Acessibilidade / Reportar erro

Comparison of enflurane and propofol in electroconvulsive therapy, a randomized crossover open preliminary study on seizure duration and anaesthetic recovery: un estudio preliminar, aleatorio, abierto y cruzado sobre la duración de las convulsiones y la recuperación Anestésica

Abstracts

BACKGROUND AND OBJECTIVES: Electroconvulsive therapy (ECT) is commonly used for treatment of depression, mania and affective disorders. Anaesthetics for general anaesthesia during ECT should have rapid onset, rapid emerge, not interfere with seizure activity and not shorten seizure duration. The aim of this study is to compare effects of enflurane, a pro-convulsive anaesthetic agent, and propofol on seizure durations, postictal suppression index and recovery times during electroconvulsive therapy. METHODS: Unpremedicated subjects were divided into two groups according to induction of anaesthesia. Patients were induced for ECT with 5% enflurane in group E and 1.2 mg.kg-1 propofol in group P until loss of consciousness. The durations of electroencephalogram (EEG) and motor seizures, postictal suppression index, time to spontaneous breathing, duration of eye opening, and obeying commands were recorded. RESULTS: There was no statistically significant difference between the groups regarding motor and EEG seizure times and postictal suppression index on the EEG records. Recovery times (times of starting spontaneous breathing, eye opening, and obeying command) were significantly shorter in group E compared to group P. No nausea or vomiting were observed and no ECG abnormality was noted except transient sinus bradycardia and sinus tachycardia. CONCLUSIONS: Although sufficient seizure for the treatment was provided during enflurane anaesthesia, any additional benefit was not revealed regarding seizure times or postictal suppression index when compared to propofol anaesthesia. On the other hand, recovery times after enflurane anaesthesia were shorter than propofol anaesthesia. However, there is still a need for further study in different ETCO2 levels.

Electroconvulsive Therapy; General Anesthesia, General; Propofol; Enflurane


JUSTIFICATIVA E OBJETIVOS: A eletroconvulsoterapia (ECT) é comumente utilizada para o tratamento de depressão, mania e transtornos do humor. Anestésicos para anestesia geral durante a ECT devem ter início e despertar rápidos, não interferir com a atividade da convulsão e não encurtar a duração das crises. O objetivo deste estudo é comparar os efeitos do enflurano, um agente anestésico pró-convulsivo, e o propofol na duração das ocnvulsões, no índice de supressão pós-ictal e nos tempos de recuperação durante a eletroconvulsoterapia. MÉTODO: Pacientes sem uso de medicação pré-anestésica foram alocados em dois grupos de acordo com a indução da anestesia. Os pacientes foram induzidos para a ECT com 5% de enflurano no grupo E e 1,2 mg.kg-1 de propofol no grupo P, até perda de consciência. A duração das crises motora e no eletroencefalograma (EEG), o índice de supressão pós-ictal, o tempo para respiração espontânea, para duração da abertura dos olhos e obedecer aos comandos foram registrados. RESULTADOS: Não houve diferença estatisticamente significativa entre os grupos quanto aos tempos das crises motora e no EEG e índice de supressão pós-ictal nos registros de EEG. Tempos de recuperação (tempo de início de respiração espontânea, de abertura dos olhos e para obedecer aos comandos) foram significativamente menores no grupo E em relação ao grupo P. Não foram observados náuseas ou vômitos e nenhuma anormalidade no ECG, exceto bradicardia sinusal transitória e taquicardia sinusal. CONCLUSÕES: Embora convulsões suficientes para o tratamento tenham ocorrido durante a anestesia com enflurano, nenhum benefício adicional foi observado sobre os tempos de convulsão ou índice de supressão pós-ictal quando comparado à anestesia com propofol. Por outro lado, o tempo de recuperação após anestesia com enflurano foi mais curto que com propofol. No entanto, ainda há necessidade de mais estudos em diferentes níveis de ETCO2.

