Acessibilidade / Reportar erro

Fifteen years of experience with frontalis suspension using polytetrafluoroethylene (Gore-Tex®) suture in blepharoptosis repair

15 anos de experiência em suspensão frontal com fio de politetrafluoretileno (Gore-Tex®) na correção de ptose palpebral

ABSTRACT

Purpose:

To review the outcomes of frontalis suspension surgeries with the use of polytetrafluoroethylene in patients with blepharoptosis.

Methods:

A retrospective observational study analyzed the outcomes of frontalis suspension surgeries performed in a single institution from 2003 to 2018. All procedures were performed with closed incision and single pentagon techniques. Outcomes were classified as satisfactory or unsatisfactory, with satisfactory defined as a margin reflex distance of >3 mm and <1 mm between eyelids and unsatisfactory as hypocorrection, surgical complications, and asymmetry.

Results:

We included a total of 76 eyelids from 52 patients in our study. Within a mean postoperative follow-up of 16.8 ± 18.5 months (range, 3-95), 59 (77.6%) eyelids had a satisfactory outcome, and 17 (22.4%) were unsatisfactory (8 cases of asymmetry, 3 granulomas, 3 suture extrusions, 2 abscesses, and 1 case of cellulitis). Nine eyelids from the unsatisfactory group required reoperation. Among the patients with a follow-up of ³12 months (38 surgeries), lasting results were observed in most eyelids, except for 2 late-onset suture extrusions.

Conclusion:

The use of polytetrafluoroethylene in frontalis suspension surgery was shown to be predictable, safe, and lasting. Our findings support previous studies that have shown adequate functional results and low complication rates.

Keywords:
Eyelids/surgery; Blepharoptosis/surgery; Blepharo plasty/methods; Polytetrafluoroethylene/utilization; Suture; Pos to perative period

RESUMO

Objetivo:

Revisar os resultados de cirurgias de sus pensão ao músculo frontal com o uso de fio de politetrafluoretileno em pacientes com blefaroptose.

Métodos:

Em um estudo observacional retrospectivo, foram analisados os resultados das cirurgias de músculo frontal de uma instituição, realizadas entre 2003 e 2018. Todos os procedimentos foram realizados com incisão fechada e técnica de pentágono. Os desfechos foram classificados como satisfatórios ou insatisfatórios com definição satisfatória definida como distância margem-reflexo >3mm e <1mm entre as pálpebras e insatisfatória como hipocorreção, complicações cirúrgicas e assimetria.

Resultados:

Incluímos um total de 76 pálpebras de 52 pacientes em nosso estudo. Com um tempo médio de seguimento pós-operatório de 16,8 ± 18,5 meses (intervalo 3-95), 59 (77,6%) pálpebras apresentaram desfecho satisfatório e 17 (22,4%) insatisfatórios (8 casos de assimetria, 3 granulomas, 3 extrusões de sutura, 2 abscessos e 1 caso de celulite). Nove pálpebras do grupo insatisfatório necessitaram de reoperação. Entre os pacientes com seguimento ³12 meses (38 cirurgias), resultados duradouros foram observados na maioria dos casos, exceto por 2 extrusões de sutura de surgimento tardio.

Conclusão:

O uso de politetrafluoretileno na cirurgia de músculo frontal mostrou ser previsível, seguro e duradouro, Nossos achados corroboram com estudos prévios que mostraram resultados funcionais adequados e baixos índices de complicação.

Descritores:
Pálpebras/cirurgia; Blefaroptose/cirurgia; Blefaroplastia/métodos Politetrafluoretileno/utilização; Sutura; Período pós-operatório

INTRODUCTION

Blepharoptosis is a condition in which the upper eyelid margin is positioned at a lower level than normal in primary gaze(11 Waqar S, McMurray C, Madge SN. Transcutaneous blepharoptosis surgery - advancement of levator aponeurosis. Open Ophthalmol J. 2010;4(1):76-80.). The condition can be congenital or acquired and is generally considered congenital if diagnosed during the first year of life. In pediatric patients, blepharoptosis can affect vision and can lead to amblyopia and loss of binocularity(22 Finsterer J. Ptosis: causes, presentation, and management. Aesthetic Plast Surg. 2003;27(3):193-204. Review.). Blepharoptosis repair is a challenging problem for oculoplastic surgeons. The choice of surgical procedure depends on the amount of ptosis and levator muscle function. The frontalis suspension (FS) technique is the treatment of choice in severe ptosis with poor levator muscle function (£4 mm)(33 Allen RC, Saylor MA, Nerad JA. The current state of ptosis repair: a comparison of internal and external approaches. Curr Opin Ophthalmol. [Research Support, Non-U.S. Gov't Review]. 2011; 22(5):394-9.). Various configurations and materials have been described to connect a sling from the upper eyelid to the frontalis muscle, which can be performed using a closed incision or an open incision technique(44 Weaver DT. Current management of childhood ptosis. Curr Opin Ophthalmol. 2018;29(5):395-400.Review.).

