Postoperative outcome of patients with prosthetic valve leak

Abstracts

BACKGROUND: Prosthetic valve leak is a possible complication of surgical valve replacement. Although uncommon, its consequences may be serious. Few studies correlate the degree of prosthetic valve leak with clinical events. OBJECTIVE: To compare the postoperative outcome of patients with mild/moderate (Mi/Mo) or severe (Sev) prosthetic valve leak METHODS: A total of 185 patients with prosthetic valve leak were selected among 1350 patients undergoing heart valve surgery between 1999 and 2001. Of these, a sample of 58 patients (37 men) with prosthetic valve leak (36 with Mi/Mo versus 22 with Sev leak) in the pre and/or postoperative period of heart valve replacement had complete medical record data, so their clinical, laboratory and echocardiographic data could be retrospectively assessed. RESULTS: The incidence of reoperation was 11.1% in the Mi/Mo group, versus 22.7% in the Sev group (odds ratio = 2.35 [95% CI 0.56-9.94]). Endocarditis was the cause of reoperation in 75% of the patients of the Mi/Mo group and in 60% of the Sev group. Aortic bioprostheses were those most frequently related to leak (55.8% in the Mi/Mo group and 57.7% in the Sev group). Forty percent of the patients with previous Mi/Mo leak did not present prosthetic valve leak on postoperative day 2 versus 21.4% of the patients with Sev prosthetic valve leak. No significant differences were found regarding laboratory variables. CONCLUSIONS: (1) Patients with severe leak are more likely to undergo reoperation. (2) Endocarditis was the most frequent cause of reoperation for any leak degree. (3) Severe prosthetic valve leak is more difficult to fully resolve after surgical treatment.

Heart valve prosthesis; cardiac surgical procedures; endocarditis


FUNDAMENTO: O refluxo de prótese valvar é uma possível complicação da cirurgia de troca valvar. Embora raro, suas consequências podem ser graves. Há poucos estudos que correlacionam o grau do refluxo de prótese valvar com os eventos clínicos dos pacientes. OBJETIVO: Comparar a evolução pós-operatória de pacientes com refluxo de prótese valvar discreto/moderado (D/M) ou importante (Imp). MÉTODOS: Dentre 1.350 pacientes submetidos a cirurgia valvar entre 1999 e 2001, foram selecionados 185 pacientes com refluxo de prótese valvar. Desses pacientes, foram avaliados retrospectivamente dados clínicos, laboratoriais e ecocardiográficos de uma amostra de 58 pacientes (37 homens) com refluxo de prótese valvar no pré e/ou no pós-operatório de troca valvar com dados completos em prontuários, sendo 36 com refluxo D/M versus 22 com refluxo Imp. RESULTADOS: A incidência de reoperação foi de 11,1% no Grupo D/M versus 22,7% no Grupo Imp (odds ratio = 2,35 [IC95% 0,56-9,94]). Endocardite foi a causa de reoperação em 75% dos pacientes do Grupo D/M e em 60% do Grupo Imp. As biopróteses aórticas foram as mais acometidas por refluxo (55,8% no Grupo D/M e 57,7% no Grupo Imp). Evoluíram sem refluxo de prótese valvar no segundo pós-operatório 40% dos pacientes com refluxo prévio D/M versus 21,4% dos pacientes com refluxo de prótese valvar Imp. Não houve diferenças significantes nas variáveis laboratoriais. CONCLUSÕES: (1) Os portadores de refluxo importante têm maior probabilidade de reoperação. (2) Endocardite foi a causa mais frequente de reoperação para qualquer grau de refluxo. (3) O refluxo de prótese valvar importante é de mais difícil resolução completa após tratamento cirúrgico.

