Acessibilidade / Reportar erro

Reliability of point-of-care circulating cathodic antigen assay for diagnosing schistosomiasis mansoni in urine samples from an endemic area of Brazil after one year of storage at -20 degrees Celsius

ABSTRACT

Background

The World Health Organization recommends reliable point-of-care (POC) diagnostic testing to eliminate schistosomiasis. Lateral flow immunoassay that detects schistosome circulating cathodic antigen (CCA) in urine to establish prevalence thresholds for intervention in endemic areas is recommended. Stored urine may be useful if surveying at-risk populations is delayed or interrupted by unforeseen circumstances, such as the current COVID-19 pandemic. This study evaluated the manufacturer’s claim that Schistosoma mansoni infection can be reliably diagnosed in urine samples stored at -20°C for one year.

Methods

Two-hundred-forty-two subjects from an endemic site in Brazil provided one urine sample each for testing with URINE CCA (SCHISTO) ECO TESTE® (POC-ECO) and one stool sample each for testing with Kato-Katz (KK) and Helmintex® (HTX) as a robust reference standard for infection status. At least 2 ml of urine from each participant was stored at -20°C; after one year, 76 samples were randomly selected for POC-ECO retesting.

Results:

The POC-ECO agreement between freshly collected and stored urine was inadequate considering trace results as positive (Cohen’s kappa coefficient κ = 0.08) and negative (κ = 0.36). POC-ECO accuracy was not significantly greater than that of routine KK (54%; 95% confidence interval: 42.1%-65.5%).

Conclusions

The precision and accuracy of POC-ECO have to be optimized in both freshly collected and stored urine before it can be recommended for use in control programs in Brazil.

Keywords:
Schistosoma mansoni; Point-of-Care (POC) testing; Circulating Cathodic Antigen (CCA), frozen urine; Kato-Katz; Helmintex®; Brazil

INTRODUCTION

In 2020, the World Health Organization11. World Health Organization (WHO). Ending the neglect to attain the sustainable development goals: a road map for neglected tropical diseases 2021-2030. WHO. 2020. https://apps.who.int/iris/handle/10665/332094. License: CC BY-NC-SA 3.0 IGO
https://apps.who.int/iris/handle/10665/3...
launched a new 2021-2030 “road map” to hasten the elimination of neglected tropical diseases (NTDs), including schistosomiasis, as part of the Sustainable Development Goals (SDGs) Agenda. One key measure to eliminate schistosomiasis as a public health problem by 2030 is to develop standardized point-of-care diagnostics11. World Health Organization (WHO). Ending the neglect to attain the sustainable development goals: a road map for neglected tropical diseases 2021-2030. WHO. 2020. https://apps.who.int/iris/handle/10665/332094. License: CC BY-NC-SA 3.0 IGO
https://apps.who.int/iris/handle/10665/3...
. The WHO currently recommends point-of-care immunochromatographic testing to detect schistosome circulating cathodic antigen in urine as an alternative to the routinely used Kato-Katz (KK) fecal thick smear22. Katz N, Chaves A, Pellegrino J. A simple device for quantitative stool thick-smear technique in Schistosomiasis mansoni. Rev Inst Med Trop Sao Paulo. 1972;14(6):397-400. - two slides from a single stool sample - to establish prevalence thresholds for varying treatment schemes and additional interventions in endemic areas (https://www.who.int/activities/enhancing-implementation-of-schistosomiasis-control-and-elimination-programmes Accessed 19 June, 2021). However, several studies have indicated a lack of reproducibility and the need for extensive and rigorous evaluation in different settings33. Viana AG, Gazzinelli-Guimaraes PH, Castro VN, Santos Y, Ruas ACL, Bezerra FSM, et al. Discrepancy between batches and impact on the sensitivity of point-of-care circulating cathodic antigen tests for Schistosoma mansoni infection. Acta Trop. 2019;197:105049.

4. Colley DG, King CH, Kittur N, Ramzy RMR, Secor WE, Fredericks-James M, et al. Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for Mapping Schistosoma mansoni Infections. Am J Trop Med Hyg. 2020;103(Suppl 1):42-9.
-55. Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863..

One issue in POC-ECO performance evaluation is the manufacturer’s claim that urine samples can be stored at -20° C for one year before testing at room temperature (20-25° C). As pointed out by van der Hel et al.66. van der Hel OL, van der Luijt RB, Bueno de Mesquita HB, van Noord PA, Slothouber B, Roest M, et al. Quality and quantity of DNA isolated from frozen urine in population-based research. Anal Biochem. 2002;304(2):206-11., several population-based studies have collected and stored frozen urine samples, which can subsequently be used in reliable, validated assays. This is especially important given the impact of the COVID-19 pandemic on public health actions against NTDs77. World Health Organization (WHO). Neglected tropical diseases: impact of COVID-19 and WHO’s response. Wkly Epidemiol Rec. 2020;95(‎39):461-8. World Health Organization https://apps.who.int/iris/handle/10665/334562.
https://apps.who.int/iris/handle/10665/3...
, which include delays in diagnostic testing and disruption of periodic treatment in schistosomiasis high transmission areas88. Toor J, Adams ER, Aliee M, Amoah B, Anderson RM, Ayabina D, et al. Predicted Impact of COVID-19 on Neglected Tropical Disease Programs and the Opportunity for Innovation. Clin Infect Dis. 2021;72(8):1463-6.. In Brazil, all 472 priority municipalities that had agreed to intensify schistosomiasis control under the Ministry of Health (MoH) 2019-2022 Action Plan have postponed their actions indefinitely, including treatment of infection carriers identified by single-sample KK in localities at the greatest risk55. Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863..

Stored urine was tested with different batches of POC-ECO distributed in Brazil by Eco Diagnóstica Ltda (http://ecodiagnostica.com.br/diagnostico-rapido/urine-cca-schisto-eco-teste/#detail-product Accessed 19 June, 2021), on the assumption that outcomes would not be significantly different from those obtained with freshly collected urine. Accordingly, Viana et al.33. Viana AG, Gazzinelli-Guimaraes PH, Castro VN, Santos Y, Ruas ACL, Bezerra FSM, et al. Discrepancy between batches and impact on the sensitivity of point-of-care circulating cathodic antigen tests for Schistosoma mansoni infection. Acta Trop. 2019;197:105049. used urine from 64 egg-positive patients that had been frozen at -80°C for an unspecified period. However, they did not report the outcomes of the freshly collected samples. Similarly, Grenfell et al.99. Grenfell RFQ, Pedrosa ML, Couto FFB, Almeida A, Coelho PMZ, Katz N. Suitability of commercially available POC-CCA tests for schistosomiasis: Considerations for efficiency, reproducibility and decision making criteria for field application in areas of low endemicity. J Immunol Methods. 2019;472:1-6. used urine from 27 egg-positive and 21 egg-negative individuals previously stored for two years at -20°C, but no outcomes from freshly collected urine were provided. In contrast, Graeff-Teixeira et al.55. Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863. showed unacceptably low specificity in POC-ECO results from freshly collected urine and one-year stored (-20°C) urine from a non-endemic area.