ANESTESIA; ANESTÉSICOS; ANESTÉSICOS; ANESTÉSICOS; ANESTÉSICOS; TRATAMENTO


JUSTIFICATIVA Y OBJETIVOS: La electroconvulsoterapia (ECT), se usa a menudo para el tratamiento de la depresión, manía y transtornos del humor. Los anestésicos para la anestesia general durante la ECT deben tener un inicio y un despertar rápidos, no interferir en la actividad de la convulsión y no acortar la duración de las crises. El objetivo de este estudio, es comparar los efectos del enflurano, un agente anestésico pro convulsivo, y el propofol, en la duración de las convulsiones, en el índice de supresión postictal y en los tiempos de recuperación durante la electroconvulsoterapia. MÉTODO: Pacientes sin uso de medicación preanestésica que fueron colocados en dos grupos de acuerdo con la inducción de la anestesia. Los pacientes fueron inducidos para la ECT con 5% de enflurano en el grupo E y 1,2 mg.kg-1 de propofol en el grupo P, hasta la pérdida de la conciencia. También fueron registrados la duración de las crises motora y en el electroencefalograma (EEG), el índice de supresión postictal, el tiempo para la respiración espontánea, para la duración de la abertura de los ojos y obedecer a los comandos. RESULTADOS: No hubo diferencia estadísticamente significativa entre los grupos en cuanto a los tiempos de las crises motora y en el EEG e índice de supresión postictal en los registros de EEG. Los tiempos de recuperación (tiempo de inicio de la respiración espontánea, de abertura de los ojos, y para obedecer a los comandos), fueron significativamente menores en el grupo E con relación al grupo P. No se observaron náuseas o vómitos, ni ninguna anormalidad en el ECG tampoco fue notada, excepto bradicardia sinusal transitoria y taquicardia sinusal. CONCLUSIONES: Aunque las convulsiones suficientes para el tratamiento hayan sucedido durante la anestesia con enflurano, ningún beneficio adicional fue observado sobre los tiempos de convulsión o sobre el índice de supresión postictal cuando se le comparó con la anestesia con propofol. Por otro lado, el tiempo de recuperación después de la anestesia con enflurano fue más corto que con el propofol. Sin embargo, todavía se hacen necesarios más estudios en diferentes niveles de ETCO2.

ANESTESIA; ANESTÉSICOS; ANESTÉSICOS; ANESTÉSICOS; TRATAMIENTO


SCIENTIFIC ARTICLE

IMD; Assist. Prof. Benzmiâlem Vakif Üniversitesi, Faculty of Medicine, Department of Anaesthesiology, Istanbul, Turkey

IIMD; Assist. Prof. Kahramanmara Sütçü mam Üniversitesi, Faculty of Medicine, Department of Anaesthesiology, Kahramanmaras, Turkey

IIIMD; Clinical Resident Kahramanmara Sütçü mam Üniversitesi, Faculty of Medicine, Department of Anaesthesiology, Kahramanmaras, Turkey

IVMD; Clinical Resident Kahramanmara Sütçü mam Üniversitesi, Faculty of Medicine, Department of Psychiatry, Kahramanmaras, Turkey

Correspondence to

SUMMARY

BACKGROUND AND OBJECTIVES: Electroconvulsive therapy (ECT) is commonly used for treatment of depression, mania and affective disorders. Anaesthetics for general anaesthesia during ECT should have rapid onset, rapid emerge, not interfere with seizure activity and not shorten seizure duration. The aim of this study is to compare effects of enflurane, a pro-convulsive anaesthetic agent, and propofol on seizure durations, postictal suppression index and recovery times during electroconvulsive therapy.

METHODS: Unpremedicated subjects were divided into two groups according to induction of anaesthesia. Patients were induced for ECT with 5% enflurane in group E and 1.2 mg.kg-1 propofol in group P until loss of consciousness. The durations of electroencephalogram (EEG) and motor seizures, postictal suppression index, time to spontaneous breathing, duration of eye opening, and obeying commands were recorded.

