Acessibilidade / Reportar erro

Newborns at high risk for brain injury: the role of the amplitude-integrated electroencephalography

Abstract

Objective:

Amplitude-integrated electroencephalography (aEEG) is a simplified bedside neurophysiology tool that has been implemented in the neonatal intensive care unit and studied in an extensive range of clinical applications in the past decade. This critical review aimed to evaluate a variety of clinical applications of aEEG monitoring in diagnosis, clinical management, and prognosis assessment in critically ill neonates.

Sources:

The databases of Pubmed, SciELO, Lilacs, and Cochrane, books, and other online resources were consulted, as well as sources of professional experiences.

Summary of findings:

The clinical use of aEEG to access real-time brain function, background activity, and utility in seizures detection has been described. A critical review was realized considering the authors’ professional experience. Newborns with hypoxic-ischemic encephalopathy and seizures screening represent the most common studied population. However, several studies have shown interesting applications on preterm infants, newborns with congenital heart disease, and other clinical situations of high risk of injury to the developing brain.

Conclusion:

The aEEG has shown to be a useful non-invasive bedside monitor that aids in evaluating brain function, background activity, and cyclicity. aEEG findings have also demonstrated good prognostic value in a group of critically ill neonates. The aEEG seizure diagnosis capability has limitations, which have been already well established. The use of neonatal brain monitoring such as aEEG was shown to give valuable information in several high-risk clinical situations.

KEYWORDS
Newborns; Brain injuries; Neonatal intensive care units; Brain monitoring; Amplitude-integrated electroencephalography; aEEG

Introduction

Despite recent advances in perinatal care, the incidence of impaired outcomes in neonates at high risk for brain injury is still significant and represents a challenge in neonatal care. Precise evaluation and early diagnosis of brain injury play an important role in preventing neurological impairment. In the last several years, brain monitoring devices have been steadily gaining ground in neonatal intensive care units (NICU).11 Alderliesten T, Dix L, Baerts W, Caicedo A, van Huffel S, Naulaers G, et al. Reference values of regional cerebral oxygen saturation during the first 3 days of life in preterm neonates. Pediatr Res. 2016;79:55–64.

Brain damage and the majority of electroencephalographic seizures occur in high-risk groups such as infants with hypoxic-ischemic encephalopathy, extreme prematurity, cardiac surgery, stroke, extracorporeal membrane oxygenation (ECMO), or meningitis. Still, they can also occur in other neurologic and systemic conditions.22 Triulzi F, Parazzini C, Righini A. Patterns of damage in the mature neonatal brain. Pediatr Radiol. 2006;36:608–20., 33 Ferriero DM. Neonatal brain injury. N Engl J Med. 2004;351: 1985–95., 44 Miller SP, Ramaswamy V, Michelson D, Barkovich AJ, Holshouser B, Wycliffe N, et al. Patterns of brain injury in term neonatal encephalopathy. J Pediatr. 2005;146:453–60., 55 Miller SP, Weiss J, Barnwell A, Ferriero DM, Latal-Hajnal B, Ferrer-Rogers A, et al. Seizure-associated brain injury in term newborns with perinatal asphyxia. Neurology. 2002;58:542–8., 66 Okereafor A, Allsop J, Counsell SJ, Fitzpatrick J, Azzopardi D, Rutherford MA, Cowan FM. Patterns of brain injury in neonates exposed to perinatal sentinel events. Pediatrics. 2008;121: 906–14., 77 Volpe JJ. Brain injury in premature infants: a complex amalgam of destructive and developmental disturbances. Lancet Neurol. 2009;8:110–24., 88 Volpe JJ. The encephalopathy of prematurity-brain injury and impaired brain development inextricably intertwined. Semin Pediatr Neurol. 2009;16:167–78., 99 Dimitropoulos A, McQuillen PS, Sethi V, Moosa A, Chau V, Xu D, et al. Brain injury and development in newborns with critical congenital heart disease. Neurology. 2013;81:241–8., 1010 Miller SP, McQuillen PS, Hamrick S, Xu D, Glidden DV, Charlton N, et al. Abnormal brain development in newborns with congenital heart disease. N Engl J Med. 2007;357:1928–38.

Amplitude-integrated electroencephalography (aEEG) represents a non-invasive, bedside, and simplified method of continuous brain monitoring, mainly accessed by the neonatologist, which has been increasingly used in the NICU in order to access brain function. In this method, a minimum of three electrodes are placed on the scalp (more electrodes may be used to record a multichannel aEEG). Similar to EEG, differences in electrical potentials are recorded, and changes in electrical activity are displayed over time. Then, the electrical activity is time-compressed, rectified, smoothed, and displayed semilogarithmically in a 6cm/h chart after being filtered for frequency. Newer equipment can associate aEEG with raw EEG traces and video imaging, allowing better identification of seizures and artifacts in the NICU.1111 Murray DM, O'Connor CM, Ryan CA, Korotchikova I, Boylan GB. Early EEG grade and outcome at 5 years after mild neonatal hypoxic ischemic encephalopathy. Pediatrics. 2016;138: e20160659., 1212 Variane GF, Magalhães M, Gasperine R, Alves HC, Scoppetta TL, Figueredo RJ, et al. Early amplitude-integrated electroencephalography for monitoring neonates at high risk for brain injury. J Pediatr (Rio J). 2017;93:460–6., 1313 Shellhaas RA, Clancy RR. Characterization of neonatal seizures by conventional EEG and single-channel EEG. Clin Neurophysiol. 2007;118:2156–61., 1414 Patrizi S, Holmes GL, Orzalesi M, Allemand F. Neonatal seizures: characteristics of EEG ictal activity in preterm and fullterm infants. Brain Dev. 2003;25:427–37.

Previous findings have shown that aEEG, as well as the conventional EEG, is a valuable tool to access background activity, cyclicity, which can be represented by periodical changes in the pattern of aEEG neonatal recording, often referred to as sleep-wake cycling (SWC), and to detect seizures in critically ill neonates as a continuous bedside monitoring. 1111 Murray DM, O'Connor CM, Ryan CA, Korotchikova I, Boylan GB. Early EEG grade and outcome at 5 years after mild neonatal hypoxic ischemic encephalopathy. Pediatrics. 2016;138: e20160659., 1212 Variane GF, Magalhães M, Gasperine R, Alves HC, Scoppetta TL, Figueredo RJ, et al. Early amplitude-integrated electroencephalography for monitoring neonates at high risk for brain injury. J Pediatr (Rio J). 2017;93:460–6., 1313 Shellhaas RA, Clancy RR. Characterization of neonatal seizures by conventional EEG and single-channel EEG. Clin Neurophysiol. 2007;118:2156–61., 1414 Patrizi S, Holmes GL, Orzalesi M, Allemand F. Neonatal seizures: characteristics of EEG ictal activity in preterm and fullterm infants. Brain Dev. 2003;25:427–37., 1515 Kidokoro H, Inder T, Okumura A, Watanabe K. What does cyclicity on amplitude-integrated EEG mean? J Perinatol. 2012;32:565–9., 1616 Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7.

This review aimed to discuss a variety of clinical applications of aEEG for monitoring critically ill neonates.

Revision

The databases of Pubmed, SciELO, Lilacs and Cochrane, books, and other online resources were consulted, as well as sources of professional experiences, in order to carry out this critical review about the use of aEEG in newborns at high-risk for brain injury. The central-temporal areas are the source of most newborn seizures, and the features of EEG ictal activity differ between preterm and full-term babies.1616 Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7., 1717 Shah DK, Mackay MT, Lavery S, Watson S, Harvey AS, Zempel J, et al. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics. 2008;121:1146–54.

