Dissolved Air Flotation for Fiber Removal from Clear Water

ABSTRACT

We investigated the use of dissolved air flotation (DAF) to treat clear water effluent from the paper industry in order to remove fibers. The dosage of polyaluminium chloride (PAC) was varied in the following concentrations: 0, 75, 100, 125, 150 and 175 mg/L; as well as bubble rise velocity of 18 and 9 cm/min for two types of paper wastewater: print and gloss. Data were statistically analyzed through factorial arrangement 6x2x2. The treatment of the print paper effluent showed better performance in removing the analyzed parameters with an optimal dosage of 100 mg/L PAC, whereas the gloss paper effluent treatment had satisfactory removal of analyzed parameters with an optimal dosage of 150 mg/L of PAC. This led to the observation that the high efficiency directly obtained with the DAF in conjunction with the use of PAC coagulant was an excellent primary treatment option for effluent resulting from the paper industry.

Keywords:
fiber recovery; paper industry; total suspended solids

Instituto de Florestas da Universidade Federal Rural do Rio de Janeiro Rodovia BR 465 Km 7, CEP 23897-000, Tel.: (21) 2682 0558 | (21) 3787-4033 - Seropédica - RJ - Brazil