The present study forms part of a multicenter research project to evaluate the performance of POC-ECO in Brazil’s endemic settings and to produce recommendations for its inclusion in the MoH schistosomiasis elimination action plan. The study was conducted in nine representative localities following the same core protocol. Due to operational issues, the performance of POC-ECO for diagnosing schistosomiasis mansoni in the same urine samples (i) fresh after collection and (ii) frozen at -20°C for one year was evaluated in only one endemic locality, the results of which are presented here.

In Brazil, POC-ECO is commercially available as an Eco-Teste® (ECO Diagnóstica Ltda. Corinto, MG, Brazil), registered (MoH 80954880012), and approved by the Brazilian Health Regulatory Agency (Anvisa) for use as an auxiliary diagnostic tool for patients with clinical signs and symptoms of active infection. However, further performance validation is required for it to be used in surveillance and control actions in endemic areas. POC-ECO will be recommended to the MoH for use with stored urine only if outcomes are both accurate and precise, as described by Viera and Garrett1010. Viera AJ, Garrett JM. Understanding interobserver agreement: the kappa statistic. Fam Med. 2005;37(5):360-3..

METHODS

Study Area and Sampling

This study was conducted in Jaguaritira (17°54’00.0” S; 42°13’58.8” W), a rural district in the municipality of Malacacheta with a population of approximately 900, located in the endemic area of Minas Gerais, Brazil1111. Cabello RKSA, Beck LCNH, Massara CL, Murta FLG, Guimaraes R, Pieri OS, et al. Schistosoma mansoni infection and related knowledge among schoolchildren in an endemic area of Minas Gerais, Brazil, prior to educational actions. Acta Trop . 2016;164:208-15.. The prevalence of schistosomiasis estimated by the KK (single sample, two slides) among schoolchildren (6-15 years-old) was 13% in 20151212. Favre TC, Massara CL, Beck LCNH, Cabello RKSA, Pieri OS. Adherence to diagnosis followed by selective treatment of schistosomiasis mansoni and related knowledge among schoolchildren in an endemic area of Minas Gerais, Brazil, prior to and after the implementation of educational actions. Parasite Epidemiol Control. 2021;13:e00208.. In May-June 2019, all children aged 11-13 years attending the middle years of upper secondary school in Jaguaritira, together with their families, were invited to participate in the multicenter study, the findings of which will be published in good time. All family members over two years old were eligible to participate after signing and/or oral assenting to the Free and Informed Consent Form, which included information that part of the collected material would be stored and could be retested for quality control. Exclusion criteria were self-reported pregnancy, clinical signs or symptoms of acute illness, and severe chronic diseases55. Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863.. Each consenting adult and assenting child was asked to provide approximately 50 g of stool and 10 ml of midstream morning urine, which was stored in a refrigerator at 4°C until the following day. For egg detection, stool samples were assayed using both KK and HTX, the former as a routine test, and the latter as a highly sensitive, robust reference test1313. de Souza RP, Favero V, Pascoal VF, Lindholz C, Bittencourt HR, Graeff-Teixeira C. Criteria for identification of Schistosoma mansoni eggs in faecal sediments prepared with the Helmintex method and stained by ninhydrin. Mem Inst Oswaldo Cruz. 2019;114:e180529.,1414. Favero V, Frasca Candido RR, De Marco Verissimo C, Jones MK, St Pierre TG, Lindholz CG, et al. Optimization of the Helmintex method for schistosomiasis diagnosis. Exp Parasitol. 2017;177:28-34.. The HTX procedure involved the dispersal of 30 g of stool in a Tween-ethanol solution, repeated filtration and sedimentation followed by incubation with paramagnetic particles, separation of S. mansoni eggs with a magnet, and staining of the resulting sediment with ninhydrin. The sediment was then spread over slides of filter papers for examination by optical microscopy. Although laborious and time-consuming, HTX significantly increases egg detection in stool samples from low-intensity transmission areas compared with routine KK1515. Lindholz CG, Favero V, Verissimo CM, Candido RRF, de Souza RP, Dos Santos RR, et al. Study of diagnostic accuracy of Helmintex, Kato-Katz, and POC-CCA methods for diagnosing intestinal schistosomiasis in Candeal, a low intensity transmission area in northeastern Brazil. PLoS Negl Trop Dis. 2018;12(3):e0006274.

16. Magalhaes FDC, Resende SD, Senra C, Graeff-Teixeira C, Enk MJ, Coelho PMZ, et al. Accuracy of real-time polymerase chain reaction to detect Schistosoma mansoni - infected individuals from an endemic area with low parasite loads. Parasitology. 2020;147(10):1140-8.

17. Oliveira WJ, Magalhaes FDC, Elias MAS, de Castro VN, Favero V, Lindholz CG, et al. Evaluation of diagnostic methods for the detection of intestinal schistosomiasis in endemic areas with low parasite loads: Saline gradient, Helmintex, Kato-Katz and rapid urine test. PLoS Negl Trop Dis . 2018;12:e0006232.
-1818. Sousa SEM, Nogueira JFC, Dias IHL, Fonseca ALS, Favero V, Geiger SM, et al. The use of the circulating cathodic antigen (CCA) urine cassette assay for the diagnosis and assessment of cure of Schistosoma mansoni infections in an endemic area of the Amazon region. Rev Soc Bras Med Trop. 2020;53:e20190562..