Autogenous muscle fascia has been widely described as the material of choice in FS surgery; however, this material has been replaced gradually by allogenic material, such as Mersilene, silicone, and polytetrafluoroethylene (PTFE)(55 Lee MJ, Oh JY, Choung HK, Kim NJ, Sung MS, Khwarg SI. Frontalis sling operation using silicone rod compared with preserved fascia lata for congenital ptosis a three-year follow-up study. Ophthalmology. 2009;116(1):123-9.,66 Pacella E, Mipatrini D, Pacella F, Amorelli G, Bottone A, Smaldone G, et al. Suspensory materials for surgery of blepharoptosis: A systematic review of observational studies. PLoS One. 2016;11(9):e0160827. Review.).

The aim of this study was to review outcomes from our 15 years of experience with FS surgery using PTFE to correct blepharoptosis.

METHODS

We conducted a retrospective, consecutive, nonrando mized audit of the clinical charts of 57 patients with blepharoptosis who underwent FS with PTFE (model CV3, 6.0-Gore-Tex®; W.L. Gore & Associates Inc, Flagstaff, AZ, USA) over a 15-year period (2003-2018) at our ophthalmic outpatient hospital-based clinic in Santo Andre SP, Brazil. All FS procedures were performed using a closed incision and single pentagon technique, as described by Fox(77 Fox SA. Congenital ptosis: II. Frontalis sling. J Pediatr Ophthalmol. 1966;3(2):25-8.). The procedures were performed by various sur geons from our teaching hospital. Charts with incomplete examination records and a follow-up of <3 months were excluded. An institutional review board ethics committee approved the study.

We recorded the patients’ epidemiological data, inclu ding age, sex, ptosis etiology, surgical outcome, compli cations, and follow-up time. Surgical outcomes were classified as satisfactory or unsatisfactory. Outcomes with a margin reflex distance (MRD) >3 mm, symmetry (<1 mm MRD difference between eyelids), and no com plications were considered satisfactory. We consi dered as unsatisfactory outcomes those with remaining asymmetry, hypocorrection, and complications, which included abscess formation, infection, suture extrusion, and granuloma.

RESULTS

A total of 76 eyelids from 52 patients submitted to FS surgery met the inclusion criteria; 5 patients were excluded according to our exclusion criteria. Twenty-four patients underwent a bilateral procedure. Table 1 shows the epidemiological data. The mean patient age was 17.6 ± 15.6 years (median, 8.0 years; range, 1-55 years), and the mean postoperative follow-up time was 16.8 ± 18.5 months (range, 3-95 months).

Table 1
Epidemiological distribution

A total of 59 (77.6%) eyelids had adequate positioning and no complications and were considered as having a satisfactory outcome. Seventeen (22.4%) surgeries were considered as having an unsatisfactory outcome (Table 2): 8 (10.5%) cases of asymmetry or undercorrection, 3 (3.9%) granulomas, 3 (3.9%) suture extrusions, 2 (2.6%) abscesses, and 1 (1.3%) case of cellulitis. In 9 (11.8%) cases, reoperation was required due to abscess (2 eyelids), granuloma (1 eyelid), suture extrusion (3 eyelids), or remaining asymmetry (3 eyelids). The remaining 8 patients did not undergo a second surgical procedure.

Table 2
Unsatisfactory postoperative outcomes

Among the listed complications, 1 case of cellulitis, 1 of granuloma, and 2 of abscesses occurred within the first week of the operation; 2 cases of granuloma and 1 case of suture extrusion occurred within 3 months of the operation; and 1 suture extrusion occurred at 14 months and another occurred at 34 months. Among the cases with a follow-up ³1 year (38 surgeries with a mean follow-up time of 27.9 months, ranging from 12 to 95 months), there were 2 (5.2%) late-onset suture extrusions that required reoperation. The remaining 36 (94.8%) eyelids maintained their initial characteristics, with no other late-onset complication or significant change in eyelid positioning or symmetry.