RESULTS: There was no statistically significant difference between the groups regarding motor and EEG seizure times and postictal suppression index on the EEG records. Recovery times (times of starting spontaneous breathing, eye opening, and obeying command) were significantly shorter in group E compared to group P. No nausea or vomiting were observed and no ECG abnormality was noted except transient sinus bradycardia and sinus tachycardia.

CONCLUSIONS: Although sufficient seizure for the treatment was provided during enflurane anaesthesia, any additional benefit was not revealed regarding seizure times or postictal suppression index when compared to propofol anaesthesia. On the other hand, recovery times after enflurane anaesthesia were shorter than propofol anaesthesia. However, there is still a need for further study in different ETCO2 levels.

Keywords: Electroconvulsive Therapy; General Anesthesia, General; Propofol; Enflurane.

INTRODUCTION

Electroconvulsive therapy (ECT) is commonly used for treatment of depression, mania and affective disorders. The brain is subjected to seizure activity induced by the electric current, and adequate seizures are necessary for a therapeutic response 1,2. Although the mechanism of action is not clearly understood, a definite correlation between seizure duration and clinical outcome remains to be demonstrated. Because these factors alone are not necessarily a predictor of outcome, adequate seizures are supposed to be more efficacious. Motor seizure duration greater than 25 seconds has been recommended to ensure clinical adequacy of treatment, and short seizures are considered negative predictors of outcome 1,3.

Anaesthetics, which are used for general anaesthesia during ECT, should have rapid onset, rapid emergence, not interfere with seizure activity, and not shorten seizure duration. Since most short-acting anaesthetics have anticonvulsant effects, they can increase the threshold and inhibit the spread of seizure, thus modifying the seizure activity and shorten its duration 1.

Propofol is widely used in ECT anaesthesia as a reference agent due to characteristics such as rapid onset and emergence from anaesthesia, minimal postoperative confusion and a lower incidence of hypertension or tachycardia during induction of anaesthesia. However, it produces a dose-dependent decrease in seizure duration 1,3.

Enflurane is a volatile anaesthetic that could be used for induction of anaesthesia 4-6. Enflurane, unlike other commonly used inhalation anaesthetics, may precipitate seizure activity on the electroencephalogram with high amplitude spike wave complexes with burst suppression. Even in some patients, convulsive myoclonic movements during anaesthesia have been observed 7-11. There is not any trial in PubMed about enflurane anaesthesia during ECT procedure.

The aim of this study was to compare the effect of enflurane, a proconvulsive anaesthetic agent, and propofol, as a reference anaesthetic agent, on seizure durations, haemodynamic status, postictal suppression index, and recovery times after electroconvulsive therapy.

METHODS

After the Faculty Ethics Committee approval, patients scheduled by Psychiatry Clinic for ECT were enrolled for second to fifth ECT. Written informed consent was provided from the patients who were able to provide the consent. The trial was conducted as a prospective open technique. Exclusion criteria included mask intolerance, seizure disorder, obesity (body mass index > 30), gastroesophageal reflux disease resistant to pharmacotherapy, current alcohol or other substance usage, unstable cardiovascular disease, chronic obstructive pulmonary disease, renal or hepatic failure, and organic brain disease.

