Acessibilidade / Reportar erro

Transcatheter Aortic Valve Replacement: The Experience of One Brazilian Health Care Center

Abstract

Objective:

Transcatheter aortic valve replacement has been an alternative to invasive treatment for symptomatic severe aortic stenosis in high risk patients. The primary endpoint was 30-day and 1-year mortality from any cause. Secondary endpoints were to compare the clinical and echocardiographic variation pre-and post- transcatheter aortic valve replacement, and the occurrence of complications throughout a 4-year follow-up period.

Methods:

This prospective cohort, nestled to a multicenter study (Registro Brasileiro de Implante de Bioprótese por Cateter), describes the experience of a public tertiary center in transcatheter aortic valve replacement. All patients who underwent this procedure between October 2011 and February 2016 were included.

Results:

Fifty-eight patients underwent transcatheter aortic valve replacement. The 30-day all-cause mortality was 5.2% (n=3) and after 1 year was 17.2% (n=10). A significant improvement in New York Heart Association functional classification was observed when comparing pre-and post- transcatheter aortic valve replacement (III or IV 84.4% versus 5.8%; P<0.001). A decline in peak was observed (P<0.001) and mean (P<0.001) systolic transaortic gradient. The results of peak and mean post-implant transaortic gradient were sustained after one year (P=0.29 and P=0.36, respectively). Left ventricular ejection fraction did not change significantly during follow-up (P=0.41). The most frequent complications were bleeding (28.9%), the need for permanent pacemaker (27.6%) and acute renal injury (20.6%).

Conclusion:

Mortality and complications in this study were consistent with worldwide experience. Transcatheter aortic valve replacement had positive clinical and hemodynamic results, when comparing pre-and post-procedure, and the hemodynamic profile of the prosthesis was sustained throughout follow-up.

Keywords:
Transcatheter Aortic Valve Replacement; Heart Valve Prosthesis Implantation; Aortic Valve Stenosis/surgery

Abbreviations, acronyms & symbols BNP = Brain natriuretic peptide EuroSCORE I = European System for Cardiac Operative Risk Evaluation FC = Functional classification LVED = Left ventricle end-diastolic diameter LVEF = Left ventricular ejection fraction TAVR = Transcatheter aortic valve replacement TEE = Transesophageal echocardiogram TTE = Transthoracic echocardiogram VARC-2 = Valve Academic Research Consortium-2

INTRODUCTION

Symptomatic patients with severe aortic stenosis have limited functionality and survival. For these patients, valve replacement is the treatment of choice. However, the treatment for those with high or prohibitive surgical risk was restricted to medication, as in pre-surgery era. After the advent of transcatheter aortic valve replacement (TAVR) in 2002, symptomatic patients with severe aortic stenosis and high risk have an alternative intervention option, with survival and functional improvement. Its use is nowadays spread worldwide, including in developing countries[11 Yousef A, Froeschl M, Hibbert B, Burwash IG, Labinaz M. Transcatheter aortic valve implantation: current and evolving indications. Can J Cardiol. 2016;32(2):266-9.,22 Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, et al.; PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364(23):2187-98.]. The TAVR experience of public tertiary health care center was described in this prospective cohort.

The primary endpoint was a 1-year mortality due to any cause. Secondary endpoints were to compare functional classification (FC), peak and mean transaortic systolic gradient and left ventricular ejection fraction (LVEF), when comparing before and after the procedure. In addition, the present study aimed to evaluate the complications related to the procedure.

METHODS

This is a prospective cohort nestled to a multicenter national study (Registro Brasileiro de Implante de Bioprótese por Cateter)[33 Brito FS, Carvalho LA, Sarmento-Leite R, Mangione JA, Lemos P, Siciliano A, et al.; Brazilian TAVI Registry investigators. Outcomes and predictors of mortality after transcatheter aortic valve implantation: results of the Brazilian registry. Catheter Cardiovasc Interv. 2015;85(5):E153-62.]. The patients included underwent TAVR between December 2011 and January 2016, at a Brazilian public tertiary health care center.

The patient selection protocol started with individuals with severe aortic stenosis or dysfunctional biologic aortic valve being evaluated by a multidisciplinary team (formed by cardiologists, cardiac surgeons and nurses). TAVR was considered as treatment when they presented high or prohibitive surgical risk.