DISCUSSION

Blepharoptosis is a common condition characterized by a low-lying upper eyelid (<2 mm above the middle of the pupil or >2 mm inferior to the upper limbus) in primary gaze. Most cases of blepharoptosis are congenital and unilateral(88 Lucci LM, Portelinha W, Sant'Anna AE. Ptose palpebral: estudo de 390 casos. Arq Bras Oftalmol. 1997;60(5):455-7.,99 Liu HP, Shao Y, Li B, Yu X, Zhang D. Frontalis muscle transfer technique for correction of severe congenital blepharoptosis in Chinese patients: an analysis of surgical outcomes related to frontalis muscle function. J Plast Reconstr Aesthet Surg. 2015;68(12):1667-74.), with the congenital form occurring predominantly due to defective development of the levator muscle (myogenic ptosis), whose fibers present adipose and fibrous tissue, disrupting the proper functioning of the muscle (levator muscle function £4 mm). Ptosis can also have neurogenic, mechanical, and aponeurotic causes(44 Weaver DT. Current management of childhood ptosis. Curr Opin Ophthalmol. 2018;29(5):395-400.Review.,99 Liu HP, Shao Y, Li B, Yu X, Zhang D. Frontalis muscle transfer technique for correction of severe congenital blepharoptosis in Chinese patients: an analysis of surgical outcomes related to frontalis muscle function. J Plast Reconstr Aesthet Surg. 2015;68(12):1667-74.). Although other studies have shown an equal frequency between sexes(22 Finsterer J. Ptosis: causes, presentation, and management. Aesthetic Plast Surg. 2003;27(3):193-204. Review.), our study showed a significant predominance in the males (73%); however, our sample was smaller than those of other studies.

Timely surgical correction of blepharoptosis can prevent irreversible vision loss and provide cosmetic correction(1010 Hornblass A, Kass LG, Ziffer AJ. Amblyopia in congenital ptosis. Ophthalmic Surg. 1995;26(4):334-7.

11 Merriam WW, Ellis FD, Helveston EM. Congenital blepharoptosis, anisometropia, and amblyopia. Am J Ophthalmol. 1980;89(3):401-7.
-1212 Mehta A, Garg P, Naik M, Kumari A. Congenital ptosis repair with a frontalis silicon sling: comparison between Fox's single pentagon technique and a modified Crawford double triangle technique [Comparative Study Randomized Controlled Trial]. J AAPOS. 2017; 21(5):365-9.). The choice of surgical technique relies on the etiology, extent of ptosis, and levator function. In cases of poor levator muscle function, the standard techniques use the action of the frontalis muscle to raise the eyelids. FS is a minimally invasive technique that connects the frontalis muscle to the eyelid by tissue (muscle fascia) or allogenic material(22 Finsterer J. Ptosis: causes, presentation, and management. Aesthetic Plast Surg. 2003;27(3):193-204. Review.) and is typically the technique of choice(33 Allen RC, Saylor MA, Nerad JA. The current state of ptosis repair: a comparison of internal and external approaches. Curr Opin Ophthalmol. [Research Support, Non-U.S. Gov't Review]. 2011; 22(5):394-9.,66 Pacella E, Mipatrini D, Pacella F, Amorelli G, Bottone A, Smaldone G, et al. Suspensory materials for surgery of blepharoptosis: A systematic review of observational studies. PLoS One. 2016;11(9):e0160827. Review.). Various techniques can be employed to pass the sling from the upper eyelid to the frontalis muscle, including single triangle, single rhomboid (Friedenwald-Guyton), double rhomboid (Iliff), single pentagon (Fox), double triangle (Crawford), and double pentagon(44 Weaver DT. Current management of childhood ptosis. Curr Opin Ophthalmol. 2018;29(5):395-400.Review.). The frontalis muscle can likewise be transposed directly to the eyelid, using the frontalis transfer technique(99 Liu HP, Shao Y, Li B, Yu X, Zhang D. Frontalis muscle transfer technique for correction of severe congenital blepharoptosis in Chinese patients: an analysis of surgical outcomes related to frontalis muscle function. J Plast Reconstr Aesthet Surg. 2015;68(12):1667-74.).

