Validity and equivalence of the Portuguese version of the Veterans Specific Activity Questionnaire

Abstracts

BACKGROUND: The Veterans Specific Activity Questionnaire (VSAQ) has been used to individualize exercise testing (ET) and to indirectly assess cardiorespiratory fitness (CRF) in epidemiological studies. Nevertheless, there is no validated Portuguese version. OBJECTIVE: To verify the criterion-related validity and the measurement equivalence of a Portuguese version of VSAQ in 95 individuals, 8 women (aged 69 ± 7 years) referred to ET. METHODS: The subjects performed a cardiopulmonary test with incremental to maximal exercise on a cycle ergometer. The correlation between VSAQ score and Maximum Measured and Estimated METs was compared to results from other studies. The VSAQ Nomogram was calculated and its results were compared to CRF real values by linear regression. Limits of concordance and mean differences (biases) were assessed according to the Bland Altman methodology. RESULTS: The VSAQ scores were significantly correlated to the Measured METs (r = 0.64) and Estimated METs (r = 0.67), results that were equivalent to those obtained by the original versions. The VSAQ Nomogram presented multiple R of 0.78 (Measured MET) and 0.80 (Estimated MET). However, the Nomogram seems to have underestimated CRF values greater than 6 METs. CONCLUSION: The VSAQ version confirmed its validity and equivalence to the original version, especially when evaluating individuals with coronary heart disease and older adults.

Validity of tests; physical fitness; exercise test; cardiovascular diseases


FUNDAMENTO: O Veterans Specific Activity Questionnaire (VSAQ) tem sido utilizado para a individualização de testes ergométricos (TE) e para avaliar indiretamente a aptidão cardiorrespiratória (ACR) em estudos epidemiológicos. Apesar disso, ainda não há versão em português validada. OBJETIVO: Verificar a validade de critério da versão em português do VSAQ e examinar a equivalência de mensuração dessa versão em 95 indivíduos, sendo 8 mulheres (69 ± 7 anos), com indicação para a realização de TE. MÉTODOS: Os indivíduos realizaram teste cardiopulmonar de exercício progressivo máximo em ciclo-ergômetro. A correlação do escore do VSAQ com o MET Máximo Medido e Estimado foi comparada com os resultados de outros estudos. O Nomograma VSAQ foi calculado e seus resultados comparados com os valores reais da ACR por regressão linear. Limites de concordância e as diferenças médias (vieses) foram avaliados segundo a metodologia proposta por Bland e Altman. RESULTADOS: Os escores obtidos através do VSAQ correlacionaram-se de forma significativa com o MET máximo medido (r = 0,64) e estimado (r = 0,67), resultados equivalentes àqueles obtidos com versões originais. O nomograma VSAQ obteve resultados com R múltiplo de 0,78 (para MET medido) e 0,80 (para MET estimado). O nomograma, entretanto, parece subestimar os valores de indivíduos com ACR acima de 6 MET. CONCLUSÃO: A versão do VSAQ confirmou-se válida e equivalente à versão original, especialmente para avaliação de indivíduos cardiopatas e de idade avançada.

Validade dos testes; aptidão física; teste de esforço; doenças cardiovasculares


FUNDAMENTO: El Veterans Specific Activity Questionnaire (VSAQ) ha sido utilizado para la individualización de tests ergométricos (TE) y para evaluar indirectamente la aptitud cardiorrespiratoria (ACR) en estudios epidemiológicos. A pesar de eso, aun no hay versión en portugués validada. OBJETIVO: Verificar la validez de criterio de la versión en portugués del VSAQ y examinar la equivalencia de medición de esa versión en 95 individuos, siendo 8 mujeres (69 ± 7 años), con indicación para realización de TE. MÉTODOS: Los individuos realizaron test cardiopulmonar de ejercicio progresivo máximo en cicloergómetro. La correlación del escore del VSAQ con el MET máximo medido y estimado fue comparada con los resultados de otros estudios. El nomograma VSAQ fue calculado y sus resultados comparados con los valores reales de la ACR por regresión lineal. Límites de concordancia y las diferencias medias (sesgos) fueron evaluados según la metodología propuesta por Bland y Altman. RESULTADOS: Los escores obtenidos a través del VSAQ se correlacionaron de forma significativa con el MET máximo medido (r = 0,64) y estimado (r = 0,67), resultados equivalentes a aquellos obtenidos con versiones originales. El nomograma VSAQ obtuvo resultados con R múltiplo de 0,78 (para MET medido) y 0,80 (para MET estimado). El nomograma, entre tanto, parece subestimar los valores de individuos con ACR encima de 6 METs. CONCLUSIÓN: La versión del VSAQ se confirmó válida y equivalente a la versión original, especialmente para evaluación de individuos cardíacos y de edad avanzada.