Although traditional EEG is the gold standard for seizure diagnosis, and short or low voltage seizures may be missed in aEEG depending on the examiner, the aEEG has the advantage of being more straightforward and quicker to apply. Also, more extended periods can be monitored, and thus, there are more chances of not missing seizures as in a punctual cEEG for a few hours. It should also be remembered that aEEG can be applied almost immediately on demand, and aEEG has become an interesting option to be used as a bedside tool for monitoring neonates. Several studies and reviews have accessed the accuracy of aEEG for seizure detection. Using two-channel aEEG associated with raw EEG interpretation has improved accuracy.1616 Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7., 1717 Shah DK, Mackay MT, Lavery S, Watson S, Harvey AS, Zempel J, et al. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics. 2008;121:1146–54., 1818 Toet MC, van der Meij W, de Vries LS, Uiterwaal CS, van Huffelen KC. Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates. Pediatrics. 2002;109:772–9., 1919 Lawrence R, Mathur A, Nguyen The Tich S, Zempel J, Inder T. A pilot study of continuous limited-channel aEEG in term infants with encephalopathy. J Pediatr. 2009;154:835–41. e1., 2020 Frenkel N, Friger M, Meledin I, Berger I, Marks K, Bassan H, et al. Neonatal seizure recognition-comparative study of continuousamplitude integrated EEG versus short conventional EEG recordings. Clin Neurophysiol. 2011;122:1091–7., 2121 Glass HC, Wusthoff CJ, Shellhaas RA. Amplitude-integrated electro-encephalography: the child neurologist's perspective. J Child Neurol. 2013;28:1342–50., 2222 Mastrangelo M, Fiocchi I, Fontana P, Gorgone G, Lista G, Belcastro V. Acute neonatal encephalopathy and seizures recurrence: a combined aEEG/EEG study. Seizure. 2013;22:703–7., 2323 Rakshasbhuvankar A, Paul S, Nagarajan L, Ghosh S, Rao S. Amplitude-integrated EEG for detection of neonatal seizures: a systematic review. Seizure. 2015;33:90–8., 2424 Rennie JM, Chorley G, Boylan GB, Pressler R, Nguyen Y, Hooper R. Non-expert use of the cerebral function monitor for neonatal seizure detection. Arch Dis Child Fetal Neonatal Ed. 2004;89: F37–40. Seizure activity is characterized in aEEG by a sudden change in background activity as an abrupt rise in minimum and maximum aEEG amplitudes correlated with an evolving, stereotypical, and rhythmic wave pattern, repeating form such as spikes or sharp waves, often with high amplitude in raw EEG, with a total duration of at least ten seconds2525 Clancy RR, Legido A, Lewis D. Occult neonatal seizures. Epilepsia. 1988;29:256–61. (Figure 1). The central-temporal areas are the source of most newborn seizures, and the features of EEG ictal activity differ between preterm and full-term babies.1616 Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7., 1717 Shah DK, Mackay MT, Lavery S, Watson S, Harvey AS, Zempel J, et al. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics. 2008;121:1146–54.

Figure 1
An example of how seizures appear on aEEG and raw EEG. [Authors' personal file].

Shellhaas et al.1616 Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7. evaluated 125 aEEG single-channel C3-C4 readings from patients with gestational ages ranging from 36 to 44 weeks. In this study, 78% of all neonatal seizures appeared in the single-channel aEEG. Compared to traditional electroencephalography, however, aEEG seizures were shorter and had a lower amplitude.1616 Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7. Shah et al.1717 Shah DK, Mackay MT, Lavery S, Watson S, Harvey AS, Zempel J, et al. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics. 2008;121:1146–54. monitored 21 term newborns referred to a tertiary hospital with clinical seizures. Thirty-one of forty-one non-status epilepticus episodes were recognized properly (sensitivity, 76%; specificity, 78%; positive predictive value, 78%; negative predictive value, 78%). When amplitude-integrated electroencephalography was accessed (one or two-channel) without the use of raw EEG readings, a lower sensitivity (27-56%) was found.1717 Shah DK, Mackay MT, Lavery S, Watson S, Harvey AS, Zempel J, et al. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics. 2008;121:1146–54.

Frenkel et al.2020 Frenkel N, Friger M, Meledin I, Berger I, Marks K, Bassan H, et al. Neonatal seizure recognition-comparative study of continuousamplitude integrated EEG versus short conventional EEG recordings. Clin Neurophysiol. 2011;122:1091–7. evaluated 38 high-risk babies for seizures and compared the sensitivity and specificity of seizures detection across users with varying levels of aEEG competence. When students assessed the raw EEG trace for seizure detection, the sensitivity and specificity were 84% and 66%, respectively, and 71% and 97% for neonatologists. In the hands of expert users, the technique offers excellent sensitivity and specificity, according to the author.2020 Frenkel N, Friger M, Meledin I, Berger I, Marks K, Bassan H, et al. Neonatal seizure recognition-comparative study of continuousamplitude integrated EEG versus short conventional EEG recordings. Clin Neurophysiol. 2011;122:1091–7.

A systematic review by Rakshasbhuvankar et al.2323 Rakshasbhuvankar A, Paul S, Nagarajan L, Ghosh S, Rao S. Amplitude-integrated EEG for detection of neonatal seizures: a systematic review. Seizure. 2015;33:90–8. included ten studies (patient sample of 433) and found a median sensitivity of 76% and specificity of 85% for seizure detection when aEEG was evaluated together with raw EEG tracings. When aEEG data was evaluated by experienced aEEG readers, the accuracy was higher.1616 Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7., 2323 Rakshasbhuvankar A, Paul S, Nagarajan L, Ghosh S, Rao S. Amplitude-integrated EEG for detection of neonatal seizures: a systematic review. Seizure. 2015;33:90–8., 2424 Rennie JM, Chorley G, Boylan GB, Pressler R, Nguyen Y, Hooper R. Non-expert use of the cerebral function monitor for neonatal seizure detection. Arch Dis Child Fetal Neonatal Ed. 2004;89: F37–40.

The diagnosis and proper treatment of seizures are extremely important in the neonatal period since most episodes occur without associated clinical manifestations. Previous studies demonstrate that epileptic seizures are directly associated with brain damage. At the same time, if the authors use anticonvulsants inappropriately and inadvertently, the authors will also cause brain damage from drug-triggered apoptosis. With continuous bedside monitoring, the authors use fewer anticonvulsants and more assertively.

Hypoxic ischemic encephalopathy (HIE)

In term newborns, HIE is a significant cause of early death and persistent severe impairment.2626 García-Alix A, Martínez-Biarge M, Diez J, Gayá F, Quero J. Incidencia y prevalencia de la encefalopatía hipoxico-isquémica en la primera década del siglo XXI. Ann Pediatr (Barc). 2009;71:319–26. The degree of the brain injury and neurological outcome should be assessed to guide management, therapy selection, prognosis evaluation, and parent counseling.

HIE is the most prevalent cause of neonatal seizures.2727 Scher MS, Aso K, Beggarly ME, Hamid MY, Steppe DA, Painter MJ. Electrographic seizures in preterm and full-term neonates: clinical correlates, associated brain lesions, and risk for neurologic sequelae. Pediatrics. 1993;91:128–34. Since most neonatal seizures have no clinical signs, continuous brain monitoring has an essential role in this population. Beside seizure detection, aEEG has been used for prognosis assessment and as entry criteria for cooling in some clinical trials.