Próteses valvulares cardíacas; procedimentos cirúrgicos cardíacos; endocardite


FUNDAMENTO: El reflujo de prótesis valvular es una posible complicación de la cirugía de reemplazo valvular. Aunque raras, sus consecuencias pueden resultar severas. Hay pocos estudios que correlacionan el grado del reflujo de prótesis valvular con los eventos clínicos de los pacientes. OBJETIVO: Comparar la evolución postoperatoria de pacientes con reflujo de prótesis valvular leve/moderado (L/M) o severo (S). MÉTODOS: Teniendo en cuenta a los 1.350 pacientes sometidos a la cirugía valvular entre el 1999 y el 2001, se seleccionaron a 185 pacientes con reflujo de prótesis valvular. De ellos, se evaluaron retrospectivamente datos clínicos, laboratoriales y ecocardiográficos de una muestra de 58 pacientes (37 varones) con reflujo de prótesis valvular en el pre y/o en el postoperatorio de reemplazo valvular con datos completos en prontuarios, con 36 presentado reflujo L/M versus 22 con reflujo S. RESULTADOS: La incidencia de reoperación fue del 11,1% en el Grupo L/M versus el 22,7% en el Grupo S (odds ratio = 2,35 [IC95% 0,56-9,94]). La Endocarditis fue la causa de reoperación en el 75% de los pacientes del Grupo L/M y en el 60% del Grupo S. Las bioprótesis aórticas fueron las más afectadas por reflujo (el 55,8% en el Grupo L/M y el 57,7% en el Grupo S). Evolucionaron sin reflujo de prótesis valvular en el segundo postoperatorio el 40% de los pacientes con reflujo previo L/M versus el 21,4% de los pacientes con reflujo de prótesis valvular S. No hubo diferencia significantes en las variables laboratoriales. CONCLUSIÓN: 1) Los portadores de reflujo severo tienen mayor probabilidad de reoperación. 2) Endocarditis fue la causa más frecuente de reoperación para cualquier grado de reflujo. 3) El reflujo de prótesis valvular severo es de más difícil resolución completa tras tratamiento quirúrgico.

Prótesis valvulares cardíacas; procedimientos quirúrgicos cardiacos; endocarditis


ORIGINAL ARTICLE

Postoperative outcome of patients with prosthetic valve leak

Roney Orismar SampaioI; Francisco Costa da Silva Jr.I; Iraí Santana de OliveiraI; Celso Madeira PadovesiII; Joyce Aparecida SoaresII; William Manoel da SilvaII; Luciana de Paula SamoranoI; Flávio TarasoutchiI; Guilherme Sobreira SpinaI; Max GrinbergI

IInstituto do Coração do Hospital das Clínicas da Universidade de São Paulo – InCor, São Paulo

IIFaculdade de Medicina de Marília – FAMEMA, Marília, SP, Brasil

Mailing address

SUMMARY

BACKGROUND: Prosthetic valve leak is a possible complication of surgical valve replacement. Although uncommon, its consequences may be serious. Few studies correlate the degree of prosthetic valve leak with clinical events.

OBJECTIVE: To compare the postoperative outcome of patients with mild/moderate (Mi/Mo) or severe (Sev) prosthetic valve leak

METHODS: A total of 185 patients with prosthetic valve leak were selected among 1350 patients undergoing heart valve surgery between 1999 and 2001. Of these, a sample of 58 patients (37 men) with prosthetic valve leak (36 with Mi/Mo versus 22 with Sev leak) in the pre and/or postoperative period of heart valve replacement had complete medical record data, so their clinical, laboratory and echocardiographic data could be retrospectively assessed.

RESULTS: The incidence of reoperation was 11.1% in the Mi/Mo group, versus 22.7% in the Sev group (odds ratio = 2.35 [95% CI 0.56-9.94]). Endocarditis was the cause of reoperation in 75% of the patients of the Mi/Mo group and in 60% of the Sev group. Aortic bioprostheses were those most frequently related to leak (55.8% in the Mi/Mo group and 57.7% in the Sev group). Forty percent of the patients with previous Mi/Mo leak did not present prosthetic valve leak on postoperative day 2 versus 21.4% of the patients with Sev prosthetic valve leak. No significant differences were found regarding laboratory variables.

CONCLUSIONS: (1) Patients with severe leak are more likely to undergo reoperation. (2) Endocarditis was the most frequent cause of reoperation for any leak degree. (3) Severe prosthetic valve leak is more difficult to fully resolve after surgical treatment.

Key words: Heart valve prosthesis; cardiac surgical procedures; endocarditis.

