Acessibilidade / Reportar erro

Influence of the incorporation of triclosan methacrylate on the physical properties and antibacterial activity of resin composite

Abstract

The incorporation of antimicrobials in the composites as an attempt to reduce bacterial adhesion without jeopardizing mechanical properties is a challenge for Dentistry.

Objective:

To evaluate the bacterial adhesion and physical properties of a composite containing the methacrylate triclosan- derivative monomer (TM).

Methodology:

TM was synthesized and added to an experimental composite. Samples were divided into two groups: Control and TM (13.4 wt%). Antibacterial Activity: Three specimens of each material were prepared and placed on bacterial suspensions of Streptococcus mutans for 1, 5 and 10 days. After these periods the counting of the colonies (log10) was performed. Assays was performed in triplicate. Physical Properties: Three-body Abrasion (TBA): Ten specimens of each material were prepared and stored at 37°C/24 h. The surface roughness (Ra) and hardness (KHN) were analyzed. Next, the specimens were submitted to abrasive wear (30,000 cycles) and re-evaluated for Ra and KHN; Sorption/solubility (SS): cylindrical specimens (n=10) were prepared and weighted. The specimens were immersed in deionized water for 7 days at 37°C and then their weight was verified again. SS were calculated using accepted formulas; Diametral tensile strength (DTS): specimens (n=10) underwent test performed in an Instron universal testing machine at a crosshead speed of 1 mm/min. Data were submitted to appropriate statistical tests according to data distribution and assay (p<0.05).

Results:

Bacterial Adhesion: TM showed a significant reduction on biofilm accumulation in the evaluated periods: 1 day (1.537±0.146); 5 days (2.183±0.138) and 10 days (4.469±0.155) when compared with Control: 1 day (4.954±0.249); 5 days (5.498±0.257) and 10 days (6.306±0.287). Physical Properties: For TBA, SS and DTS no significant difference was found between groups Control and TM. The incorporation of methacrylate triclosan-based monomer in the experimental composite reduce bacterial adhesion of S. mutans and did not affect important polymer properties.

Keywords:
Triclosan; Composite resins; Surface properties; Hardness; Anti-bacterial agents

Introduction

Secondary caries are the most common reason for replacing dental restorations, presumably related to biofilm formation on and within gaps at the restoration margins,11- Eltahlah D, Lynch CD, Chadwick BL, Blum IR, Wilson NH. An update on the reasons for placement and replacement of direct restorations. J Dent. 2018;72:1-7. in this way, antibacterial properties of restorative materials are of major clinical importance and would allow dental tissue preparation, positively influencing the treatment outcome, especially for high caries-risk patients.22- Łukomska-Szymańska M, Zarzycka B, Grzegorczyk J, Sokołowski K, Półtorak K, Sokołowski J, et al. Antibacterial properties of calcium fluoride-based composite materials: in vitro study. Biomed Res Int. 2016;2016:1048320. To reduce the proliferation of microorganisms on the tooth-composite interface and around dental restorations, various chemical compounds have been added to the materials composition.33- Szram A, Póltorak K, Podlewska M, Sokołowski J, Łukomska-Szymańska M. Selected antibacterial components in dental materials - literature review. Prot Stomatol. 2015;65(5):476-81.,44- Półtorak K, Podlewska M, Szram A, Sokołowski J, ŁukomskaSzymańska M. Composite materials with antimicrobal properties literature review. e-Dentico. 2016;60(2):84-9.

Restorative resin-composites, due to surface roughness and residual monomers release after polymerization,55- Nedeljkovic I, Teughels W, De Munck J, Van Meerbeek B, Van Landuyt KL. Is secondary caries with composites a material-based problem? Dent Mater. 2015;31(11):247-77. favor bacterial colonization much more than other dental materials, such as amalgam, ceramics, gold alloys, or glass ionomer cements.66- Farrugia C, Camilleri J. Antimicrobial properties of conventional restorative filling materials and advances in antimicrobial properties of composite resins and glass ionomer cements - a literature review. Dent Mater. 2015;31(4):89-99. Additionally, bacteria present in the biofilm also induces further microorganism adhesion to composite filling,77- Yamamoto K, Ohashi S, Taki E, Hirata K. Adherence of oral streptococci to composite resin of varying surface roughness. Dent Mater J. 1996;15(2):201-4. leading to surface softening and increase roughness of the composite.

