Porosity study of synthetic sandstones by non-destructive nuclear techniques

Abstract

In this paper nuclear techniques were used to describe the structural characteristics of ceramic samples. These samples were produced mainly with silica to simulate sandstones. Three sets of samples with different characteristics were analyzed using gamma ray transmission to obtain point by point porosity and X-ray microtomography to obtain the porosity, for 2D sections and the scanned bulk, as well as the pore size distribution. The transmission results indicated total porosity values of 28.6 (4.5)% for the group of samples called ceramic I and 59.6 (2.1)% for ceramic II. The samples analyzed by microtomography achieved resolutions of 1.7, 0.6 and 1.3 μm for the ceramic I, II, and III samples, respectively. This analysis indicated average porosity values of 27.9 (1.4)% for ceramic I samples and 29.4 (1.2)% for ceramic III samples.

ceramics microstructure; mechanical properties; amorphous materials; porosity


Porosity study of synthetic sandstones by non-destructive nuclear techniques

Leonardo Carmezini MarquesI* * e-mail: leocarma@yahoo.com.br ; Carlos Roberto AppoloniI; Celso Peres FernandesII

IApplied Nuclear Physics Laboratory, Physics Department, State University of Londrina - UEL, CP 6001, CEP 86051-990, Londrina, PR, Brazil

IIPorous Media and Thermophysics Properties Laboratory, Federal University of Santa Catarina - UFSC, CP 476, CEP 88040-900, Florianópolis, SC, Brazil

ABSTRACT

In this paper nuclear techniques were used to describe the structural characteristics of ceramic samples. These samples were produced mainly with silica to simulate sandstones. Three sets of samples with different characteristics were analyzed using gamma ray transmission to obtain point by point porosity and X-ray microtomography to obtain the porosity, for 2D sections and the scanned bulk, as well as the pore size distribution. The transmission results indicated total porosity values of 28.6 (4.5)% for the group of samples called ceramic I and 59.6 (2.1)% for ceramic II. The samples analyzed by microtomography achieved resolutions of 1.7, 0.6 and 1.3 μm for the ceramic I, II, and III samples, respectively. This analysis indicated average porosity values of 27.9 (1.4)% for ceramic I samples and 29.4 (1.2)% for ceramic III samples.

Keywords: ceramics microstructure, mechanical properties, amorphous materials, porosity

1. Introduction

Petroleum is currently the main power source, and it is used to provide several products, such as oil, diesel, gas, tar, plastic polymers and drugs. Petroleum and natural gas can be found underground, mainly in sedimentary bases in porous media known as reservoir rocks. These hydrocarbons fill porous spaces between grains or in fissures. During the perforation of a reservoir rock research is carried out to investigate potential accumulative structures, which involves porosity, permeability, saturation and capillarity studies1-3. Obtaining samples for this kind of research entails high costs. Therefore, the search for non-destructive techniques to describe the rock reservoir microstructure is of great importance in the extraction of petroleum. A classical method for the structural characterization of rocks is mercury intrusion porosimetry, however, this only gives information on the overall pore content4. Also, it is possible to determine the microstructural parameters from 2D images by optical microscopy or scanning electron microscopy. However, these data are not necessarily representative of the bulk material3. All these three methodologies involve destruction of the sample.

Gamma ray transmission is a technique which is very suitable for studying porosity. It is a non-destructive and quick method for determining the porosity at the millimetric scale5. It is possible to obtain very accurate porosity values for the bulk of samples such as those analyzed herein.

X-ray tomography is a non-destructive technique which was originally developed for medical imaging. It is based on the inhomogeneous absorption of X-rays in bulk material6. At present, tomography has progressed due to advances in terms of the X-ray source and detection equipment. This has led to improved resolution and consequently micrometer scale measurements, as well as 3D visualization1,4,6-9. Some equipment is even able to measure in nanometer scale10,11. This technique is able to measure the porosity, permeability, and pore size distribution, among other parameters, from 2D images of a scanned volume12,13. In addition, it is possible to reconstruct part of that volume14,15, which allows fluid flow computer simulations3,6.

