Pacemaker Reuse in Portuguese Speaking Countries: A Clinical Reflection

Abstract

There is a gap between high-income countries and others in terms of access to medical cardiac devices, such as pacemakers and implantable cardioverter defibrillators. Costs are one of the main barriers to the use of cardiac devices in these countries. There are international initiatives that aim to reduce the gap. The reuse of pacemakers has been discussed as a possible alternative to this problem. The concept of reusing pacemakers is not new; however, recent studies have proven to be safe, ethical, and effective for those who need cardiac implantable electronic devices and cannot afford them. Part of the Portuguese-speaking countries, especially in Africa, need an immediate response that benefits their countless patients who suffer from treatable arrhythmias.

Cardiac Pacing Artificial/trends; Pacemaker, Artificial; Defibrillators, Implantable; Public Health,Administration; Health Status Disparities

Resumo

Há uma enorme disparidade entre os países de alta renda e outros em termos de acesso a dispositivos médicos cardíacos, como marca-passos e desfibriladores implantáveis. Os custos são uma das principais barreiras ao uso de dispositivos cardíacos nesses países. Existem iniciativas internacionais que visam reduzir essa disparidade, e o reuso de marca-passos tem sido discutido como uma possível alternativa. O conceito de reutilização de marca-passos não é novo; entretanto, estudos recentes têm se mostrado seguros, éticos e eficazes para aqueles que precisam de dispositivos eletrônicos cardíacos implantáveis e não tem como adquiri-los. Parte dos países de língua portuguesa, especialmente na África, precisam de uma resposta imediata que beneficie seus inúmeros pacientes que sofrem de arritmias tratáveis.

Estimulação Cardíaca Artificial/tendências; Marca-Passo Artificial; Desfibriladores Implantáveis; Administração em Saúde Pública; Disparidade nos Níveis de Saúde

Introduction

Artificial cardiac pacing and electrophysiology are well established and internationally recognized medical activities, but there is still a gap between high-income countries and others in terms of access to medical devices. The reuse of pacemakers has been discussed as a possible alternative to this problem.11.Baman TS, Eagle KA. Cardiac device reutilization: Is it time to “go green” in underserved countries?. Pacing Clin Electrophysiol. 2011;34(6):651–2. doi: 10.1111/j.1540-8159.2011.03060.x However, even though there is an evident need in some areas, low- and middle-income Portuguese-speaking countries still do not have defined public policies on this subject or started broad discussions on this topic in their medical societies. This review proposes to discuss what is known about this theme, promoting the possibility of discussing the implementation of pacemaker reuse, particularly in regions with greater difficulty in acquiring these cardiac devices.

Disparities in artificial cardiac pacing

Since the 1950s, when the first pacemakers were implanted, there has been an unprecedented advance in the treatment of heart disease.22.Ward C, Henderson S, Metcalfe NH. A short history on pacemakers. Int J Cardiol. 2013;169(4):244–8. doi: 10.1016/j.ijcard.2013.08.093 Although the technology has greatly advanced, it is still expensive and inaccessible for many low- and middle-income countries. For example, the annual pacemaker implant rate is more than 700 per million inhabitants in France, Sweden, and the United States, while it is less than 7 per million in Pakistan, the Philippines, and Indonesia, and less than 3 per million in Africa. Based on those numbers, it is estimated that up to one million people die each year without access to therapy for severe bradyarrhythmia in the world.33.Mond HG, Proclemer A. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: Calendar year 2009 - A world society of Arrhythmia’s project. Pacing Clin Electrophysiol. 2011;34(8):1013–27. doi: 10.1111/j.1540-8159.2011.03150.x

4.Sinha SK, Sivasambu B, Yenokyan G, Crawford TC, Chrispin J, Eagle KA, et al. Worldwide pacemaker and defibrillator reuse: Systematic review and meta-analysis of contemporary trials. Pacing Clin Electrophysiol. 2018;41(11):1500–7. doi: 10.1111/pace.13488
-55.Runge MW, Baman TS, Davis S, Weatherwax K, Goldman E, Eagle KA, et al. Pacemaker recycling: A notion whose time has come. World J Cardiol. 2017;9(4):296-303. doi: 10.4330/wjc.v9.i4.296 Cost is one of the main barriers to the use of cardiac devices in these countries. A pacemaker costs up to US$2,500.00, which is more than the per capita income of many low- and middle-income countries.55.Runge MW, Baman TS, Davis S, Weatherwax K, Goldman E, Eagle KA, et al. Pacemaker recycling: A notion whose time has come. World J Cardiol. 2017;9(4):296-303. doi: 10.4330/wjc.v9.i4.296 The lack of public health policies for non-infectious diseases, professionals trained to recognize and treat cardiac arrhythmias, as well as access to specialized hospitals and surgical infrastructures are other possible reasons.