Validez de los tests; aptitud física; test de esfuerzo; enfermedades cardiovasculares


Validity and equivalence of the portuguese version of the Veterans Specific Activity Questionnaire

Geraldo de Albuquerque Maranhão-NetoI; Antonio Carlos Ponce de LeonII; Paulo de Tarso Veras FarinattiIII

IPós-Graduação em Saúde Coletiva, Departamento de Epidemiologia, Instituto de Medicina Social - Universidade do Estado do Rio de Janeiro

IILaboratório de Atividade Física e Promoção da Saúde, Instituto de Educação Física e Desportos - Universidade do Estado do Rio de Janeiro

IIIPrograma de Pós-Graduação em Ciências da Atividade Física - Universidade Salgado de Oliveira, Rio de Janeiro, RJ - Brazil

Mailing address

ABSTRACT

BACKGROUND: The Veterans Specific Activity Questionnaire (VSAQ) has been used to individualize exercise testing (ET) and to indirectly assess cardiorespiratory fitness (CRF) in epidemiological studies. Nevertheless, there is no validated Portuguese version.

OBJECTIVE: To verify the criterion-related validity and the measurement equivalence of a Portuguese version of VSAQ in 95 individuals, 8 women (aged 69 ± 7 years) referred to ET.

METHODS: The subjects performed a cardiopulmonary test with incremental to maximal exercise on a cycle ergometer. The correlation between VSAQ score and Maximum Measured and Estimated METs was compared to results from other studies. The VSAQ Nomogram was calculated and its results were compared to CRF real values by linear regression. Limits of concordance and mean differences (biases) were assessed according to the Bland Altman methodology.

RESULTS: The VSAQ scores were significantly correlated to the Measured METs (r = 0.64) and Estimated METs (r = 0.67), results that were equivalent to those obtained by the original versions. The VSAQ Nomogram presented multiple R of 0.78 (Measured MET) and 0.80 (Estimated MET). However, the Nomogram seems to have underestimated CRF values greater than 6 METs.

CONCLUSION: The VSAQ version confirmed its validity and equivalence to the original version, especially when evaluating individuals with coronary heart disease and older adults. (Arq Bras Cardiol. 2011; [online].ahead print, PP.0-0)

Keywords: Validity of tests; physical fitness; exercise test; cardiovascular diseases.

Introduction

Low levels of cardiorespiratory fitness (CRF) have been considered a risk factor for morbimortality1,2. Determining the CRF through an exercise test (ET) makes this type of assessment very important, as it is used as an important diagnostic and prognostic tool3.

In spite of its importance, the ET can be made unattainable by several difficulties, such as the time spent to perform it and the high cost of material and human resources4,5. In at-risk populations, such as the elderly and those with heart disease, the ET performance is impaired by the lower functional capacity and frailty exhibited by these individuals6,7.

Thus, alternatives have been created, especially through the use of submaximal tests, questionnaires on symptoms and models without exercise to estimate CRF. Although these alternatives very often generate only modest correlations, many tools have demonstrated considerable prognostic value. One of the main tools found in the literature is the Veterans Specific Activity Questionnaire (VSAQ)7. Initially developed for the individualization of the ET8, using a predictive equation together with the age variable (VSAQ Nomogram), the questionnaire has also been used to estimate CRF of revascularized individuals9, as an indicator or mortality risk in male individuals with an ET indication10.

Due to the importance of the VSAQ, in 2008, Maranhão Neto et al11 carried out the transcultural adaptation of the scale. This investment was justified by the fact that, until then, in spite of the use of the VSAQ in national publications12,13, this necessary adaptation had been carried out. The VSAQ adaptation process demonstrated that the version developed in Portuguese showed very good equivalence with the original version, as well as good reproducibility11. However, it is still necessary to analyze the equivalence of measurement - once demonstrated that the validity of the Portuguese version is similar to that of the original version of the tool, its clinical and epidemiological applicability would be ratified, especially in individuals with heart disease.

Thus, the present study aimed at: a) performing the criterion validation of VSAQ in individuals with ET indication; b) verifying the measurement equivalence of this version; and c) verifying the criterion validity of the VSAQ Nomogram in order to analyze its clinical applicability in individuals with heart disease.