The TAVR was indicated when at least one of the following criteria was present: A-patients were considered as high risk, with European System for Cardiac Operative Risk Evaluation (EuroSCORE I) equal or higher than 15%; or B-the presence of frailty (identified using subjective criteria by the TAVR team, as difficulty in walking and low body weight)[44 Hemmann K, Sirotina M, Rosa S, Ehrlich JR, Fox H, Weber J, et al. The STS score is the strongest predictor of long-term survival following transcatheter aortic valve implantation, whereas access route (transapical versus transfemoral) has no predictive value beyond the periprocedural phase. Interact Cardiovasc Thorac Surg. 2013;17(2):359-64.]; or C-porcelain aorta (circumferential calcification of ascending aorta, as seen on computer tomography images) was considered as prohibitive risk for conventional valve replacement surgery.

Eligible patients were evaluated according to New York Heart Association FC, and laboratory parameters before the TAVR procedure. The exams included blood analysis (hemoglobin, creatinine, platelets, brain natriuretic peptide (BNP), electrocardiogram, transthoracic echocardiogram (TTE) and coronariography. Peak and mean transaortic gradients, presence of aortic regurgitation, aortic valve area, left ventricle end-diastolic diameter (LVED) and LVEF (Teicholz method) were evaluated according to American Echocardiography Society[55 Holmes DR Jr, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, et al.; American Heart Association; American Society of Echocardiography; European Association for Cardio-Thoracic Surgery; Heart Failure Society of America; Mended Hearts; Society of Cardiovascular Anesthesiologists; Society of Cardiovascular Computed Tomography; Society for Cardiovascular Magnetic. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement: developed in collaboration with the American Heart Association, American Society of Echocardiography, European Association for Cardio-Thoracic Surgery, Heart Failure Society of America, Mended Hearts, Society of Cardiovascular Anesthesiologists, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance. J Thorac Cardiovasc Surg. 2012;144(3):e29-84.].

All patients were studied before TAVR by angiotomography images of total aorta, subclavian, femoral and iliac arteries, in order to evaluate eligibility and to choose the site of catheter insertion (femoral, transapical or other), the valve model and size. Exclusion criteria were incompatible size between available prosthesis and the valve ring size (according to angiotomography images), the presence of clot in the ventricle, LVEF < 20% on TTE or estimated survival less than one year.

The valve models used were those available at the time of initial evaluation. The valve size was chosen according to valve ring size on angiotomography. Femoral artery was the preferential access. If not possible, an alternative access was obtained. TAVR was performed under general anesthesia or sedation anesthesia, and accompanied by transesophageal echocardiogram (TEE).

TAVR to treat a dysfunctional biologic prosthetic aortic valve, was called as valve-in-valve procedure and was performed under the same criteria as listed above.

After TAVR procedure, laboratory data was collected in the first 72 hours, electrocardiogram was performed daily, and one TTE was obtained before patient discharge, until 7 days after the procedure.

Functional classification, electrocardiogram and TTE were registered in 30 days, six months, one year and two years after TAVR.

Complications were registered as Valve Academic Research Consortium-2 (VARC-2) definitions[66 Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J. 2011;32(2):205-17.], as the mortality causes classification. Non identified cause was considered as cardiovascular cause.

Statistical Analysis

Kolmogorov-Smirnov and Shapiro-Wilk tests were used to check distribution pattern. Continuous variables with normal distribution were presented as mean ± standard deviation, otherwise were presented as median and interquartile range and were submitted to Student t test or Mann-Whitney. Categorical variables were presented as frequencies (number, percentage and confidence interval) and compared through the chi-square and Fisher exact test. Friedman and Cochran Q were used for paired tests and ANOVA to repeated measures. Kaplan Meier survival curve estimated the survival rate free of events in this population and its censored cases were deaths or the last follow-up. Data were analyzed with the R® software 3.1.0 through Extension EZR 1.27 do R Commander 2.1-4. It was assumed 5% alpha error and P values ≤ 0.05 were considered significant. This study was registered in the local Research Ethics Committee, according to the Declaration of Helsinki. All participants signed a consent form.

RESULTS

Fifty-eight patients were treated with TAVR. Baseline characteristics are presented in Tables 1 and 2.

Table 1
Baseline clinical profile.
Table 2
Baseline and after transcatheter aortic valve replacement echocardiogram values.