Freshly collected urine samples were assayed by POC-ECO (batch number: 180907091; expiry date: 30 August, 2020) following the Eco Diagnóstica (ED) instructions for transportation, storage, and use (Edition 001/2018, approved on 12 June, 2018). Two drops of urine were transferred to the well of the testing cassette and a reading was taken in the 21st minute by two experienced technicians blinded to the results of the stool tests. The outcome was scored by grading the POC-ECO test line on a scale of 1 to 10 (G1-G10) and recoding into a visual score as follows: G1, negative; G2-G3, trace; G4-G10, positive1919. Casacuberta-Partal M, Hoekstra PT, Kornelis D, van Lieshout L, van Dam GJ. An innovative and user-friendly scoring system for standardised quantitative interpretation of the urine-based point-of-care strip test (POC-CCA) for the diagnosis of intestinal schistosomiasis: a proof-of-concept study. Acta Trop . 2019;199:105150.. The G-score outcome was unanimously determined by readers. At least 2 ml of each urine sample was stored in a freezer at -20°C to ensure reliability after at least one year. The freezer power supply was backed by a generator to prevent accidental defrosting of the samples, and the temperature was recorded daily with a maximum-minimum thermometer. The 242 fully compliant participants averaged 27 years of age and 7% had more than 100 eggs per gram of stool (epg) as estimated with KK (one sample, two slides). The prevalence of infection was estimated using KK, Helmintex (HTX), and POC-ECO, both with trace outcomes divided into positive (t+) and negative(t-); the values obtained were 20% with KK, 56% with HTX, 77% for POC-ECO t+, and 57% for POC-ECO t-; the prevalence of KK in combination with HTX (KK+HTX) was 58%.

The minimum sample size for evaluating POC-ECO test-retest reliability at one year was calculated as recommended by Bujang and Baharum2020. Bujang MA, Baharum N. Guidelines of the minimum sample size requirements for Cohen’s Kappa. Epidemiol Biostat Public Health. 2017;14:e12267-1.. Landis and Koch2121. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977; 33(1):159-74. and Viera and Garrett1010. Viera AJ, Garrett JM. Understanding interobserver agreement: the kappa statistic. Fam Med. 2005;37(5):360-3. have shown that in order to determine a sample size that differentiates between a Cohen’s kappa coefficient of κ=0.0 (no agreement) and moderate agreement (κ=0.5), at least 38 urine samples were required for a statistical power of 0.9 (90%) and a significance level of 0.05; however, the minimum sample size was multiplied by two (38 × 2 = 76), as recommended by Bujang & Baharum2020. Bujang MA, Baharum N. Guidelines of the minimum sample size requirements for Cohen’s Kappa. Epidemiol Biostat Public Health. 2017;14:e12267-1.. This sample size provided a statistical power of 0.8 (80%) and a p-value of less than 0.05, to differentiate between 50% (null hypothesis) and 80% (minimum acceptable value) sensitivity and specificity for a true prevalence of 60%2222. Bujang MA, Adnan TH. Requirements for Minimum Sample Size for Sensitivity and Specificity Analysis. J Clin Diagn Res. 2016;10(10):YE01-YE06..

Sample Processing and Testing

From 242 urine samples from fully compliant participants stored at -20°C in May-June 2019, seventy-six were randomly selected for retesting in May-June 2020 with POC-ECO (Batch 201907001; expiry date: 30/04/2021). The POC-ECO batch used with freshly collected urine was not used with stored urine because its expiry date (30 August, 2020) was close to the retest period. Both batches were used at approximately half of their shelf lives to avoid stability bias. For retesting, samples were defrosted and homogenized at room temperature (25°C), as recommended by the manufacturer, and assayed by two procedures in parallel. One was identical to that used with freshly collected urine and the other, named POC-ECO/FLT, was a 30-minute procedure that yielded a filtered sample with tenfold concentration for testing99. Grenfell RFQ, Pedrosa ML, Couto FFB, Almeida A, Coelho PMZ, Katz N. Suitability of commercially available POC-CCA tests for schistosomiasis: Considerations for efficiency, reproducibility and decision making criteria for field application in areas of low endemicity. J Immunol Methods. 2019;472:1-6.,2323. Grenfell RFQ, Taboada D, Coutinho LA, Pedrosa MLC, Assis JV, Oliveira MSP, et al. Innovative methodology for point-of-care circulating cathodic antigen with rapid urine concentration for use in the field for detecting low Schistosoma mansoni infection and for control of cure with high accuracy. Trans R Soc Trop Med Hyg. 2018;112(1):1-7.. In this field-friendly method designed to optimize the CCA assay2424. Armoo S, Cunningham LJ, Campbell SJ, Aboagye FT, Boampong FK, Hamidu BA, et al. Detecting Schistosoma mansoni infections among pre-school-aged children in southern Ghana: a diagnostic comparison of urine-CCA, real-time PCR and Kato-Katz assays. BMC Infect Dis. 2020;20:301., each urine sample (0.5 mL) was inserted into a Microcon-30kDa centrifugal filter unit with Ultracel-30 membrane (MRCF0R030, Merck Millipore Ltd., Ireland), centrifuged (GMCLab PMC880 mini centrifuge, Gilson, USA) at 2000 g for 30 min, and re-suspended in 0.05 ml of distilled water to obtain a ten-fold increase in the concentration of the original sample. Two drops (100 µL in total) of the filtered, concentrated sample were then transferred to the well of the POC-ECO testing cassette and read, as described earlier.

Data Analysis

Data were entered into an Excel spreadsheet and transferred to Systat 13 (Systat Software Inc., USA) for statistical analysis. The POC-ECO results (negative/trace/positive) were expressed in absolute numbers and percentages with 95% confidence intervals (CIs), where non-overlapping 95% CIs indicated significant differences (p < 0.05) between percentages. KK was used in combination with HTX (KK+HTX) as the benchmark for infection status (egg-positive/egg-negative) because KK alone is unreliable for this purpose in areas where egg load is low in most infection carriers1515. Lindholz CG, Favero V, Verissimo CM, Candido RRF, de Souza RP, Dos Santos RR, et al. Study of diagnostic accuracy of Helmintex, Kato-Katz, and POC-CCA methods for diagnosing intestinal schistosomiasis in Candeal, a low intensity transmission area in northeastern Brazil. PLoS Negl Trop Dis. 2018;12(3):e0006274.. The following performance parameters were estimated: sensitivity or true-positive rate (probability that the test result was positive among egg-positives), specificity or true-negative rate (probability that the test result was negative among egg-negatives), and accuracy (overall probability that egg-negatives and egg-positives were correctly classified). These three parameters were calculated for both POC-ECO and POC-ECO/FLT, considering traces (G2-G3) as positive (t+) and negative (t-), and for KK using the MedCalc diagnostic test calculator (https://www.medcalc.org/calc/diagnostic_test.php Accessed 19 June, 2021). Agreement between the two POC-ECO tests was estimated using Cohen's kappa (κ) statistic: a κ-value below 0.60 indicated inadequate agreement2525. McHugh ML. Interrater reliability: the kappa statistic. Biochem Med (Zagreb). 2012;22(3):276-82..