Prognosis assessment

Before the cooling era, abnormal aEEG background patterns during the first 3-6 postnatal hours were significantly predictive of unfavorable outcomes.2828 al Naqeeb N, Edwards AD, Cowan FM, Azzopardi D. Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography. Pediatrics. 1999;103:1263–71., 2929 Toet MC, Hellström-Westas L, Groenendaal F, Eken P, de Vries LS. Amplitude integrated EEG 3 and 6 h after birth in full term neonates with hypoxic-ischaemic encephalopathy. Arch Dis Child Fetal Neonatal Ed. 1999;81:F19–23., 3030 Hellström-Westas L, Rosén I, Svenningsen NW. Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants. Arch Dis Child Fetal Neonatal Ed. 1995;72:F34–8. Hellstrom-Westas et al.3030 Hellström-Westas L, Rosén I, Svenningsen NW. Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants. Arch Dis Child Fetal Neonatal Ed. 1995;72:F34–8. described that early aEEG background activity correctly predicted neurological outcomes in 91.5% of infants in a cohort of 47 neonates with HIE.3030 Hellström-Westas L, Rosén I, Svenningsen NW. Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants. Arch Dis Child Fetal Neonatal Ed. 1995;72:F34–8.

In 2007, Spitzmiller et al.3131 Spitzmiller RE, Phillips T, Meinzen-Derr J, Hoath SB. Amplitudeintegrated EEG is useful in predicting neurodevelopmental outcome in full-term infants with hypoxic-ischemic encephalopathy: a meta-analysis. J Child Neurol. 2007;22:1069–78. carried out a meta-analysis to assess the evidence for utilizing aEEG as a quantitative predictor of neurodevelopmental outcome in full-term infants with HIE. They found that aEEG had an overall sensitivity of 91% (95% and confidence interval: 87–95) and a negative probability ratio of 0.09 (95% confidence interval: .06-.15) for properly predicting a bad outcome, which shows how aEEG can help predict long-term neurodevelopmental outcomes for high-risk babies.3131 Spitzmiller RE, Phillips T, Meinzen-Derr J, Hoath SB. Amplitudeintegrated EEG is useful in predicting neurodevelopmental outcome in full-term infants with hypoxic-ischemic encephalopathy: a meta-analysis. J Child Neurol. 2007;22:1069–78.

The prognostic value of aEEG at 6 h of life had changed when cooling was implemented. The authors have described time to recovery to normal background pattern as a very important predictor of outcome after 48 h of life, and an abnormal aEEG tracing is linked to subsequent abnormal neurodevelopmental outcomes.3232 Thoresen M, Hellstrom-Westas L, Liu X, de Vries LS. Effect of hypothermia on amplitude-integrated electroencephalogram in infants with asphyxia. Pediatrics. 2010;126:e131–9., 3333 Csekő AJ, Bangó M, Lakatos P, Kárdási J, Pusztai L, Szabó M. Accuracy of amplitude-integrated electroencephalography in the prediction of neurodevelopmental outcome in asphyxiated infants receiving hypothermia treatment. Acta Paediatr. 2013;102:707–11. Thoresen et al.3232 Thoresen M, Hellstrom-Westas L, Liu X, de Vries LS. Effect of hypothermia on amplitude-integrated electroencephalogram in infants with asphyxia. Pediatrics. 2010;126:e131–9. studied a cohort of 74 infants with HIE. They discovered that an abnormal aEEG pattern at the age of 3 to 6 h had a positive predictive value of 84% for normothermia and 59% for hypothermia. The recovery time to normal background pattern was the best predictor of poor outcome (96.2% in hypothermia, 90.9% in normothermia).3232 Thoresen M, Hellstrom-Westas L, Liu X, de Vries LS. Effect of hypothermia on amplitude-integrated electroencephalogram in infants with asphyxia. Pediatrics. 2010;126:e131–9.

Some investigations studied the effect of therapeutic hypothermia (TH) may have on aEEG accuracy in predicting neurodevelopmental outcomes. Chandrasekaran et al.3434 Chandrasekaran M, Chaban B, Montaldo P, Thayyil S. Predictive value of amplitude-integrated EEG (aEEG) after rescue hypothermic neuroprotection for hypoxic ischemic encephalopathy: a meta-analysis. J Perinatol. 2017;37:684–9. also conducted a meta-analysis to examine the prognostic accuracy for predicting long-term neurodevelopmental outcomes in term newborn infants undergoing TH for moderate or severe EHI. The authors systematically evaluated the predictive value of an abnormal trace acquired at 6, 24, 48, and 72 h of age. They concluded that the aEEG background at six h of age has a good sensitivity of 96%, but poor specificity 39%, and at 48 h or later, a persistently severe abnormal aEEG background predicts a poor prognosis (positive predictive value 85% and diagnostic odds ratio 67 at 48 h). According to this study, the predictive ability of aEEG background at six hours of age during TH induction is sub-optimal. Because consistently abnormal traces at 48 h or more were linked with poor long-term outcomes, aEEG examination at 48 h of age may be beneficial as an additional bedside inquiry for clinical decision making.3434 Chandrasekaran M, Chaban B, Montaldo P, Thayyil S. Predictive value of amplitude-integrated EEG (aEEG) after rescue hypothermic neuroprotection for hypoxic ischemic encephalopathy: a meta-analysis. J Perinatol. 2017;37:684–9.

A systematic review by Del Río et al.3535 Del Río R, Ochoa C, Alarcon A, Arnáez J, Blanco D, García-Alix A. Amplitude integrated electroencephalogram as a prognostic tool in neonates with hypoxic-ischemic encephalopathy: a systematic review. PLoS One. 2016;11:e0165744. included 17 studies and found that infants not treated with hypothermia with abnormal aEEG background at six hours of life had a positive predictive value of 88.20% (95%CI 79.80 to 93%) in the prediction of death or moderate/severe disability. In this cohort, the highest dependability of an abnormal aEEG in predicting prognosis was found at 36 h of life, with a positive post-test probability of 97.90% (95% and confidence interval: 88.40 to 99.40%). Maximum predictive reliability was reached in babies treated with TH at 72 h of life, with a post-test probability of 95.70% (95%CI 84.40 to 98.50%).3535 Del Río R, Ochoa C, Alarcon A, Arnáez J, Blanco D, García-Alix A. Amplitude integrated electroencephalogram as a prognostic tool in neonates with hypoxic-ischemic encephalopathy: a systematic review. PLoS One. 2016;11:e0165744.

Entry criteria for therapeutic hypothermia

It is well established that TH significantly improves survival and reduces disability, including cerebral palsy and neurocognitive outcomes, in full-term infants with moderate to severe HIE.3636 Jacobs SE, Berg M, Hunt R, Tarnow-Mordi WO, Inder TE, Davis PG. Cooling for newborns with hypoxic ischaemic encephalopathy. Cochrane Database Syst Rev. 2013;2013:CD003311.

Due to the good prognostic value of early aEEG in infants with HIE evaluated before the cooling era,2828 al Naqeeb N, Edwards AD, Cowan FM, Azzopardi D. Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography. Pediatrics. 1999;103:1263–71., 2929 Toet MC, Hellström-Westas L, Groenendaal F, Eken P, de Vries LS. Amplitude integrated EEG 3 and 6 h after birth in full term neonates with hypoxic-ischaemic encephalopathy. Arch Dis Child Fetal Neonatal Ed. 1999;81:F19–23., 3030 Hellström-Westas L, Rosén I, Svenningsen NW. Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants. Arch Dis Child Fetal Neonatal Ed. 1995;72:F34–8. some of the main clinical trials that evaluated the efficacy of TH added an abnormal aEEG background as needed entry criteria for initiation of cooling.3737 Azzopardi DV, Strohm B, Edwards AD, Dyet L, Halliday HL, Juszczak E, et al. Moderate hypothermia to treat perinatal asphyxial encephalopathy. N Engl J Med. 2009;361:1349–58., 3838 Gluckman PD, Wyatt JS, Azzopardi D, Ballard R, Edwards AD, Ferriero DM, et al. Selective head cooling with mild systemic hypothermia after neonatal encephalopathy: multicentre randomised trial. Lancet. 2005;365:663–70. However, it is still unclear whether abnormal aEEG background should be used to identify infants for TH. The accurate identification of infants suffering from encephalopathy is crucial. Clinical studies of TH in newborns without indications of moderate or severe encephalopathy have yet to be conducted. It is also essential not to exclude patients who could benefit from neuroprotective strategies.

