438, 2013. ] model: lateral displacements for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 16
Alva and El Debs [21[21] ALVA, G. M. S.; EL DEBS, A. L. H. C. Moment-rotation relationship of RC beam-column connections: Experimental tests and analytical model. Engineering Structures, v. 56, p. 1427-1438, 2013. ] model: coefficient γz for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 17
Alva and El Debs [21[21] ALVA, G. M. S.; EL DEBS, A. L. H. C. Moment-rotation relationship of RC beam-column connections: Experimental tests and analytical model. Engineering Structures, v. 56, p. 1427-1438, 2013. ] model: longitudinal reinforcement of column P1 for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 18
Alva and El Debs [21[21] ALVA, G. M. S.; EL DEBS, A. L. H. C. Moment-rotation relationship of RC beam-column connections: Experimental tests and analytical model. Engineering Structures, v. 56, p. 1427-1438, 2013. ] model: longitudinal reinforcement of column P2 for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Figure 19
Alva and El Debs [21[21] ALVA, G. M. S.; EL DEBS, A. L. H. C. Moment-rotation relationship of RC beam-column connections: Experimental tests and analytical model. Engineering Structures, v. 56, p. 1427-1438, 2013. ] model: longitudinal reinforcement of column P6 for nineteen-storey and five-storey buildings, considering perfectly rigid and partially restrained connections
Table 1
Classification of connections for precast structures - adapted from [24[24] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 9062: Projeto e execução de estrururas de concreto pré-moldado. Rio de Janeiro: ABNT, 2017.]
Table 2
Classification system of connections for precast structures - adapted de [2[2] FERREIRA, M. A.; ARAÚJO, D. L.; JEREMIAS Jr, A. C.; CATOIA, B.; KATAOKA, M. N. Estabilidade global de estruturas pré-moldadas: efeito das ligações semi-rígidas. In: 1o Encontro Nacional de Pesquisa-Projeto-Produção em Concreto Pré-Moldado. São Carlos, 2005.]