Acessibilidade / Reportar erro

In vitro force delivery of nickel-titanium superelastic archwires in vertical displacement

OBJECTIVE: The purpose of this study was to evaluate the force delivered by different superlastic nickel-titanium wires during vertical displacement, in order to determine whether their stress release meets the criteria for constant and light forces that are usually accredited to these archwires. METHOD: Ten samples of 6 brands of 0.016-in archwires (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) were tested in a complete metal model using Dynalock brackets (3M Unitek™). In the canine position, there was a sliding bracket connected to a pole. This set was related to a load cell of 0.5 kg attached to a universal testing machine (Autograph AG-199kNG, Shimadzu). The crosshead speed was 0.5 mm/min and the maximum displacement was 1.0 mm. The model was submerged in temperature-controlled water. The results were analyzed by ANOVA (p < 0.05), using the software SAS System 8.02, Cry, NC, USA. RESULTS: The TP archwire had the lowest force throughout the test, although the final force was high (277.91 g). The Rocky Mountain archwire had the highest force release (455.41 g). CONCLUSION: The different brands of wires tested in this study failed in delivering low and constant forces as expected from superlastic nickel-titanium wires. The forces were extremely heavy for a vertical tooth movement.

Corrective orthodontics; Orthodontic archwires; Tooth movement


Dental Press International Av. Luís Teixeira Mendes, 2712 , 87015-001 - Maringá - PR, Tel: (55 44) 3033-9818 - Maringá - PR - Brazil
E-mail: artigos@dentalpress.com.br