Introduction

Prosthetic valve leak is a relatively rare complication in patients undergoing heart valve replacement, whether for biological or mechanical prostheses. The leak may be central, paravalvular or both. Mild leak, with a low risk for pathologic consequences, may be found in a large proportion of heart valve prostheses. Provided no hemodynamic changes occur, mild leaks are not clinically significant.

Genoni et al1 found a 12.% prevalence of leak among 598 patients, and the symptoms most commonly related to this condition were fatigue (67%), vertigo (55%), and functional class III/IV dyspnea (38%)1.

Jindani et al's study2, in turn, found a 2.5% prevalence of prosthetic valve leak among a total of 1,175 prostheses (735 of which were mechanical and 440 biological), and this complication corresponded to 35% of all causes of prosthesis failure. Past medical history of mitral regurgitation, infective endocarditis, acute myocardial infarction, heavily calcified aortic annulus, and Marfan syndrome were the risk factors associated with a higher prevalence of leak2.

Given the importance of prosthetic valve leak among the complications of heart valve surgeries, it is hypothesized that this is a significant predictor of reoperation. The degree of leak seems to be implicated in early reoperation. However, no studies correlating the degree of prosthetic valve leak with possible postoperative events such as reoperation, infection or death are available.

Objective

To compare the postoperative outcome of patients with severe or mild/moderate prosthetic valve leak, and to verify whether differences in the clinical outcome of these patients exist in relation to the severity of the prosthetic valve leak.

Methods

In this retrospective study we analyzed the medical records from the database of the Clinical Unit of Heart Valve Disease of our institution, and other clinical data available in its electronic system. The following data were not available in these sources, and were therefore not analyzed: a) surgeries or clinical outcome of patients treated outside the institution; b) test results not available in the paper medical record that were being processed for inclusion in the electronic system by the time of data collection.

Inclusion criteria

• Patients undergoing heart valve surgery between 1999 and 2001 (called "Surgery 1") who presented at least mild prosthetic valve leak (central and/or paravalvular), whether in biological or mechanical prosthesis;

• Surgery 1 was not necessarily the first heart valve surgery the patients had undergone in their lives;

• Leak may have occurred in the postoperative period of Surgery 1 or this surgery may have been performed precisely to correct a preexisting prosthetic valve leak.

Therefore, three possible situations could have occurred for each patient, as shown in Figure 1.


Exclusion criteria

Patients, who, despite meeting the inclusion criteria, had medical records with missing data that would affect the characterization of their clinical outcome or data analysis, were excluded from the study.

The leak degree was determined by pulsed and color Doppler according to the usual recommendations of the American Society of Echocardiography.

Patient groups

Patients who met the inclusion criteria and had medical records with complete data were distributed into two groups, according to the degree of prosthetic valve leak:

• Mi/Mo GROUP: patients presenting mild or moderate prosthetic valve leak.

• Sev GROUP: patients presenting severe prosthetic valve leak.

For group distribution purposes, the highest leak degree throughout the patient's clinical / echocardiographic history was considered.

Patient selection

The patient selection process is summarized in Figure 2. A total of 1,350 medical records from patients undergoing heart valve surgery in our institution in the period between 1999 and 2001 were selected. Data from 185 patients who met the inclusion criteria of the protocol were evaluated. In accordance with the exclusion criteria, a total of 58 patients were enrolled in the study, 36 of whom in the Mi/Mo group and 22 in the Sev group.


Variables analyzed

Demographic, clinical, laboratory and echocardiographic variables were analyzed in both groups, namely:

• Demographic variables: age, gender, weight, and date of death, when applicable;

• Variables related to the type of heart valve disease in the preoperative period of Surgery 1;

• Clinical variables: preoperative diagnosis of Surgery 1, date of Surgery 1, date of hospital discharge; date of occasional reoperations, number of heart valve surgeries performed throughout life, comorbidities;

• Laboratory variables: serum levels of hemoglobin, hematocrit, creatinine, BUN, and glucose;

• Echocardiographic variables: diagnosis related to the valve(s) affected and its classification as "mild", "moderate" or "severe".