Sing, et al.88- Singh C, Dua V, Vyas M, Verma S. Evaluation of the antimicrobial and physical properties of an orthodontic photo-activated adhesive modified with an antiplaque agent: an in vitro study. Indian J Dent Res. 2013;24(6):694-700. (2013) and das Neves, et al.99- Neves PB, Agnelli JA, Kurachi C, Souza CW. Addition of silver nanoparticles to composite resin: effect on physical and bactericidal properties in vitro. Braz Dent J. 2014;25(2):141-5. (2014) evaluated the incorporation of antibacterial agents, such as chlorhexidine and silver nanoparticles in the organic matrix of resin-composites. For these compounds, antibacterial activity was effective, however it occurred though the release of antibacterial agents.88- Singh C, Dua V, Vyas M, Verma S. Evaluation of the antimicrobial and physical properties of an orthodontic photo-activated adhesive modified with an antiplaque agent: an in vitro study. Indian J Dent Res. 2013;24(6):694-700.,99- Neves PB, Agnelli JA, Kurachi C, Souza CW. Addition of silver nanoparticles to composite resin: effect on physical and bactericidal properties in vitro. Braz Dent J. 2014;25(2):141-5. The release of this agents can be toxic or harm the mechanical properties of the restorative material.1010- Imazato S, McCabe JF. Influence of incorporation of antibacterial monomer on curing behavior of a dental composite. J Dent Res. 1994;73(10):1641-5. Triclosan (2,4,4’-trichloro-2’-hydroxydiphenyl ether) is an antibiotic widely used in oral hygiene products, such as mouthwash and toothpaste, due to its safe profile and broad spectrum of activity.1111- Sharma NC, Galustinas HJ, Qaqish J, Galustians A, Rustogi K, Petrone ME, et al. Clinical effectiveness of a dentifrice containing triclosan and copolymer for controlling breath odor. Am J Dent. 2007;20(2):79-82. Toxicologycal studies showed that triclosan and its metabolites are well tolerated by human beings.1212- Lyman FL, Furia T. Toxicology of 2,4,4-trichloro-2-hydroxydiphenyl ether. Ind Med. 1969;38(4):45-52.,1313- DeSalva JS, Kong BM, Lin YL. Triclosan: a safety profile. Am J Dent. 1989;2:185-96. De Salva, et al.1313- DeSalva JS, Kong BM, Lin YL. Triclosan: a safety profile. Am J Dent. 1989;2:185-96. (1989) showed that triclosan is not a mutagen, carcinogen, or teratogen agent and is safe in reproductive studies.1313- DeSalva JS, Kong BM, Lin YL. Triclosan: a safety profile. Am J Dent. 1989;2:185-96.

Triclosan has been incorporated into restorative material in powder form, although antibacterial activity was observed, the incorporation caused further degradation of the restorative material because it was leached.1414- Rathke A, Staude R, Muche R, Haller B. Antibacterial activity of a triclosancontaining resin composite matrix against three common oral bacteria. J Mater Sci Mater Med. 2010;21(11):2971-7.,1515- Imazato S, Torri M, Tsuchitani Y. Antibacterial effect of composite incorporating triclosan against Streptococcus mutans. J Osaka Univ Dent Sch. 1995;35:5-11. In this way, the incorporation of a triclosan-based monomer into the resin matrix of composites would be more appropriate, since it can reduce bacterial adhesion by contact on the restoration surface without reducing mechanical properties over time, which can improve the long-term performance of the restorative material.

Also, we should consider that, in addition to the chemical challenges due to acids from the biofilm fermentation process, restorative materials are also constantly subject to mechanical challenges in the oral cavity.1616- Paula AB, Fucio SB, Ambrosano GM, Alonso RC, Sardi JC, Puppin-Rontani RM. Biodegradation and abrasive wear of nano restorative materials. Oper Dent. 2011;36(6):670-7. Daily toothbrushing of the already damaged surface causes gradual loss of the softened material (matrix and filler), leading to color change, contour loss, and increase roughness of the restoration surface again, influencing its aesthetic and clinical longevity.1717- Kakaboura A, Fragouli M, Rahiotis C, Silikas N. Evaluation of surface characteristics of dental composites using profilometry, scanning electron, atomic force microscopy and gloss-meter. J Mater Sci Mater Med. 2007;18(1):155-63.

For resin-composites, hydrolysis can negatively affect physical and mechanical properties, what is particularly important for restorative dental composites, since they are always exposed to the water present in the oral environment.1818- Park J, Eslick JJ, Ye Q, Misra A, Spencer P. The influence of chemical structure on the properties in methacrylate-based dentin adhesives. Dent Mater. 2011;27(11):1086-93.,1919- Ferracane J. Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater. 2006;22(3):211-22. The chemical resistance of these materials is related to the quality of polymerization and to the chemical characteristics of the monomers present in the resin matrix.2020- Sideridou I, Tserki V, Papanastasiou G. Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylate-based dental resins. Biomaterials. 2003;24(4):655-65. In this way, the evaluation of sorption and solubility is very important, since these phenomenon are related to hydrolytic degradation of resin materials and may serve as precursors to a variety of chemical and physical processes, such as swelling, plasticization, oxidation and hydrolysis.1919- Ferracane J. Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater. 2006;22(3):211-22.,2020- Sideridou I, Tserki V, Papanastasiou G. Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylate-based dental resins. Biomaterials. 2003;24(4):655-65.

In this context, the incorporation of a triclosanbased monomer into the resin matrix for dental composites would be very interesting, as long as it reduced biofilm formation without altering the properties of the material, which can improve the long-term performance of the restorative material in the oral cavity. Thus, the aim of this study is to evaluate the bacterial adhesion and physical properties of a composite containing the monomer based on triclosan methacrylate.