A recent study evaluated 47 infants who underwent TH and aimed to examine whether using aEEG severity pattern should be used as entry criteria for TH. Results suggested that an abnormal aEEG would improve the selection of infants with HIE.3939 Skranes JH, Løhaugen G, Schumacher EM, Osredkar D, Server A, Cowan FM, et al. Amplitude-integrated electroencephalography improves the identification of infants with encephalopathy for therapeutic hypothermia and predicts neurodevelopmental outcomes at 2 years of age. J Pediatr. 2017;187:34–42. The authors think it is reasonable to use aEEG in the first 6 h of life as another tool for evaluating newborns possibly eligible for treatment with TH. However, not necessarily a pathological background activity should be mandatory as entry criteria, and a normal background activity isolated should not exclude newborns from treatment with hypothermia. Future and ongoing studies need to better evaluate the use of aEEG in the first six hours of life as an entry criterion for therapeutic hypothermia for more solid conclusions.

Brain monitoring in asphyxiated newborns has been shown to be important in clinical practice at the bedside due to: assessment of brain function over time, providing support in the indication or not of TH, diagnosing neonatal seizures commonly present in this condition, and also predicting long-term neurological prognosis.

Preterm infants

The first studies of using aEEG in premature infants have been described in the 80’s by Verma et al.4040 Verma UL, Archbald F, Tejani NA, Handwerker SM. Cerebral function monitor in the neonate. I: normal patterns. Dev Med Child Neurol. 1984;26:154–61. and in the 90’s by Hellstrom-Westas et al.4141 Hellström-Westas L, Rosén I, Svenningsen NW. Cerebral function monitoring during the first week of life in extremely small low birthweight (ESLBW) infants. Neuropediatrics. 1991;22:27–32. Although the use of aEEG in term newborns is well acknowledged, research into its use in preterm infants is still ongoing.

In terms of background activity, in extremely preterm babies, the EEG background is discontinuous, with high-voltage bursts and low-voltage interburst periods. Discontinuity decreases with increasing gestational age.4242 Scoppa A, Casani A, Cocca F, Coletta C, De Luca MG, Di Manso G, et al. aEEG in preterm infants. J Matern Fetal Neonatal Med. 2012;25:139–40. A concordance between sleep states and continuity/discontinuity is not established in the smallest preemies, even though the cyclicity represents a very early phenomenon in cerebral function even before 27 weeks.1515 Kidokoro H, Inder T, Okumura A, Watanabe K. What does cyclicity on amplitude-integrated EEG mean? J Perinatol. 2012;32:565–9., 4141 Hellström-Westas L, Rosén I, Svenningsen NW. Cerebral function monitoring during the first week of life in extremely small low birthweight (ESLBW) infants. Neuropediatrics. 1991;22:27–32., 4343 Olischar M, Klebermass K, Kuhle S, Hulek M, Kohlhauser C, Rucklinger E, et al. Reference values for amplitude-integrated electroencephalographic activity in preterm infants younger than 30 weeks' gestational age. Pediatrics. 2004;113:e61–6., 4444 Burdjalov VF, Baumgart S, Spitzer AR. Cerebral function monitoring: a new scoring system for the evaluation of brain maturation in neonates. Pediatrics. 2003;112:855–61. More frequent 'bursts' are conceivable, and the raw EEG tracing may reveal periods of relatively low voltage activity interspersed with brief but rare bursts of high activity.4545 Tao JD, Mathur AM. Using amplitude-integrated EEG in neonatal intensive care. J Perinatol. 2010;30:S73–81.

Seizures are a tricky issue in preterm infants, as they are the ones who are either missed (short and of the same voltage of the background activity) or misdiagnosed due to many rhythmic events in the NICU mimicking seizures.4646 Weeke LC, van Ooijen IM, Groenendaal F, van Huffelen AC, van Haastert IC, van Stam C, et al. Rhythmic EEG patterns in extremely preterm infants: classification and association with brain injury and outcome. Clin Neurophysiol. 2017;128:2428–35. Though many authors evaluated seizures in preterm infants, not many included EEG,4747 Lloyd RO, O'Toole JM, Pavlidis E, Filan PM, Boylan GB. Electrographic seizures during the early postnatal period in preterm infants. J Pediatr. 2017;187:18–25. e2. and only four used aEEG (two are mentioned in the manuscript: Shah et al.4848 Shah DK, Zempel J, Barton T, Lukas K, Inder TE. Electrographic seizures in preterm infants during the first week of life are associated with cerebral injury. Pediatr Res. 2010;67:102–6. and Vesoulis et al.4949 Vesoulis ZA, Inder TE, Woodward LJ, Buse B, Vavasseur C, Mathur AM. Early electrographic seizures, brain injury, and neurodevelopmental risk in the very preterm infant. Pediatr Res. 2014;75:564–9.).

The incidence of described electrographic seizures in the preterm infant varies widely from 4% to 48%.4141 Hellström-Westas L, Rosén I, Svenningsen NW. Cerebral function monitoring during the first week of life in extremely small low birthweight (ESLBW) infants. Neuropediatrics. 1991;22:27–32., 4848 Shah DK, Zempel J, Barton T, Lukas K, Inder TE. Electrographic seizures in preterm infants during the first week of life are associated with cerebral injury. Pediatr Res. 2010;67:102–6., 5050 Tekgul H, Gauvreau K, Soul J, Murphy L, Robertson R, Stewart J, et al. The current etiologic profile and neurodevelopmental outcome of seizures in term newborn infants. Pediatrics. 2006;117:1270–80., 5151 Davis AS, HintzSR, Van Meurs KP, Li L, Das A, Stoll BJ, etal. Seizures in extremely low birth weight infants are associated with adverse outcome. J Pediatr. 2010;157:720–5.e1-2. Intraventricular hemorrhage (IVH), white matter injury (WMI), mortality in the neonatal period, and moderate to severe cognitive impairment on follow-up have all been linked to electrographic seizures in preterm infants.4949 Vesoulis ZA, Inder TE, Woodward LJ, Buse B, Vavasseur C, Mathur AM. Early electrographic seizures, brain injury, and neurodevelopmental risk in the very preterm infant. Pediatr Res. 2014;75:564–9.

Vesoulis et al.4949 Vesoulis ZA, Inder TE, Woodward LJ, Buse B, Vavasseur C, Mathur AM. Early electrographic seizures, brain injury, and neurodevelopmental risk in the very preterm infant. Pediatr Res. 2014;75:564–9. evaluated a cohort of 95 very preterm infants for 72 h after birth. They found an incidence of 48% of seizures, which were associated with poor early and long-term outcomes.4949 Vesoulis ZA, Inder TE, Woodward LJ, Buse B, Vavasseur C, Mathur AM. Early electrographic seizures, brain injury, and neurodevelopmental risk in the very preterm infant. Pediatr Res. 2014;75:564–9. Preterm infants with seizures have shown in studies to be more likely to die, which means that seizures may be an indicator of pathologies that could lead to death, even though seizures alone do not represent a predictor of death.5252 Meledin I, Tzur-Sebton H, Noyman I, Friger M, Hazan G, Shany E. Seizures in premature infants born at less than 28 weeks' gestation. Neonatology. 2019;115:247–55.