Statistical analysis

Descriptive analysis of the data obtained included mean and standard deviation or percentage, depending on the type of variable analyzed. Data collected for the groups were compared using the non-paired Student's t test, Fischer test and chi square test with Yates continuity correction (for 2x2 tables, 1 degree of freedom), all two-tailed. P values were calculated for each variable analyzed, and so were the odds ratio (OR) for the Sev group in relation to the Mi/Mo group, and the 95% confidence interval (95%CI) for the data to which they could be applied. P values < 0.05 or OR > 1.5 were considered statistically significant. Calculations were made using the Microsoft Excel 2000 (Microsoft Corp.), Odds Ratio Generator 1.0 (Devilly, G.J.; 2005) and FastStatistics 2.0 (FateSoft) software programs.

Results

Of the 1,350 patients undergoing heart valve surgery in our institution between 1999 and 2001, 185 (13.7%) presented with prosthetic valve leak, which was graded from mild to severe. Most of the cases (86%) were paravalvular leaks. Considering the patients effectively selected for the study (n=58), the follow-up time was 4.49±2.98 years in the Mi/Mo group and 3.76±4.74 years in the Sev group (p=0.5167).

Mi/Mo and Sev group demographics are shown in Table 1. No statistically significant difference was found between the groups regarding age, gender, weight, or follow-up time in the study. In the preoperative period of Surgery 1, 31 patients from the Mi/Mo group had native valves, and five had prosthetic valves, whether with or without leak. In the Sev group, five patients had native valves and 17 had prosthetic valves, whether with or without leak (p<0.001, OR: 21.08 [95%CI 5.4 – 81.12] and RR: 5.56 [2.69 – 11.2]). This goes to show that the performance of surgical prosthetic valve replacement in patients already implanted with prosthesis increases by 5.56 times the risk of significant prosthetic valve leak in the postoperative period.

Clinical and echocardiographic information of the patients selected are shown in Table 2. The patients did not differ as to the probability of death of any cause after Surgery 1 (p = 0.5238). We observed that patients with severe prosthetic valve leak had a 2.35-time higher probability of reoperation than those with mild/moderate leak. However, the time for reoperation was surprisingly shorter (25.25±22.43 days) for the patients of the Mi/Mo group than for those of the Sev group (79.80±42.09 days) (p<0.001). In both groups, endocarditis was the major cause of reoperation, and biological aortic prostheses were those which more frequently presented leak, followed by biological mitral prostheses. Sixteen patients (72.7%) of the Sev group already presented prosthetic valve leak in the preoperative period of Surgery 1, in comparison with five patients (13.9%) of the Mi/Mo group. Therefore, we can observe that although the causes for the performance of Surgery 1 had been different, all patients who presented some prosthetic valve dysfunction in the Mi/Mo group also presented associated prosthetic valve leak, and most (16/17; 94.1%) of the patients of the Sev group with some prosthetic valve dysfunction also presented associated prosthetic valve leak. One patient in the Sev group did not present paravalvular or central prosthetic valve leak, despite undergoing surgical heart valve prosthesis replacement.

Table 2

The analysis of the Mi/Mo group showed a mean interval of 353±624 days between Surgery 1 and the diagnosis of prosthetic valve leak among the patients who presented leak after Surgery 1, whether or not presenting leak before this surgery. As regards the Sev group, the interval between Surgery 1 and the echocardiographic diagnosis of severe prosthetic leak was calculated at 230±433 days among patients in whom significant leak was absent in the preoperative period, but was present in the postoperative period of Surgery 1. However, the p value was not statistically significant (p=0.380).

In relation to the laboratory variables analyzed, no statistically significant difference was observed between the groups (Table 3).

Comparison of the effectiveness of surgical prosthetic valve leak correction in the two groups is shown in Table 4. Effectiveness (that is, how effective surgery was to fully resolve the leak) was calculated at 40% (2/5) in the Mi/Mo group. In the Sev group, effectiveness was 21.4% (3/14, already excluding the two patients who presented leak in Surgery 1, but whose postoperative data were not available). This corresponds to an OR = 2.44 (95% CI = 0.27-22.1), which leads us to conclude that there is an approximately 2.44-time increase in the chance of the surgical correction of prosthetic valve leak to be effective among patients with mild or moderate leak in relation to patients with severe leak.