Ethical considerations

The multicenter study protocol was approved by the Ethics Committee of the Oswaldo Cruz Institute (CEP-IOC), Fiocruz (CAAE: 82469417.8.0000.5248).

RESULTS

Of the 76 participants who provided stool and urine samples in May-June 2019 and whose urine samples were retested after one year of storage at -20°C, 45 (59%; 95% CI: 45.2%-71.4%) tested positive with KK and HTX combined (KK+HTX). The prevalence of infection estimated using KK and HTX alone was 13.2% (95% CI: 5.5%-24.0%) and 56.6% (95% CI: 42.7%-69.0%), respectively. The prevalence of infection from freshly collected urine was 78.9% (95%CI: 65.9%-88.1%) with POC-ECO t+ and 15.8% (95% CI: 7.4%-27.1%) with POC-ECO t-. After one year of storage at -20°C, the prevalence of infection was 18.4% (95% CI: 9.3%-30.2%) with POC-ECO t+, 4.0% (95% CI: 0.4%-12.0%) with POC-ECO t-, 85.6% (95% CI: 73.4%-93.0%) with POC-ECO/FLT t+, and 35.5% (95% CI: 23.2%-48.6%) with POC-ECO/FLT t-. Of the ten participants who tested positive for KK, two had 108 epg (moderate-intensity infection) and tested positive for POC-ECO from both freshly collected and stored urine. The remaining eight (10.5% 95%CI: 3.5%-21.4%) who tested positive with KK had 1-99 epg (low-intensity infection) and, of these, two tested negative with POC-ECO from freshly collected urine and four tested negative with POC-ECO from stored urine.

Table 1 shows the POC-ECO outcomes from freshly collected and stored urine among egg-positive and egg-negative participants, separately and together. Among the 31 egg-negatives, POC-ECO returned three negative results and 25 traces from freshly collected urine, and 28 negatives and three traces from stored urine. The filtration-concentration method (POC-ECO/FLT) detected three negatives and 17 traces in stored urine among the 31 egg-negatives. Among the 45 egg-positives, POC-ECO identified nine positives and 23 traces from freshly collected urine, and three positives and eight traces from stored urine. POC-ECO/FLT detected 16 positives and 21 traces among the 45 egg positives. The κ-values calculated from the results in Table 1 to estimate agreement between POC-ECO findings from freshly-collected and stored urine in all 76 samples were as follows: 0.08 (95% CI: -0.01- 0.16) if traces are considered positive (t+) and 0.36 (95% CI: 0.06- 0.67) if traces are considered negative (t-).

TABLE 1:
Results of POC-ECO by infection status determined by a robust reference standard (KK+HTX) from freshly-collected urine and urine retested after being stored at -20°C for one year.

Figure 1 depicts the performance of POC-ECO (t+ and t-) with freshly collected and stored urine, POC-ECO/FLT (t+ and t-) with stored urine, and KK (one stool sample, two slides) using KK+HTX as a reference. Sensitivity ranged from a minimum of 6.7% (95%CI: 1.4%-18.3%) for POC-ECO (t-) in stored urine to a maximum of 82.2% (95%CI: 68.0%-92.0%) for POC-ECO/FLT (t+). The urine test sensitivity of POC-ECO (t+) with freshly collected urine and POC-ECO/FLT (t+) was significantly higher than that of KK (22.2%; 95%CI: 11.2%-37.1%), as can be seen from the non-overlapping 95%CIs. Specificity ranged from 9.7% (95%CI: 2.0%-25.8%) with both POC-ECO (t+) in freshly collected urine and POC-ECO/FLT (t+) to 100% (95%CI: 88.8%-100%) with POC-ECO/FLT (t-). Urine test specificity of POC-ECO (t+) with freshly-collected urine and POC-FLT (both t+ and t-) in stored urine was significantly lower than that of KK (100%; 95%CI: 88.8%-100%). Accuracy ranged from 46.1% (95%CI: 34.6%-57.9%) with POC-ECO (t+) in freshly collected urine to 52.6% (95%CI: 40.8%-64.2%) with POC-ECO/FLT (t+) in stored urine. No significant difference (p > 0.05) in accuracy was detected among the urine tests, as the 95% CIs overlapped in all situations, and there was also no significant difference in the accuracy of urine tests compared with KK (54.0%; 95%CI: 42.1%-65.5%).

FIGURE 1:
Performance of Kato-Katz, POC-ECO (batch 180907091) with freshly-collected urine, and both POC-ECO and POC-ECO/FLT (batch 201907001) with urine storePerformance of Kato-Katz, POC-ECO (batch 180907091) with freshly collected urine, and both POC-ECO and POC-ECO/FLT (batch 201907001) with urine stored at -20°C for one year, taking as reference the joint outcome of Kato-Katz and Helmintex® (KK+HTX). Percentage (%) values for sensitivity, specificity, accuracy and 95% Confidence Intervals (CI) are depicted on vertical lines. POC-ECO and POC-ECO/FLT results were calculated considering traces as positive (t+) and as negative (t-).

DISCUSSION

The agreement between POC-ECO results with freshly collected and stored urine (test-retest) was inadequate, with κ-values below 0.602525. McHugh ML. Interrater reliability: the kappa statistic. Biochem Med (Zagreb). 2012;22(3):276-82., regardless of whether traces were considered positive (t+) or negative (t). Among egg-negatives, POC-ECO outcomes in freshly collected urine were mostly trace (25 of 31; 80.6%), whereas in stored urine, POC-ECO outcomes were mainly negative (28 of 31; 90.3%) (Table 1). The poor agreement obtained (κ = 0.08) if trace is considered positive (t+) may be due to the use of batch 180907091 in freshly collected urine, which may yield unduly high levels of trace outcomes regardless of whether they were purchased from the ED or Rapid Medical Diagnostics (RMD), South Africa (Daniel Colley, personal information). However, the weak agreement (κ = 0.36) obtained if the trace is considered negative (t-) may be attributed to the disproportionately high levels of negative outcomes with POC-ECO batch 201907001 in stored urine from egg-positives.