There are initiatives that aim to reduce the gap between high-income and low- and middle-income countries, such as Heartbeat International (https://heartbeatsaveslives.org/), an organization that distributes pacemakers close the manufacturer expiration date, which are generously donated by the device industry.66.Mond HG, Mick W, Maniscalco BS. Heartbeat International: Making “poor” hearts beat better. Hear Rhythm. 2009;6(10):1538–40. doi: 10.1016/j.hrthm.2009.07.010

The Project My Heart Your Heart (PMHYH) is a collaboration between US citizens, physicians, and funeral directors, University of Michigan, NEScientific, and World Medical Relief (WMR). WMR is a Detroit-based, non-profit philanthropic organization whose mission is to improve the well-being of the indigent in low- and middle-income countries through the distribution of donated medical supplies, equipment, and medications.77.Baman TS, Romero A, Kirkpatrick JN, Romero J, Lange DC, Sison EO, et al. Safety and Efficacy of Pacemaker Reuse in Underdeveloped Nations. J Am Coll Cardiol. 2009;54(16):1557–8. doi: 10.1016/j.jacc.2009.04.096 The purpose of this collaboration is to determine whether pacemaker reuse is safe and scalable.

Prior to the approval of international clinical trials, the PMHYH spent the first years providing the framework for this idea to be supported by all those it would impact.

In more than 10 years, the PMHYH has already benefited countless patients who received, free of charge, reconditioned pacemakers sent to countries such as the Nigeria, the Philippines, Venezuela, Kenya, and Sierra Leone, among others. The program also provides training and follow-up for local professionals and patients. For more information, visit http://www.myheartyourheart.org.

Reuse of cardiac devices

The concept of reusing pacemakers is not new.11.Baman TS, Eagle KA. Cardiac device reutilization: Is it time to “go green” in underserved countries?. Pacing Clin Electrophysiol. 2011;34(6):651–2. doi: 10.1111/j.1540-8159.2011.03060.x Even though it was never the standard of care, they have already been reused in Brazil and India in the 1980s and 1990s, respectively.88.Araujo H, Melo C. Homenagem Especial – Seymour Furman. Relampa. 2014;27(2):73–5.,99.Panja M, Sarkar C, Kumar S, Kar A, Mitra S, Sinha D, et al. Reuse of Pacemaker. Indian Heart J. 1996;(6):677–80. PMID: 9062017 In the 1990s, Sweden reused around 5% of their pacemakers.1010.European Society of Cardiology. Policy document re-use of devices in cardiology. Eur Hear J. 1998;19(11):1628–31. doi: 10.1053/euhj.1998.1298 Attempts to donate pacemakers taken from the deceased donors to the developing countries by American physicians date back to the 1980s.1111.Hariprasad MK. Reuse of cardiac pacemakers. N Engl J Med. 1982;306(9):551. doi: 10.1056/nejm198203043060923 Reused implantable cardioverter defibrillators (ICDs) and biventricular pacemakers have also been implanted in Africa, but in a smaller scale.1212.Vlay SC. Barriers to pacemaker and ICD recycling. Pacing Clin Electrophysiol. 2018;41(7):681–2. doi: 10.1111/pace.13352,1313.Selvaraj RJ, Sakthivel R, Satheesh S, Pillai AA, Sagnol P, Jouven X, et al. Reuse of pacemakers, defibrillators and cardiac resynchronisation devices. Heart Asia. 2017;9(1):30–3. doi: 10.1136/heartasia-2016-010828

Potential sources of pacemaker donation are: post-mortem and post-extraction. One study showed that more than three thousand devices are removed by American crematoriums, and at least a fifth of those had a battery longer than 4 years. A new device has a battery life of up to 12-14 years, which varies by programming and the device model.1414.Baman TS, Crawford T, Sovitch P, Meier P, Sovitch N, Gakenheimer L, et al. Feasibility of postmortem device acquisition for potential reuse in underserved nations. Hear Rhythm. 2012;9(2):211–4. doi: 10.1016/j.hrthm.2011.09.067 More than 60,000 devices are explanted per year in the United States, and it is estimated that around 20% of these could be reused, creating a total of 10 to 12 thousand devices per year.1515.Gakenheimer L, Romero J, Baman TS, Montgomery D, Smith CA, Oral H, et al. Cardiac implantable electronic device reutilization: Battery life of explanted devices at a tertiary care center. PACE - Pacing Clin Electrophysiol. 2014;37(5):569–75. doi: 10.1111/pace.12321