No Mi/Mo group patients with mild or moderate leak in Surgery 1 presented severe leak in the postoperative period (three patients among the five who presented leak in Surgery 1 remained with leak, albeit mild or moderate, in the postoperative period). Among the 11 patients of the Sev group who had severe leak at Surgery 1 and progressed with some degree of leak in the postoperative period, the following prevalences of prosthetic valve leak were observed, according to its severity: three with mild degree (27.3%), five with moderate degree (45.4%); three with severe degree (27.3%).

Discussion

The present study evaluated the profile of patients who presented severe prosthetic valve leak in relation to patients with mild or moderate leak in the postoperative period of heart valve surgery.

An OR = 16.5 (95% CI = 4.37-62.60) for the presence of leak as a preoperative diagnosis of Surgery 1 in the Sev group in relation to the Mi/Mo group confirmed that surgical prosthetic valve replacement is more frequent among patients with severe leak than among those with mild or moderate leak. Most of the patients (86.1%) with mild or moderate leak did not undergo Surgery 1 due to leak, but developed leak after this surgery, whether or not undergoing surgery later in time. Leak was the most frequent (72.7%) cause of Surgery 1 among patients with severe leak. Additionally, patients with severe leak have a greater change of undergoing reoperation after surgical valve replacement, regardless of the reason for surgery (OR = 2.35; 95%CI = 0.56-9.94).

A statistically significant difference (p<0.001) was found for the time elapsed between Surgery 1 and reoperation in both groups. The Sev and Mi/Mo groups underwent reoperation 79.8±42.09 days and 25.25±22.43 days after Surgery 1, respectively. This is surprising, because we expected to find a shorter interval for reoperation in the Sev group. A hypothesis to explain this finding is that patients from the Sev group could be at higher surgical risk than those from the Mi/Mo group, which could occasionally postpone reoperation in the Sev group.

In both groups, more than 50% of the cases of prosthetic valve leak occurred in biological aortic prostheses, followed by biological mitral prostheses, in disagreement with Akins et al3 findings of a higher frequency of mitral leak (68%) in a series of 136 heart valve replacements. Also interesting is the fact that most of the cases that progressed with significant leak in the postoperative period of Surgery 1 presented prosthesis dysfunction, whether regurgitation alone or associated with stenosis (Table 1).

The comparison of the time elapsed between Surgery 1 and the diagnosis of prosthetic valve leak among patients who did not present leak at the first surgery showed a tendency to a shorter time for the diagnosis of severe leak in relation to less severe degrees of prosthetic valve leak (p=0.552), which is understandable in light of the greater severity and symptoms associated with severe prosthetic valve leak. Genoni et al1 demonstrated that among 598 patients, 22% of the cases of paravalvular leak were diagnosed in the first postoperative week, and 74% up to the first postoperative year. In our study, we verified that the mean time for the diagnosis of prosthetic valve leak in both groups was shorter than one year after surgery (353±624 days in the Mi/Mo group and 230±433 days in the Sev group).

Akin et al3 verified that 50% of the patients undergoing surgical correction of prosthetic valve leak had already undergone at least one cardiac surgery. In our study, we found 34.5% of the patients undergoing at least two heart valve surgeries in life. However, we should point out that our calculation is different from that of Akins et al3 for considering every surgery performed throughout the patients' lives (and not only those performed before the surgical leak correction) and for being restricted to heart valve surgeries.

Complete resolution of leak after surgical heart valve replacement was less frequent among patients with severe leak (21.4%) than among patients with mild or moderate leak (40%) (OR = 0.5357, 95%CI = 0.07-4.2). However, there was a significant leak reduction by 72.7% in the cases with severe preoperative leak which progressed with some leak in the postoperative period of Surgery 1, naturally resulting in clinical improvement4. Thus, as expected, the effectiveness of the surgical correction of prosthetic valve leak is higher in mild or moderate cases. Despite this fact, the percentage of patients progressing without prosthetic valve leak after Surgery 1 (40% in the Mi/Mo group and 21.4% in the Sev group; Table 4) was considerably lower than the values found by Akins et al3. In this study, only 16% of the patients presented leak recurrence up to 10 years after surgical correction of the primary leak3. Nevertheless, we should consider that the study did not include the cases of leak caused by endocarditis; also, it had a longer follow-up period (15 years)3.