Methods

Sampling

The sample was selected among elderly individuals treated from 2005 to 2006 at the Outpatient Clinic of Núcleo de Atenção ao Idoso (NAI) of Universidade Aberta da Terceira Idade (UnATI-Uerj). The following inclusion criteria were established for participating in the present study: all participants had stable heart disease, were asymptomatic, had no electrocardiographic alterations at rest and had been followed for at least six months at the outpatient clinic. A total of 95 individuals (8 women) aged 60 to 85 years (69 ± 7 years) met the inclusion criteria. All participants signed the Free and Informed Consent Form, according to the recommendations of the Helsinki Convention and Decree #.196/96 of the National Council of Health (Conselho Nacional de Saúde) for researches involving human subjects. The study was approved by the Institutional Board. There was no conflict of interest related to the present study.

Procedures

All participants answered the VSAQ (Chart 1). The Portuguese version used in the study was based on the proposal revised by Myers et al14. Body mass was obtained using a digital FilizolaTM ID 1500 scale (Filizola, São Paulo, Brazil) with a minimum capacity of 2.5 kg and maximum capacity of 150 kg, with precision of 1 g. Height was determined using a wooden stadiometer with precision of 0.1 cm. The body mass index (BMI) was calculated based on the measured weight and height.


The individuals were submitted to a maximal cardiopulmonary exercise test in a Cateye EC-1600 lower-limb cycle ergometer (Cat Eye, Tokyo, Japan) using an individualized ramp protocol. For the analysis of expired gases, a VO2000 metabolic analyzer was used (MedGraphics, USA). The professionals that conducted the tests were blinded to the results obtained at the VSAQ. The workloads in Watts were selected based on the estimated maximum workload capacity, aiming at obtaining maximal exertion between 6 and 12 minutes, according to the recommendations of the American Heart Association3. Continuous monitoring was carried out through 12-lead electrocardiography (ECG) (MicromedTM, Brasília, Brazil), and blood pressure measurements at rest and every test minute were carried out with a WelchAlln aneroid sphygmomanometer manufactured by TycosTM (Arden, USA).

Criteria for test interruption were established according to the recommendations in the literature15. The test was interrupted due to maximum voluntary exertion. No threshold was pre-established regarding the heart rate (HR) value to be attained. Tests interrupted due to clinical reasons or considered to be submaximal would be excluded from the analysis.

The maximum MET value was calculated based on the maximum oxygen consumption during the test (VO2 peak) divided by 3.5, and the estimated maximum MET was determined based on the equations of the American College of Sports Medicine, considering the mechanical resistance of the cycle ergometer at the highest workload attained (in Watts)16.

Statistical analysis

After confirming the normality of data by the univariate analysis, the correlation between the scores obtained at the VSAQ and the maximum measured and estimated MET variables was tested by calculating Pearson's r. Pearson's correlation analysis was also carried out between the values obtained for maximum MET and the result of the VSAQ Nomogram. The result was calculated based on the following equation: Maximum MET = 4.7 + 0.97(VSAQ score) - 0.06 (age in years)7.

The visual analysis was carried out using the identity and Bland Altman plots to evaluate whether the VSAQ Nomogram varied according to the maximum MET levels (heteroscedasticity). To help this analysis, 95% limits of concordance (95%LC) were established, calculated from the mean difference between the reported and the measured ± the standard deviation of the differences multiplied by 1.96. All calculations were carried out using the StataTM10.1 Standard Edition for Windows software (Texas, USA). Statistical significance was set at p < 0.05.

Results

The sample characteristics, at rest and during the ET, are shown in Table 1. The mean duration of the ET was 9.6 ± 1.8 minutes and there were no complications during or after the tests.

The correlations obtained between the VSAQ scores and measured and estimated maximum MET values are shown in Tables 2 and 3, as well as the correlations reported by other studies.

The correlations between the VSAQ Nomogram and the measured and estimated MET are shown in Figure 1. The Bland-Altman plots (Figure 2) show, as dotted lines, the 95%LC values, which were respectively, -3.07 and +1.7; between Nomogram and Measured MET, and -2.98 and +1.01 for Estimated MET.



Discussion

The highest values observed for estimated in comparison with the measured MET (Table 1) corroborate the data in the literature, in the sense that, in individuals with heart disease, the CRF is usually overestimated when the VO2 is not directly measured14. These results are also in accordance with previous studies that found higher correlations between VSAQ and estimated MET (Table 3), suggesting that the questionnaire would be better adapted for the measurement of intensity in a treadmill or cycle ergometer than the measurement of VO2peak14.