Note also that the POC-ECO/FLT filtration-concentration procedure applied in our study to POC-ECO batch 201907001 in stored urine reduced the negative outcomes by 80.6 percentage points (pp), from 90.3% to 9.7% among egg-negatives, and increased the positive outcomes by 35.5 pp (from 0.0% to 35.5%). Surprisingly, trace outcomes increased by 28.9 pp (from 17.8% to 46.7%) with POC-ECO/FLT among egg-positive patients (Table 1). This contrasts with previous results99. Grenfell RFQ, Pedrosa ML, Couto FFB, Almeida A, Coelho PMZ, Katz N. Suitability of commercially available POC-CCA tests for schistosomiasis: Considerations for efficiency, reproducibility and decision making criteria for field application in areas of low endemicity. J Immunol Methods. 2019;472:1-6. with batch 170522062 (also from the ED) in stored urine, as traces obtained with POC-ECO/FLT in that study were all from egg-negative individuals identified by a robust egg detection method.

The discrepancies found between the POC-ECO/FLT performance in that study and ours may be due to the different amounts of urine that ED required to be dropped on the circular well of the test cassette: ≈150 µL (three drops from the test kit pipette) in the former study and ≈100 µL (two drops from the pipette) in this study. Grenfell et al.99. Grenfell RFQ, Pedrosa ML, Couto FFB, Almeida A, Coelho PMZ, Katz N. Suitability of commercially available POC-CCA tests for schistosomiasis: Considerations for efficiency, reproducibility and decision making criteria for field application in areas of low endemicity. J Immunol Methods. 2019;472:1-6. followed instructions from Edition 002/2017 of the ED leaflet included in the batch 170522062 package, which required “three drops or 100 µl”; this study followed instructions from edition 001/2018 of the ED leaflet included in both the batch 180907091 and batch 201907001 packages, which required “two drops or 100 µl.” ED performs only the final manipulation process, which consist of machine-cutting the reagent-impregnated sheets received from RMD into individual strips, manually inserting the strip into the test cassette and foil-pouching it under rigorous quality control protocol; all prior phases are performed by the technology holder, RDM. Since October 2017, the assay has required two drops of urine and no buffer44. Colley DG, King CH, Kittur N, Ramzy RMR, Secor WE, Fredericks-James M, et al. Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for Mapping Schistosoma mansoni Infections. Am J Trop Med Hyg. 2020;103(Suppl 1):42-9.. However, the ED folder currently available on the Internet wrongly retains the requirement of three drops of urine for POC-ECO testing (http://ecodiagnostica.com.br/wp-content/uploads/2018/04/Folder-Schistosoma.pdf Accessed 19 June, 2021). These POC-ECO quality assurance and quality control issues reinforce previous concerns with Schisto POC-CCA® from Rapid Medical Diagnostics (POC-CCA) both in freshly-collected44. Colley DG, King CH, Kittur N, Ramzy RMR, Secor WE, Fredericks-James M, et al. Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for Mapping Schistosoma mansoni Infections. Am J Trop Med Hyg. 2020;103(Suppl 1):42-9.,2626. Peralta JM, Cavalcanti MG. Is POC-CCA a truly reliable test for schistosomiasis diagnosis in low endemic areas? The trace results controversy. PLoS Negl Trop Dis . 2018;12(11):e0006813. and stored urine33. Viana AG, Gazzinelli-Guimaraes PH, Castro VN, Santos Y, Ruas ACL, Bezerra FSM, et al. Discrepancy between batches and impact on the sensitivity of point-of-care circulating cathodic antigen tests for Schistosoma mansoni infection. Acta Trop. 2019;197:105049.,55. Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863.. Moreover, results from earlier studies based on a discontinued version of POC-CCA requiring one drop of urine and one drop of buffer1616. Magalhaes FDC, Resende SD, Senra C, Graeff-Teixeira C, Enk MJ, Coelho PMZ, et al. Accuracy of real-time polymerase chain reaction to detect Schistosoma mansoni - infected individuals from an endemic area with low parasite loads. Parasitology. 2020;147(10):1140-8.

17. Oliveira WJ, Magalhaes FDC, Elias MAS, de Castro VN, Favero V, Lindholz CG, et al. Evaluation of diagnostic methods for the detection of intestinal schistosomiasis in endemic areas with low parasite loads: Saline gradient, Helmintex, Kato-Katz and rapid urine test. PLoS Negl Trop Dis . 2018;12:e0006232.
-1818. Sousa SEM, Nogueira JFC, Dias IHL, Fonseca ALS, Favero V, Geiger SM, et al. The use of the circulating cathodic antigen (CCA) urine cassette assay for the diagnosis and assessment of cure of Schistosoma mansoni infections in an endemic area of the Amazon region. Rev Soc Bras Med Trop. 2020;53:e20190562.,272 7.Bezerra FSM, Leal JKF, Sousa MS, Pinheiro MCC, Ramos NA, Jr Silva-Moraes V, et al. Evaluating a point-of-care circulating cathodic antigen test (POC-CCA) to detect Schistosoma mansoni infections in a low endemic area in north-eastern Brazil. Acta Trop . 2018;182:264-70.

28. Diab RG, Tolba MM, Ghazala RA, Abu-Sheasha GA, Webster BL, Mady RF. Intestinal schistosomiasis: Can a urine sample decide the infection? Parasitol Int. 2020;80:102201.

29. Ramirez ADP, Favero V, Lindholz CG, Verissimo CM, Pascoal VF, Candido RRF, et al. Schistosomiasis: an epidemiological update on Brazil's southernmost low endemic area in Esteio. Rev Soc Bras Med Trop . 2020;53:e20200411.

30. Ruberanziza E, Wittmann U, Mbituyumuremyi A, Mutabazi A, Campbell CH, Colley DG, et al. Nationwide Remapping of Schistosoma mansoni Infection in Rwanda Using Circulating Cathodic Antigen Rapid Test: Taking Steps toward Elimination. Am J Trop Med Hyg . 2020;103(1):315-24.

