Acessibilidade / Reportar erro

Development and validation of dissolution method for carvedilol compression-coated tablets

The present study describes the development and validation of a dissolution method for carvedilol compression-coated tablets. Dissolution test was performed using a TDT-06T dissolution apparatus. Based on the physiological conditions of the body, 0.1N hydrochloric acid was used as dissolution medium and release was monitored for 2 hours to verify the immediate release pattern of the drug in acidic pH, followed by pH 6.8 in citric-phosphate buffer for 22 hours, to simulate a sustained release pattern in the intestine. Influences of rotation speed and surfactant concentration in medium were evaluated. Samples were analysed by validated UV visible spectrophotometric method at 286 nm. 1% sodium lauryl sulphate (SLS) was found to be optimum for improving carvedilol solubility in pH 6.8 citric-phosphate buffer. Analysis of variance showed no significant difference between the results obtained at 50 and 100 rpm. The discriminating dissolution method was successfully developed for carvedilol compression-coated tablets. The conditions that allowed dissolution determination were USP type I apparatus at 100 rpm, containing 1000 ml of 0.1N HCl for 2 hours, followed by pH 6.8 citric-phosphate buffer with 1% SLS for 22 hours at 37.0 ± 0.5 ºC. Samples were analysed by UV spectrophotometric method and validated as per ICH guidelines.

Carvedilol; Compression coated tablets; pH 6.8 citric-phosphate buffer; Hydrochloric acid; Sodium lauryl sulphate


Universidade de São Paulo, Faculdade de Ciências Farmacêuticas Av. Prof. Lineu Prestes, n. 580, 05508-000 S. Paulo/SP Brasil, Tel.: (55 11) 3091-3824 - São Paulo - SP - Brazil
E-mail: bjps@usp.br