The objective of this research was to evaluate the microstructure of ceramic samples manufactured to simulate sandstones. The parameters studied were porosity, permeability and pore size distribution.

2. Materials and Methods

2.1. Gamma ray transmission

The experimental set-up consists of a 2 × 2 inch NaI(Tl) scintillation detector and a 241Am (59.54 keV) gamma source, with 100 mCi activity, both filled with a cylindrical lead collimator 9.6 cm long and with an internal hole of 2 mm diameter, and a standard gamma ray spectrometry electronic chain connected to a computer. Two kinds of software were used for data acquisition: one to select a window that contains the energy source chosen for the experiments (software MCS-plus), and another to acquire the transmitted ray beam and to control the micrometric table (XZ) of sample position, time, number of points and position of each point (software samara_v2). The measurements and analyses were carried out at the Applied Nuclear Physics Laboratory of the UEL Physics Department.

The gamma ray attenuation is described by the Bear Law16:

where I0 is the initial intensity and I is the intensity of gamma rays after attenuation through a medium of length x and μ is the linear attenuation coefficient of the material.

For the determination of total porosity using gamma ray transmission it is necessary to determine the linear attenuation coefficient for the materials. Therefore, in Equation 1:

From the particle and measured linear attenuation coefficients, it is possible to calculate the porosity as follows5:

where P (%) is the porosity of the sample at a point of gamma ray transmission, μ (cm-1) is the linear attenuation coefficient corresponding at this transmission and μp (cm-1) is the linear attenuation coefficient of a sample with the same composition and without porosity.

The particle linear attenuation coefficient was obtained with the aid of the software WinXcom5. This computer program supplies the particle mass attenuation coefficient taking into account the chemical composition of the sample. The particle linear attenuation coefficient can be calculated as follows:

where μp' (cm2.g-1) is the particle mass attenuation coefficient of the material that composes the sample and ρp (g.cm-3) is the particle density of the material which was supplied by the manufacturer.

2.2. X-ray microtomography

An 1172 Skyscan scanner was used to perform the experiment. It comprises an X-ray tube with W anode operated in the voltage range of 20-100 kV at a power of 10 W. The detector is a 10 Mp (megapixel) CCD camera coupled to the scanner. This set is able to differentiate objects smaller than 1 μm. Figure 1 shows the basic steps of this setup.


X-ray tomography is based on the distribution of linear attenuation coefficients which can also be described by the Bear Law. The attenuation of the X-ray beam as it passes through the matter originates a projection in the CCD camera, and the set of projections is reconstructed in 2D sections by a filtered backprojection algorithm17,18. This procedure is performed by the NRecon software of the Skyscan series.

Each 2D section is binarized with the Imago software (image analysis software)19, so that only pixels corresponding to porous or matrix phase are considered. This procedure is based on the gray-level histogram, where the user selects the threshold for binarization1,15. This threshold is selected within a range of 0 to 255 gray tones and thus the porous phase becomes free of noise without damaging the solid phase. The 2D sections obtained are analyzed using the Imago software to determine the total porosity, permeability and pore size distribution of 2D sections and the bulk material. This software was developed at the Laboratory of Porous Media and Thermophysical Properties (LMPT), Department of Mechanical Engineering, Federal University of Santa Catarina, in association with Engineering Simulation and Scientific Software (ESSS).

Porous media, represented in a binary 2D section, can be characterized by the porous phase function Z(x)1,19:

where x denotes the position with respect to an arbitrary origin.

The porosity Ф is defined by the statistical average (denoted by 〈 〉), as follows:

In the determination of the pore size distribution in binary 2D sections, the measurement unit consists of the superficial porous area. Therefore, the pore size distribution is calculated as follows:

where Ф is the total porosity of the 2D section and Ф(r) is the porosity obtained using the opening operation with a disc (structuring element) of radius r.

2.3. Samples measurements

For the validation of the gamma ray transmission technique, two materials were analyzed to obtain their linear attenuation coefficients: water and aluminum. The linear attenuation coefficient obtained for each material was compared with the mass attenuation coefficient supplied by the WinXcom software multiplied by the thickness of the material.