31. Sassa M, Chadeka EA, Cheruiyot VB, Tanaka M, Moriyasu T, Kaneko S, et al. Prevalence and risk factors of Schistosoma mansoni infection among children under two years of age in Mbita, Western Kenya. PLoS Negl Trop Dis . 2020;14(8):e0008473.
-3232. Siqueira LM, Couto FF, Taboada D, Oliveira AA, Carneiro NF, Oliveira E, et al. Performance of POC-CCA(R) in diagnosis of schistosomiasis mansoni in individuals with low parasite burden. Rev Soc Bras Med Trop . 2016;49(3):341-7. may not be comparable with those based on the new version of POC-CCA requiring two drops of urine and no buffer33. Viana AG, Gazzinelli-Guimaraes PH, Castro VN, Santos Y, Ruas ACL, Bezerra FSM, et al. Discrepancy between batches and impact on the sensitivity of point-of-care circulating cathodic antigen tests for Schistosoma mansoni infection. Acta Trop. 2019;197:105049.,44. Colley DG, King CH, Kittur N, Ramzy RMR, Secor WE, Fredericks-James M, et al. Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for Mapping Schistosoma mansoni Infections. Am J Trop Med Hyg. 2020;103(Suppl 1):42-9.,2424. Armoo S, Cunningham LJ, Campbell SJ, Aboagye FT, Boampong FK, Hamidu BA, et al. Detecting Schistosoma mansoni infections among pre-school-aged children in southern Ghana: a diagnostic comparison of urine-CCA, real-time PCR and Kato-Katz assays. BMC Infect Dis. 2020;20:301.,3333. Haggag AA, Rabiee A, Abd Elaziz KM, Campbell CH, Colley DG, Ramzy RMR. Thirty-Day Daily Comparisons of Kato-Katz and CCA Assays of 45 Egyptian Children in Areas with Very Low Prevalence of Schistosoma mansoni. Am J Trop Med Hyg . 2019;100(3):578-83.

34. Bezerra DF, Pinheiro MCC, Barbosa L, Viana AG, Fujiwara RT, Bezerra FSM. Diagnostic comparison of stool exam and point-of-care circulating cathodic antigen (POC-CCA) test for schistosomiasis mansoni diagnosis in a high endemicity area in northeastern Brazil. Parasitology. 2021;148(4):420-6.
-3535. Okoyo C, Simiyu E, Njenga SM, Mwandawiro C. Comparing the performance of circulating cathodic antigen and Kato-Katz techniques in evaluating Schistosoma mansoni infection in areas with low prevalence in selected counties of Kenya: a cross-sectional study. BMC Public Health. 2018;18(1):478..

POC-ECO accuracy, that is, the overall probability that egg-negative and egg-positive individuals are correctly classified, was no better than routine KK (one stool sample, two slides), as evaluated by a robust reference standard (KK+HTX) based on egg detection. This disappointing result occurred with both freshly collected and stored urine, regardless of whether traces were considered positive or negative (Figure 1). Note that the filtration-concentration procedure (POC-ECO/FLT) did not improve the accuracy of stored urine with either t+ or t-. However, this is not unexpected because the improvement in POC-ECO/FLT is designed to yield benefits in low-infection settings and post-treatment situations99. Grenfell RFQ, Pedrosa ML, Couto FFB, Almeida A, Coelho PMZ, Katz N. Suitability of commercially available POC-CCA tests for schistosomiasis: Considerations for efficiency, reproducibility and decision making criteria for field application in areas of low endemicity. J Immunol Methods. 2019;472:1-6.,2323. Grenfell RFQ, Taboada D, Coutinho LA, Pedrosa MLC, Assis JV, Oliveira MSP, et al. Innovative methodology for point-of-care circulating cathodic antigen with rapid urine concentration for use in the field for detecting low Schistosoma mansoni infection and for control of cure with high accuracy. Trans R Soc Trop Med Hyg. 2018;112(1):1-7..

The main limitation of the present study was that it did not include a direct comparison between the two POC-ECO batches at test and retest, to account for both batch-to-batch variation and the effect of urine storage. The current Eco Diagnóstica pamphlet on POC-ECO (http://ecodiagnostica.com.br/wp-content/uploads/2016/09/Bula-Urine-CCA-Schisto-1.pdf) states that “urine samples can be stored at -20°C for one year”, but provides no evidence or reference to support this claim. As the present study showed a significant difference between POC-ECO performance at test and retest, confirming previous findings from a non-endemic area55. Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863., the manufacturer should withdraw this currently unsupported claim from the pamphlet. Additional work is required to assess the effect of urine storage and to optimize POC-ECO precision and accuracy before making claims for its use with long-term stored urine.

A recently published study3636. Mewamba EM, Tiofack AAZ, Kamdem CN, Ngassam RIK, Mbagnia MCT, Nyangiri O, et al. Field assessment in Cameroon of a reader of POC-CCA lateral flow strips for the quantification of Schistosoma mansoni circulating cathodic antigen in urine. PLoS Negl Trop Dis . 2021;15(7):e0009569. using the same batch of POC-CCA both in fresh and frozen urine (-20°C) after one year found a significant decrease in the positive rate, from 100% (95%CI: 98.0%-100.0%) to 74.4% (95%CI: 66.9%-80.7%), considering trace as positive (t+). This was ascribed to the degradation of CCA, which might have occurred because the study area was susceptible to recurrent power failure, leading to undue thawing of the urine samples. In the present study, however, the possibility of accidental freeze-thaw cycles of the samples could be ruled out due to the use of a power generator, ensuring daily minimum and maximum temperatures of approximately -20°C.

To our knowledge, no previous study in moderately endemic areas has compared the accuracy of recent POC-ECO batches (two urine drops and no buffer) with that of routine KK (one stool sample and two slides) using a robust egg-detection method as a reference. It should be emphasized that diagnostic accuracy is a prevalence-dependent parameter3737. Mandrekar JN. Simple statistical measures for diagnostic accuracy assessment. J Thorac Oncol. 2010;5(6):763-4.; therefore, the values obtained in areas with different endemicities may not be comparable. Moreover, it is recommended that “true” prevalence be estimated using robust reference methods to provide a better reflection of the true disease status in the target population. As part of a multicenter study, the accuracy of the POC-ECO assay for diagnosing schistosomiasis mansoni is being evaluated in areas of different endemicities using the same POC-ECO batch and the same robust reference method. As pointed out by Graeff-Teixeira et al.55. Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863., rigorous diagnostic tests based on egg detection from larger amounts of fecal material or increased sampling are meant for reference purposes, and not for use in routine control programs. Thus, a highly accurate, urine-based schistosomiasis rapid diagnostic method would be more cost-effective than labor - and time-intensive stool microscopy, particularly in endemic settings with limited resources.