General anesthesia was employed in 51 (87.9%) cases. Sedation and local anesthesia were performed in 7 (12.1%) patients and TEE in 53 (91.4%) procedures. The main access was transfemoral (n=47; 81%). The alternative access used were transapical (n=7; 12.1%), transaortic (n=3; 5.2%), and subclavian artery (n=1; 1.7%). Self-expandable valve CoreValve® (Medtronic Inc., Minneapolis, MN, USA) was implanted in 40 (68.9%) patients, balloon-expandable valve SAPIEN-XT® (Edwards Lifesciences, Irvine, CA, USA) in 11 (19%) and Inovare® (Braile Biomedica, São José do Rio Preto, SP, Brazil) in seven (12.1%) cases.

Seven (12.1%) patients had dysfunctional biological aortic prosthesis and the procedures were valve-in-valve. All of them had an Inovare® model implanted surgically via transapical access. Echocardiographic and laboratory data after TAVR are shown in Table 2.

In this cohort, the all-cause mortality was 17.2% (n=10) within the follow-up of 1 year. The mortality within 30 days was 5.2% (n=3) and was considered related to the procedure. Two of them had apical access: their mortality causes were due to life threatening bleeding for both, beside major ischemic stroke for one of them. The third patient that immediately died after the procedure, had atrioventricular block due to contiguous complication.

The late mortality occurred in seven cases, five of them related to cardiovascular causes and the others related to noncardiovascular causes. Among the cardiovascular causes were: one had major ischemic stroke; three of them had sudden death or non-identified cause; and one death was related to the procedure (prosthesis migration and major bleeding). The noncardiovascular related causes were sepsis and rupture of preexistent esophageal varices.

Among the patients that died (n=10), three had moderate or severe aortic regurgitation on the echocardiogram (until seven days after TAVR). They died, each one, 10.7 and 6.5 months (moderate regurgitation) and 1.5 month (severe regurgitation) after the procedure.

Apical access was used to treat dysfunctional bioprosthesis: seven valve-in-valve procedures, all of them using Inovare® model. Among these subgroup, two early deaths were registered (within the first day after TAVR). Both had life threatening bleeding, renal injury and received second valve during the procedure, due to related first valve failure. The first patient had also ventricular perforation and atrioventricular block. The second had also left bundle block and major ischemic stroke. One patient died after the 30th day (late mortality) related to a noncardiovascular cause. The other four valve-in-valve patients did not have any complications.

Survival analysis is represented by Kaplan Meier curve in Figure 1. Mean follow-up time was 6.4 [1.55-12.9] months and maximum 33.8 months in this cohort.

Fig. 1
Kaplan-Meier survival curve*.

95% CI - - - - - - Survive ____ + Censored (*) Censored cases represent last follow-up visit.


Clinical evolution of FC is presented in Figure 2. The prevalence of FC III or IV pre-TAVR was 84.5% (n=49 of 58) compared to 30 days that was 14.8% (n=8 of 54; P<0.001), six months 9.1% (n=4 of 44; P<0.001); one year 10.8% (n=4 of 37; P<0.001); and two years 10.5% (n=2 of 19; P<0.001).

Fig. 2
New York Heart Association functional classification during follow-up after transcatheter aortic valve replacement*.

* Losses were due to deaths or the last follow-up in timeline.


Echocardiographic evolution by transaortic gradient and LVEF analysis before and after TAVR are shown in Figure 3. Complications are presented in Table 3.

Fig. 3
Left ventricular ejection fraction, transaortic peak, and mean gradient evolution (mmHg).

LVEF=Left ventricle ejection fraction; Transaortic (*) Peak and (**) mean gradients variability before and after TAVR, before hospital discharge. Transaortic (§) mean and (§§) peak gradient after TAVR


Table 3
Complications during the 4-year follow-up period according to Valve Academic Research Consortium-2.

DISCUSSION

This prospective cohort describes the experience of a public tertiary center in TAVR.

The small population and the single center analysis are limitations of this study. Frailty was considered according to subjective impressions of a multidisciplinary team and may interfere on the reproducibility of selection criteria.

Mean age in this cohort was similar to main published registries. Mean EuroSCORE was inferior comparing to previous studies. However, porcelain aorta was more prevalent in this population[77 Eltchaninoff H, Prat A, Gilard M, Leguerrier A, Blanchard D, Fournial G, et al. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur Heart J. 2011;32(2):191-7.