In the first postnatal week, continuous background activity and cyclicity have been linked to a positive neurodevelopmental result.5353 Wikström S, Pupp IH, Rosén I, Norman E, Fellman V, Ley D, et al. Early single-channel aEEG/EEG predicts outcome in very preterm infants. Acta Paediatr. 2012;101:719–26. Abnormal background activity and absence of cyclicity in the first days/weeks of life were associated with severe IVH, WMI, neonatal death,1212 Variane GF, Magalhães M, Gasperine R, Alves HC, Scoppetta TL, Figueredo RJ, et al. Early amplitude-integrated electroencephalography for monitoring neonates at high risk for brain injury. J Pediatr (Rio J). 2017;93:460–6., 5454 Soubasi V, Mitsakis K, Sarafidis K, Griva M, Nakas CT, Drossou V Early abnormal amplitude-integrated electroencephalography (aEEG) is associated with adverse short-term outcome in premature infants. Eur J Paediatr Neurol. 2012;16:625–30. and neurological impairment at two years of age.5353 Wikström S, Pupp IH, Rosén I, Norman E, Fellman V, Ley D, et al. Early single-channel aEEG/EEG predicts outcome in very preterm infants. Acta Paediatr. 2012;101:719–26., 5555 Klebermass K, Olischar M, Waldhoer T, Fuiko R, Pollak A, WeningerM. Amplitude-integrated EEG pattern predicts further outcome in preterm infants. Pediatr Res. 2011;70:102–8.

Soubasi et al.5454 Soubasi V, Mitsakis K, Sarafidis K, Griva M, Nakas CT, Drossou V Early abnormal amplitude-integrated electroencephalography (aEEG) is associated with adverse short-term outcome in premature infants. Eur J Paediatr Neurol. 2012;16:625–30. monitored 115 infants from 25 to 32 weeks of gestational age within 72 h of life. The presence of pathological trace (defined as burst suppression, continuous low voltage or flat) or discontinuous low voltage displayed a sensitivity of 88.9% severe brain damage in cranial ultrasonography results or death.5454 Soubasi V, Mitsakis K, Sarafidis K, Griva M, Nakas CT, Drossou V Early abnormal amplitude-integrated electroencephalography (aEEG) is associated with adverse short-term outcome in premature infants. Eur J Paediatr Neurol. 2012;16:625–30.

Klebermass et al.5555 Klebermass K, Olischar M, Waldhoer T, Fuiko R, Pollak A, WeningerM. Amplitude-integrated EEG pattern predicts further outcome in preterm infants. Pediatr Res. 2011;70:102–8. study evaluated 143 preterm infants with gestational age below 30 weeks during the first two weeks of life. aEEG was classified into a graded score according to background activity, the appearance of cyclicity, and seizure activity and correlated with the good neurological outcome at three years of age. Specificity and sensitivity were 95% and 83%, respectively in aEEG findings in the second week of life and were superior when compared with cranial ultrasound findings.5555 Klebermass K, Olischar M, Waldhoer T, Fuiko R, Pollak A, WeningerM. Amplitude-integrated EEG pattern predicts further outcome in preterm infants. Pediatr Res. 2011;70:102–8.

The use of aEEG in seizures and brain function evaluation in preterm newborns has shown to be beneficial. Electrographic seizures in the first week of life are linked to poor outcomes, according to research.4848 Shah DK, Zempel J, Barton T, Lukas K, Inder TE. Electrographic seizures in preterm infants during the first week of life are associated with cerebral injury. Pediatr Res. 2010;67:102–6. A study conducted by Wikström et al.5353 Wikström S, Pupp IH, Rosén I, Norman E, Fellman V, Ley D, et al. Early single-channel aEEG/EEG predicts outcome in very preterm infants. Acta Paediatr. 2012;101:719–26. evaluated 49 preterm infants between 22 and 30 weeks of gestational age to characterize aEEG and EEG for prediction of long-term outcome. They reported that aEEG/EEG could predict long-term outcomes with 75-80% accuracy at 24 h of life, even within those with no early indication of brain damage.5353 Wikström S, Pupp IH, Rosén I, Norman E, Fellman V, Ley D, et al. Early single-channel aEEG/EEG predicts outcome in very preterm infants. Acta Paediatr. 2012;101:719–26.

The use of early aEEG examination in preterm infants may help in providing helpful counseling information. Some clinical neonatologists consider hazardous the need to manipulate the newborn's head in the first 72 h of life to place the aEEG electrodes in very preterm infants regarding prevention of periventricular hemorrhage. The authors consider that this possible risk can be minimized with gentle care and is outweighed by the benefits highlighted above.

The use of brain monitoring in preterm infants has evolved as new scientific research has been published, but some questions still need to be elucidated, such as: is it safe to install the aEEG in the period of minimal handling? Does it alter the incidence of peri- and intraventricular hemorrhage? Will the care be better with brain monitoring, avoiding neurological damage? These are some questions that the literature must answer in the future.

Congenital heart disease

Brain injury is a common and sometimes fatal complication of severe congenital heart disease (CHD) that needs surgery during the neonatal period.5656 Wernovsky G, Shillingford AJ, Gaynor JW. Central nervous system outcomes in children with complex congenital heart disease. CurrOpin Cardiol. 2005;20:94–9. The perioperative period represents a moment of risk when the developing brain is vulnerable to acute cerebral perfusion and oxygenation changes.

Clinical and electrographic seizures in the perioperative period have been associated with neurological impairment in cohorts of infants with CHD. Several authors used aEEG for evaluating the incidence of seizures, early recovery to normal background activity, and presence of SWC after cardiac surgery with good neurological outcome in this population.5757 Gunn JK, Beca J, Hunt RW, Olischar M, Shekerdemian LS. Perioperative amplitude-integrated EEG and neurodevelopment in infants with congenital heart disease. Intensive Care Med. 2012;38:1539–47., 5858 Latal B, Wohlrab G, Brotschi B, Beck I, Knirsch W, Bernet V Postoperative amplitude-integrated electroencephalography predicts four-year neurodevelopmental outcome in children with complex congenital heart disease. J Pediatr. 2016;178: 55–60. e1.

Gunn et al.5757 Gunn JK, Beca J, Hunt RW, Olischar M, Shekerdemian LS. Perioperative amplitude-integrated EEG and neurodevelopment in infants with congenital heart disease. Intensive Care Med. 2012;38:1539–47. studied a large group of 150 newborn children who had heart surgery and were monitored with aEEG during the perioperative phase (before and during surgery, and for 72 h postoperatively). Perioperative electrical seizures were found in 30%, of whom 1/4 had any clinical correlation. Failure to return to a continuous background at aEEG by 48 h postoperatively was linked to impairment in all outcome categories, and abnormal aEEG at seven days postoperatively was strongly linked to death.5757 Gunn JK, Beca J, Hunt RW, Olischar M, Shekerdemian LS. Perioperative amplitude-integrated EEG and neurodevelopment in infants with congenital heart disease. Intensive Care Med. 2012;38:1539–47.

During the management of infants with CHD, in addition to survival, the aim is to minimize the risk of neurological sequelae; therefore, the authors recommend brain monitoring before, during, and after cardiac surgery. Using brain monitoring in these 3 phases, the authors can have an early diagnosis of seizures and electroencephalographic changes associated with brain injury, enabling assertive therapy and possibly impacting long-term neurodevelopment.

Other applications

The neonatal intensive care unit usually counts with many infants at high risk of brain injury. Beside neonates with HIE, extreme prematurity, and congenital heart diseases, other conditions pose true moments of high risk for brain injury and incidence of seizures. Metabolic disorders, inborn errors of metabolism (IEM), stroke, cerebral malformations, congenital infections, sepsis, meningitis, hemodynamic and ventilator instability, ECMO, and recovery after cardiac arrest are examples of these conditions.