Ten patients with major depression were included the study. No patient was premedicated. Randomization was performed by a consultant anaesthesiologist using a sealed envelope technique before the first session because of the crossover design. The subjects were divided into two groups according to induction anaesthetics of second ECT. At the first session, suprathreshold electrical stimulus was detected and then, two agents were alternated over the remaining four sessions of ECT as crossover design. After routine monitorization and preparation, general anaesthesia was induced with 5% enflurane in group E and 1.2 mg.kg-1 propofol in group P until loss of consciousness. Loss of consciousness was defined as both loss of the eyelid reflex and no response to the verbal command, e.g., ''open your eyes''. After loss of consciousness, enflurane was firstly lowered to 2% in group E. No additional propofol was needed to assure loss of eyelid reflex. After loss of consciousness, a pressure cuff was applied to the arm and inflated above the systolic arterial pressure to isolate the circulation of the arm, and to permit an accurate assessment of the motor seizure. Muscle relaxation was achieved with succinylcholine 0.5 mg.kg-1. After resolution of muscle fasciculation, enflurane was stopped in group E.

A bite blocker was inserted before the session, and ventilation was assisted manually using a face mask with 100% oxygen at 6 L.min-1 fresh gas flows in all groups. The patients were maintained in normocapnia. After the anaesthesia for ECT in group E, anaesthetic system was cleared by fresh oxygen.

Noninvasive mean arterial pressure (MAP) and heart rate (HR) values were recorded before induction of anaesthesia (baseline), one minute after induction, and one, five and ten minu tes after ECT. Just before ECT, end-tidal CO2 and endtidal enflurane concentration in the last breath were recorded using Cardiocap 5 monitor (Datex Ohmeda, Louisville, USA).

Before the trial, each patient's ECT-induced seizure threshold was determined by administering successive stimuli of increasing intensity at 30-second intervals until a gene ralized motor seizure was induced (threshold stimulus) in the first session. The suprathreshold stimulus (one level higher intensity than the threshold stimulus) was used throughout the study and was maintained constantly for each patient.

The suprathreshold electrical stimulus was delivered via bifrontotemporal electrodes using a Thymatron System IV machine (Somatics, Inc., Lake Bluff, IL, USA) by the referring psychiatrist immediately after resolution of muscle fasciculation. The duration of seizure was recorded as the time from the ECT stimulus to cessation of electroencephalogram (EEG) activity. Motor seizure activity was recorded according to the cuff method defined above. Postictal suppression indexes on EEG records, time of spontaneous breathing, eye opening, and obeying commands were recorded.

Assuming an alpha level of 0.05 with a power of 0.80, a minimum of 17 data in each group were required to detect a mean difference of 5 sec and standard deviation of 5 sec for the seizure duration between the two groups. The statistical analysis of data was performed with SPSS 11.0 (SPSS Inc., Chicago, IL, USA). Data are expressed as mean ± SD or absolute values. The independent-sample t-test was used for comparisons between groups. Data were analyzed using repeated-measures analysis of variance with Bonferroni correction. A value of p < 0.05 was considered as significant.

RESULTS

Ten patients, four male and six female, with a mean age of 36.80 ± 11.14 years (range 23 to 59) and weight of 79.60 ± 14.98 kg (range 62 to 95) received a total of fourty ECT sessions. Hemodynamic variables are shown in Table I. Seizure data and recovery times after ECT in both groups are shown in Table II.

Mean arterial pressure and heart rate were significantly higher in group E only at one min after induction. On the other hand, mean arterial pressure and heart rate were significantly higher in both groups at only one min following ECT when compared to baseline values. Also in group E, heart rate at one min after induction was significantly higher compared to baseline value. Haemodynamic values at baseline, five and ten min after ECT, were similar in both groups (Table I).

There were no significant differences between groups regarding motor and EEG seizure times and postictal suppression index on the EEG records (Table II).

Recovery times (times of starting spontaneous breathing, eye opening, and obeying command) were significantly shorter in group E with powers of 96%, 100%, and 100%, respectively (Table II). No nausea or vomiting was observed and no ECG abnormality was noted, except transient sinus bradycardia and sinus tachycardia.

DISCUSSION

There are multiple factors affecting the choice of anaesthesia in ECT, including seizure length, hemodynamics, and recovery times.