16.Hughey AB, Baman TS, Eagle KA, Crawford TC. Pacemaker reuse: an initiative to help those in underserved nations in need of life-saving device therapy. Expert Rev Med Devices. 2013;10(5):577–9. doi: 10.1586/17434440.2013.827519
-1717.Baman TS, Kirkpatrick JN, Romero J, Gakenheimer L, Romero A, Lange DC, et al. Pacemaker reuse: An initiative to alleviate the burden of symptomatic bradyarrhythmia in impoverished nations around the world. Circulation. 2010;122(16):1649–56. doi: 10.1161/CIRCULATIONAHA.110.970483

Although donating pacemaker generators is feasible, reusing leads is not feasible. Leads are, in general, difficult to be removed due to the fibrosis process caused over time after their implantation, and their extraction is potentially harmful to them. Even if properly removed, the lead sterilization process is also challenging.1818.Kirkpatrick JN, Papini C, Baman TS, Khota K, Eagle KA, Verdino RJ, et al. Reuse of pacemakers and defibrillators in developing countries: Logistical, legal, and ethical barriers and solutions. Hear Rhythm. 2010;7(11):1623–7. doi: 10.1016/j.hrthm.2010.04.027 However, pacemaker leads are much less expensive than pulse generators, and can usually be purchased by patients in low- and middle-income countries.

Safety

In relation to the use of a reprocessed device, the main concerns are the risk of infection and the risk of device dysfunction (Table 1).

Table 1
– Safety of reprocessed pacemaker

Regarding infection, there is vast literature showing that reconditioned devices are safely reused. According to one report, between 1979 and 1991, forty-two devices were donated and reused in India after being explanted, mostly due to generator infection, and after a 3-year follow-up, only 2 patients had infectious complications.1919.Sethi KK, Bhargava M, Pandit N, Mohan JC, Arora R, Khanna SK, et al. Experience with recycled cardiac pacemakers. Indian Heart J . 1992;44(2):91–3. PMID: 1427938

In the 1980s, in the city of Sao Paulo, 22 devices were reused after chemical decontamination and the use of ethylene oxide. Of those, only one patient had complications due to electromagnetic inhibition of the generator, which happened 2 months after implantation.2020.Costa R, Moreira LF, Pêgo-Fernandes PM, Martinelli Filho MM, Stolf NA, Verginelli G, et al. Reutilização de geradores de marca-passo. Arq Bras Cardiol. 1983;40(5):317–8. PMID: 6651564

In 2011, a meta-analysis on the safety of device reuse, with pacemaker infection as the primary endpoint, included 18 papers published from 1988 to 2008, conducted with a total of 2,270 patients. Device reprocessing methods were not homogeneous. The infection rate was only 1.97%. Of these 18 studies, 5 were controlled with a total of 913 patients included, and showed no difference in infection compared to 6,697 new device implantations.2121.Baman TS, Meier P, Romero J, Gakenheimer L, Kirkpatrick JN, Sovitch P, et al. Safety of pacemaker reuse a meta-analysis with implications for underserved nations. Circ Arrhythmia Electrophysiol. 2011;4(3):318–23. doi: 10.1161/CIRCEP.110.960112

A nonrandomized study of reused ICDs compared 157 patients who received reused devices and 114 patients who received new devices. There was no statistical difference between the groups regarding infections, device malfunction, or unexpected battery depletion.2222.Enache B, Șoșdean R, Macarie R, Dodinot B, Pescariu S. Assessing the safety of implantable cardioverter-defibrillator reuse—A retrospective case-control study. Pacing Clin Electrophysiol. 2019;42(8):1095–8. doi: 10.1111/pace.13742

In 2020, a group from the University of Montreal, together with international collaboration, published an important study in the New England Journal of Medicine which compared 1,051 pacemakers and ICD devices reused in Mexico, the Dominican Republic, Guatemala, and Honduras, with 3,131 new pacemaker implantations performed in Canada. Baseline characteristics of control patients in Canada were adjusted for the study group. The sterilization protocol in that study was not described. No statistical difference was observed in device-related mortality or infection between the groups.2323.Khairy TF, Lupien MA, Nava S, Baez FV, Ovalle FS, Ochoa NE, et al. Infections Associated with Resterilized Pacemakers and Defibrillators. N Engl J Med. 2020;382(19):1823–31. doi: 10.1056/NEJMoa1813876

The same 2011 meta-analysis showed a secondary outcome of the assessment of device malfunction and included seventeen papers with a total of 2,150 reused devices, revealing only 13 device malfunctions, described as “technical errors” (n=5), premature battery depletion (n =1), spontaneous reprogramming (n=1), electromagnetic inhibition (n=1), pectoral muscle inhibition (n=1), screw abnormalities (n=3), and spontaneous ventricular tachycardia (n=1). In four controlled studies of 793 reused pacemakers and 2,200 new implants, there was an increased risk of malfunction in the reused devices.2121.Baman TS, Meier P, Romero J, Gakenheimer L, Kirkpatrick JN, Sovitch P, et al. Safety of pacemaker reuse a meta-analysis with implications for underserved nations. Circ Arrhythmia Electrophysiol. 2011;4(3):318–23. doi: 10.1161/CIRCEP.110.960112