Analysis was carried out with ceramic samples manufactured by the company TechMat (Tecnologia de Materiais Ltda, Rio de Janeiro, RJ, Brazil). Samples were mainly manufactured with SiO2, yielding a permeability of 46 (9) mD for the group of samples called ceramic I, 550 (20) mD for ceramic II, both with approximately 100% of SiO2, and 82 (2) mD for ceramic III, with 85 % of SiO2 and 15% of Al2O3.

For the determination of total porosity using gamma ray transmission, two sample geometries were analyzed: parallelepiped format with dimensions of 10 × 1.9 × 5 cm and cylindrical format with 3.6 cm height and 4.9 cm diameter. All samples were scanned at forty points. The parallelepiped samples were scanned on four levels at ten points, with the objective of determining the point by point porosity. The spacing between two levels and between two measurements at the same level was 1 cm. The cylindrical samples were scanned along ten lines at four points. The angular spacing between two successive lines was eighteen degrees and the spacing between two successive points along the same line was 0.7 cm. The total measurement time was 5.2 hours for the parallelepiped format, 360 seconds for each transmitted beam and 360 seconds for each incident beam measurement. The total measurement time for the cylindrical samples was 11.7 hours, 1020 seconds for each transmitted beam and 180 seconds for each incident beam measurement.

For the validation of the microtomography technique, a nylon thread sample was manufactured. This consisted of a glass cylinder of 6.920 (0.009) mm inner diameter filled with 253 nylon threads of 0.355 (0.009) mm diameter. The scanning results were compared with the geometric calculation. The acquisition parameters for this sample were 70 kV/141 μA voltage and current, respectively; 5.0 μm spatial resolution, 5 frames, 0.25 degrees of angular step, 180 rotation degrees, 2360 ms exposure time, 1048 × 2000 pixels on the CCD camera and a 1 mm aluminum filter in front of the CCD camera.

For the microtomographic experiment, one parallelepiped with dimensions of 0.6 × 0.6 × 1.2 cm was cut from an original parallelepiped of 1 × 1 × 3 cm. This procedure was carried out to simplify the acquisition. Table 1 summarizes the acquisition parameters of the samples. Some common parameters were 1048 × 2000 pixels on the CCD camera and an aluminum filter of 1 mm thickness to minimize the beam hardening20.

3. Results and Discussion

3.1. Gamma ray transmission

Table 2 shows the measured values obtained for the validation samples and those obtained with the WinXcom software. Similar results for the linear attenuation coefficient of water were obtained by Ferraz21, 0.200 (0.002) cm-1 and Pöttker22, 0.1971 (0.0005) cm-1. The result for the linear attenuation coefficient of aluminum was in agreement with that obtained using WinXcom. Therefore, it was possible to verify the good alignment of the gamma ray transmission equipment.

The particle density value for ceramic I samples is 2.201 g.cm-3, as supplied by the manufacturer. Based on this density value the WinXcom software provided a particle linear attenuation coefficient for the ceramic samples of 0.559 cm-1. For ceramic II samples, the particle density is 2.214 g.cm-3, and the particle linear attenuation coefficient is 0.562 cm-1.

Figure 2 shows point to point porosity values for parallelepiped and cylindrical samples of ceramic I. In Figure 2a and b, the porosity values for points in the same position at different levels can be observed. The parallelepiped samples presented the highest and lowest dispersion in the porosity values for P1-I and P2-I samples, respectively. At only one point the P1-I sample presented an outlier porosity value in the same position, corresponding to the 6 cm position as indicated by an arrow. In Figure 2c and d, a lower dispersion of the porosity values can be noted for the cylindrical samples than for the parallelepiped samples, mainly for sample C2-I. This is verified by the standard deviation values in Table 3. This lower dispersion may occur because the points measured on the cylindrical samples were closer than those of the parallelepiped samples due to the measurement set-up and the smaller area of the cylindrical sample.