Methodology

Formulation of the composites

Triclosan-methacrylate (TM), was obtained by the esterification of triclosan, i.e. 2,4,4-trichloro hydroxy diphenyl ether supplied by Sigma Aldrich, St. Louis, MO, USA, with methacrylic acid in dimethylformamide (DMF) solution. In this study, two low viscosity composites were formulated:(C) Control composite and; (TM) Composite containing TM monomer. For both composites, a resin matrix with Bisphenol A ethoxylate dimethacrylate (BisEMA – Sigma-Aldrich, Inc., St. Louis, MO, USA, Batch #03C514HF), and triethylene glycol dimethacrylate (TEGDMA – Sigma-Aldrich Inc., St. Louis, MO, USA, Batch #01612M), were prepared in the proportion 6:4.2121- Paula AB, Taparelli JR, Alonso RC, Innocentini-Mei LH, Puppin-Rontani RM. Synthesis and application of triclosan methacrylate monomer in resin composites. Clin Oral Investig. 2019;23:965-74. For TMC, the TM monomer was incorporated into this resin matrix at 14.4%wt (percentage determined in a pilot study). After, for both materials, the photoinitiator BAPO [Phenylbis (2,4,6-trimethylbenzoyl) phosphine 511447-10g Lot #MKBJ9151V] by Aldrich Chemistry, St. Louis, MO, USA, was incorporated at 2wt% and the inhibitor dibutylhydroxytoluene (BHT) was incorporated at 0.1wt%. Both resin matrix were reinforced with silanized barium aluminum silicateglass fillers in two different sizes: (1) BaAlSi ultrafine – 1 µm (GM27884 Lot #Sil4387, SCHOTT) at 40 wt% and (2) BaAlSi nanofine – 180 nm (GM27884 Lot #Sil4232, SCHOTT) at 10%, both from Electronic Packaging GmbH, Landshut, Germany. The fillers were added incrementally and mixed homogeneously to a 50 wt% loading using a high-speed mixing machine (SpeedMixer™ DAC 150.1 FV, Hauschild, SC, USA). The experimental composites were manipulated under filtered orange light. The composition of the experimental composites formulated for this study were based on a previous study.2222- Atai M, Watts DC, Atai Z. Shrinkage strain-rates of dental resinmonomer and composite systems. Biomaterials. 2005;26(24):5015-20.

For all tests, the experimental composites were photoactivated for 40 s, using a Bluephase LED light curing unit (Ivoclar Vivadent, Schaan, Liechtenstein) with a power density of 1,200 mW/cm2. A radiometer (Hilux Dental Curing Light Meter, Benlioglu Dental Inc., Demetron, Ankara, Turkey) was used to verify the power density of the curing unit.

Bacterial adhesion assay

Strains of Streptococcus mutans UA159 were used in this study. To prepare the inoculum, S. mutans was first grown on Mitis Salivarius agar (Difco Laboratories, Sparks MD, MI, USA) plates at 37°C for 48 hours supplemented with 10% CO2. Subsequently, single colonies were inoculated into 5 mL of brain heart infusion (BHI) broth (Difco Laboratories) and incubated at 37°C for 18 hours. The culture was adjusted to an optical density of 0.6 at 550 nm (approximately 3x1011 CFU/mL) and diluted 1:20 in BHI supplemented with 0.1% sucrose. Circular specimens (5 mm diameter × 1 mm thick) of each material (C and TM) were prepared (n=3) in a polyvinyl siloxane mold (Aquasil, Dentsply DeTrey, Konstanz, Germany) covered with a mylar strip. Specimens were not submitted to polishing, presenting smooth surface without bubbles or defects. All the specimens were sterilized with ultraviolet light for 20 minutes. The specimens were kept in static culture medium containing 1% sucrose for 1, 5 and 10 days (37°C/10% CO2). The medium was renewed every 24-hours. Next, the specimens were washed for 5 minutes in RTF solution to remove the non-adhered bacteria. The bacterial suspensions obtained were serially diluted in MSA.2121- Paula AB, Taparelli JR, Alonso RC, Innocentini-Mei LH, Puppin-Rontani RM. Synthesis and application of triclosan methacrylate monomer in resin composites. Clin Oral Investig. 2019;23:965-74. The purity of the cultures in the media was verified every day using Gram staining and plating samples. For the adhesion assay three independent experiments were performed in triplicate. The data were transformed into Log10 and submitted to two-way ANOVA (α=0.01), considering material (2 levels: C and TM) and time (3 levels: 1 day, 5 days and 10 days), using Bioestat 5.0. Means were compared by the Tukey's test.

Simulated toothbrusing

Ten specimens of each composite (5-mm diameter × 2-mm thick) were prepared in plastic molds, covered with a transparent polyester strip and photocured for 40 s. All specimens were maintained in the dark at 100% relative humidity and at 37°C for 24 hours. The surfaces were wet polished with silicon carbide abrasive papers 600-, 1200-, and 2000-grit (Norton SA, São Paulo, SP, Brazil) in an automatic polisher (APL4; Arotec, Cotia, SP, Brazil) to obtain a flat surface. After, specimens were ultrasonically cleaned (Ultrasonic Cleaner, model USC1400, Unique Co, São Paulo, Brazil) in distilled water for 10 minutes to remove polishing debris.

All specimens were analyzed for surface roughness and Knoop hardness (baseline measures). For surface roughness testing, the specimens were analyzed using a Surfcorder SE1700 instrument (Kosaka Corp, Tokyo, Japan), with cutoff length of 0.25 mm, at a tracing speed of 0.1 mm/s. The mean surface roughness values (Ra), mm of each specimen were obtained from three successive measurements of the center of each disk in different directions, and the Ra mean was calculated for each disk. Next, Knoop hardness measurements were performed using a microhardness tester (HMV-2; Shimadzu Corp., Tokyo, Japan) under a load of 50 g for 15 s. Three indentations were made for each specimen, and the average value of the three readings was considered.