No consensus regarding the best way to treat prosthetic valve leak is available yet, especially in mild/moderate cases. Genoni et al study1 found mortality rates of 26% among patients who received conservative medical treatment and of 12% among those undergoing surgery. Akins et al3 concluded that the morbidity and mortality rates resulting from the surgical correction of prosthetic valve leak are acceptable. Some studies discuss the use of minimally invasive surgical techniques for heart valve replacement3,5 or improvements in the techniques using the open surgical approach in leak correction, especially for valve annulus reinforcement6.

In addition to leak, other complications related to prosthetic valves contribute to the morbidity and mortality of patients undergoing surgical heart valve replacement. Of these, the most common are thromboembolism, hemorrhage, hemolysis, infectious endocarditis, heart valve failure and reoperation7-10. Ten years after heart valve replacement, up to 50% of the patients require reoperation or die of complications related to the prosthetic heart valves. There is usually no difference between mechanical and biological prostheses, but the frequency and nature of the complications related to the prostheses vary according to type, model, and valve position, as well as to each patient's characteristics4,11-15.

By quantifying the comparative odds ratios between patients who presented varying degrees of prosthetic valve leak, the present study contributes to a better knowledge of its clinical outcome and provides information to guide therapies and establish prognoses. Although Genoni et al1 concluded that the surgical treatment of prosthetic valve leak seems to be better than medical treatment, the present study shows that the risk of reoperation and the effectiveness of surgical correction of heart valve replacement vary according to the leak degree. Furthermore, our study also contributed with the observation of the presence of an expressive number of cases of endocarditis as the cause of reoperation associated both with the mild/moderate leak group (75%) and with the severe leak group (60%). Therefore, we point out that it is fundamental to consider the possibility of endocarditis in patients with postoperative prosthetic valve leak16.

Our study was limited by the number of patients enrolled in each of the groups (n=36 and 22 in the Mi/Mo and Sev groups, respectively), so that statistically significant p values or odds ratios (OR) could not be obtained for some of the variables analyzed. This was due to the fact that prosthetic valve leak is relatively uncommon in our institution. However, with the values found we can point to tendencies and suggest further studies on this important topic. Additionally, it is important to recognize that a longer follow-up period may be necessary3 to compare the morbidity and mortality between the groups, since we analyzed approximately 4.49±2.98 years of the Mi/Mo group and 3.76±4.74 years of the Sev group. Other studies demonstrated a mean survival of only 30% 10 years after surgical correction of prosthetic valve leak3.

Conclusions

(1) Surgical correction of prosthetic valve leak is more frequent in patients with severe leak than in those with mild or moderate leak. The presence of prosthesis dysfunction is a predisposing factor for the development of severe postoperative leak.

(2) Patients who already had or who will develop severe prosthetic valve leak have a higher chance of undergoing reoperation after surgical heart valve replacement, regardless of the reason for surgery.

(3) Severe prosthetic valve leak is more difficult to resolve completely after surgical treatment.

(4) Endocarditis was the most common cause of reoperation, regardless of the degree of prosthetic valve leak.

(5) A higher incidence of prosthetic valve leak was observed in aortic bioprostheses in the series of surgeries performed in our institution.

Potential Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Sources of Funding

There were no external funding sources for this study.

Study Association

This study is not associated with any post-graduation program.