Induction of anesthesia could be provided by mask anesthesia in patients with needle-phobia in whom multiple attempts are required for successful placement of the intravenous catheter because of agitation or obesity 12. Mask anesthesia with sevoflurane was performed in ECT procedure and favourable results were reported 12-16. Enflurane is another volatile anesthetic that could be used in anesthesia induction in children 4 and adult 5,6 patients.

Unlike most other anaesthetics, previous animal 17 and epileptic human 10 studies and normal human reports 7 have shown a high incidence of spike activity on EEG and grand mal seizure patterns induced by enflurane. The findings with enflurane have also been confirmed in patients with temporal lobe epilepsy during both electrocorticographic and depth electrode recordings. In ten healthy volunteers, grand mal seizure patterns were precipitated by auditory, visual, and tactile stimulation at end-tidal enflurane concentrations of 3%-6%. With an alveolar enflurane concentration between 2.5% and 3%, hyperventilation to an average PaCO2 of 22 torr (mmHg) produced an increase in the frequency, magnitude, and synchrony of the spiking activity in epileptics 7. This technique has since been used to activate silent epileptogenic foci intraoperatively, to delineate the site of seizure activity before discrete surgical excision 11. So it was presumed that enflurane may increase duration of convulsion during ECT and no literature was found in PubMed about enflurane for ECT. In this paper, propofol was a reference anaesthetic agent used in many anaesthesia clinics for ECT.

The result revealed that enflurane anaesthesia assures satisfactory motor and EEG seizures. But there was no significantly difference in motor and EEG seizure times compared to propofol anaesthesia. Because enflurane is known to increase seizure activity, it is expected that seizure durations are longer than in propofol group. This could be explained by the epileptic activity associated with enflurane anaesthesia, which was particularly likely to occur with high concentrations of enflurane and in the presence of hypo- or hypercapnia 7,9,11. Ventilation in this study was maintained via face mask manual ly assisted in order to obtain normal ETCO2 level, so that hypo- or hypercapnia were not allowed. Hypocapnia might have increased the duration of convulsions 18; however, it would be technically difficult to provide and to detect exactly by mask ventilation, and may affect haemodynamics and perfusion. On the other hand, this effect was shown during sevoflurane anaesthesia, and seen only in the first session of treatment in that study 18. The relationship between enflurane concentration, PaCO2, and epileptiform activity was evaluated in a volunteer study 7. It was demonstrated that the minimum epileptogenic enflurane concentration was approximately 1% lower when PaCO2 was 20 torr (vs normocarbia), and 1% higher when PaCO2 was 60 torr.

Hemodynamic variables during ECT depend on generalized autonomic nervous system stimulation, with an initial parasympathetic-induced bradycardia lasting 10 to 15 seconds, followed immediately by a more prominent sympathetic response. Therefore, blood pressure and HR are transiently increased by 20-30% or more 19. In this study, haemodynamic values were not different except at the first minute after anaesthetic induction between the groups congruently. Enflurane represents an intermediate values between isoflurane and sevoflurane with respect to the circulatory changes 6. On the other hand, there was a haemodynamic compromise at the first minute after ECT in both groups when compared to baseline value in our study. In a previous study 13, there were significant elevations in sevoflurane group after one and ten mi nutes ECT, but these elevations were not seen in 1.5 mg.kg-1 of propofol group. This was probably a result of slow increasing and rapid decreasing the alveolar concentration of volatile anaesthetics with respiration. In the current study, propofol dose was lowered to 1.2 mg.kg-1 in order to not decrease seizure durations. This could be a reason for tachycardia at the first minute after ECT procedure.

In addition, mean arterial pressure and heart rate were significantly higher in group E only at one min after induction when compared to group P. This could be probably a result of mask induction. During mask induction in the first minute, because patients were not exactly unconscious yet, this could be considered as an acceptable reaction. On the other hand, in Toprak's study 13, in sevoflurane group at the first min after induction this reaction was not seen. This could be explained with blood-gas partition coefficient that is 0.65 and 1.5 for sevoflurane and enflurane respectively 20.