Table 3

Table 4 shows the porosity values for parallelepiped and cylindrical samples of ceramic II, respectively. A good agreement between the results for the parallelepiped samples and the porosity values stated by the manufacturer (56.5%) was verified. However, there was poor agreement between the results for the cylindrical samples and the porosity values given by the manufacturer. The methodology used by the manufacturer to obtain the sample characteristics, such as particle density and porosity, was the Arquimedes principle23,24. This methodology employs sample immersion in liquid. Therefore, the liquid phase needs to reach all pores to supply the correct porosity value. This may explain the lower porosity value supplied by the manufacturer compared with the results of this study.

3.2. X-ray microtomography

Figure 3a shows a 2D image of the nylon thread samples manufactured for the porosity test. The threshold selected for the binarization of this sample was 21 and a total of 401 2D images were obtained. Four sets of 100 2D images were used for the analysis. This procedure was applied due to the limitation of the Imago software when dealing with large quantities of images. Figure 3b shows the porosity value for each 2D image. Each 2D porosity value has a 0.5% contrast resolution. The average porosity value was 30.4 (0.1)%. Erosion and dilation filters, respectively, were used on the binarized image due to the presence of noise. However, some imaging noise remained which caused a difference in the porosity values. The geometric porosity calculation obtained for this test sample was 33.4 (3.4)%. Thus, the average porosity value obtained from the X-ray microtomography was in agreement with the geometric porosity.


The selected thresholds for ceramic I and III samples were 146 and 103, respectively. The images obtained for ceramic II were weak due to the poor contrast resolution achieved with the parameters chosen.

Figure 4a shows a 2D image obtained with the projections reconstruction for ceramic I and (b) shows the selected area to the "Imago" software analyses. This figure shows a heterogeneity that caused higher porosity values.


Figure 5 shows the 2D porosity value for each ceramic I 2D image. The average porosity value for this sample was 27.9 (1.4)%. However, it is possible to differentiate three regions. The first is the most homogenous, 34 to 646 2D images, with 27.5% average porosity. The second shows some heterogeneity related to Figure 6, 647 to 788 2D images, with 29.1 % average porosity. The rectangle indicates the greatest influence of the heterogeneity and the third region includes 789 to 1011 2D images, with 28.2% average porosity. The average permeability value obtained for the ceramic I sample was 73 (6) mD. This result showed poor agreement with that supplied by the manufacturer (46 (9) mD). The Imago software does not perform well in computing the permeability for complex samples, which could explain this difference. This problem can be attributed to two factors. Firstly, some spurious points are created on all 2D images during the binarization process. Although these artifacts do not cause significant changes in the determination of the porosity or pore size distribution, they can influence significantly the permeability values. Secondly, the methodology employed by the Imago software was created considering an isotropic medium19, which is not exactly the case.


Figure 6

Table 5 shows the porosity values obtained by gamma ray transmission and X-ray microtomography and those supplied by the manufacturer. The results are in good agreement, particularly the X-ray microtomography and gamma ray transmission results for the cylindrical sample.

Figure 7a shows a 2D image obtained with the projection reconstruction for ceramic III and b shows its binarized 2D image. The 2D image and the binarized image have the same area because an ROI reconstruction parameter was selected. As in the case of ceramic I, ceramic III also shows heterogeneity. However, ceramic III has the densest region, as can be seen on the left side of the hole shown in figure.


Figure 8 shows the 2D porosity value for each 2D image of ceramic III. The average porosity value for this sample was 29.4 (1.2)%. The region scanned is characterized by two heterogeneities. The first is a hole occurring on 575 to 900 2D images and the second is a dense region present on 687 to 900 2D images. The upper rectangle indicates a greater influence of the hole and the lower rectangle a greater influence of the dense region. A third region on 789 to 1011 2D images had an average porosity of 28.2%. The average permeability value for the ceramic III sample was 49 (4) mD. As in the case of the ceramic I sample, this result for ceramic III showed poor agreement with the value supplied by the manufacturer (82 (2) mD).


Figure 9 presents the average pore size distribution for the ceramic III sample. The frequency for 10 to 50 μm pore radii is shown in the detail. This distribution shows that 78% of pores have radii of 2.5 to 6.4 μm. Furthermore, the pores with radii shorter than 1.3 μm, using spatial resolution, could not be quantified.