The major disadvantage of a reused device, quite naturally, is a shorter life span when compared with a new device, but this is expected since they have already been used. 2121.Baman TS, Meier P, Romero J, Gakenheimer L, Kirkpatrick JN, Sovitch P, et al. Safety of pacemaker reuse a meta-analysis with implications for underserved nations. Circ Arrhythmia Electrophysiol. 2011;4(3):318–23. doi: 10.1161/CIRCEP.110.960112The PMHYH only reprocesses pacemakers if the battery longevity exceeds four years or has 75% of the total manufactored battery.

Reprocessing technique

There are validated techniques for reprocessing pacemakers, aiming to minimize the risk of infection and dysfunction of the devices to be reimplanted. Here, we describe a validated technique developed by our group at University of Michigan and published in the Journal of American College of Cardiology in 2017 (Figure 1).2424.Crawford TC, Allmendinger C, Snell J, Weatherwax K, Lavan B, Baman TS, et al. Cleaning and Sterilization of Used Cardiac Implantable Electronic Devices With Process Validation: The Next Hurdle in Device Recycling. JACC Clin Electrophysiol. 2017;3(6):623–31. doi: 10.1016/j.jacep.2016.12.007

Figure 1
– My Heart Your Heart lab in Detroit Project.

After being donated by crematoriums or after clinically indicated extractions in hospitals, either due to infection or due to the need for an upgrade, the device passes through the following phases of reprocessing,2424.Crawford TC, Allmendinger C, Snell J, Weatherwax K, Lavan B, Baman TS, et al. Cleaning and Sterilization of Used Cardiac Implantable Electronic Devices With Process Validation: The Next Hurdle in Device Recycling. JACC Clin Electrophysiol. 2017;3(6):623–31. doi: 10.1016/j.jacep.2016.12.007 as shown in Figure 2:

Figure 2
– Device Reprocessing steps.

  1. Visual inspection, if damaged the device is discarded. The device is inspected, and the longevity of the battery is tested.

  2. Cleaning with Lysol disinfectant spray and sorting according to the manufacturer.

  3. Decontamination:
    1. The device is immersed in deionization/reverse osmosis (RO-DI) and Enzol detergent solution for 10 minutes (Advanced Sterilization Products, Irvine, California).

    2. The device is washed with deionized water and then wiped dry.

  4. The generator outputs are then connected to a 500-Ohm test load. The devices are programmed with a 2.5V output with a 1ms pulse width, at a rate of 60. With this programming, the battery is inspected. If the remainder of the battery is less than 4 years, the device is discarded. If longer than 4 years of battery or 75% of the battery, the generator is separated according to the manufacturer.

  5. The generator is configured to storage settings. It is turned off if this function is activated or placed in VVI with 1V output at 0.1ms, with a frequency of 30 and all sensors turned off.

  6. Processing and cleaning:
    1. The screw covers are removed. The screws are removed, washed with distilled water, wiped dry, and sorted by manufacturer.

    2. The screws and generator are placed in a sink with RO-DI and immersed in Enzol’s enzymatic solution for 3 minutes.

    3. The devices are then rubbed four times with a lint-free towel. All devices are brushed with a nylon brush. Connectors are brushed with tube cleaners while immersed in water. The appliance is inspected with a 5x magnifying glass; if debris are found, the appliance is brushed again. If debris are found after two cycles of brushing and cleaning, the device is discarded.

    4. Devices are placed in RO-DI again. After 3 minutes, the sink is drained. The process is repeated three times.

    5. It is washed again with deionized water and then air dried at 35-50°C for 7 hours.

    6. If there is any apparent residue remaining, the device is discarded.

  7. Electrical testing:
    1. The screws are replaced, and a new silicone cover is placed; the device is then dipped four times in medical grade silicone.

  8. The device is re-inspected and programmed for storage in a non-pacing mode, if available, as described above.

  9. Inspection and packaging.

  10. Sterilization
    1. Sterilization using 100% ethylene oxide in a vacuum chamber for 8 hours.

    2. Aeration chamber for 48 hours.

  11. The device is then placed in a sterile area to wait for shipping.

Ethics

Although apparently safe from the infectious standpoint, as described above, some concerns should be taken into consideration: the increased risk of device malfunction and a shorter battery life.