In order to suppress abrasive degradation of the surfaces, brushing simulation was conducted at 250 cycles/minute, for 30,000 cycles with a 200-g load on all the groups. Colgate Total dentifrice (Colgate Palmolive Ind e Com Ltda, São Bernardo do Campo, SP, Brazil) diluted in distilled water (1:2) was used as abrasive third body. Next, specimens were washed in an ultrasonic bath for 10 minutes, gently dried and reevaluated for roughness and hardness. Data were submitted to two-way repeated ANOVA measures, considering Material (2 levels: C and TMC) and evaluation period (2 levels: before abrasion and after abrasion), and means were compared using Tukey's tests with a 5% significance level.

Sorption and solubility test

Sorption and solubility evaluation were performed according to Inagaki, et al.2323- Inagaki LT, Dainezi VB, Alonso RC, Paula AB, Garcia-Godoy F, Puppin-Rontani RM, et al. Evaluation of sorption/solubility, softening, flexural strength and elastic modulus of experimental resin blends with chlorhexidine. J Dent. 2016;49:40-5. (2016). Specimens (7 mm diameter x 1 mm thickness) (n=5) of each material were prepared in a polyvinyl siloxane mold (Express XT, 3 M ESPE, St. Paul, MN, US). The diameter of 7 mm was selected based on the active tip of the light curing device, in order to promote homogeneous polymerization. To obtain a smooth and standard flat surface of the specimens, a polyester strip was placed over and covered with a glass slide until the light curing process. Each disk was light cured for 40 s. After light curing, the disks were individually dry stored in closed Eppendorfs at 37°C for 24 h. After this period, the Eppendorfs containing the disks were opened and placed in a desiccator containing silica gel in a vacuum environment at 37°C for 24 h. Then each disk was weighed in an analytical balance (Tel Marke, Bel Quimi, São Paulo, SP, Brazil) with an accuracy of 0.001 g. This cycle of drying in silica and weighing in a balance was repeated until the constant mass (M1) of each disk was obtained.

Immediately after establishing M1, the diameter and thickness of disks were measured in two different directions using a digital caliper (0.01–150 mm, Product Code 500-144B, Mitutoyo, Tokyo, Japan) with an accuracy of 0.01 mm. The mean value of diameter and thickness were obtained to calculate the volume of the cylinder (V), in cubic millimeters (mm3). Then the disks were immersed, individually, in falcon tubes with 4.66 mL of deionized water at 37°C for 7 day. After 7 days, the disks were removed from the water and dried in absorbent paper for 15 s. One minute after being removed from the water, each disk was weighed only once in an analytical balance to obtain the mass (M2). After this, the disks were placed again in a vacuum desiccator with silica gel, and the cycle aforementioned was performed until they kept a constant mass (M3). The values (in mg/mm33- Szram A, Póltorak K, Podlewska M, Sokołowski J, Łukomska-Szymańska M. Selected antibacterial components in dental materials - literature review. Prot Stomatol. 2015;65(5):476-81.) of water sorption (Wsp) and solubility (Wsl) were calculated using the following equation: Wsp=(M2 - M3)/V and Wsl=(M1 - M3)/V. Data were subjected to the Mann-Whitney test (p<0.05), using the software ASSISTAT Version 7.7 en (2017) (http://www.assistat.com; UFCG, Campina Grande, Brazil).

Diametral tensile strength (DTS)

For DTS testing, ten cylindrical specimens (4 mm diameter x 2 mm height) of each composite (C and TM) were prepared in a teflon mold. Specimens (n=10) were placed in the mold between two polyester films and cured from both sides for 40 s. Specimens were carefully removed by unscrewing the split mold and were subsequently finished to remove any irregularities using 1000-grit abrasive papers (Norton SA). After 24 h the storage at 37°C, DTS was measured using a universal testing machine (Instron, model 4411, Canton, MA, USA) at a crosshead speed of 1 mm/minute. The DTS value in MPa was calculated using the following Eq: DTS=2F/πdt, where F is the maximum force applied to failure (N), d is the diameter (4 mm) and t is the thickness (2 mm). Data were subjected to normality tests with the Shapiro Wilk test. After, all data were submitted to one-way ANOVA and t-test (α=0.05) using the software ASSISTAT Version 7.7 en (2017).

Results

Table 1 shows the mean values and standard deviation of S. mutans adhesion to the surface of the experimental materials (C and TM) after 1, 5 and 10 days. The incorporation of the triclosan methacrylate monomer in the experimental composite (TM) significantly reduced the adhesion of S. mutans on the surface of the material in all periods when compared with the control composite (C), evidencing the antibacterial effect of TM monomer over time. However, after 10 days of biodegradation a significant increase was observed in the adhesion of S mutans on the surface of the TM when compared with days 1 and 5.

Table 1
Means ± standard deviation of bacterial adhesion of Streptococcus mutans (UFC/ml (log10) in surfaces of the composites Control and TM after 1, 5 and 10 days

Table 2 shows the mean Ra and KHN values and the standard deviations, before and after abrasion. No significant difference was found between C and TM for Ra and KHN values, before or after abrasion; however, for both materials a significant increase was observed in Ra and KHN values after abrasion.