Although there is not exact relationship between postictal suppression and outcome, greater postictal suppression was accepted to be associated with favourable ECT outcome 21. In this study, not only seizure time but postictal suppression index in group E was acceptable level, but not significantly different compared to group P as well. Gazdag et al. 22 determined that postictal suppression index of propofol was 86%.

Because of shortness of ECT procedure an anaesthetic agent that has rapid recovery should be of choice. In this respect, succinylcholine is preferred as neuromuscular blocker. Otherwise, succinylcholine is not effective on seizure duration, post-seizure recovery and hemodynamics 12. For rapid recovery, propofol is preferred in our clinic for ECT sessions. Methohexital was approved as another reference anaesthetic agent for ECT 19. In our country, methohexital is not established for routine use.

In Toprak's study 13 propofol's recovery profile was similar to sevoflurane's. Inhalation anaesthetics could not be stored in lipose tissue in this short time. After discontinuation of inhalation anaesthetics, they are exhaled from lungs rapidly, and then blood concentration of inhalation anaesthetics is too low to unconsciousness and to assure anaesthesia. In order to assure the anaesthesia enflurane was not stopped just lowered in group E. Recovery times of patients (starting spontaneous breathing, eye opening, and obeying commands) were shorter in enflurane group than in propofol group in our study. These were also probably results of rapid decreasing the alveolar concentration of enflurane by respiration and/or residual effect of propofol. Because we lowered to 2% of enflurane after loss of conscious, it could be another reason of this rapid recovery. In Toprak's study sevoflurane was inhaled at 7%, but we do not know what they did after loss of conscious.

The present study has several limitations. Enflurane is an obsolete anaesthetic agent. Proconvulsive property of enflurane guided the study, and the convulsive effect of enflurane must have been evaluated during ECT in this aspect. On the other hand, the trial had been designed as open trial, because of the drugs' nature used. Moreover, as this was a preliminary study, the number of patient may not be sufficient for an accurate outcome.

In conclusion, although high incidence of spike activity on EEG and grand mal seizure patterns could be induced by enflurane, motor and EEG seizure times or postictal suppression index were not increased by enflurane in the presence of normocapnia when compared to propofol anaesthesia. Although enflurane anaesthesia provided enough seizure for ECT, it did not provide additional beneficial effect regarding seizure times. In addition, recovery times were shorter than with propofol anaesthesia. However, there is still need for further study in different ETCO2 levels.