This apparent difference between reprocessed and new devices raises a question: Is it appropriate to reuse devices if they are inferior to new devices? Can pacemakers be exported from high income countries to low- and middle- income countries if they are not allowed for patient use in the donor countries?2525.Aragam KG, Baman TS, Kirkpatrick JN, Goldman EB, Brown AC, Crawford T, et al. The ethics of pacemaker reuse: might the best be the enemy of the good? Heart. 2011;97(24):2005–6. doi: 10.1136/heartjnl-2011-301031

In bioethics, justice is giving everyone what is rightfully theirs, equitably and appropriately for a person. Injustice occurs when a person is denied a good that he/she is entitled to or when it is distributed unequally.2626.Siurana JC. Los principios de la bioética y el surgimiento de una bioética intercultural. Veritas. 2010;22:121–57. doi: 10.4067/S0718-92732010000100006 Therefore, it is not fair to offer a reprocessed pacemaker if there is a possibility of providing a new device, given the longer battery life and the lower risk of malfunction of the new device. However, if these devices are offered to countries that do not have a public policy that guarantees reasonable access to them, would it really be acceptable to deprive them of this treatment, knowing that the absence of therapy for bradycardia can cause significant morbidity and mortality?2727.Hutchison K, Sparrow R. Ethics and the cardiac pacemaker: More than just end-of-life issues. Europace. 2018;20(5):739–46. doi: 10.1093/europace/eux019

Even in countries where the provision of new devices is severely limited, the final decision on the use of reused pacemakers must be made by the patient. The patient must complete an informed consent prior to the procedure. The patient has the right to refuse the refurbished device.2828.Artal R, Rubenfeld S. Ethical issues in research. Best Pract Res Clin Obstet Gynaecol. 2017;43:107–14. doi: 10.1016/j.bpobgyn.2016.12.006

In terms of research, it is still necessary to have the authorization of the local IRBs and a plan for the continuity of the supply of products and monitoring of patients when the research ends.2929.Laman M, Pomat W, Siba P, Betuela I. Ethical challenges in integrating patient-care with clinical research in a resource-limited setting: Perspectives from Papua New Guinea. BMC Med Ethics. 2013;14(1):1. doi: 10.1186/1472-6939-14-29

Manufacturers and reprocessed pacemakers

Device companies have always functioned in a paradigm of single use devices. Device reuse is not sanctioned by the manufacturers for a multitude of reasons. Reprocessed devices do not meet the original specifications and ipso facto cannot be guaranteed to be performed by the original manufacturers. There is a host of legal considerations concerning the reuse of single use devices, which is without precedence. Reusing devices could expose device manufacturers to possible litigation by an injured party. The industry is highly regulated, and all their products are specifically approved in each jurisdiction with clear specifications. It is unlikely that broader application of pacemaker reuse would advance commercial interests of the manufacturers.

Portuguese-speaking countries and the reuse of pacemakers

Although there are several Portuguese-speaking low- and middle-income countries that could be benefited, partnerships with projects that provide these devices have not yet been implemented.

To the best of our knowledge, there are no large organizations in Portuguese-speaking countries whose goal is pacemaker reuse to benefit patients who cannot afford a new device.

Cardiac Stimulation in Portuguese-speaking countries (Table 2).

Table 2
– Portuguese speaking country and device availability. Countries where devices are not available in red, partially available in yellow, and widely available in green

Brazil

Brazil presents rates of pacemaker implants that are much lower than those considered to be high-income, as well as in relation to Latin American countries.3030.Galvao Filho S, Vasconcelos J, Pachon-Mateos J. Registro Brasileiro de Marcapassos (RBM) no Ano de 2003. Dez Anos de RBM. Reblampa. 2004;17(4):165–7.,3131.Pachón-mateos JC, Pereira WL, Duarte W, Junior B, Mateos CP, Indalécio E, et al. RBM - Registro Brasileiro de Marcapassos , Ressincronizadores e Desfibriladores. Relampa. 2013;26(1):39–49. Several factors can justify these differences, such as the difficulties in accessing more specialized facilities, the low number of pacemaker implant centers in some regions of Brazil, and the inadequate stratification of patients who need cardiac implantable electronic devices (CIED).

It is estimated that the public health system has more than 234 specialized cardiovascular centers; however, there are plenty of private hospitals. The lack of CIED has not proven to be a factor present in these specialized centers, and when it does occur, it is mainly due to bureaucratic reasons, related to the delay in carrying out public tenders for the purchase of these devices.

In Brazil, a geographically large country with a broad heterogeneity in access to health care, there are regions where 80% of the medical care is provided by the public health system, while in more developed regions of the country, this number is around 50- 60%. Patients, both from the public and private sectors, have the constitutional right to have access to highly complex procedures and to the implantation of cardiac prostheses guaranteed by law.