Table 2
Surface Roughness means (µm) and Knoop hardness (KHN) and standard deviation standard of the composites Control and TM submitted to abrasion

Table 3 shows median, minimum and maximum values of sorption/solubility (mg/mm3) and diametral tensile strength (MPa) ± standard deviation of composites Control and TM. For both tests, no significant difference was found between C and TM.

Table 3
Median, minimum and maximum values of sorption/solubility (mg/mm33- Szram A, Póltorak K, Podlewska M, Sokołowski J, Łukomska-Szymańska M. Selected antibacterial components in dental materials - literature review. Prot Stomatol. 2015;65(5):476-81.) and Diametral Tensile Strength (MPa) of composites Control and TM

Discussion

Biofilm growth around restorations causes pH decrease and consequently a recurrent process of demineralization.44- Półtorak K, Podlewska M, Szram A, Sokołowski J, ŁukomskaSzymańska M. Composite materials with antimicrobal properties literature review. e-Dentico. 2016;60(2):84-9. In order to reduce restoration failing, antibacterial agents have been added to dental materials.77- Yamamoto K, Ohashi S, Taki E, Hirata K. Adherence of oral streptococci to composite resin of varying surface roughness. Dent Mater J. 1996;15(2):201-4.99- Neves PB, Agnelli JA, Kurachi C, Souza CW. Addition of silver nanoparticles to composite resin: effect on physical and bactericidal properties in vitro. Braz Dent J. 2014;25(2):141-5. Triclosan has been incorporated into different polymers with wide degrees of success.2424- Petersen RC. Computational conformational antimicrobial analysis developing mechanomolecular theory for polymer biomaterials in materials science and engineering. Int J Comp Mat Sci Eng. 2014;3(1):1450003. In this study, it was observed that the composite containing triclosan-methacrylate had inhibitory effects on bacterial adhesion in all evaluated times.

Triclosan was thought to reduce bacterial growth and polymer adherence directly from the polymer surface.2424- Petersen RC. Computational conformational antimicrobial analysis developing mechanomolecular theory for polymer biomaterials in materials science and engineering. Int J Comp Mat Sci Eng. 2014;3(1):1450003. This bacterial adhesion inhibition can be explained by the triclosan molecular mechanical agitation on weak bacterial membranes. Further, bacterial inhibition includes possible membrane structural bond rotation entanglements with secondary bonding defects. Both forms of bacterial inhibition can be disruptive, particularly during the growth log phase, when actively dividing cells require correct membrane fluidity.1515- Imazato S, Torri M, Tsuchitani Y. Antibacterial effect of composite incorporating triclosan against Streptococcus mutans. J Osaka Univ Dent Sch. 1995;35:5-11. Also, secondary bonding between bacteria and polymer was interrupted by triclosan vibrational fluctuating mechanomolecular bond rotations as a possible mechanism to prevent microbial surface attachments.1515- Imazato S, Torri M, Tsuchitani Y. Antibacterial effect of composite incorporating triclosan against Streptococcus mutans. J Osaka Univ Dent Sch. 1995;35:5-11.,2424- Petersen RC. Computational conformational antimicrobial analysis developing mechanomolecular theory for polymer biomaterials in materials science and engineering. Int J Comp Mat Sci Eng. 2014;3(1):1450003.

Despite the details of the mechanism of action of triclosan-methacrylate monomer remains undetermined, it is possible that it takes place by contact, considering that the element chlorine (Cl), a constituent of the triclosan molecule, is fixed in the polymer network after curing. Due to the presence of Cl, the immobilized agent may induce inactivation of glucosyl transferase in bacteria reducing plaque growth.2525- Brecx M, Theilade J, Attstrom R. An ultrastructural quantitative study of the significance of microbial multiplication during early dental plaque growth. J Periodont Res. 1983;18(2):177-86.

Brecx, et al.2525- Brecx M, Theilade J, Attstrom R. An ultrastructural quantitative study of the significance of microbial multiplication during early dental plaque growth. J Periodont Res. 1983;18(2):177-86. (1983) demonstrated that plaque growth is the result of the proliferation of bacteria already present on the surface and of a continuous deposition of additional bacteria. Therefore, a lower rate of bacterial growth and a lower rate of glucan synthesis would be responsible for the significantly lower bacterial adhesion on the experimental composite2121- Paula AB, Taparelli JR, Alonso RC, Innocentini-Mei LH, Puppin-Rontani RM. Synthesis and application of triclosan methacrylate monomer in resin composites. Clin Oral Investig. 2019;23:965-74. compared with the control within 24 hours, 5 and 10 days. However, according to the results of this study, bacterial adhesion in the TM containing composite have increased after 10 days, what can demonstrate that this material presents limited antibacterial activity, which will be evaluated in future studies.

Even so, the use of methacrylate triclosan monomer immobilized/attached to the polymer network would be advantageous, since it provides the antibacterial effect of triclosan and may prevent voids within the polymer structure. When the antibacterial compound is not attached to the polymer, it is leached,1515- Imazato S, Torri M, Tsuchitani Y. Antibacterial effect of composite incorporating triclosan against Streptococcus mutans. J Osaka Univ Dent Sch. 1995;35:5-11. facilitating the hydrolytic degradation of the material. In this matter, further studies must be carried out, focusing on the long-term biodegradation of the material.