When comparing the results obtained with the Portuguese version of the VSAQ (Tables 2 and 3), one can observe that they are very similar to those obtained with the original version of the tool, including individuals with similar characteristics of that of the present study (individuals with heart disease and elderly). Such evidence suggests the measurement equivalence of the Portuguese version, presently assessed.

Except for the study by Myers et al19 carried out in individuals with heart failure, which found a correlation of 0.37 between the VSAQ and the VO2 peak, the values depicted in Tables 2 and 3 show that higher correlations are usually observed when the VSAQ is applied to older populations with some cardiovascular impairment.

The results of the present study are in accordance with such evidence and additionally suggest that the use of the cycle ergometer did not seem to affect the association between the VSAQ and the VO2 peak. Previous studies had used the cycle ergometer only in studies with healthy and younger individuals, obtaining coefficients of correlation that varied from 0.46 to 0.5218, which ratifies the idea that the VSAQ might not be so adequate for this population10.

The VSAQ Nomogram to estimate CRF (Figure 1) showed very similar values, both in the measured and estimated MET assessment. The result of 0.80 is very similar to that found by the original study, in which the Nomogram was proposed, and which was developed only from the estimated MET7 (r = 0.81, p < 0.001).

To date, only two studies, which are shown in Tables 2 and 3, had analyzed the Nomogram validity. Myers et al14 reported correlations of 0.50 and 0.63 for measured and estimated MET. Maeder et al20, in turn, found results of 0.56 for measured MET and 0.76 for estimated MET. A probable explanation for the higher similarity between the results of the present study and the original one might be the presence of individuals at very similar age ranges in both studies.

The results demonstrated by the Bland Altman graph analysis (fig. 2) show few values outside the ranges established by the 95%LC, which suggests good precision between the result obtained through the Nomogram and the estimated and measured MET values. Nevertheless, it can be observed that the VSAQ Nomogram tended to underestimate the CRF, especially when the individuals had higher functional capacity (approximately > 6 MET). Further conclusions are limited by the sample size; however, the findings are noteworthy, especially considering that this graph analysis was not carried out in any of the original studies.

Additional studies must be performed to detect which levels of functional capacity the VSAQ would more adequately assess. Larger sample sizes would also help to establish cutoffs and to detect diagnostic criteria, such as sensitivity and specificity.

It is worth mentioning that the results shown in the present study were obtained in individuals with heart disease, mostly of the male sex and older than 60 years. Thus, the VSAQ version would have lower external validity for the assessment of samples consisting of younger individuals and a majority of female individuals.

It is important to mention that the small number of female individuals in the sample was a consequence of the studied period and the established selection criteria. The proportion in the present study (9%) is quite similar to that of other studies, such as the ones by Myers et al7 (2%), Myers et al14 (4%) and Rankin et al17 (14%). Myers et al19 did not include women in their sample and the study with the highest proportion was the one by Maeder et al18 (36%). This evidence suggests that the VSAQ is not often studied in women, even in its original version. Hence, there is a lack of studies on the difference between the sexes regarding the scale criterion validity.

Conclusion

In conclusion, our findings confirm the criterion validity of the Portuguese version of the VSAQ, previously demonstrated by Maranhão Neto et al11, as well as its measurement equivalence. The results obtained in the tool validity were similar to those found for the original version, especially in samples similar to that of the present study (individuals with heart disease and the elderly).

The criterion validity of the Nomogram was also demonstrated and the results obtained were similar to those of the original article, which confirms its applicability, especially in individuals with low CRF.

Thus, the use of the analyzed Portuguese version of the VSAQ is suggested, as it is originally an important tool of clinical and epidemiological significance. As the tool is easy to understand and simple to fill out, it can be used by health professionals to help individualize the ET. In situations where the ET cannot be performed, the VSAQ can replace it in the CRF assessment, both to follow up the physical fitness evolution as well as to detect the morbimortality risk, especially in individuals with cardiopathies.

Acknowledgements

The present study was partially supported by Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), as a grant to P. T. V. Farinatti (process #303018/2003-8) and to Antonio Ponce de Leon (process #309156/2007-6) and by Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro to P. T. V. Farinatti (E26/102.916/2008).