8 Lefèvre T, Kappetein AP, Wolner E, Nataf P, Thomas M, Schächinger V, et al.; PARTNER EU Investigator Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur Heart J. 2011;32(2):148-57.
-99 Perin MA, Brito Jr FS, Almeida BO, Pereira MA, Abizaid A, Tarasoutchi F, et al. Percutaneous aortic valve replacement for the treatment of aortic stenosis: early experience in Brazil. Arq Bras Cardiol. 2009;93(3):299-306.]. As porcelain aorta is a formal surgery contraindication and it could have impacted on EuroSCORE profile of this population[77 Eltchaninoff H, Prat A, Gilard M, Leguerrier A, Blanchard D, Fournial G, et al. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur Heart J. 2011;32(2):191-7.].

General anesthesia was preferred over sedation and local anesthesia. Although recent published studies reveal the opposite, this scenario is similar to publications of initial experiences[1010 Mayr NP, Michel J, Bleiziffer S, Tassani P, Martin K. Sedation or general anesthesia for transcatheter aortic valve implantation (TAVI). J Thorac Dis. 2015;7(9):1518-26.].

As published in Brazilian[33 Brito FS, Carvalho LA, Sarmento-Leite R, Mangione JA, Lemos P, Siciliano A, et al.; Brazilian TAVI Registry investigators. Outcomes and predictors of mortality after transcatheter aortic valve implantation: results of the Brazilian registry. Catheter Cardiovasc Interv. 2015;85(5):E153-62.] and international literature[1111 Webb JG, Chandavimol M, Thompson CR, Ricci DR, Carere RG, Munt BI, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation. 2006;113(6):842-50.,1212 Hayashida K, Lefèvre T, Chevalier B, Hovasse T, Romano M, Garot P, et al. Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv. 2011;4(8):851-8.], transfemoral was the main used access. Apical access was used in all valve-in-valve procedure (seven cases) and contributed 20% (two cases) to all-mortality in this cohort.

In cases of dysfunctional aortic bioprosthesis, conventional valve replacement is associated with higher risk compared to the first cardiac surgery and may contraindicate the surgery intervention[1313 Gaia DF, Couto A, Breda JR, Ferreira CB, Macedo MT, Gimenes MV, et al. Transcatheter aortic valve-in-valve implantation: a selection change? Rev Bras Cir Cardiovasc. 2012;27(3):355-61.]. Valve-in-valve has shown as a safe alternative and has shown adequate hemodynamic performance[1414 Pasic M, Unbehaun A, Dreysse S, Buz S, Drews T, Kukucka M, et al. Transapical aortic valve implantation after previous aortic valve replacement: clinical proof of the "valve-in-valve" concept. J Thorac Cardiovasc Surg. 2011;142(2):270-7.,1515 Gaia DF, Palma JH, Ferreira CBND, Souza JAM, Gimenes MV, Macedo MT, et al. Transcatheter aortic valve implantation: results of the current development and implantation of a new Brazilian prosthesis. Rev Bras Cir Cardiovasc. 2011;26(3):338-47.]. In this cohort, valve-in-valve procedures were not analyzed apart and can interfere on results, mainly on transaortic gradients.

Mortality was consistent with literature. Brazilian registry[33 Brito FS, Carvalho LA, Sarmento-Leite R, Mangione JA, Lemos P, Siciliano A, et al.; Brazilian TAVI Registry investigators. Outcomes and predictors of mortality after transcatheter aortic valve implantation: results of the Brazilian registry. Catheter Cardiovasc Interv. 2015;85(5):E153-62.] had 30 days and one year mortality of 9.1% and 21.5%, respectively. Data presented in SOURCE registry[1616 Thomas M, Schymik G, Walther T, Himbert D, Lefèvre T, Treede H, et al. One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2011;124(4):425-33.] was 6.3% e 10.3% (transfemoral and transapical access, respectively); on ADVANCE trial[1717 Wood S. TAVI registry updates ADVANCE the field, raise hopes for lower stroke rates. [cited 2017 May 12]. from: http://www.theheart.org/article/1374163.do 12 June 2012
http://www.theheart.org/article/1374163....
] was 4.5%; on FRANCE trial[77 Eltchaninoff H, Prat A, Gilard M, Leguerrier A, Blanchard D, Fournial G, et al. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur Heart J. 2011;32(2):191-7.], 12.7%; and FRANCE 2 trial[1818 Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J; FRANCE 2 Investigators. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012;366(18):1705-15.], 9.7%; survival analysis after one year in PARTNER registry[88 Lefèvre T, Kappetein AP, Wolner E, Nataf P, Thomas M, Schächinger V, et al.; PARTNER EU Investigator Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur Heart J. 2011;32(2):148-57.] was 76.9%, in SOURCE[1616 Thomas M, Schymik G, Walther T, Himbert D, Lefèvre T, Treede H, et al. One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2011;124(4):425-33.] was 76.1%, in FRANCE 2[1818 Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J; FRANCE 2 Investigators. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012;366(18):1705-15.] 81.6%, and Figulla et al.[1919 Figulla L, Neumann A, Figulla HR, Kahlert P, Erbel R, Neumann T. Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature. Clin Res Cardiol. 2011;100(4):265-76.] showed 75.9%.

