Bronchial injury and pneumothorax after reintubation using an airway exchange catheter

Abstracts

BACKGROUND AND OBJECTIVES: We report a case of pneumothorax caused by a bronchial perforation during a reintubation using an airway exchange catheter (AEC) in a patient with a head and neck cancer. CASE REPORT: A 53 year old man with oropharynx carcinoma was admitted to ICU for severe pneumonia and severe acute respiratory distress syndrome (ARDS). The patient was recognized as a difficult-to-intubate patient and an endotracheal tube (ETT) was inserted through a bronchoscope. After one week of treatment, it was observed an endotracheal cuff perforation. Exchanging the endotracheal tube was necessary to achieve satisfactory pulmonary ventilation. An AEC Cook 14 was used to perform the reintubation. After reintubation, the patient presented a worsening in oxygen saturation and a chest radiography (CXR) revealed a large pneumothorax. A chest tube was inserted and we observed immediate improvement in oxygen saturation. A repeat CXR confirmed correct positioning of the chest tube and reexpansion of the right lung. A bronchoscopy performed showed a posterior laceration in the right main bronchus. The patient was extubated the following day. After four days, the chest tube was removed. A CXR performed a day after chest tube removal revealed a small right upper pneumothorax, but the patient remained asymptomatic. CONCLUSIONS: Airway exchange catheter is a valuable tool to handle with difficult-to-intubate patients. Although the physicians generally focus their attention in avoid barotrauma - caused by oxygen supplement or jet ventilation through AEC - concern for insertion technique can minimize life threatening complications and increase the safety of AEC.

Intubation, Intratracheal; Airway Management; Intensive Care; Anesthesia


JUSTIFICATIVA E OBJETIVOS: Relatamos um caso de pneumotórax causado por perfuração brônquica durante uma reintubação usando um cateter para troca da via aérea (CTVA) em um paciente com câncer de cabeça e pescoço. RELATO DE CASO: Paciente do sexo masculino, 53 anos, com carcinoma de orofaringe, foi internado na UTI com pneumonia grave e síndrome da angústia respiratória aguda (SARA). O paciente foi identificado como sendo de difícil intubação e uma sonda endotraqueal (SET) foi inserida através de um broncoscópio. Após uma semana de tratamento, observou-se ruptura do manguito endotraqueal. A troca da sonda endotraqueal foi necessária para obter uma ventilação pulmonar satisfatória. Um cateter para troca da via aérea (Cook, tamanho 14) foi usado para realizar a reintubação. Depois da reintubação, o paciente apresentou piora na saturação de oxigênio e uma radiografia revelou um grande pneumotórax. Um dreno torácico foi inserido e uma melhora imediata na saturação de oxigênio foi observada. A repetição da radiografia confirmou o posicionamento correto do dreno torácico e a reexpansão do pulmão direito. A broncoscopia realizada mostrou uma laceração posterior do brônquio principal direito. O paciente foi extubado no dia seguinte. Depois de quatro dias, o dreno torácico foi removido. A radiografia realizada um dia depois da retirada do dreno revelou um pequeno pneumotórax no lobo superior direito, mas o paciente permaneceu assintomático. CONCLUSÕES: O cateter para troca da via aérea é uma ferramenta valiosa para lidar com pacientes difíceis de intubar. Embora os médicos geralmente concentrem sua atenção em evitar um barotrauma causado pelo suplemento de oxigênio ou ventilação a jato através do CTVA, a preocupação com a técnica de inserção pode minimizar as complicações que ameaçam a vida e aumentar a segurança do CTVA.

ANESTESIA; INTUBAÇÃO TRAQUEAL; Manuseio das Vias Aéreas; TERAPIA INTENSIVA


JUSTIFICATIVA Y OBJETIVOS: Relatamos aquí un caso de neumotórax causado por perforación brónquica durante una reintubación usando un catéter para el cambio de la vía aérea (CTVA) en una paciente con cáncer de cabeza y cuello. RELATO DE CASO: Paciente del sexo masculino, 53 años, con carcinoma de orofaringe, que fue ingresado en la UTI con neumonía grave y el síndrome de la angustia respiratoria aguda (SARA). El paciente fue identificado como siendo de difícil intubación y con un broncoscopio se le insertó una sonda endotraqueal (SET). Después de una semana de tratamiento, vimos una ruptura del manguito endotraqueal. El cambio de la sonda endotraqueal se hizo necesario para obtener una ventilación pulmonar satisfactoria. Un catéter para el cambio de la vía aérea (Cook, tamaño 14) se usó para realizar la reintubación. Después de la reintubación, el paciente tuvo un empeoramiento en la saturación de oxígeno y una radiografía reveló un fuerte neumotórax. Un dreno torácico se insertó observando una mejoría inmediata en la saturación de oxígeno. La repetición de la radiografía confirmó el posicionamiento correcto del dreno torácico y la re-expansión del pulmón derecho. La broncoscopia realizada arrojó una laceración posterior del bronquio principal derecho. El paciente se desentubó al día siguiente. Después de cuatro días, el dreno torácico se retiró. La radiografía realizada un día después de la retirada del dreno reveló un pequeño neumotórax en el lóbulo superior derecho, pero el paciente permaneció asintomático. CONCLUSIONES: El catéter para el cambio de la vía aérea es una herramienta valiosa para lidiar con los pacientes difíciles de intubar. Aunque los médicos generalmente concentren su atención en evitar un barotrauma causado por el suplemento de oxígeno o ventilación a chorro por medio del CTVA, la preocupación con la técnica de inserción puede minimizar las complicaciones que amenazan la vida y aumentar la seguridad del CTVA.