A resin composite must show satisfactory mechanical properties to be accepted as a successful restorative dental material. Mechanical brushing is suitable for simulating normal oral hygiene procedures to standardize brushing application, distance and frequency of force on the specimen.2626- Costa J, Adams-Belusko A, Riley K, Ferracane JL. The effect of various dentifrices on surface roughness and gloss of resin composites. J Dent. 2010;38(2):123-8. There is no agreed clinical threshold for unacceptable values for the roughness of resin composites. However, Bollen, et al.2727- Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997;13(4):258-69. (1997) reported that a material incapable of attaining and/or maintaining the Ra value below 0.2 µm would be susceptible to an increase in plaque accumulation, with higher risk of caries and periodontal inflammation2727- Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997;13(4):258-69.. Regarding the low viscosity composites tested in this study, there was no difference between the tested materials. both showed Ra values lower than 0.2 µm before abrasion and higher than 0.2 µm after abrasion.

Clinically, increasing the surface roughness of restorative materials influences the aesthetic characteristic of the restoration, due to discoloration and wear. Also, the periodontal health may be affected, since higher roughness favor biofilm accumulation, which may cause gingivitis. The development of secondary caries may also be a consequence of biofilm accumulation. In this study, brushing abrasion was conducted since it can contribute to the disintegration of dental materials. The surface of the compound disintegrates over time, which leads to roughness, staining and increased wear.2828- Heintze SD, Zellweger G, Cavalleri A, Ferracane J. Influence of the antagonist material on the wear of different composites using two different wear simulation methods. Dent Mater. 2006;22(2):166-75.

In this study, both groups showed increased surface roughness after brushing. The brushing simulator was used to demonstrate wear behavior, resulting in wear of the organic matrix and of the filler particles, which were exposed and protruded,2929- Al Khuraif AA. An in vitro evaluation of wear and surface roughness of particulate filler composite resin after tooth brushing. Acta Odontol Scand. 2014;72(8):977-83. increasing the surface roughness values. In addition, the formulation of the composite also affects its surface roughness.3030- Pires-de-Souza FC, Garcia LF, Hamida HM, Casemiro LA. Color stability of composites subjected to accelerated aging after curing using either a halogen or a light emitting diode source. Braz Dent J. 2007;18(2):119-23. The monomer TEGDMA is somewhat hydrophilic when compared to BisGMA and its presence in the formulation of resin composites has been associated with increased water sorption3131- Ertaş E, Güler AU, Yücel AC, Köprülü H, Güler E. Color stability of resin composites after immersion in different drinks. Dent Mater J. 2006;25(2):371-6. and consequently with the material degradation, which was accelerated by brushing. Still, similar values of roughness were observed for both groups before and after abrasion, showing that the incorporation of the TM did not affect the surface smoothness of the material against mechanical wear.

The hardness of resin composites depends on the filler type and content, and it has been suggested to correlate with other mechanical properties, such as abrasion resistance.2929- Al Khuraif AA. An in vitro evaluation of wear and surface roughness of particulate filler composite resin after tooth brushing. Acta Odontol Scand. 2014;72(8):977-83. In this study, similar hardness values were observed for both groups before and after abrasion. The same filler type and content (50 wt%) may have contributed to similar hardness values between control and TM groups. Before abrasion, both groups presented lower KHN than after. It is possible that the polyester strip and microscope slide load on the composite during specimen preparation lead inorganic fillers to concentrate at the center of the composite disc.3232- Paula AB, Tango RN, Sinhoreti MA, Alves MC, Puppin-Rontani RM. Effect of thickness of indirect restoration and distance from the light-curing unit tip on the hardness of a dual-cured resin cement. Braz Dent J. 2010;21(2):117-22. Therefore, the resin monomer would emerge to the top region and would lead to lower KNH in the surface of the specimens. After abrasion, both groups showed increased hardness, due to the removal of this resin-rich superficial layer. Abrasion commonly takes place through a gradual removal of the softened organic material.3333- Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997;76(7):1405-11. It is suggested that this removal may lead to the exposure of particles, which may be responsible for the increase in the material hardness.

The properties of the resin composites are also influenced by the water present in the oral environment3434- Park J, Eslick JJ, Ye Q, Misra A, Spencer P. The influence of chemical structure on the properties in methacrylate-based dentin adhesives. Dent Mater. 2011;27(11):1086-93. due to water sorption. Water causes hydrolysis, which may cause swelling and degradation of the organic matrix in resin composites.3535- Örtengren U, Wellendorf H, Karlsson S, Ruyter IE. Water sorption and solubility of dental composites and identification of monomers released in an aqueous environment. J Oral Rehabil. 2001;28(12):1106-15. It occurs because hydrogen bonds are formed between water and polar groups present in polymers, such as hydroxyl and carbonyl, disrupting entanglements and secondary bonding between polymer chains.2323- Inagaki LT, Dainezi VB, Alonso RC, Paula AB, Garcia-Godoy F, Puppin-Rontani RM, et al. Evaluation of sorption/solubility, softening, flexural strength and elastic modulus of experimental resin blends with chlorhexidine. J Dent. 2016;49:40-5. In this context, water acts like a solvent, leading to plasticization, changing the polymer molecular structure and increasing the mobility of polymer chain segments.1919- Ferracane J. Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater. 2006;22(3):211-22.,3434- Park J, Eslick JJ, Ye Q, Misra A, Spencer P. The influence of chemical structure on the properties in methacrylate-based dentin adhesives. Dent Mater. 2011;27(11):1086-93.