Aortic regurgitation of at least moderate level in this cohort was 14.81%. Although TEE had been performed during most procedures[2020 George JC, Varghese V, Dangas G, Popma JJ. Transcatheter aortic valve implantation: lessons from the PARTNER (Placement of Aortic Transcatheter Valves) trial. JACC Cardiovasc Interv. 2011;4(1):132-3.,2121 De Jaegere PP, Piazza N, Galema TW, Otten A, Soliman OI, Van Dalen BM, et al. Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis. EuroIntervention. 2008;4(3):351-7.], these data were not available for analysis. The use of TTE data done until seven days after the procedure as the first echocardiogram after TAVR can limit comparisons among other studies echocardiogram data, since TEE or TTE done in the operating room is the standard in literature. To avoid further data interference, two cases without echocardiogram data before the discharge were excluded from the population analyzed.

Recently, the new generation of the balloon-expandable valve system has shown less occurrence of aortic regurgitation and pacemaker implantation[2222 Lu Q, Pei Y, Wu H, Wang Z, Zaiping J. Transcatheter aortic valve implantation with balloon-expandable valve: early experience from China. Rev Bras Cir Cardiovasc. 2015;30(4):425-32.]. This cohort had clinical endpoints and complications defined by VARC-2[2323 Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Thorac Cardiovasc Surg. 2013;145(1):6-23.]. Accordingly, results should be carefully compared to the literature, since the same criteria and definitions should have been used for comparisons.

Hemorrhagic complications and pacemaker implantation were the main complications in this study. Comparing to literature, hemorrhagic complications were more frequent and acute renal injury occurrence was less frequent in this cohort, although there is a large variation of criteria used among different studies. Pacemaker implantation was similar to the literature, consistent to the registries which indicate that this complication is more frequent among the self-expandable valve model CoreValve® model[2424 Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585-95.

25 Amabile N, Azmoun A, Ghostine S, Ramadan R, Haddouche Y, Raoux F, et al. Incidence, predictors and prognostic value of serious hemorrhagic complications following transcatheter aortic valve implantation. Int J Cardiol. 2013;168(1):151-6.
-2626 Barbanti M, Latib A, Sgroi C, Fiorina C, De Carlo M, Bedogni F, et al. Acute kidney injury after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis: results from a large multicentre Italian research project. EuroIntervention. 2014;10(1):133-40.]. In this cohort, this model was used in almost 70% of the procedures.

The post-TAVR echocardiogram (until seven days after the procedure) data were not available in four patients. Two of them died during the procedure. The other two had post-TAVR echocardiogram registries 30 days after the procedure (one with moderate aortic regurgitation and the other without aortic regurgitation). Thus, among the 54 patients analyzed, one (1.85%) had severe, seven (12.96%) had moderate, twenty-three (42.59%) had mild and twenty-three (42.59%) did not have aortic regurgitation on the echocardiogram before hospital discharge.

Also consistent with literature, significant, lasting clinical and echocardiographic improvement was registered[2727 Généreux P, Head SJ, Van Mieghem NM, Kodali S, Kirtane AJ, Xu K, et al. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol. 2012;59(25):2317-26.]. FC improvement could be seen since the first follow-up appointment, changing the profile of III and IV predominance to I and II. Transaortic gradient, peak and mean, fall immediately, maintaining this pattern during follow-up, as in previous studies[2121 De Jaegere PP, Piazza N, Galema TW, Otten A, Soliman OI, Van Dalen BM, et al. Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis. EuroIntervention. 2008;4(3):351-7.,2626 Barbanti M, Latib A, Sgroi C, Fiorina C, De Carlo M, Bedogni F, et al. Acute kidney injury after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis: results from a large multicentre Italian research project. EuroIntervention. 2014;10(1):133-40.]. LVEF did not change significantly in this study, however, published studies show improvement in dilated cardiomyopathy after TAVR[2626 Barbanti M, Latib A, Sgroi C, Fiorina C, De Carlo M, Bedogni F, et al. Acute kidney injury after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis: results from a large multicentre Italian research project. EuroIntervention. 2014;10(1):133-40.,2727 Généreux P, Head SJ, Van Mieghem NM, Kodali S, Kirtane AJ, Xu K, et al. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol. 2012;59(25):2317-26.].