ANESTESIA; Manejo de Vía Aérea; CUIDADOS INTENSIVOS; INTUBACIÓN TRAQUEAL


CLINICAL INFORMATION

Instituto do Câncer do Estado de São Paulo (ICESP), Department of Anesthesiology and Critical Care, São Paulo, SP, Brazil

Corresponding author

ABSTRACT

BACKGROUND AND OBJECTIVES: We report a case of pneumothorax caused by a bronchial perforation during a reintubation using an airway exchange catheter (AEC) in a patient with a head and neck cancer.

CASE REPORT: A 53 year old man with oropharynx carcinoma was admitted to ICU for severe pneumonia and severe acute respiratory distress syndrome (ARDS). The patient was recognized as a difficult-to-intubate patient and an endotracheal tube (ETT) was inserted through a bronchoscope. After one week of treatment, it was observed an endotracheal cuff perforation. Exchanging the endotracheal tube was necessary to achieve satisfactory pulmonary ventilation. An AEC Cook 14 was used to perform the reintubation. After reintubation, the patient presented a worsening in oxygen saturation and a chest radiography (CXR) revealed a large pneumothorax. A chest tube was inserted and we observed immediate improvement in oxygen saturation. A repeat CXR confirmed correct positioning of the chest tube and reexpansion of the right lung. A bronchoscopy performed showed a posterior laceration in the right main bronchus. The patient was extubated the following day. After four days, the chest tube was removed. A CXR performed a day after chest tube removal revealed a small right upper pneumothorax, but the patient remained asymptomatic.

CONCLUSIONS: Airway exchange catheter is a valuable tool to handle with difficult-to-intubate patients. Although the physicians generally focus their attention in avoid barotrauma - caused by oxygen supplement or jet ventilation through AEC - concern for insertion technique can minimize life threatening complications and increase the safety of AEC.

Keywords: Intubation, Intratracheal; Airway Management; Intensive Care, Anesthesia.

Introduction

Exchange of endotracheal tube (ETT) in difficult-to-intubate patients is usually a challenge to physicians. A way to increase the safety of this procedure is using an airway exchange catheter (AEC). However, it is extremely important that physicians know which are the possible complications related the use of AEC.

There are many complications related to this procedure. Two categories are described: barotraumas and failure to pass the new ETT over the AEC. Pneumothorax, pneumomediastinum, pneumoperitoneum and even death have been reported 1. The aim of this case report is to alert the physicians of this life threatening complication from the use of AEC: perforation of tracheobronchial tree.

Case report

We report a case from the intensive care unit of the Instituto do Câncer do Estado de São Paulo (ICESP), Brazil.

A 53 year old man with oropharynx carcinoma was admitted to ICU for severe pneumonia and respiratory failure. He developed a severe acute respiratory distress syndrome (ARDS) and needed invasive mechanical ventilation. The patient was recognized as a difficult-to-intubate patient and an endotracheal tube (ETT) was inserted through a fiberoptic bronchoscope. After one week of treatment, endotracheal cuff perforation was observed, probably due to an altered airway anatomy and technique factors. Exchange of endotracheal tube was needed to achieve satisfactory pulmonary ventilation. The patient was sedated with fentanil, midazolam and paralyzed with cisatracurium. An AEC Cook 14 was used to perform the reintubation. There was no need to supplement oxygen through the AEC. After reintubation, the patient presented acute worsening in oxygen saturation and decreased air entry in the right hemithorax was detected on auscultation. A chest radiography (CXR) was performed and revealed a large pneumothorax (Figure 1). A chest tube was inserted and an immediate improvement in oxygen saturation was observed. A repeat CXR confirmed correct position of the chest tube and reexpansion of the right lung. A bronchoscopy was performed and showed a posterior laceration in the right main bronchus. The patient was extubated the following day. After four days, the chest tube was removed. A CXR performed one day after chest tube removal revealed a small right upper pneumothorax, but the patient remained asymptomatic.