Since aEEG is a useful non-invasive tool to access realtime brain function and seizure detection in the neonatal population, there are many possible situations where aEEG could be applied, and several studies have addressed this issue.5959 Olischar M, Shany E, Aygun C, Azzopardi D, Hunt RW, Toet MC, et al. Amplitude-integrated electroencephalography in newborns with inborn errors of metabolism. Neonatology. 2012;102: 203–11., 6060 Helderman JB, Welch CD, Leng X, O'Shea TM. Sepsis-associated electroencephalographic changes in extremely low gestational age neonates. Early Hum Dev. 2010;86:509–13., 6161 Toso PA, González AJ, Pérez ME, Kattan J, Fabres JG, Tapia JL, et al. Clinical utility of early amplitude integrated EEG in monitoring term newborns at risk of neurological injury. J Pediatr (Rio J). 2014;90:143–8.

Olischar et al.5959 Olischar M, Shany E, Aygun C, Azzopardi D, Hunt RW, Toet MC, et al. Amplitude-integrated electroencephalography in newborns with inborn errors of metabolism. Neonatology. 2012;102: 203–11. evaluated a cohort of 30 infants with IEM and found abnormal background activity in 70% and presence of seizures in 60% of monitored patients. Infants with metabolic energy problems, hyperammonemia, and organic/ amino acidopathies frequently had aEEG depression and seizure activity. The aEEG of individuals with peroxisomal diseases, on the other hand, did not reveal any significant background abnormalities.5959 Olischar M, Shany E, Aygun C, Azzopardi D, Hunt RW, Toet MC, et al. Amplitude-integrated electroencephalography in newborns with inborn errors of metabolism. Neonatology. 2012;102: 203–11.

Toso et al.6161 Toso PA, González AJ, Pérez ME, Kattan J, Fabres JG, Tapia JL, et al. Clinical utility of early amplitude integrated EEG in monitoring term newborns at risk of neurological injury. J Pediatr (Rio J). 2014;90:143–8. evaluated 21 infants with different causes of neonatal encephalopathy, neurologic disturbance, or severe respiratory distress syndrome and found the incidence of 38% of seizures.6161 Toso PA, González AJ, Pérez ME, Kattan J, Fabres JG, Tapia JL, et al. Clinical utility of early amplitude integrated EEG in monitoring term newborns at risk of neurological injury. J Pediatr (Rio J). 2014;90:143–8.

Helderman et al.6060 Helderman JB, Welch CD, Leng X, O'Shea TM. Sepsis-associated electroencephalographic changes in extremely low gestational age neonates. Early Hum Dev. 2010;86:509–13. examined a large group of 108 preterm children born before 28 weeks of gestation and used an electroencephalogram (EEG) every month from 28 to 36 weeks of postmenstrual age. During the first bout of sepsis in the babies, further aEEG recordings were made. At the moment of recording, burst suppression was identified in 22% of aEEG recordings from newborns without sepsis and 57% of babies with sepsis, showing that sepsis is associated with acute electroencephalographic changes.6060 Helderman JB, Welch CD, Leng X, O'Shea TM. Sepsis-associated electroencephalographic changes in extremely low gestational age neonates. Early Hum Dev. 2010;86:509–13.

Several medications such as sedation and antiepileptic drugs affect brain function and can influence aEEG background activity. This influence usually is related to depression on background activity and depends on the type and dose of the used drug. Norman et al.6262 Norman E, Wikström S, Rosén I, Fellman V, Hellström-Westas L. Premedication for intubation with morphine causes prolonged depression of electrocortical background activity in preterm infants. Pediatr Res. 2013;73:87–94. performed a randomized controlled trial using aEEG/EEG as a brain monitoring assessment to compare medications for rapid sequence intubation (including thiopental and remifentanil) with morphine. Their findings demonstrate that morphine treatment causes longer cerebral depression, more discontinuous aEEG/EEG background activity, and a lack of SWC that lasts for 24 h in extremely preterm babies. Morphine dosages often used as analgesics exhibited a neurodepressive impact that lasted at least six hours.6262 Norman E, Wikström S, Rosén I, Fellman V, Hellström-Westas L. Premedication for intubation with morphine causes prolonged depression of electrocortical background activity in preterm infants. Pediatr Res. 2013;73:87–94. In recent research, Peled et al.6363 Peled M, Abuhatzira A, Novack L, Meledin I, Shany E. Effect of morphine on cerebral activity of extremely premature infants. Early Hum Dev. 2020;151:105241. found that six hours after morphine beginning, background aEEG activity score worsened in 40% of extremely preterm babies, and cycling, which was originally evident in 70% of the children, could only be identified in 10% after ten hours.6363 Peled M, Abuhatzira A, Novack L, Meledin I, Shany E. Effect of morphine on cerebral activity of extremely premature infants. Early Hum Dev. 2020;151:105241.

Yuan et al. have published a study on the potential predictive neurological prognostic value of early continuous aEEG in term and near-term infants with severe hyperbilirubinemia. They discovered that early aEEG had a sensitivity of 35.7% and a specificity of 92.0% in predicting poor neurodevelopmental outcomes in newborns with severe hyperbilirubinemia. On the other hand, the sensitivity was significantly lower than the auditory brainstem response.6464 Yuan X, Song J, Gao L, Cheng Y, Dong H, Zhang R, et al. Early amplitude-integrated electroencephalography predicts long-term outcomes in term and near-term newborns with severe hyperbilirubinemia. Pediatr Neurol. 2019;98:68–73.

Another common procedure that usually affects aEEG trace is surfactant administration, which often can lead to a noticeable but transient depression on brain activity lasting around ten minutes.6565 Hellström-Westas L, Bell AH, Skov L, Greisen G, Svenningsen NW. Cerebroelectrical depression following surfactant treatment in preterm neonates. Pediatrics. 1992;89:643–7.

From our point of view, every newborn with a disorder leading to the possibility of brain damage, with a risk of impacting the quality of life, will benefit from being monitored with aEEG, providing real-time information on brain function and seizure diagnosis, giving opportunity for immediate treatment with less chance of permanent neurological sequelae. It is survival with quality of life, impacting the child, family and society.

Limitations

The aEEG can be used as a screening tool for seizures, although brief, focused, and low-amplitude seizures may be missed.2929 Toet MC, Hellström-Westas L, Groenendaal F, Eken P, de Vries LS. Amplitude integrated EEG 3 and 6 h after birth in full term neonates with hypoxic-ischaemic encephalopathy. Arch Dis Child Fetal Neonatal Ed. 1999;81:F19–23. Moreover, in some specific clinical scenarios, seizure activity can arise from cerebral areas not covered by the aEEG electrodes, leading to false negatives. Using two-channel aEEG and correlating with raw EEG interpretation (with readers' expertise) is mandatory to increase sensibility and specificity.2020 Frenkel N, Friger M, Meledin I, Berger I, Marks K, Bassan H, et al. Neonatal seizure recognition-comparative study of continuousamplitude integrated EEG versus short conventional EEG recordings. Clin Neurophysiol. 2011;122:1091–7., 2323 Rakshasbhuvankar A, Paul S, Nagarajan L, Ghosh S, Rao S. Amplitude-integrated EEG for detection of neonatal seizures: a systematic review. Seizure. 2015;33:90–8. It is important to point out that full array continuous EEG remains the gold standard for seizures detection. Current technology and remote access possibilities may allow experienced specialists to provide long-term and distant assistance.

Conclusion

The aEEG has shown to be a useful non-invasive bedside monitor that aids in evaluating brain function, background activity, and cyclicity. In a group of critically sick neonates, aEEG data have also demonstrated high predictive value, particularly in babies with HIE, where aEEG might potentially assist select infants eligible for neuroprotective treatments such as therapeutic hypothermia. The seizure detection capability of the use of aEEG and its limitations have been accessed in many studies.