CONCLUSION

Mortality and complications in this study were consistent with literature. The more frequent complications in this cohort were hemorrhagic complications and pacemaker implantation. TAVR had positive clinical and hemodynamic results for this population, when comparing pre-and post-procedure. The prosthesis hemodynamic profile was sustained and LVEF did not change significantly during follow-up.

Authors' roles & responsibilities FSA Substantial contributions to the conception or design of the work; or the acquisition, analysis, or interpretation of data for the work; drafting the work or revising it critically for important intellectual content; final approval of the version to be published MGC Substantial contributions to the conception or design of the work; or the acquisition, analysis, or interpretation of data for the work; final approval of the version to be published DHGP Substantial contributions to the conception or design of the work; or the acquisition, analysis, or interpretation of data for the work; final approval of the version to be published ASF Agreement to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved; final approval of the version to be published LHJB Agreement to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved; final approval of the version to be published APCM Agreement to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved; final approval of the version to be published VGS Agreement to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved; final approval of the version to be published BMM Substantial contributions to the conception or design of the work; or the acquisition, analysis, or interpretation of data for the work; final approval of the version to be published AJOM Substantial contributions to the conception or design of the work; or the acquisition, analysis, or interpretation of data for the work; final approval of the version to be published CW Agreement to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved; final approval of the version to be published ASC Drafting the work or revising it critically for important intellectual content; final approval of the version to be published DABK Drafting the work or revising it critically for important intellectual content; final approval of the version to be published
  • This study was carried out at the Instituto Nacional de Cardiologia (INC), Rio de Janeiro, RJ, Brazil.
  • No financial support.