References

  • 1. Blair SN, Kohl HW 3rd, Paffenbarger RS Jr, Clark DG, Cooper KH, Gibbons LW. Physical fitness and all-cause mortality: a prospective study of healthy men and women. JAMA. 1989;262(17):2395-401.
  • 2. Laukkanen JA, Kurl S, Salonen R, Rauramaa R, Salonen JT. The predictive value of cardiorespiratory fitness for cardiovascular events in men with various risk profiles: a prospective population-based cohort study. Eur Heart J. 2004;25(16):1428-37.
  • 3. Gibbons RJ, Balady GJ, Bricker JT, Chaitman BR, Fletcher GF, Froelicher VF, et al. ACC/AHA 2002 guideline update for exercise testing: a report of the American College of Cardiology/American Heart Association task force on practice guidelines. J Am Coll Cardiol. 2002;40(8):1531-40.
  • 4. Ainsworth BE, Richardson MT, Jacobs DR, Leon AS. Prediction of cardiorespiratory fitness using physical activity questionnaire data. Med Exerc Nutr Health. 1992;1:75-82.
  • 5. Matthews CE, Heil DP, Freedson PS, Pastides H. Classification of cardiorespiratory fitness without exercise testing. Med Sci Sports Exerc. 1999;31(3):486-93.
  • 6. Hollenberg M, Ngo LH, Turner D, Tager IB. Treadmill exercise testing in an epidemiologic study of elderly subjects. J Gerontol A Biol Sci Med Sci. 1998;53(4):B259-67.
  • 7. Myers J, Do D, Herber W, Ribisl P, Froelicher VF. A nomogram to predict exercise capacity from a specific questionnaire and clinical data. Am J Cardiol. 1994;73(8):591-6.
  • 8. Gill TM, DiPietro L, Krumholz HM. Role of exercise stress testing and safety monitoring for older persons starting an exercise program. JAMA. 2000;284(3):342-9.
  • 9. Pierson LM, Norton JH, Herbert WG, Pierson ME, Ramp WK, Kiebzak GM, et al. Recovery of self-reported functional capacity after coronary artery bypass surgery. Chest. 2003;123(5):1367-74.
  • 10. McAuley P, Myers J, Abella J, Froelicher V. Evaluation of a specific activity questionnaire to predict mortality in men referred for exercise testing. Am Heart J. 2006;151(4):890.e1-7.
  • 11. Maranhão Neto G de A, de Leon AC, Farinatti P de T. Equivalência transcultural de três escalas utilizadas para estimar a aptidão cardiorrespiratória: estudo em idosos. Cad Saude Publica. 2008; 24(11): 2499-510.
  • 12. Barbosa e Silva O, Sobral Filho DC. Uma nova proposta para orientar a velocidade e inclinação no protocolo em rampa na esteira ergométrica. Arq Bras Cardiol. 2003;81(1):42-7.
  • 13. Costa RVC, Nóbrega ACL, Serra SM, Rego S, Wajngarten M. Influência da massa muscular esquelética sobre as variáveis ventilatórias e hemodinâmicas ao exercício em pacientes com insuficiência cardíaca crônica. Arq Bras Cardiol. 2003;81(6):576-80.
  • 14. Myers J, Bader D, Madhavan R, Froelicher V. Validation of a specific activity questionnaire to estimate exercise tolerance in patients referred for exercise testing. Am Heart J. 2001;142(6):1041-6.
  • 15. Andrade J, Brito FS, Vilas-Boas F, Castro I, Oliveira JA, Guimarães JI, et al; Sociedade Brasileira de Cardiologia. II Diretrizes sobre teste ergométrico. Arq Bras Cardiol. 2002; 78(supl 2):3-16.
  • 16. American College of Sports Medicine. Guidelines for exercise testing and prescription. 6 th ed. Baltimore,MD: Lippincott, Williams&Wilkins; 2000.
  • 17. Rankin SL, Briffa TG, Morton AR, Hung J. A specific activity questionnaire to measure the functional capacity of cardiac patients. Am J Cardiol.1996; 77(14):1220-3.
  • 18. Maeder M, Wolber T, Atefy R, Gadza M, Ammann P, Myers J, et al. Impact of the exercise mode on exercise capacity: bicycle testing revisited. Chest. 2005;128(4):2804-11.
  • 19. Myers J, Zaheer N, Quaglietti S, Madhavan R, Froelicher V, Heidenreich P. Association of functional and health status measures in heart failure. J Card Fail. 2006;12(6):439-45.
  • 20. Maeder M, Wolber T, Atefy R, Gadza M, Ammann P, Myers J, et al. A nomogram to select the optimal treadmill ramp protocol in subjects with high exercise capacity: validation and comparison with the Bruce protocol. J Cardiopulm Rehabil. 2006;26(1):16-23.
  • Correspondência:

    Geraldo de Albuquerque Maranhão-Neto
    Av. Ayrton Senna, 270/1807 Bloco 1 - Barra da Tijuca
    22793-000 - Rio de Janeiro, RJ - Brasil