Acessibilidade / Reportar erro

Quadricuspid aortic valve by transthoracic echocardiography

Abstracts

A 55-year-old woman seeks medical attention with palpitations, atypical chest pain and dyspnea upon exertion, lasting for 12 months. ECG showed left ventricular hypertrophy. Transthoracic Doppler echocardiogram confirmed hypertrophy of the left chambers and showed a quadricuspid aortic valve, with equal-sized cusps, in addition to a moderate regurgitant central flow. Upon echocardiography, the quadricuspid valve is identified by its characteristic "X" form during diastole and rectangular aspect during systole. Heart failure symptoms are presumably caused by valve insufficiency due to abnormal leaflet coaptation. Considering the possibility of progressive regurgitation, follow up on the patient was performed with periodic echocardiographic control. Symptoms responded to treatment.

Aortic valve; aortic valve insufficiency; echocardiography


Uma mulher de 55 anos procurou atendimento médico com queixas de palpitações, dor torácica atípica e dispnéia ao esforço, com duração de 12 meses. O eletrocardiograma revelou hipertrofia ventricular esquerda. O ecocardiograma Doppler transtorácico confirmou hipertrofia de câmaras esquerdas e detectou a presença de valva aórtica quadri, com válvulas de mesmo tamanho, e fluxo regurgitante central moderado. No ecocardiograma, a valva quadrivalvular é identificada por sua forma característica em "X" durante a diástole e aspecto retangular durante a sístole. Os sintomas de insuficiência cardíaca provavelmente são causados por insuficiência valvar, em decorrência de coaptação anormal das válvulas. Em vista da possibilidade de aumento da regurgitação, a paciente foi submetida a controle ecocardiográfico periódico. Observou-se melhora dos sintomas com o tratamento.

Valva aórtica; insuficiência da valva aórtica; ecocardiografia


CASE REPORT


Quadricuspid aortic valve by transthoracic echocardiography

Erlon Oliveira de Abreu SilvaI; Alessandro Giralde IglesiasII; Erlon de Abreu SilvaII

IComplexo Hospitalar Santa Casa de Porto Alegre, Porto Alegre, RS, Lages, SC - Brazil

IICentro de Diagnóstico Cardiológico, Porto Alegre, RS, Lages, SC - Brazil

Mailing address

ABSTRACT

A 55-year-old woman seeks medical attention with palpitations, atypical chest pain and dyspnea upon exertion, lasting for 12 months. ECG showed left ventricular hypertrophy.

Transthoracic Doppler echocardiogram confirmed hypertrophy of the left chambers and showed a quadricuspid aortic valve, with equal-sized cusps, in addition to a moderate regurgitant central flow.

Upon echocardiography, the quadricuspid valve is identified by its characteristic "X" form during diastole and rectangular aspect during systole. Heart failure symptoms are presumably caused by valve insufficiency due to abnormal leaflet coaptation.

Considering the possibility of progressive regurgitation, follow up on the patient was performed with periodic echocardiographic control. Symptoms responded to treatment.

Key words: Aortic valve / abnormalities; aortic valve insufficiency; echocardiography.

Introduction

Quadricuspid aortic valve is a rare finding, with an incidence varying between 0.008 and 0.033%1, and, in general, is not associated with other conditions. The first related cases were based on necropsy, aortographic or perioperative findings2.

More recently, echocardiography, especially with Doppler, has facilitated early diagnosis of four-cusp aortic valves, evaluation of their function and follow-up.

Our purpose is to report the incidental finding of a quadricuspid aortic valve by transthoracic Doppler echocardiography in a case of valve regurgitation.

Case Report

A 55-year-old woman seeks medical attention with palpitations, atypical chest pain and dyspnea upon exertion, for the 12 previous months. There is no prior history of rheumatic fever, hypertension or other comorbidities. Upon examination, heart rate was 84, blood pressure 130x80mmHg, and there was a diastolic murmur at the aortic position (3+/6+). Chest radiograph revealed augmented cardiac area and the 12-lead ECG showed left ventricular hypertrophy.