CONCLUSION

This study showed that the POC-ECO assay is not reliable for diagnosing schistosomiasis mansoni in urine stored at -20°C for one year, given the inconsistencies found in its performance. Before much work can be done to clarify the precision and accuracy of POC-ECO in both freshly collected and stored urine, manufacturers must optimize the quality assurance and quality control measures.

ACKNOWLEDGMENTS

The authors wish to thank Dr Bárbara P. Gaspar for medical supervision; Marielly Gonçalves Abrantes and Wilson da Silva Guimarães for technical support; Ana Paula Pereira da Silva and Maira Daniane Gomes, Community Health Agents, for support in the collection of samples; the health and education staff of Malacacheta municipality for providing facilities; Dr Jeann Marie da Rocha Marcelino and Dr Rosa Castália França Ribeiro Soares at the Ministry of Health for invaluable leadership; the Oswaldo Cruz Institute for administering the study. Thanks are due to Prof Govert J. van Dam, Leiden University Medical Centre, for providing the POC-CCA reference cassettes. Special thanks go to the school directors, teachers, schoolchildren, and families of Jaguaritira.

REFERENCES

  • 1
    World Health Organization (WHO). Ending the neglect to attain the sustainable development goals: a road map for neglected tropical diseases 2021-2030. WHO. 2020. https://apps.who.int/iris/handle/10665/332094 License: CC BY-NC-SA 3.0 IGO
    » https://apps.who.int/iris/handle/10665/332094
  • 2
    Katz N, Chaves A, Pellegrino J. A simple device for quantitative stool thick-smear technique in Schistosomiasis mansoni. Rev Inst Med Trop Sao Paulo. 1972;14(6):397-400.
  • 3
    Viana AG, Gazzinelli-Guimaraes PH, Castro VN, Santos Y, Ruas ACL, Bezerra FSM, et al. Discrepancy between batches and impact on the sensitivity of point-of-care circulating cathodic antigen tests for Schistosoma mansoni infection. Acta Trop. 2019;197:105049.
  • 4
    Colley DG, King CH, Kittur N, Ramzy RMR, Secor WE, Fredericks-James M, et al. Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for Mapping Schistosoma mansoni Infections. Am J Trop Med Hyg. 2020;103(Suppl 1):42-9.
  • 5
    Graeff-Teixeira C, Favero V, Pascoal VF, de Souza RP, Rigo FV, Dall Agnese LH, et al. Low specificity of point-of-care circulating cathodic antigen (POC-CCA) diagnostic test in a non-endemic area for schistosomiasis mansoni in Brazil. Acta Trop . 2021;217:105863.
  • 6
    van der Hel OL, van der Luijt RB, Bueno de Mesquita HB, van Noord PA, Slothouber B, Roest M, et al. Quality and quantity of DNA isolated from frozen urine in population-based research. Anal Biochem. 2002;304(2):206-11.
  • 7
    World Health Organization (WHO). Neglected tropical diseases: impact of COVID-19 and WHO’s response. Wkly Epidemiol Rec. 2020;95(‎39):461-8. World Health Organization https://apps.who.int/iris/handle/10665/334562
    » https://apps.who.int/iris/handle/10665/334562
  • 8
    Toor J, Adams ER, Aliee M, Amoah B, Anderson RM, Ayabina D, et al. Predicted Impact of COVID-19 on Neglected Tropical Disease Programs and the Opportunity for Innovation. Clin Infect Dis. 2021;72(8):1463-6.
  • 9
    Grenfell RFQ, Pedrosa ML, Couto FFB, Almeida A, Coelho PMZ, Katz N. Suitability of commercially available POC-CCA tests for schistosomiasis: Considerations for efficiency, reproducibility and decision making criteria for field application in areas of low endemicity. J Immunol Methods. 2019;472:1-6.
  • 10
    Viera AJ, Garrett JM. Understanding interobserver agreement: the kappa statistic. Fam Med. 2005;37(5):360-3.
  • 11
    Cabello RKSA, Beck LCNH, Massara CL, Murta FLG, Guimaraes R, Pieri OS, et al. Schistosoma mansoni infection and related knowledge among schoolchildren in an endemic area of Minas Gerais, Brazil, prior to educational actions. Acta Trop . 2016;164:208-15.
  • 12
    Favre TC, Massara CL, Beck LCNH, Cabello RKSA, Pieri OS. Adherence to diagnosis followed by selective treatment of schistosomiasis mansoni and related knowledge among schoolchildren in an endemic area of Minas Gerais, Brazil, prior to and after the implementation of educational actions. Parasite Epidemiol Control. 2021;13:e00208.
  • 13
    de Souza RP, Favero V, Pascoal VF, Lindholz C, Bittencourt HR, Graeff-Teixeira C. Criteria for identification of Schistosoma mansoni eggs in faecal sediments prepared with the Helmintex method and stained by ninhydrin. Mem Inst Oswaldo Cruz. 2019;114:e180529.
  • 14
    Favero V, Frasca Candido RR, De Marco Verissimo C, Jones MK, St Pierre TG, Lindholz CG, et al. Optimization of the Helmintex method for schistosomiasis diagnosis. Exp Parasitol. 2017;177:28-34.
  • 15
    Lindholz CG, Favero V, Verissimo CM, Candido RRF, de Souza RP, Dos Santos RR, et al. Study of diagnostic accuracy of Helmintex, Kato-Katz, and POC-CCA methods for diagnosing intestinal schistosomiasis in Candeal, a low intensity transmission area in northeastern Brazil. PLoS Negl Trop Dis. 2018;12(3):e0006274.
  • 16
    Magalhaes FDC, Resende SD, Senra C, Graeff-Teixeira C, Enk MJ, Coelho PMZ, et al. Accuracy of real-time polymerase chain reaction to detect Schistosoma mansoni - infected individuals from an endemic area with low parasite loads. Parasitology. 2020;147(10):1140-8.
  • 17
    Oliveira WJ, Magalhaes FDC, Elias MAS, de Castro VN, Favero V, Lindholz CG, et al. Evaluation of diagnostic methods for the detection of intestinal schistosomiasis in endemic areas with low parasite loads: Saline gradient, Helmintex, Kato-Katz and rapid urine test. PLoS Negl Trop Dis . 2018;12:e0006232.