With the evolution of brain-focused neonatal care, including early diagnoses of brain injury and neuroprotective strategies, the use of bedside brain monitoring such as aEEG may be suitable for neonates at high risk in a large number of clinical situations.

References

  • 1
    Alderliesten T, Dix L, Baerts W, Caicedo A, van Huffel S, Naulaers G, et al. Reference values of regional cerebral oxygen saturation during the first 3 days of life in preterm neonates. Pediatr Res. 2016;79:55–64.
  • 2
    Triulzi F, Parazzini C, Righini A. Patterns of damage in the mature neonatal brain. Pediatr Radiol. 2006;36:608–20.
  • 3
    Ferriero DM. Neonatal brain injury. N Engl J Med. 2004;351: 1985–95.
  • 4
    Miller SP, Ramaswamy V, Michelson D, Barkovich AJ, Holshouser B, Wycliffe N, et al. Patterns of brain injury in term neonatal encephalopathy. J Pediatr. 2005;146:453–60.
  • 5
    Miller SP, Weiss J, Barnwell A, Ferriero DM, Latal-Hajnal B, Ferrer-Rogers A, et al. Seizure-associated brain injury in term newborns with perinatal asphyxia. Neurology. 2002;58:542–8.
  • 6
    Okereafor A, Allsop J, Counsell SJ, Fitzpatrick J, Azzopardi D, Rutherford MA, Cowan FM. Patterns of brain injury in neonates exposed to perinatal sentinel events. Pediatrics. 2008;121: 906–14.
  • 7
    Volpe JJ. Brain injury in premature infants: a complex amalgam of destructive and developmental disturbances. Lancet Neurol. 2009;8:110–24.
  • 8
    Volpe JJ. The encephalopathy of prematurity-brain injury and impaired brain development inextricably intertwined. Semin Pediatr Neurol. 2009;16:167–78.
  • 9
    Dimitropoulos A, McQuillen PS, Sethi V, Moosa A, Chau V, Xu D, et al. Brain injury and development in newborns with critical congenital heart disease. Neurology. 2013;81:241–8.
  • 10
    Miller SP, McQuillen PS, Hamrick S, Xu D, Glidden DV, Charlton N, et al. Abnormal brain development in newborns with congenital heart disease. N Engl J Med. 2007;357:1928–38.
  • 11
    Murray DM, O'Connor CM, Ryan CA, Korotchikova I, Boylan GB. Early EEG grade and outcome at 5 years after mild neonatal hypoxic ischemic encephalopathy. Pediatrics. 2016;138: e20160659.
  • 12
    Variane GF, Magalhães M, Gasperine R, Alves HC, Scoppetta TL, Figueredo RJ, et al. Early amplitude-integrated electroencephalography for monitoring neonates at high risk for brain injury. J Pediatr (Rio J). 2017;93:460–6.
  • 13
    Shellhaas RA, Clancy RR. Characterization of neonatal seizures by conventional EEG and single-channel EEG. Clin Neurophysiol. 2007;118:2156–61.
  • 14
    Patrizi S, Holmes GL, Orzalesi M, Allemand F. Neonatal seizures: characteristics of EEG ictal activity in preterm and fullterm infants. Brain Dev. 2003;25:427–37.
  • 15
    Kidokoro H, Inder T, Okumura A, Watanabe K. What does cyclicity on amplitude-integrated EEG mean? J Perinatol. 2012;32:565–9.
  • 16
    Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7.
  • 17
    Shah DK, Mackay MT, Lavery S, Watson S, Harvey AS, Zempel J, et al. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics. 2008;121:1146–54.
  • 18
    Toet MC, van der Meij W, de Vries LS, Uiterwaal CS, van Huffelen KC. Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates. Pediatrics. 2002;109:772–9.
  • 19
    Lawrence R, Mathur A, Nguyen The Tich S, Zempel J, Inder T. A pilot study of continuous limited-channel aEEG in term infants with encephalopathy. J Pediatr. 2009;154:835–41. e1.
  • 20
    Frenkel N, Friger M, Meledin I, Berger I, Marks K, Bassan H, et al. Neonatal seizure recognition-comparative study of continuousamplitude integrated EEG versus short conventional EEG recordings. Clin Neurophysiol. 2011;122:1091–7.
  • 21
    Glass HC, Wusthoff CJ, Shellhaas RA. Amplitude-integrated electro-encephalography: the child neurologist's perspective. J Child Neurol. 2013;28:1342–50.
  • 22
    Mastrangelo M, Fiocchi I, Fontana P, Gorgone G, Lista G, Belcastro V. Acute neonatal encephalopathy and seizures recurrence: a combined aEEG/EEG study. Seizure. 2013;22:703–7.
  • 23
    Rakshasbhuvankar A, Paul S, Nagarajan L, Ghosh S, Rao S. Amplitude-integrated EEG for detection of neonatal seizures: a systematic review. Seizure. 2015;33:90–8.
  • 24
    Rennie JM, Chorley G, Boylan GB, Pressler R, Nguyen Y, Hooper R. Non-expert use of the cerebral function monitor for neonatal seizure detection. Arch Dis Child Fetal Neonatal Ed. 2004;89: F37–40.
  • 25
    Clancy RR, Legido A, Lewis D. Occult neonatal seizures. Epilepsia. 1988;29:256–61.
  • 26
    García-Alix A, Martínez-Biarge M, Diez J, Gayá F, Quero J. Incidencia y prevalencia de la encefalopatía hipoxico-isquémica en la primera década del siglo XXI. Ann Pediatr (Barc). 2009;71:319–26.
  • 27
    Scher MS, Aso K, Beggarly ME, Hamid MY, Steppe DA, Painter MJ. Electrographic seizures in preterm and full-term neonates: clinical correlates, associated brain lesions, and risk for neurologic sequelae. Pediatrics. 1993;91:128–34.
  • 28
    al Naqeeb N, Edwards AD, Cowan FM, Azzopardi D. Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography. Pediatrics. 1999;103:1263–71.
  • 29
    Toet MC, Hellström-Westas L, Groenendaal F, Eken P, de Vries LS. Amplitude integrated EEG 3 and 6 h after birth in full term neonates with hypoxic-ischaemic encephalopathy. Arch Dis Child Fetal Neonatal Ed. 1999;81:F19–23.
  • 30
    Hellström-Westas L, Rosén I, Svenningsen NW. Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants. Arch Dis Child Fetal Neonatal Ed. 1995;72:F34–8.
  • 31
    Spitzmiller RE, Phillips T, Meinzen-Derr J, Hoath SB. Amplitudeintegrated EEG is useful in predicting neurodevelopmental outcome in full-term infants with hypoxic-ischemic encephalopathy: a meta-analysis. J Child Neurol. 2007;22:1069–78.
  • 32
    Thoresen M, Hellstrom-Westas L, Liu X, de Vries LS. Effect of hypothermia on amplitude-integrated electroencephalogram in infants with asphyxia. Pediatrics. 2010;126:e131–9.
  • 33
    Csekő AJ, Bangó M, Lakatos P, Kárdási J, Pusztai L, Szabó M. Accuracy of amplitude-integrated electroencephalography in the prediction of neurodevelopmental outcome in asphyxiated infants receiving hypothermia treatment. Acta Paediatr. 2013;102:707–11.
  • 34
    Chandrasekaran M, Chaban B, Montaldo P, Thayyil S. Predictive value of amplitude-integrated EEG (aEEG) after rescue hypothermic neuroprotection for hypoxic ischemic encephalopathy: a meta-analysis. J Perinatol. 2017;37:684–9.
  • 35