Figure 10 shows the 3D reconstruction of the ceramic I 2D images. The heterogeneity that led to the higher porosity values can be partially observed. Figure 11 shows the 3D reconstruction of the ceramic III 2D images. It is possible to observe a few of the holes that caused the higher porosity values, as well as to show the densest region that led to lower porosity values.



4. Conclusions

In this paper gamma ray transmission and X-ray microtomography techniques were used to carry out the structural analysis of ceramic samples. Parallel results for a nylon thread sample show the capacity of the X-ray microtomography to reconstruct 2D images as well as to quantify the structural parameters of porous materials such as ceramic samples. The results also show the influence of the degree of noise on the porosity values. These results could be bettered with the improvement of parameters, such as 360º rotation.

The agreement in the results for the ceramic I samples shows that both techniques are appropriate for studying this kind of material, because the gamma ray transmission porosity values confirm those obtained by X-ray microtomography, and the 2D and 3D images provide an understanding of the porosity profile changes. The higher quality of the 2D images for the ceramic III sample indicates the importance of determining the parameters applying this methodology. In this study, the low angular steps and the high spatial resolution are responsible for the difference in quality.

The average pore size distribution is a complementary result that accounts for the greater occurrence of high pore radius values. It also indicates that a better spatial resolution should be used.

This paper demonstrates that gamma ray transmission and X-ray microtomography are two techniques which can be used in combination to evaluate ceramic samples.

Received: March 29, 2011;