Also, when polymers are immersed in water, some of the components, such as unreacted monomers, are dissolved and released.3333- Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997;76(7):1405-11. In this way, it was a concern that the incorporation of the TM monomer could increase the water sorption/solubility. According to Inagaki, et al.2323- Inagaki LT, Dainezi VB, Alonso RC, Paula AB, Garcia-Godoy F, Puppin-Rontani RM, et al. Evaluation of sorption/solubility, softening, flexural strength and elastic modulus of experimental resin blends with chlorhexidine. J Dent. 2016;49:40-5. (2016), the chemical characteristics of monomers have more influence on the behavior of the materials than on the antimicrobial additive. Providentially, in this study, water sorption and solubility of the materials were not affected by TM presence

Regarding the diametral tensile strength, similar results were found for Control and TM groups, reinforcing that the incorporation of TM does not negatively affect the mechanical properties of the material and that the antibacterial monomer reacted properly with the other monomers of the composite. The immobilization of TM into the resin matrix promotes higher durability and increases the antibacterial capability of the material, without jeopardizing the mechanical properties.1515- Imazato S, Torri M, Tsuchitani Y. Antibacterial effect of composite incorporating triclosan against Streptococcus mutans. J Osaka Univ Dent Sch. 1995;35:5-11. Other study3636- Weng Y, Howard L, Guo X, Chong VJ, Gregory RL, Xie D. A novel antibacterial resin composite for improved dental restoratives. J Mater Sci Mater Med. 2012;23(6):1553-61. evaluated the mechanical properties of a novel furanone-containing antibacterial resin composite and showed that the modified resin composite might be a clinically attractive dental restorative due to its high mechanical strength.

The composite containing the new antibacterial monomer showed satisfactory results since it reduced biofilm accumulation over days and maintained the physic-mechanical properties, suggesting the future possibility of using the TM antimicrobial monomer for clinical application.

Conclusion

Within the limitation of this in vitro study, the results showed that the incorporation of triclosan-methacrylate to resin composites was able to reduce bacterial adhesion of S. mutans and decrease the formation of bacterial biofilm over 10 days. The incorporation of triclosan methacrylate did not significantly affect the surface hardness and roughness, before and after brushing, of the experimental composite. Sorption, solubility and diametral tensile strength of the material were maintained, being promising as a dental resin with intrinsic antibacterial action and suitable properties.

Acknowledgements

This study was supported by Coordination for the Improvement of Higher Education Personnel-CAPES. The authors thank the additional grant from FAPESP (grant #2012/10750-4).