Transthoracic echocardiogram revealed moderate left ventricular enlargement and preserved ejection fraction. The mitral valve had a minimum prolapse of the anterior leaflet, with no dysfunction. Tricuspid and pulmonary valves were normal. The aortic valve had four equal-sized cusps (Figures 1), and a moderate regurgitant central flow on Doppler (Figure 2).



Clinical follow-up was indicated with periodic echocardiographic control. Symptoms responded to beta-blocker therapy.

Discussion

Semilunar valve alterations are among the most common cardiac malformations. In contrast to bicuspid aortic valve - present in 2% of population - the finding of a quadricuspid aortic valve is extremely rare, with an incidence between 0.008 and 0.033%1, 3, 4.

The first report of a quadricuspid aortic valve, in 1862, comes from necropsy data; and the first echocardiographic finding is from 19843. Since then, the frequency of this diagnosis has been increasing.

Normally, it presents itself as an isolated condition but may be associated with interventricular septum defect, patent ductus arteriosus, coronary ostium alterations and other valvular defects as well1, 4.

Aortic regurgitation, caused by abnormal leaflet coaptation, is common. Some authors suggest fibrous thickening1,4, while others propose unequal distribution of transvalvar stress - because of the fourth cusp1 -, as the pathophysiological mechanism for valvular insufficiency. Stenosis is rare.

On echocardiography, the quadricuspid valve is identified by its characteristic "X" configuration during diastole (different from the "Y" of normal tricuspid aortic valve) and rectangular aspect during systole1,3,4. According to the Hurwitz and Roberts'5 classification, considering the size of leaflets, only 12% of quadricuspid aortic valves have four equal-sized leaflets.

There is no agreement about which, transthoracic or transesophageal, is the best echocardiographic technique for this diagnosis. However, it is known that the use of Doppler has made the examination more sensitive in demonstrating the retrograde flow through the valve, even when there is no clinical repercussion, facilitating early diagnosis of aortic regurgitation.

Taking into account the technological development of echocardiographic equipment, and its availability as a non-invasive diagnostic tool, it is feasible to detect, follow and diagnose possible complications of quadricuspid aortic valves even in asymptomatic individuals.

Potential Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Sources of Funding

There were no external funding sources for this study.

Study Association

This study is not associated with any graduation program.

References

  • 1- Feldman BJ, Khanderia BK, Warnes CA, Seward JB, Taylor CL, Tajik AJ. Incidence, description and functional assessment of isolated quadricuspid aortic valves. Am J Cardiol. 1990; 65: 937-8.
  • 2- Robicsek F, Sanger PW, Daugherty HK, Montgomery CC. Congenital quadricuspid aortic valve with displacement of the left coronary orifice. Coll Works Cardiopulm Dis. 1968; 14: 87-90.
  • 3- Charandrasekaran K, Tajik AJ, Edwards WD, Seward JB. Two-dimensional echocardiografic diagnosis of quadricuspid aortic valve. Am J Cardiol. 1984; 53: 1732-3.
  • 4- Barbosa MM, Motta MS. Quadricuspid aortic valve and aortic regurgitation diagnosed by Doppler echocardiography: report of two cases and review of the literature. J Am Soc Echocardiogr. 1991; 4: 69-74.
  • 5- Hurwitz LE, Roberts WC. Quadricuspid semilunar valve. Am J Cardiol. 1973; 31: 623-6.
  • Correspondência:
    Erlon Oliveira de Abreu Silva
    Rua Casemiro de Abreu, 725/302, Rio Branco
    90420-001, Porto Alegre, RS - Brasil
    E-mail:
  • Publication Dates

    • Publication in this collection
      11 Aug 2008
    • Date of issue
      Aug 2008

    History

    • Reviewed
      05 Sept 2007
    • Received
      07 Aug 2007
    • Accepted
      26 Sept 2007
    Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
    E-mail: revista@cardiol.br