Revised: June 22, 2011

  • 1. Appoloni CR, Fernandes CP, Innocentini MDM and Macedo A. Ceramic foams porous microstructure characterization by X-ray microtomography. Materials Reserach 2004; 7(4):557-56. http://dx.doi.org/10.1590/S1516-14392004000400008
  • 2. Taud H, Martinez-Angeles R, Parrot JF and Hernandez-Escobedo L. Porosity estimation method by X-ray computed tomography. Journal of Petroleum Science & Engineering 2005; 47:209-217. http://dx.doi.org/10.1016/j.petrol.2005.03.009
  • 3. Appoloni CR, Rodrigues CRO and Fernandes CP. Porous microstructure characterization of a sandstone reservoir using high-resolution X-ray microtomography. In International Symposium of the Society of Core Analysts; 2005; Toronto, Canada. Toronto: SCA2005-41; 2005.
  • 4. Gallucci E, Scrivener K, Groso A, Stampanoni M and Margaritodo G. 3D experimental investigation of the microstructure of cement pastes using synchrotron X-ray microtomography (μCT). Cement and Concrete Research 2007; 37:360-368. http://dx.doi.org/10.1016/j.cemconres.2006.10.012
  • 5. Appoloni CR and Pöttker WE. Non-destructive porosity profile measurement of amorphous materials by gamma-ray transmission. Applied Radiation and Isotopes 2004; 61:1133-1138. http://dx.doi.org/10.1016/j.apradiso.2003.12.013
  • 6. Moreno-Atanasio R, Williams RA and Xiaodong J. Combining X-ray microtomography with computer simulation for analysis of granular and porous materials. Particuology 2010; 8:81-99. http://dx.doi.org/10.1016/j.partic.2010.01.001
  • 7. Per Spanne and Rivers ML. Computerized microtomography using synchrotron radiation from the NSLS. Nuclear Instruments and Methods in Physics Research Section B 1987; 24-25(part 2):1063-1067.
  • 8. Rabaglino E, Baruchel J, Boller E, Elmoutaouakkil A, Ferrero C, Ronchi C et al. Study by microtomography of 3D porosity networks in irradiated beryllium. Nuclear Instruments and Methods in Physics Research B 2003; 200:352-357. http://dx.doi.org/10.1016/S0168-583X(02)01700-7
  • 9. Bernard D, Gendron D, Heintz J, Bordère S and Etourneau J. First direct 3D visualization of microstructural evolutions during sintering through X-ray computed microtomography. Acta Materialia 2005; 53:121-128. http://dx.doi.org/10.1016/j.actamat.2004.09.027
  • 10. Tkachuk A, Duewer F, Cui H, Ferser M, Wang S and Yun W. X-ray computed tomography in Zernike phase contrast mode at 8 keV with 50-nm resolution using Cu rotating anode x-ray source. Zeitschrift für Kristallographie 2007; 222:650-655. http://dx.doi.org/10.1524/zkri.2007.222.11.650
  • 11
    Xradia, Inc. Available from: <http://www.xradia.com>
    » link
  • 12. Jones KW, Spanne P, Lidquist WB, Conner WC and Ferrero M. Determination of polymerization particle morphology using synchrotron computed microtomography. Nuclear Instruments and Methods in Physics Research Section B 1992; 68:105-110. http://dx.doi.org/10.1016/0168-583X(92)96059-8
  • 13. Jones KW, Derkar PB, Mahajan D, Lindquist WB and Feng H. Microstructure of natural hydrate host sediments. Nuclear Instruments and Methods in Physics Research B. 2007; 261:504-507. http://dx.doi.org/10.1016/j.nimb.2007.03.032
  • 14. Farber L, Tardos G and Michaels JN. Use of X-ray tomography to study the porosity and morphology of granules. Powder Technology 2003; 132:57-63. http://dx.doi.org/10.1016/S0032-5910(03)00043-3
  • 15. Linc L and Miller JD. Network analyses of filter cake pore structure by high resolution X-ray microtomography. Chemical Engineering Journal 2000; 77:79-86. http://dx.doi.org/10.1016/S1385-8947(99)00149-7
  • 16. Demir D and Keles G. Radiation transmission of concrete including boron waste for 59.54 and 80.99 keV gamma rays. Nuclear Instruments and Methods in Physics Research B. 2006; 245:501-504. http://dx.doi.org/10.1016/j.nimb.2005.11.139
  • 17. Kak A C and Slaney M. Principles of computerized tomographic imaging IEEE Press; 1999.
  • 18. Lame O, Bellet D, Di Michiel M and Bouvard D. In situ microtomography investigation of metal powder compacts during sintering. Nuclear Instruments and Methods in Physics Research B. 2003; 200:287-294. http://dx.doi.org/10.1016/S0168-583X(02)01690-7
  • 19
    Imago. Image Analysis System Version 2.1.4. Engineering Simulation and Scientific Software Ltda - ESSS; 2002.
  • 20. Ketcham RA and Carlson WD. Acquisition, optimization and interpretation of X-ray computed tomographic imagery: applications to the geosciences. Computers & Geosciences 2001; 27:381-400. http://dx.doi.org/10.1016/S0098-3004(00)00116-3
  • 21. Ferraz ES. Simultaneous thickness and damp determination of soils by 137Cs and 241 Am gamma ray attenuation [Thesis]. Piracicaba: University of São Paulo; 1974.
  • 22. Pöttker WE. Measurement of amorphous materials porosity by gamma ray transmission [Thesis]. Londrina: State University of Londrina; 2000.
  • 23. D'Angelo L, D'Onofrio L and Gonzalez G. Nanophase intermetallic FeAl obtained by sintering after mechanical alloying. Journal of Alloys and Compounds 2009; 483:154-158. http://dx.doi.org/10.1016/j.jallcom.2008.07.208
  • 24. Colle RD, Fortulan CA and Fontes SR. Manufacture of ceramic membranes for application in demulsification process for cross-flow microfiltration. Desalination 2009; 245:527-532. http://dx.doi.org/10.1016/j.desal.2009.02.016
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      05 Aug 2011
    • Date of issue
      Sept 2011

    History

    • Accepted
      22 June 2011
    • Received
      29 Mar 2011
    ABM, ABC, ABPol UFSCar - Dep. de Engenharia de Materiais, Rod. Washington Luiz, km 235, 13565-905 - São Carlos - SP- Brasil. Tel (55 16) 3351-9487 - São Carlos - SP - Brazil
    E-mail: pessan@ufscar.br