  • 18
    Sousa SEM, Nogueira JFC, Dias IHL, Fonseca ALS, Favero V, Geiger SM, et al. The use of the circulating cathodic antigen (CCA) urine cassette assay for the diagnosis and assessment of cure of Schistosoma mansoni infections in an endemic area of the Amazon region. Rev Soc Bras Med Trop. 2020;53:e20190562.
  • 19
    Casacuberta-Partal M, Hoekstra PT, Kornelis D, van Lieshout L, van Dam GJ. An innovative and user-friendly scoring system for standardised quantitative interpretation of the urine-based point-of-care strip test (POC-CCA) for the diagnosis of intestinal schistosomiasis: a proof-of-concept study. Acta Trop . 2019;199:105150.
  • 20
    Bujang MA, Baharum N. Guidelines of the minimum sample size requirements for Cohen’s Kappa. Epidemiol Biostat Public Health. 2017;14:e12267-1.
  • 21
    Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977; 33(1):159-74.
  • 22
    Bujang MA, Adnan TH. Requirements for Minimum Sample Size for Sensitivity and Specificity Analysis. J Clin Diagn Res. 2016;10(10):YE01-YE06.
  • 23
    Grenfell RFQ, Taboada D, Coutinho LA, Pedrosa MLC, Assis JV, Oliveira MSP, et al. Innovative methodology for point-of-care circulating cathodic antigen with rapid urine concentration for use in the field for detecting low Schistosoma mansoni infection and for control of cure with high accuracy. Trans R Soc Trop Med Hyg. 2018;112(1):1-7.
  • 24
    Armoo S, Cunningham LJ, Campbell SJ, Aboagye FT, Boampong FK, Hamidu BA, et al. Detecting Schistosoma mansoni infections among pre-school-aged children in southern Ghana: a diagnostic comparison of urine-CCA, real-time PCR and Kato-Katz assays. BMC Infect Dis. 2020;20:301.
  • 25
    McHugh ML. Interrater reliability: the kappa statistic. Biochem Med (Zagreb). 2012;22(3):276-82.
  • 26
    Peralta JM, Cavalcanti MG. Is POC-CCA a truly reliable test for schistosomiasis diagnosis in low endemic areas? The trace results controversy. PLoS Negl Trop Dis . 2018;12(11):e0006813.
  • 2
    7.Bezerra FSM, Leal JKF, Sousa MS, Pinheiro MCC, Ramos NA, Jr Silva-Moraes V, et al. Evaluating a point-of-care circulating cathodic antigen test (POC-CCA) to detect Schistosoma mansoni infections in a low endemic area in north-eastern Brazil. Acta Trop . 2018;182:264-70.
  • 28
    Diab RG, Tolba MM, Ghazala RA, Abu-Sheasha GA, Webster BL, Mady RF. Intestinal schistosomiasis: Can a urine sample decide the infection? Parasitol Int. 2020;80:102201.
  • 29
    Ramirez ADP, Favero V, Lindholz CG, Verissimo CM, Pascoal VF, Candido RRF, et al. Schistosomiasis: an epidemiological update on Brazil's southernmost low endemic area in Esteio. Rev Soc Bras Med Trop . 2020;53:e20200411.
  • 30
    Ruberanziza E, Wittmann U, Mbituyumuremyi A, Mutabazi A, Campbell CH, Colley DG, et al. Nationwide Remapping of Schistosoma mansoni Infection in Rwanda Using Circulating Cathodic Antigen Rapid Test: Taking Steps toward Elimination. Am J Trop Med Hyg . 2020;103(1):315-24.
  • 31
    Sassa M, Chadeka EA, Cheruiyot VB, Tanaka M, Moriyasu T, Kaneko S, et al. Prevalence and risk factors of Schistosoma mansoni infection among children under two years of age in Mbita, Western Kenya. PLoS Negl Trop Dis . 2020;14(8):e0008473.
  • 32
    Siqueira LM, Couto FF, Taboada D, Oliveira AA, Carneiro NF, Oliveira E, et al. Performance of POC-CCA(R) in diagnosis of schistosomiasis mansoni in individuals with low parasite burden. Rev Soc Bras Med Trop . 2016;49(3):341-7.
  • 33
    Haggag AA, Rabiee A, Abd Elaziz KM, Campbell CH, Colley DG, Ramzy RMR. Thirty-Day Daily Comparisons of Kato-Katz and CCA Assays of 45 Egyptian Children in Areas with Very Low Prevalence of Schistosoma mansoni Am J Trop Med Hyg . 2019;100(3):578-83.
  • 34
    Bezerra DF, Pinheiro MCC, Barbosa L, Viana AG, Fujiwara RT, Bezerra FSM. Diagnostic comparison of stool exam and point-of-care circulating cathodic antigen (POC-CCA) test for schistosomiasis mansoni diagnosis in a high endemicity area in northeastern Brazil. Parasitology. 2021;148(4):420-6.
  • 35
    Okoyo C, Simiyu E, Njenga SM, Mwandawiro C. Comparing the performance of circulating cathodic antigen and Kato-Katz techniques in evaluating Schistosoma mansoni infection in areas with low prevalence in selected counties of Kenya: a cross-sectional study. BMC Public Health. 2018;18(1):478.
  • 36
    Mewamba EM, Tiofack AAZ, Kamdem CN, Ngassam RIK, Mbagnia MCT, Nyangiri O, et al. Field assessment in Cameroon of a reader of POC-CCA lateral flow strips for the quantification of Schistosoma mansoni circulating cathodic antigen in urine. PLoS Negl Trop Dis . 2021;15(7):e0009569.
  • 37
    Mandrekar JN. Simple statistical measures for diagnostic accuracy assessment. J Thorac Oncol. 2010;5(6):763-4.
  • Financial Support: This work was funded by the Secretaria de Vigilância em Saúde / Fundo Nacional de Saúde / Ministério da Saúde - [TED/FNS: 118/2017; SIAFI: 691919 / 25000.479741/2017-05].

Publication Dates

  • Publication in this collection
    25 Feb 2022
  • Date of issue
    2022

History

  • Received
    06 July 2021
  • Accepted
    24 Nov 2021
Sociedade Brasileira de Medicina Tropical - SBMT Caixa Postal 118, 38001-970 Uberaba MG Brazil, Tel.: +55 34 3318-5255 / +55 34 3318-5636/ +55 34 3318-5287, http://rsbmt.org.br/ - Uberaba - MG - Brazil
E-mail: rsbmt@uftm.edu.br