REFERENCES

  • 1
    Yousef A, Froeschl M, Hibbert B, Burwash IG, Labinaz M. Transcatheter aortic valve implantation: current and evolving indications. Can J Cardiol. 2016;32(2):266-9.
  • 2
    Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, et al.; PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364(23):2187-98.
  • 3
    Brito FS, Carvalho LA, Sarmento-Leite R, Mangione JA, Lemos P, Siciliano A, et al.; Brazilian TAVI Registry investigators. Outcomes and predictors of mortality after transcatheter aortic valve implantation: results of the Brazilian registry. Catheter Cardiovasc Interv. 2015;85(5):E153-62.
  • 4
    Hemmann K, Sirotina M, Rosa S, Ehrlich JR, Fox H, Weber J, et al. The STS score is the strongest predictor of long-term survival following transcatheter aortic valve implantation, whereas access route (transapical versus transfemoral) has no predictive value beyond the periprocedural phase. Interact Cardiovasc Thorac Surg. 2013;17(2):359-64.
  • 5
    Holmes DR Jr, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, et al.; American Heart Association; American Society of Echocardiography; European Association for Cardio-Thoracic Surgery; Heart Failure Society of America; Mended Hearts; Society of Cardiovascular Anesthesiologists; Society of Cardiovascular Computed Tomography; Society for Cardiovascular Magnetic. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement: developed in collaboration with the American Heart Association, American Society of Echocardiography, European Association for Cardio-Thoracic Surgery, Heart Failure Society of America, Mended Hearts, Society of Cardiovascular Anesthesiologists, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance. J Thorac Cardiovasc Surg. 2012;144(3):e29-84.
  • 6
    Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J. 2011;32(2):205-17.
  • 7
    Eltchaninoff H, Prat A, Gilard M, Leguerrier A, Blanchard D, Fournial G, et al. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur Heart J. 2011;32(2):191-7.
  • 8
    Lefèvre T, Kappetein AP, Wolner E, Nataf P, Thomas M, Schächinger V, et al.; PARTNER EU Investigator Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur Heart J. 2011;32(2):148-57.
  • 9
    Perin MA, Brito Jr FS, Almeida BO, Pereira MA, Abizaid A, Tarasoutchi F, et al. Percutaneous aortic valve replacement for the treatment of aortic stenosis: early experience in Brazil. Arq Bras Cardiol. 2009;93(3):299-306.
  • 10
    Mayr NP, Michel J, Bleiziffer S, Tassani P, Martin K. Sedation or general anesthesia for transcatheter aortic valve implantation (TAVI). J Thorac Dis. 2015;7(9):1518-26.
  • 11
    Webb JG, Chandavimol M, Thompson CR, Ricci DR, Carere RG, Munt BI, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation. 2006;113(6):842-50.
  • 12
    Hayashida K, Lefèvre T, Chevalier B, Hovasse T, Romano M, Garot P, et al. Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv. 2011;4(8):851-8.
  • 13
    Gaia DF, Couto A, Breda JR, Ferreira CB, Macedo MT, Gimenes MV, et al. Transcatheter aortic valve-in-valve implantation: a selection change? Rev Bras Cir Cardiovasc. 2012;27(3):355-61.
  • 14
    Pasic M, Unbehaun A, Dreysse S, Buz S, Drews T, Kukucka M, et al. Transapical aortic valve implantation after previous aortic valve replacement: clinical proof of the "valve-in-valve" concept. J Thorac Cardiovasc Surg. 2011;142(2):270-7.
  • 15
    Gaia DF, Palma JH, Ferreira CBND, Souza JAM, Gimenes MV, Macedo MT, et al. Transcatheter aortic valve implantation: results of the current development and implantation of a new Brazilian prosthesis. Rev Bras Cir Cardiovasc. 2011;26(3):338-47.
  • 16
    Thomas M, Schymik G, Walther T, Himbert D, Lefèvre T, Treede H, et al. One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2011;124(4):425-33.
  • 17
    Wood S. TAVI registry updates ADVANCE the field, raise hopes for lower stroke rates. [cited 2017 May 12]. from: http://www.theheart.org/article/1374163.do 12 June 2012
    » http://www.theheart.org/article/1374163.do
  • 18
    Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J; FRANCE 2 Investigators. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012;366(18):1705-15.
  • 19
    Figulla L, Neumann A, Figulla HR, Kahlert P, Erbel R, Neumann T. Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature. Clin Res Cardiol. 2011;100(4):265-76.
  • 20
    George JC, Varghese V, Dangas G, Popma JJ. Transcatheter aortic valve implantation: lessons from the PARTNER (Placement of Aortic Transcatheter Valves) trial. JACC Cardiovasc Interv. 2011;4(1):132-3.
  • 21
    De Jaegere PP, Piazza N, Galema TW, Otten A, Soliman OI, Van Dalen BM, et al. Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis. EuroIntervention. 2008;4(3):351-7.
  • 22
    Lu Q, Pei Y, Wu H, Wang Z, Zaiping J. Transcatheter aortic valve implantation with balloon-expandable valve: early experience from China. Rev Bras Cir Cardiovasc. 2015;30(4):425-32.
  • 23
    Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Thorac Cardiovasc Surg. 2013;145(1):6-23.
  • 24
    Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585-95.
  • 25
    Amabile N, Azmoun A, Ghostine S, Ramadan R, Haddouche Y, Raoux F, et al. Incidence, predictors and prognostic value of serious hemorrhagic complications following transcatheter aortic valve implantation. Int J Cardiol. 2013;168(1):151-6.
  • 26
    Barbanti M, Latib A, Sgroi C, Fiorina C, De Carlo M, Bedogni F, et al. Acute kidney injury after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis: results from a large multicentre Italian research project. EuroIntervention. 2014;10(1):133-40.
  • 27
    Généreux P, Head SJ, Van Mieghem NM, Kodali S, Kirtane AJ, Xu K, et al. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol. 2012;59(25):2317-26.

Publication Dates

  • Publication in this collection
    Jan-Feb 2018

History

  • Received
    10 June 2017
  • Accepted
    26 Sept 2017
Sociedade Brasileira de Cirurgia Cardiovascular Rua Afonso Celso, 1178 Vila Mariana, CEP: 04119-061 - São Paulo/SP Brazil, Tel +55 (11) 3849-0341, Tel +55 (11) 5096-0079 - São Paulo - SP - Brazil
E-mail: bjcvs@sbccv.org.br