References

  • 1
    - Eltahlah D, Lynch CD, Chadwick BL, Blum IR, Wilson NH. An update on the reasons for placement and replacement of direct restorations. J Dent. 2018;72:1-7.
  • 2
    - Łukomska-Szymańska M, Zarzycka B, Grzegorczyk J, Sokołowski K, Półtorak K, Sokołowski J, et al. Antibacterial properties of calcium fluoride-based composite materials: in vitro study. Biomed Res Int. 2016;2016:1048320.
  • 3
    - Szram A, Póltorak K, Podlewska M, Sokołowski J, Łukomska-Szymańska M. Selected antibacterial components in dental materials - literature review. Prot Stomatol. 2015;65(5):476-81.
  • 4
    - Półtorak K, Podlewska M, Szram A, Sokołowski J, ŁukomskaSzymańska M. Composite materials with antimicrobal properties literature review. e-Dentico. 2016;60(2):84-9.
  • 5
    - Nedeljkovic I, Teughels W, De Munck J, Van Meerbeek B, Van Landuyt KL. Is secondary caries with composites a material-based problem? Dent Mater. 2015;31(11):247-77.
  • 6
    - Farrugia C, Camilleri J. Antimicrobial properties of conventional restorative filling materials and advances in antimicrobial properties of composite resins and glass ionomer cements - a literature review. Dent Mater. 2015;31(4):89-99.
  • 7
    - Yamamoto K, Ohashi S, Taki E, Hirata K. Adherence of oral streptococci to composite resin of varying surface roughness. Dent Mater J. 1996;15(2):201-4.
  • 8
    - Singh C, Dua V, Vyas M, Verma S. Evaluation of the antimicrobial and physical properties of an orthodontic photo-activated adhesive modified with an antiplaque agent: an in vitro study. Indian J Dent Res. 2013;24(6):694-700.
  • 9
    - Neves PB, Agnelli JA, Kurachi C, Souza CW. Addition of silver nanoparticles to composite resin: effect on physical and bactericidal properties in vitro Braz Dent J. 2014;25(2):141-5.
  • 10
    - Imazato S, McCabe JF. Influence of incorporation of antibacterial monomer on curing behavior of a dental composite. J Dent Res. 1994;73(10):1641-5.
  • 11
    - Sharma NC, Galustinas HJ, Qaqish J, Galustians A, Rustogi K, Petrone ME, et al. Clinical effectiveness of a dentifrice containing triclosan and copolymer for controlling breath odor. Am J Dent. 2007;20(2):79-82.
  • 12
    - Lyman FL, Furia T. Toxicology of 2,4,4-trichloro-2-hydroxydiphenyl ether. Ind Med. 1969;38(4):45-52.
  • 13
    - DeSalva JS, Kong BM, Lin YL. Triclosan: a safety profile. Am J Dent. 1989;2:185-96.
  • 14
    - Rathke A, Staude R, Muche R, Haller B. Antibacterial activity of a triclosancontaining resin composite matrix against three common oral bacteria. J Mater Sci Mater Med. 2010;21(11):2971-7.
  • 15
    - Imazato S, Torri M, Tsuchitani Y. Antibacterial effect of composite incorporating triclosan against Streptococcus mutans. J Osaka Univ Dent Sch. 1995;35:5-11.
  • 16
    - Paula AB, Fucio SB, Ambrosano GM, Alonso RC, Sardi JC, Puppin-Rontani RM. Biodegradation and abrasive wear of nano restorative materials. Oper Dent. 2011;36(6):670-7.
  • 17
    - Kakaboura A, Fragouli M, Rahiotis C, Silikas N. Evaluation of surface characteristics of dental composites using profilometry, scanning electron, atomic force microscopy and gloss-meter. J Mater Sci Mater Med. 2007;18(1):155-63.
  • 18
    - Park J, Eslick JJ, Ye Q, Misra A, Spencer P. The influence of chemical structure on the properties in methacrylate-based dentin adhesives. Dent Mater. 2011;27(11):1086-93.
  • 19
    - Ferracane J. Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater. 2006;22(3):211-22.
  • 20
    - Sideridou I, Tserki V, Papanastasiou G. Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylate-based dental resins. Biomaterials. 2003;24(4):655-65.
  • 21
    - Paula AB, Taparelli JR, Alonso RC, Innocentini-Mei LH, Puppin-Rontani RM. Synthesis and application of triclosan methacrylate monomer in resin composites. Clin Oral Investig. 2019;23:965-74.
  • 22
    - Atai M, Watts DC, Atai Z. Shrinkage strain-rates of dental resinmonomer and composite systems. Biomaterials. 2005;26(24):5015-20.
  • 23
    - Inagaki LT, Dainezi VB, Alonso RC, Paula AB, Garcia-Godoy F, Puppin-Rontani RM, et al. Evaluation of sorption/solubility, softening, flexural strength and elastic modulus of experimental resin blends with chlorhexidine. J Dent. 2016;49:40-5.
  • 24
    - Petersen RC. Computational conformational antimicrobial analysis developing mechanomolecular theory for polymer biomaterials in materials science and engineering. Int J Comp Mat Sci Eng. 2014;3(1):1450003.
  • 25
    - Brecx M, Theilade J, Attstrom R. An ultrastructural quantitative study of the significance of microbial multiplication during early dental plaque growth. J Periodont Res. 1983;18(2):177-86.
  • 26
    - Costa J, Adams-Belusko A, Riley K, Ferracane JL. The effect of various dentifrices on surface roughness and gloss of resin composites. J Dent. 2010;38(2):123-8.
  • 27
    - Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997;13(4):258-69.
  • 28
    - Heintze SD, Zellweger G, Cavalleri A, Ferracane J. Influence of the antagonist material on the wear of different composites using two different wear simulation methods. Dent Mater. 2006;22(2):166-75.
  • 29
    - Al Khuraif AA. An in vitro evaluation of wear and surface roughness of particulate filler composite resin after tooth brushing. Acta Odontol Scand. 2014;72(8):977-83.
  • 30
    - Pires-de-Souza FC, Garcia LF, Hamida HM, Casemiro LA. Color stability of composites subjected to accelerated aging after curing using either a halogen or a light emitting diode source. Braz Dent J. 2007;18(2):119-23.
  • 31
    - Ertaş E, Güler AU, Yücel AC, Köprülü H, Güler E. Color stability of resin composites after immersion in different drinks. Dent Mater J. 2006;25(2):371-6.
  • 32
    - Paula AB, Tango RN, Sinhoreti MA, Alves MC, Puppin-Rontani RM. Effect of thickness of indirect restoration and distance from the light-curing unit tip on the hardness of a dual-cured resin cement. Braz Dent J. 2010;21(2):117-22.
  • 33
    - Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997;76(7):1405-11.
  • 34
    - Park J, Eslick JJ, Ye Q, Misra A, Spencer P. The influence of chemical structure on the properties in methacrylate-based dentin adhesives. Dent Mater. 2011;27(11):1086-93.
  • 35
    - Örtengren U, Wellendorf H, Karlsson S, Ruyter IE. Water sorption and solubility of dental composites and identification of monomers released in an aqueous environment. J Oral Rehabil. 2001;28(12):1106-15.
  • 36
    - Weng Y, Howard L, Guo X, Chong VJ, Gregory RL, Xie D. A novel antibacterial resin composite for improved dental restoratives. J Mater Sci Mater Med. 2012;23(6):1553-61.

Publication Dates

  • Publication in this collection
    09 Sept 2019
  • Date of issue
    2019

History

  • Received
    20 June 2018
  • Reviewed
    08 Oct 2018
  • Accepted
    28 Nov 2018
Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil
E-mail: jaos@usp.br