Discussion

Reintubation is a common procedure in patients on intensive care unit (ICU).Serious complications can follow, by such as hypoxemia, airway injury, bleeding, laryngeal edema and difficulty in airway management 2. Patients with cancer, particularly those with head and neck cancer, represent a group with a higher incidence of difficult-to-intubate situation as compared to the general population 3. The airway exchange catheter is an effective and secure way to perform reintubation of patients with difficult airway.

Barotrauma and others complications derived from attempting to ventilate patients using an AEC are well-known and described extensively in literature. In fact, there are reports of up to 11% of patients developing barotrauma when the AEC is used with 50 psi jet ventilation 4.

Our patient developed a rare and serious adverse effect related to AEC use other than barotrauma: perforation of tracheobronchial tree. To our knowledge, there are only two previous reports on this complication 5,6. This may be due to misdiagnosis or in other cases it can be erroneously attributed to risk factors of the patient. In the specific population of cancer patients, complications due to AEC might be more frequent than previously reported and even relate to higher morbidity and mortality.

There are some simple but effective recommendations to avoid this serious complication: First, we should watch out for the depth of insertion of the AEC. The AEC must not be introduced further than 26 cm in an adult patient and if resistance to progress the tube is encountered, we should not to force it. A laryngoscope must be used to help the new endotracheal tube pass by the supraglottic structures and cord vocals. If the resistance continues, we must rotate the endotracheal tube counterclockwise ninety degrees because the tip of the tube can be hitting in the right cord vocal or arytenoids cartilages and, with this maneuver, you can pass over it 7.

Another way to increase the security of AEC is using a fiberoptic bronchoscope. The use of fiberoptic bronchoscope (FOB) beside the AEC may reduce the incidence of lower airway trauma. The visualization of the tip of the AEC by the FOB may avoid an overinsertion of the AEC and may increase successful tracheal intubations 8.

In conclusion, the airway exchange catheter is a valuable tool to handle difficult-to-intubate patients. Although physicians generally focus their attention in avoiding barotrauma

Bronchial Injury and Pneumothorax after Reintubation using an Airway Exchange Catheter caused by oxygen supplement or jet ventilation through AEC, concern for insertion technique can minimize life threatening complications - such as perforation of tracheobronquial tree - and increase the safety of AEC. The current report also illustrates an effective strategy of airway management in patients with cancer.

References

  • 1. Duggan LV, Law JA, Murphy MF - Brief review: supplementing oxygen through an airway exchange catheter: efficacy, complications, and recommendations. Can J Anaesth, 2011;58:560-568.
  • 2. Navalesi P, Frigerio P, Moretti MP et al. - Rate of reintubation in mechanically ventilated neurosurgical and neurologic patients: evaluation of a systematic approach to weaning and extubation. Crit Care Med, 2008;36(11):2986-2992.
  • 3. Huitink JM, Buitelaar DR, Schutte PF - Awake fibrecapnic intubation: a novel technique for intubation in head and neck cancer patients with a difficult airway. Anaesthesia, 2006;61(5):449-452.
  • 4. Cooper RM - The use of an endotracheal ventilation catheter in the management of difficult extubations. Can J Anaesth, 1996;43:90-93.
  • 5. DeLima I, Bishop M - Lung laceration after tracheal extubation over a plastic tube changer. Anesth Analg, 1991;73:350-351.
  • 6. Seita PA, Gravenstein N - Endobronchial rupture from endotracheal reintubation with an endotracheal tube guide. J Clin Anesth, 1989;1:214-217.
  • 7. Benumof JL - Airway exchange catheters: simple concept, potentially great danger. Anesthesiology, 1999;91(2):342-344.
  • 8. Ayoub CM, Lteif AM, Rizk MS, Abu-Jalad NM, Hadi U, Baraka AS - Facilitation of passing the endotracheal tube over the flexible fiberoptic bronchoscope using a Cook airway exchange catheter. Anesthesiology, 2002;96(6):1517-1518.
  • Bronchial injury and pneumothorax after reintubation using an airway exchange catheter

    Juliano P. de Almeida; Ludhmila A. Hajjar; Júlia T. Fukushima; Rosana E. Nakamura; Rodolfo Albertini; Filomena R. B. G. Galas
  • Publication Dates

    • Publication in this collection
      22 Feb 2013
    • Date of issue
      Feb 2013

    History

    • Received
      15 June 2011
    • Accepted
      18 Feb 2012
    Sociedade Brasileira de Anestesiologia R. Professor Alfredo Gomes, 36, 22251-080 Botafogo RJ Brasil, Tel: +55 21 2537-8100, Fax: +55 21 2537-8188 - Campinas - SP - Brazil
    E-mail: bjan@sbahq.org