REFERENCES

  • 1. Akcaboy ZN, Akcaboy EY, YigitbasłB et al. - Effects of remifentanil and alfentanil on seizure duration, stimulus amplitudes and recovery parameters during ECT. Acta Anaesthesiol Scand, 2005;49:1068-1071.
  • 2. Waikar A, Davar B, Karhadkar C et al. - ECT without anaesthesia is unethical. Issues Med Ethics, 2003;11:41-43.
  • 3. Vishne T, Aronov S, Amiaz R et al. - Remifentanil supplementation of propofol during electroconvulsive therapy: effect on seizure duration and cardiovascular stability. J ECT, 2005;21:235-238.
  • 4. ONeill MP, Sharkey AJ, Fee JP et al. - A comparative study of enflurane and halothane in children. Anaesthesia, 1982;37:634-639.
  • 5. Chan MT, Mainland P, Gin T - Minimum alveolar concentration of halothane and enflurane are decreased in early pregnancy. Anesthesiology, 1996;85:782-786.
  • 6. Tanaka S, Tsuchida H, Nakabayashi K et al. - The effects of sevoflurane, isoflurane, halothane, and enflurane on hemodynamic responses during an inhaled induction of anesthesia via a mask in humans. Anesth Analg, 1996;82:821-826.
  • 7. Modica PA, Tempelhoff R, White PF - Pro- and anticonvulsant effects of anesthetics (Part I). Anesth Analg, 1990;70:303-15.
  • 8. Lerman J - Pharmacology of inhalational anaesthetics in infants and children. Paediatr Anaesth, 1992;3:191-203.
  • 9. Jenkins J, Milne AC - Convulsive reaction following enflurane anaesthesia. Anaesthesia, 1984;39:44-45.
  • 10. Ito BM, Sato S, Kufta CV et al. - Effect of isoflurane and enflurane on the electrocorticogram of epileptic patients. Neurology, 1988;38:924-928.
  • 11. Flemming DC, Fitzpatrick J, Fariello RG et al. - Diagnostic activation of epileptogenic foci by enflurane. Anesthesiology, 1980;52:431-433.
  • 12. Rasmussen KG, Spackman TN, Hooten WM - The clinical utility of inhalational anesthesia with sevoflurane in electroconvulsive therapy. J ECT, 2005;21:239-242.
  • 13. Toprak HI, Gedik E, Begeç Z et al. - Sevoflurane as an alternative anaesthetic for electroconvulsive therapy. J ECT, 2005;21:108-110.
  • 14. Calarge CA, Crowe RR, Gergis SD et al. - The comparative effects of sevoflurane and methohexital for electroconvulsive therapy. J ECT, 2003;19:221-225.
  • 15. Rasmussen KG, Laurila DR, Brady BM et al. - Seizure length with sevoflurane and thiopental for induction of general anesthesia in electroconvulsive therapy: a randomized double-blind trial. J ECT, 2006;22:240-242.
  • 16. Rasmussen KG, Laurila DR, Brady BM et al. - Anesthesia outcomes in a randomized double-blind trial of sevoflurane and thiopental for induction of general anesthesia in electroconvulsive therapy. J ECT, 2007;23:236-238.
  • 17. Voss LJ, Ludbrook G, Grant C et al. - Cerebral cortical effects of desflurane in sheep: comparison with isoflurane, sevoflurane and enflurane. Acta Anaesthesiol Scand, 2006;50:313-319.
  • 18. Sawayama E, Takahashi M, Inoue A et al. - Moderate hyperventilation prolongs electroencephalogram seizure duration of the first electroconvulsive therapy. J ECT, 2008;24:195-198.
  • 19. Ding Z, White PF - Anesthesia for electroconvulsive therapy. Anesth Analg, 2002;94:1351-1364.
  • 20. Forman SA, Mashour GA - Pharmacology of inhalational anesthetics. em: Longnecker DE, ed. Anesthesiology. New York, McGraw-Hill Companies, 2008;739-766.
  • 21. Nobler MS, Luber B, Moeller JR et al. - Quantitative EEG during seizures induced by electroconvulsive therapy: relations to treatment modality and clinical features. I. Global analyses. J ECT, 2000;16:211-228.
  • 22. Gazdag G, Kocsis N, Tolna J et al. - Etomidate versus propofol for electroconvulsive therapy in patients with schizophrenia. J ECT, 2004;20:225-229.
  • Comparison of enflurane and propofol in electroconvulsive therapy, a randomized crossover open preliminary study on seizure duration and anaesthetic recovery

    Zafer DoganI; Nimet SenogluII; Huseyin YildizII; Ismail CoskunerII; Nadiye UgurIII; Elif BiterIV; Hafize OksuzII
  • Publication Dates

    • Publication in this collection
      28 Sept 2011
    • Date of issue
      Oct 2011

    History

    • Received
      25 Jan 2011
    • Accepted
      14 Mar 2011
    Sociedade Brasileira de Anestesiologia R. Professor Alfredo Gomes, 36, 22251-080 Botafogo RJ Brasil, Tel: +55 21 2537-8100, Fax: +55 21 2537-8188 - Campinas - SP - Brazil
    E-mail: bjan@sbahq.org