Brazilian legislation prohibits the reuse and reprocessing of CIED, such as pacemakers, defibrillators, and CRT devices. ANVISA, a Brazilian regulatory body, equivalent to the FDA in the United States, defines the technical standards in relation to the subject.3232.Saúde. M da, Sanitária, ANVISA. Resolucao - RDC No 2606, de 11 de agosto de 2006. Diário Of da União. 2006;53(9):6297–383.,3333.Ministério da Saúde. Agência Nacional de Vigilância Sanitária. Resolucao - RDC No 156, de 11 de agosto de 2006. Diário Of da União . 2006;4. ANVISA regulated and clarified that some materials used in electrophysiology and the cath lab could be reprocessed, as long as they followed the published normative instructions and were allowed by the manufacturers, who should put on the label, “no reprocessing”, when appropriate.3434.ANVISA. Nota Técnica n° 001/2013/GEMAT/GGTPS/ANVISA. Infor

Several inconsistencies in the labels were found as described by Kuniyoshi, in a work carried out representing SOBRAC (Brazilian Society of Cardiac Arrhythmias).3535.Kuniyoshi RR, Sternick EB, Nadalin E, Hachul DT. Reprocessamento de produtos médicos em eletrofisiologia. Arq Bras Cardiol. 2017;108(2):169–72. doi: 10.5935/abc.20170010 Therefore, materials that did not have a reprocessing ban on the label could be analyzed, as long as a specialized company involved in the process attests to the maintenance of the quality of the reprocessed material. This brought great relief to several cardiology services in the country, mainly at the public level, which usually had already reprocessed some materials and had been banned, making them unfeasible, considering the low prices paid mainly for the public service and the high value of imported materials.3535.Kuniyoshi RR, Sternick EB, Nadalin E, Hachul DT. Reprocessamento de produtos médicos em eletrofisiologia. Arq Bras Cardiol. 2017;108(2):169–72. doi: 10.5935/abc.20170010

The reuse of pacemakers in Brazil was an accepted practice in the 1980s, especially by physicians attending to low-income patients whose medical insurance did not cover such procedures; however, it was never the standard of care.

It is indisputable that a process that leads to cost reduction and greater access to the population of necessary and highly complex treatments are welcome, but in the Brazilian context, the lack of access to specialized implantation centers seems to be the biggest problem that limits the expansion of this treatment and not the lack of CIEDs.

Angola

Angola has only four pacemaker implantation centers, two private and two public, all located in the country’s capital. It has three doctors trained in the implantation of cardiac devices, two cardiologists, and a surgeon.

Pacemakers are implanted in these hospitals; however, only a few CRT devices have been implanted, and this occurred thanks to the support of foreign cardiologists. On average, 30 to 35 devices are implanted in each private center and around 100 in the public hospital a year. In public hospitals, the procedures are paid by the government, but in the Military Hospital, only military staff and their immediate relatives can receive medical care.

There are several difficulties in this activity in Angola, from the lack of material resources in public hospitals to the high cost in private institutions where only people with business agreements and some insurance policies have access to these procedures; this increases the waiting list in public hospitals. There is also a scarcity of trained professionals.

Mozambique

There are only 25 cardiologists, 80% of those are located in the capital. There are only cardiologists in 4 of the 10 provincial capitals, and there is, therefore, a large area with no coverage of the specialty.

The only centers able to place pacemakers are both located in the capital, one is private and the other is public. On average, around 20 to 30 pacemakers a year are placed, most of them in the public hospital for the indigent patients and at no cost. Pacemakers paid by the state only attend to 20% of the current needs, and these could greatly increase with a campaign to detect eligible cases in primary health centers, which was never done to not create an expectation that cannot be consistently met.

The country had a previous experience of using reconditioned pacemakers donated from Spain and had no major issues in acceptance or complications.

Cape Verde

Cape Verde has two central and 4 regional hospitals. Central hospitals are those that offer specialized care. Patients whose needs cannot be met nationally, based on an intergovernmental protocol, are transferred to Portugal. However, this protocol includes an annual quota that places a certain limit on demands. The most common cause of death is stroke, and the most common cause of disability is ischemic heart disease, suggesting that improvement of the cardiovascular care here could have a significant impact on the population.

Since 2016, based on a project for pacemaker implants, local cardiologists have performed CIED implants sporadically, only if the patients assume the cost of the CIED. There is a list of nearly 80 patients awaiting surgery, and it is estimated that 50 patients per year will need pacemakers. Many of those will never be called for implants in Portugal. Thus, there is a need to acquire CIED, as the country already has trained physicians capable of performing these procedures.

St Thomas and Prince

The only cardiology service in the country is located at Hospital Ayres de Menezes, which was founded in 2012; the infrastructure set up offers non-invasive tests, such as transthoracic echocardiograms, exercise testing, and Holter. There is only one cardiologist in the entire country.

