Perimetria computadorizada em pacientes glaucomatosos com visão sub-normal

Computerized perimetry in low vision glaucomatous patients

Paulo Eduardo Casarin Comegno1 

Vital Paulino Costa2 

Silvia Alves R. F. Silva3 

Newton Kara-José4 

1Médico Assistente Voluntário do Setor de Glaucoma do Hospital das Clínicas da UNICAMP.

2Chefe do Setor de Glaucoma do Hospital das Clínicas da UNICAMP. Pós-graduando (Doutorado) da Faculdade de Medicina da Universidade de São Paulo. Médico Assistente do Hospital das Clínicas da Faculdade de Medicina da USP.

3Técnica de Enfermagem do Ambulatório de Oftalmologia do Hospital das Clínicas da UNICAMP.

4Professor Titular do Departamento de Oftalmologia da Faculdade de Ciências Médicas da UNICAMP. Professor Associado da Faculdade de Medicina da USP.


RESUMO

O objetivo deste estudo é analisar a possibilidade da utilização da perimetria computadorizada em pacientes glaucomatosos com acuidade visual inferior à 200/400.

Foram examinados 33 olhos de 33 pacientes (21 com AV = CD e 12 com AV = MM), utilizando-se o programa 24-2 do perímetro da Humphrey, inicialmente com estímulo III e depois com estímulo V.

Doze pacientes não conseguiram realizar nenhum dos exames (todos com AV = MM). Dezenove pacientes conseguiram realizar os dois exames, enquanto dois pacientes conseguiram realizar apenas o exame com estímulo V. Dos 19 pacientes que realizaram os dois exames, 15 (68,4%) se sentiram mais confortáveis realizando o exame com estímulo V.

A conclusão deste estudo é que é possível a realização da perimetria computadorizada em pacientes glaucomatosos com defeitos avançados de campo visual e AV inferior à 20/400.

Palavras-chave: Perimetria computadorizada: Estímulo luminoso; Glaucoma; Visão sub-normal

SUMMARY

The purpose of this study is to investigate the possibility of using the computerized perimetry in glaucomatous patients with VA less than 20/400.

Thirty three eyes of 33 patients (21 with VA = CF and 12 with VA = HM), underwent automated perimetry (Humphrey 24-2 program), initially with stimulus III and after with stimulus V.

Twelve patients were not able to complete neither examinations (all of them with VA = HHM). Nineteen patients were able to complete both examinations, while two patients were able to complete only the examination with stimulus V. Among the nineteen patients that carried out both examinations, fifteen (68,4%) felt themselves more confortable during the examination with stimulus V.

We conclude that computerized perimetry is possible in glaucomatous patients with advanced visual field defects and VA less than 20/400.

Texto completo disponível apenas em PDF.

REFERÊNCIAS BIBLIOGRÁFICAS

1 LYNN, J. R. - Correlation of pathogenesis, anatomy and patterns of visual field loss in glaucoma. In: Symposium on Glaucoma. Trans New Orleans Acad. Ophthalmol. Saint Louis, C. V. Mosby Co, 1975. 151-189. [ Links ]

2 KATZ, J.; TIELSCH, J. M., QUIGLEY H. A.; SOMMER A. - Automated Perimetry detects visual field loss before manual Goldmann perimetry. Ophthalmology, 102: 21-26, 1995. [ Links ]

3 ANDERSON, D. R. - Automated Static Perimetry. Saint Louis, C. V. Mosby Co, 1992. p 25. [ Links ]

4 CHOPLIN N. T.; SHERWOOD M. B.; and SPAETH G. L. - The effect of stimulus size on the easured threshold values in automated perimetry, Ophthalmology, 97: 371-374, 1990. [ Links ]

5 MALTA, R. F. S. - Apostila do Curso Básico de Glaucoma para residentes do Hospital das Clínicas da UNICAMP 1993. [ Links ]

6 HEIJIL A.; LINDGREN A.; and LINDGREN G: Test - retest variability in glaucomatous visual fields, J. Ophthalmol, 108: 130-135, 1989. [ Links ]

7 HOLMIN C. and KRAKAU C. E. T. - Variability of glaucomatous visual field defects in computadorized perimetry, Albrecht von Graefes Arch Klin Exp Ophthalmol, 210: 235-250, 1979. [ Links ]

8 WERNER E. B.; PETRIG B.; KRUPIN T. and BISHOP K. I. - Variability of automated visual fields in clinically stable glaucoma patients Invest Ophthalmol Vis SCI, 30: 1083-1089, 1989. [ Links ]

9 ANDERSON D. R. - Automated Static Perimetry - Saint Louis, C. V. Mosby Co, 1992 p 180-181. [ Links ]

Creative Commons License Este é um artigo publicado em acesso aberto (Open Access) sob a licença Creative Commons Attribution, que permite uso, distribuição e reprodução em qualquer meio, sem restrições desde que o trabalho original seja corretamente citado.