Autologous muscle fascia has been widely employed; however, acquiring the fascia leads to increased surgical times, scar formation in a second surgical site, cicatricial contracture on the upper eyelid, and can hinder possible reoperations. Therefore, allogenic material has been employed increasingly in FS(55 Lee MJ, Oh JY, Choung HK, Kim NJ, Sung MS, Khwarg SI. Frontalis sling operation using silicone rod compared with preserved fascia lata for congenital ptosis a three-year follow-up study. Ophthalmology. 2009;116(1):123-9.,1212 Mehta A, Garg P, Naik M, Kumari A. Congenital ptosis repair with a frontalis silicon sling: comparison between Fox's single pentagon technique and a modified Crawford double triangle technique [Comparative Study Randomized Controlled Trial]. J AAPOS. 2017; 21(5):365-9.). The use of PTFE for correcting blepharoptosis has been reported over the last 30 years, showing good results with low rates of complication and patient dissatisfaction(1313 Silvério J SD, Lucci LM, Rehder JR. Suspensão ao músculo frontal com politetrafluoretileno para o tratamento de blefaroptose. Arq Bras Oftalmol. 2009;72(1):5.,1414 Anderson RL. Predictable ptosis procedures: do not go to the dark side. Ophthal Plast Reconstr Surg. 2012;28(4):239-41.). Other synthetic materials have been employed also, such as Mersilene and silicone rods(55 Lee MJ, Oh JY, Choung HK, Kim NJ, Sung MS, Khwarg SI. Frontalis sling operation using silicone rod compared with preserved fascia lata for congenital ptosis a three-year follow-up study. Ophthalmology. 2009;116(1):123-9.,66 Pacella E, Mipatrini D, Pacella F, Amorelli G, Bottone A, Smaldone G, et al. Suspensory materials for surgery of blepharoptosis: A systematic review of observational studies. PLoS One. 2016;11(9):e0160827. Review.). A systematic review has shown that PTFE had the best outcome among the investigated materials(66 Pacella E, Mipatrini D, Pacella F, Amorelli G, Bottone A, Smaldone G, et al. Suspensory materials for surgery of blepharoptosis: A systematic review of observational studies. PLoS One. 2016;11(9):e0160827. Review.).

Previous studies(22 Finsterer J. Ptosis: causes, presentation, and management. Aesthetic Plast Surg. 2003;27(3):193-204. Review.,66 Pacella E, Mipatrini D, Pacella F, Amorelli G, Bottone A, Smaldone G, et al. Suspensory materials for surgery of blepharoptosis: A systematic review of observational studies. PLoS One. 2016;11(9):e0160827. Review.,1313 Silvério J SD, Lucci LM, Rehder JR. Suspensão ao músculo frontal com politetrafluoretileno para o tratamento de blefaroptose. Arq Bras Oftalmol. 2009;72(1):5.) have shown variable reoperation rates (ranging from 1% to 13%), which correspond to our results (11.8%). We found an infection rate (3.9%) similar to that of previous studies (ranging from 1.7% to 4.3%), and the number of cases in which reoperation was not performed (88.2%) was also similar to frontalis transfer rates (ranging from 81.1% to 87.9%)(99 Liu HP, Shao Y, Li B, Yu X, Zhang D. Frontalis muscle transfer technique for correction of severe congenital blepharoptosis in Chinese patients: an analysis of surgical outcomes related to frontalis muscle function. J Plast Reconstr Aesthet Surg. 2015;68(12):1667-74.,1515 Kim WJ, Park DH, Han DG. Ten years of results of modified frontalis muscle transfer for the correction of blepharoptosis. Arch Plast Surg. 2016 Mar;43(2):172-80.). The most common complication is undercorrection (ranging from 10% to 15%), although numerous other factors should be assessed, such as eyelid function, corneal pro tection, diplopia, scarring, and eyelid contour(22 Finsterer J. Ptosis: causes, presentation, and management. Aesthetic Plast Surg. 2003;27(3):193-204. Review.).