Between 2016 and 2021, an average of ten atrioventricular blocks requiring pacemaker implantation per year were diagnosed. Since there is no local structure to implant these devices, these patients are transferred to Portugal. However, the transfer to Portugal is complex, and it can rarely be done urgently. The average waiting time for these patients to leave is approximately 6 months; therefore, many of them end up dying before having the chance to undergo surgery.

Guinea-Bissau

The only cardiology service is the National Hospital. Currently, there is no infrastructure or trained staff to perform CIED surgeries. Patients are transferred to Portugal, but the waiting time can be up to two years.

East-Timor

There are four hospitals in the country with cardiology services, but no cardiac intervention is performed in the country. Patients in need of CIED are transferred to Indonesia, Malaysia, or Singapore. The costs are covered by the government, and patients are transferred within a week.

Conclusions

There is a huge gap between low- and middle-income countries and high-income countries, especially when it involves artificial cardiac stimulation. Pacemaker reprocessing has proven to be safe, ethical, and effective for those who need cardiac implantable electronic devices and cannot afford them. Part of the Portuguese-speaking countries, especially in Africa, need an immediate response that benefits their countless patients who suffer from treatable bradycardias. Each country should, however, conduct a legal and ethical discussion on this matter.

Referências

  • 1
    Baman TS, Eagle KA. Cardiac device reutilization: Is it time to “go green” in underserved countries?. Pacing Clin Electrophysiol. 2011;34(6):651–2. doi: 10.1111/j.1540-8159.2011.03060.x
  • 2
    Ward C, Henderson S, Metcalfe NH. A short history on pacemakers. Int J Cardiol. 2013;169(4):244–8. doi: 10.1016/j.ijcard.2013.08.093
  • 3
    Mond HG, Proclemer A. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: Calendar year 2009 - A world society of Arrhythmia’s project. Pacing Clin Electrophysiol. 2011;34(8):1013–27. doi: 10.1111/j.1540-8159.2011.03150.x
  • 4
    Sinha SK, Sivasambu B, Yenokyan G, Crawford TC, Chrispin J, Eagle KA, et al. Worldwide pacemaker and defibrillator reuse: Systematic review and meta-analysis of contemporary trials. Pacing Clin Electrophysiol. 2018;41(11):1500–7. doi: 10.1111/pace.13488
  • 5
    Runge MW, Baman TS, Davis S, Weatherwax K, Goldman E, Eagle KA, et al. Pacemaker recycling: A notion whose time has come. World J Cardiol. 2017;9(4):296-303. doi: 10.4330/wjc.v9.i4.296
  • 6
    Mond HG, Mick W, Maniscalco BS. Heartbeat International: Making “poor” hearts beat better. Hear Rhythm. 2009;6(10):1538–40. doi: 10.1016/j.hrthm.2009.07.010
  • 7
    Baman TS, Romero A, Kirkpatrick JN, Romero J, Lange DC, Sison EO, et al. Safety and Efficacy of Pacemaker Reuse in Underdeveloped Nations. J Am Coll Cardiol. 2009;54(16):1557–8. doi: 10.1016/j.jacc.2009.04.096
  • 8
    Araujo H, Melo C. Homenagem Especial – Seymour Furman. Relampa. 2014;27(2):73–5.
  • 9
    Panja M, Sarkar C, Kumar S, Kar A, Mitra S, Sinha D, et al. Reuse of Pacemaker. Indian Heart J. 1996;(6):677–80. PMID: 9062017
  • 10
    European Society of Cardiology. Policy document re-use of devices in cardiology. Eur Hear J. 1998;19(11):1628–31. doi: 10.1053/euhj.1998.1298
  • 11
    Hariprasad MK. Reuse of cardiac pacemakers. N Engl J Med. 1982;306(9):551. doi: 10.1056/nejm198203043060923
  • 12
    Vlay SC. Barriers to pacemaker and ICD recycling. Pacing Clin Electrophysiol. 2018;41(7):681–2. doi: 10.1111/pace.13352
  • 13
    Selvaraj RJ, Sakthivel R, Satheesh S, Pillai AA, Sagnol P, Jouven X, et al. Reuse of pacemakers, defibrillators and cardiac resynchronisation devices. Heart Asia. 2017;9(1):30–3. doi: 10.1136/heartasia-2016-010828
  • 14