    Del Río R, Ochoa C, Alarcon A, Arnáez J, Blanco D, García-Alix A. Amplitude integrated electroencephalogram as a prognostic tool in neonates with hypoxic-ischemic encephalopathy: a systematic review. PLoS One. 2016;11:e0165744.
  • 36
    Jacobs SE, Berg M, Hunt R, Tarnow-Mordi WO, Inder TE, Davis PG. Cooling for newborns with hypoxic ischaemic encephalopathy. Cochrane Database Syst Rev. 2013;2013:CD003311.
  • 37
    Azzopardi DV, Strohm B, Edwards AD, Dyet L, Halliday HL, Juszczak E, et al. Moderate hypothermia to treat perinatal asphyxial encephalopathy. N Engl J Med. 2009;361:1349–58.
  • 38
    Gluckman PD, Wyatt JS, Azzopardi D, Ballard R, Edwards AD, Ferriero DM, et al. Selective head cooling with mild systemic hypothermia after neonatal encephalopathy: multicentre randomised trial. Lancet. 2005;365:663–70.
  • 39
    Skranes JH, Løhaugen G, Schumacher EM, Osredkar D, Server A, Cowan FM, et al. Amplitude-integrated electroencephalography improves the identification of infants with encephalopathy for therapeutic hypothermia and predicts neurodevelopmental outcomes at 2 years of age. J Pediatr. 2017;187:34–42.
  • 40
    Verma UL, Archbald F, Tejani NA, Handwerker SM. Cerebral function monitor in the neonate. I: normal patterns. Dev Med Child Neurol. 1984;26:154–61.
  • 41
    Hellström-Westas L, Rosén I, Svenningsen NW. Cerebral function monitoring during the first week of life in extremely small low birthweight (ESLBW) infants. Neuropediatrics. 1991;22:27–32.
  • 42
    Scoppa A, Casani A, Cocca F, Coletta C, De Luca MG, Di Manso G, et al. aEEG in preterm infants. J Matern Fetal Neonatal Med. 2012;25:139–40.
  • 43
    Olischar M, Klebermass K, Kuhle S, Hulek M, Kohlhauser C, Rucklinger E, et al. Reference values for amplitude-integrated electroencephalographic activity in preterm infants younger than 30 weeks' gestational age. Pediatrics. 2004;113:e61–6.
  • 44
    Burdjalov VF, Baumgart S, Spitzer AR. Cerebral function monitoring: a new scoring system for the evaluation of brain maturation in neonates. Pediatrics. 2003;112:855–61.
  • 45
    Tao JD, Mathur AM. Using amplitude-integrated EEG in neonatal intensive care. J Perinatol. 2010;30:S73–81.
  • 46
    Weeke LC, van Ooijen IM, Groenendaal F, van Huffelen AC, van Haastert IC, van Stam C, et al. Rhythmic EEG patterns in extremely preterm infants: classification and association with brain injury and outcome. Clin Neurophysiol. 2017;128:2428–35.
  • 47
    Lloyd RO, O'Toole JM, Pavlidis E, Filan PM, Boylan GB. Electrographic seizures during the early postnatal period in preterm infants. J Pediatr. 2017;187:18–25. e2.
  • 48
    Shah DK, Zempel J, Barton T, Lukas K, Inder TE. Electrographic seizures in preterm infants during the first week of life are associated with cerebral injury. Pediatr Res. 2010;67:102–6.
  • 49
    Vesoulis ZA, Inder TE, Woodward LJ, Buse B, Vavasseur C, Mathur AM. Early electrographic seizures, brain injury, and neurodevelopmental risk in the very preterm infant. Pediatr Res. 2014;75:564–9.
  • 50
    Tekgul H, Gauvreau K, Soul J, Murphy L, Robertson R, Stewart J, et al. The current etiologic profile and neurodevelopmental outcome of seizures in term newborn infants. Pediatrics. 2006;117:1270–80.
  • 51
    Davis AS, HintzSR, Van Meurs KP, Li L, Das A, Stoll BJ, etal. Seizures in extremely low birth weight infants are associated with adverse outcome. J Pediatr. 2010;157:720–5.e1-2.
  • 52
    Meledin I, Tzur-Sebton H, Noyman I, Friger M, Hazan G, Shany E. Seizures in premature infants born at less than 28 weeks' gestation. Neonatology. 2019;115:247–55.
  • 53
    Wikström S, Pupp IH, Rosén I, Norman E, Fellman V, Ley D, et al. Early single-channel aEEG/EEG predicts outcome in very preterm infants. Acta Paediatr. 2012;101:719–26.
  • 54
    Soubasi V, Mitsakis K, Sarafidis K, Griva M, Nakas CT, Drossou V Early abnormal amplitude-integrated electroencephalography (aEEG) is associated with adverse short-term outcome in premature infants. Eur J Paediatr Neurol. 2012;16:625–30.
  • 55
    Klebermass K, Olischar M, Waldhoer T, Fuiko R, Pollak A, WeningerM. Amplitude-integrated EEG pattern predicts further outcome in preterm infants. Pediatr Res. 2011;70:102–8.
  • 56
    Wernovsky G, Shillingford AJ, Gaynor JW. Central nervous system outcomes in children with complex congenital heart disease. CurrOpin Cardiol. 2005;20:94–9.
  • 57
    Gunn JK, Beca J, Hunt RW, Olischar M, Shekerdemian LS. Perioperative amplitude-integrated EEG and neurodevelopment in infants with congenital heart disease. Intensive Care Med. 2012;38:1539–47.
  • 58
    Latal B, Wohlrab G, Brotschi B, Beck I, Knirsch W, Bernet V Postoperative amplitude-integrated electroencephalography predicts four-year neurodevelopmental outcome in children with complex congenital heart disease. J Pediatr. 2016;178: 55–60. e1.
  • 59
    Olischar M, Shany E, Aygun C, Azzopardi D, Hunt RW, Toet MC, et al. Amplitude-integrated electroencephalography in newborns with inborn errors of metabolism. Neonatology. 2012;102: 203–11.
  • 60
    Helderman JB, Welch CD, Leng X, O'Shea TM. Sepsis-associated electroencephalographic changes in extremely low gestational age neonates. Early Hum Dev. 2010;86:509–13.
  • 61
    Toso PA, González AJ, Pérez ME, Kattan J, Fabres JG, Tapia JL, et al. Clinical utility of early amplitude integrated EEG in monitoring term newborns at risk of neurological injury. J Pediatr (Rio J). 2014;90:143–8.
  • 62
    Norman E, Wikström S, Rosén I, Fellman V, Hellström-Westas L. Premedication for intubation with morphine causes prolonged depression of electrocortical background activity in preterm infants. Pediatr Res. 2013;73:87–94.
  • 63
    Peled M, Abuhatzira A, Novack L, Meledin I, Shany E. Effect of morphine on cerebral activity of extremely premature infants. Early Hum Dev. 2020;151:105241.
  • 64
    Yuan X, Song J, Gao L, Cheng Y, Dong H, Zhang R, et al. Early amplitude-integrated electroencephalography predicts long-term outcomes in term and near-term newborns with severe hyperbilirubinemia. Pediatr Neurol. 2019;98:68–73.
  • 65
    Hellström-Westas L, Bell AH, Skov L, Greisen G, Svenningsen NW. Cerebroelectrical depression following surfactant treatment in preterm neonates. Pediatrics. 1992;89:643–7.

Publication Dates

  • Publication in this collection
    05 Dec 2022
  • Date of issue
    Nov-Dec 2022

History

  • Received
    22 Dec 2020
  • Accepted
    21 Oct 2021
  • Published
    02 Jan 2022
Sociedade Brasileira de Pediatria Av. Carlos Gomes, 328 cj. 304, 90480-000 Porto Alegre RS Brazil, Tel.: +55 51 3328-9520 - Porto Alegre - RS - Brazil