Our study showed satisfactory results (Figure 1), with low overall complication rates. We found that using PTFE was predictable and provided good functional results, with adequate symmetry, eyelid positioning, and contour, along with lasting results in the long-term follow-up. Our study’s findings further support previous studies(22 Finsterer J. Ptosis: causes, presentation, and management. Aesthetic Plast Surg. 2003;27(3):193-204. Review.,66 Pacella E, Mipatrini D, Pacella F, Amorelli G, Bottone A, Smaldone G, et al. Suspensory materials for surgery of blepharoptosis: A systematic review of observational studies. PLoS One. 2016;11(9):e0160827. Review.,1313 Silvério J SD, Lucci LM, Rehder JR. Suspensão ao músculo frontal com politetrafluoretileno para o tratamento de blefaroptose. Arq Bras Oftalmol. 2009;72(1):5.,1414 Anderson RL. Predictable ptosis procedures: do not go to the dark side. Ophthal Plast Reconstr Surg. 2012;28(4):239-41.) that consider PTFE an effective and safe material for FS procedures.

Figure 1
A) Patient with bilateral ptosis B) Late postoperative outcome.

  • Funding: No specific financial support was available for this study.
  • Approved by the following research ethics committee: Faculdade de Medicina do ABC (# 2.830.192).

REFERENCES

  • 1
    Waqar S, McMurray C, Madge SN. Transcutaneous blepharoptosis surgery - advancement of levator aponeurosis. Open Ophthalmol J. 2010;4(1):76-80.
  • 2
    Finsterer J. Ptosis: causes, presentation, and management. Aesthetic Plast Surg. 2003;27(3):193-204. Review.
  • 3
    Allen RC, Saylor MA, Nerad JA. The current state of ptosis repair: a comparison of internal and external approaches. Curr Opin Ophthalmol. [Research Support, Non-U.S. Gov't Review]. 2011; 22(5):394-9.
  • 4
    Weaver DT. Current management of childhood ptosis. Curr Opin Ophthalmol. 2018;29(5):395-400.Review.
  • 5
    Lee MJ, Oh JY, Choung HK, Kim NJ, Sung MS, Khwarg SI. Frontalis sling operation using silicone rod compared with preserved fascia lata for congenital ptosis a three-year follow-up study. Ophthalmology. 2009;116(1):123-9.
  • 6
    Pacella E, Mipatrini D, Pacella F, Amorelli G, Bottone A, Smaldone G, et al. Suspensory materials for surgery of blepharoptosis: A systematic review of observational studies. PLoS One. 2016;11(9):e0160827. Review.
  • 7
    Fox SA. Congenital ptosis: II. Frontalis sling. J Pediatr Ophthalmol. 1966;3(2):25-8.
  • 8
    Lucci LM, Portelinha W, Sant'Anna AE. Ptose palpebral: estudo de 390 casos. Arq Bras Oftalmol. 1997;60(5):455-7.
  • 9
    Liu HP, Shao Y, Li B, Yu X, Zhang D. Frontalis muscle transfer technique for correction of severe congenital blepharoptosis in Chinese patients: an analysis of surgical outcomes related to frontalis muscle function. J Plast Reconstr Aesthet Surg. 2015;68(12):1667-74.
  • 10
    Hornblass A, Kass LG, Ziffer AJ. Amblyopia in congenital ptosis. Ophthalmic Surg. 1995;26(4):334-7.
  • 11
    Merriam WW, Ellis FD, Helveston EM. Congenital blepharoptosis, anisometropia, and amblyopia. Am J Ophthalmol. 1980;89(3):401-7.
  • 12
    Mehta A, Garg P, Naik M, Kumari A. Congenital ptosis repair with a frontalis silicon sling: comparison between Fox's single pentagon technique and a modified Crawford double triangle technique [Comparative Study Randomized Controlled Trial]. J AAPOS. 2017; 21(5):365-9.
  • 13
    Silvério J SD, Lucci LM, Rehder JR. Suspensão ao músculo frontal com politetrafluoretileno para o tratamento de blefaroptose. Arq Bras Oftalmol. 2009;72(1):5.
  • 14
    Anderson RL. Predictable ptosis procedures: do not go to the dark side. Ophthal Plast Reconstr Surg. 2012;28(4):239-41.
  • 15
    Kim WJ, Park DH, Han DG. Ten years of results of modified frontalis muscle transfer for the correction of blepharoptosis. Arch Plast Surg. 2016 Mar;43(2):172-80.

Publication Dates

  • Publication in this collection
    12 Sept 2019
  • Date of issue
    Jan-Feb 2020

History

  • Received
    28 Nov 2018
  • Accepted
    07 Mar 2019
Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil
E-mail: abo@cbo.com.br