References

  • 1. Genoni M, Franzen D, Vogt P, Seifert B, Jenni R, Kunzli A, et al. Paravalvular leakage after mitral valve replacement: improved long-term survival with aggressive surgery? Eur J Cardiothorac Surg. 2000; 17 (1): 14-9.
  • 2. Jindani A, Neville EM, Venn G, Williams BT. Paraprosthetic leak: a complication of cardiac valve replacement. J Cardiovasc Surg. 1991; 32 (1): 503-8.
  • 3. Akins CW, Bitondo JM, Hilgenberg AD, Vlahakes GJ, Madsen JC, MacGillivray TE. Early and late results of the surgical correction of cardiac prosthetic paravalvular leaks. J Heart Valve Dis. 2005; 14 (6): 799-800.
  • 4. Bottio T, Rizzoli G, Thiene G, Nesseris G, Casarotto D, Gerosa G. Hemodynamic and clinical outcomes with the Biocor valve in the aortic position: an 8-year experience. J Thorac Cardiovasc Surg. 2004; 127 (6): 1616-23.
  • 5. Boudjemline Y, Pineau E, Borenstein N, Behr L, Bonhoeffer P. New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves. Eur Heart J. 2005; 26 (19): 2013-7.
  • 6. Linden BC, Schumacher CW, MacIver RH, Mrachek JP, Bianco RW. Paravalvular leaks around prosthetic valves implanted in the mitral position: technical refinements of the ovine model. J Heart Valve Dis. 2003; 12 (3): 400-5.
  • 7. Butany JW, Naseemuddin A, Nair V, Borger MA, Daniel L. Infective endocarditis in a Hancock bioprosthetic heart valve. J Card Surg. 2005; 20 (4): 389-92.
  • 8. Goldsmith I, Lip GYH, Patel RL. Evaluation of the Sorin bicarbon bileaflet valve in 488 patients (519 prostheses). Am J Cardiol. 1999; 83 (7): 1069-74.
  • 9. Mansuroglu D, Ömeroglu SN, Izgi A, Ercan F, Yaymaci B, Basaran Y, et al. LDH levels and left atrial ultrastructural chances in patients with mitral paraprosthetic regurgitation. J Card Surg. 2005; 20 (3): 229-33.
  • 10. Nashef SAM, Sethia B, Turner MA, Davidson KG, Lewis S, Bain WH. Bjork-Shiley and Carpentier-Edwards valves: a comparative analysis. J Thorac Cardiovasc Surg. 1987; 93: 394-404.
  • 11. Davila-Roman VG, Waggoner AD, Kennard ED, Holubkoc R, Jamieson WR, Englberger L, et al. Artificial valve endocarditis reduction trial echocardiography study: prevalence and severity of paravalvular regurgitation in the Artificial Valve Endocarditis Reduction Trial (AVERT) echocardiography study. J Am Coll Cardiol. 2004; 44 (7): 1467-72.
  • 12. Englberger L, Schaff HV, Jamieson WR, Kennard ED, Im KA, Holubkov R, et al. AVERT Investigators. Importance of implant technique on risk of major paravalvular leak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT). Eur J Cardiothorac Surg. 2005; 28 (6): 838-43.
  • 13. Kuwaki K, Tsukamoto M, Komatsu K, Morishita K, Sakata J, Abe T. Simultaneous aortic and mitral valve replacement: predictors of adverse outcome. J Heart valve Dis. 2003; 12 (2); 169-76.
  • 14. Rizzoli G, Bottio T, Vida V, Nesseris G, Caprili L, Thiene G, et al. Intermediate results of isolated mitral valve replacement with a Biocor porcine valve. J Thorac Cardiovasc Surg. 2005; 129 (2): 322-9.
  • 15. Ruel M, Kulik A, Rubens FD, Bedard P, Masters RG, Pipe AL, et al. Late incidence and determinants of reoperation in patients with prosthetic heart valves. Eur J Cardiothorac Surg. 2004; 25 (3): 364-70.
  • 16. Sadeghi H. Dysfunctions of heart valve prostheses and their surgical treatment. Schweiz Med Wochenschr. 1987; 117 (43): 1665-70.
  • Correspondência:

    Roney Orismar Sampaio
    Rua Comandante Garcia d'Avila, 412, Morumbi
    05.654040, São Paulo, SP, Brasil
    E-mail:
  • Publication Dates

    • Publication in this collection
      22 Oct 2009
    • Date of issue
      Sept 2009

    History

    • Received
      17 Mar 2008
    • Reviewed
      08 Sept 2008
    • Accepted
      27 Oct 2008
    Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
    E-mail: revista@cardiol.br