    Baman TS, Crawford T, Sovitch P, Meier P, Sovitch N, Gakenheimer L, et al. Feasibility of postmortem device acquisition for potential reuse in underserved nations. Hear Rhythm. 2012;9(2):211–4. doi: 10.1016/j.hrthm.2011.09.067
  • 15
    Gakenheimer L, Romero J, Baman TS, Montgomery D, Smith CA, Oral H, et al. Cardiac implantable electronic device reutilization: Battery life of explanted devices at a tertiary care center. PACE - Pacing Clin Electrophysiol. 2014;37(5):569–75. doi: 10.1111/pace.12321
  • 16
    Hughey AB, Baman TS, Eagle KA, Crawford TC. Pacemaker reuse: an initiative to help those in underserved nations in need of life-saving device therapy. Expert Rev Med Devices. 2013;10(5):577–9. doi: 10.1586/17434440.2013.827519
  • 17
    Baman TS, Kirkpatrick JN, Romero J, Gakenheimer L, Romero A, Lange DC, et al. Pacemaker reuse: An initiative to alleviate the burden of symptomatic bradyarrhythmia in impoverished nations around the world. Circulation. 2010;122(16):1649–56. doi: 10.1161/CIRCULATIONAHA.110.970483
  • 18
    Kirkpatrick JN, Papini C, Baman TS, Khota K, Eagle KA, Verdino RJ, et al. Reuse of pacemakers and defibrillators in developing countries: Logistical, legal, and ethical barriers and solutions. Hear Rhythm. 2010;7(11):1623–7. doi: 10.1016/j.hrthm.2010.04.027
  • 19
    Sethi KK, Bhargava M, Pandit N, Mohan JC, Arora R, Khanna SK, et al. Experience with recycled cardiac pacemakers. Indian Heart J . 1992;44(2):91–3. PMID: 1427938
  • 20
    Costa R, Moreira LF, Pêgo-Fernandes PM, Martinelli Filho MM, Stolf NA, Verginelli G, et al. Reutilização de geradores de marca-passo. Arq Bras Cardiol. 1983;40(5):317–8. PMID: 6651564
  • 21
    Baman TS, Meier P, Romero J, Gakenheimer L, Kirkpatrick JN, Sovitch P, et al. Safety of pacemaker reuse a meta-analysis with implications for underserved nations. Circ Arrhythmia Electrophysiol. 2011;4(3):318–23. doi: 10.1161/CIRCEP.110.960112
  • 22
    Enache B, Șoșdean R, Macarie R, Dodinot B, Pescariu S. Assessing the safety of implantable cardioverter-defibrillator reuse—A retrospective case-control study. Pacing Clin Electrophysiol. 2019;42(8):1095–8. doi: 10.1111/pace.13742
  • 23
    Khairy TF, Lupien MA, Nava S, Baez FV, Ovalle FS, Ochoa NE, et al. Infections Associated with Resterilized Pacemakers and Defibrillators. N Engl J Med. 2020;382(19):1823–31. doi: 10.1056/NEJMoa1813876
  • 24
    Crawford TC, Allmendinger C, Snell J, Weatherwax K, Lavan B, Baman TS, et al. Cleaning and Sterilization of Used Cardiac Implantable Electronic Devices With Process Validation: The Next Hurdle in Device Recycling. JACC Clin Electrophysiol. 2017;3(6):623–31. doi: 10.1016/j.jacep.2016.12.007
  • 25
    Aragam KG, Baman TS, Kirkpatrick JN, Goldman EB, Brown AC, Crawford T, et al. The ethics of pacemaker reuse: might the best be the enemy of the good? Heart. 2011;97(24):2005–6. doi: 10.1136/heartjnl-2011-301031
  • 26
    Siurana JC. Los principios de la bioética y el surgimiento de una bioética intercultural. Veritas. 2010;22:121–57. doi: 10.4067/S0718-92732010000100006
  • 27
    Hutchison K, Sparrow R. Ethics and the cardiac pacemaker: More than just end-of-life issues. Europace. 2018;20(5):739–46. doi: 10.1093/europace/eux019
  • 28
    Artal R, Rubenfeld S. Ethical issues in research. Best Pract Res Clin Obstet Gynaecol. 2017;43:107–14. doi: 10.1016/j.bpobgyn.2016.12.006
  • 29
    Laman M, Pomat W, Siba P, Betuela I. Ethical challenges in integrating patient-care with clinical research in a resource-limited setting: Perspectives from Papua New Guinea. BMC Med Ethics. 2013;14(1):1. doi: 10.1186/1472-6939-14-29
  • 30
    Galvao Filho S, Vasconcelos J, Pachon-Mateos J. Registro Brasileiro de Marcapassos (RBM) no Ano de 2003. Dez Anos de RBM. Reblampa. 2004;17(4):165–7.
  • 31
    Pachón-mateos JC, Pereira WL, Duarte W, Junior B, Mateos CP, Indalécio E, et al. RBM - Registro Brasileiro de Marcapassos , Ressincronizadores e Desfibriladores. Relampa. 2013;26(1):39–49.
  • 32
    Saúde. M da, Sanitária, ANVISA. Resolucao - RDC No 2606, de 11 de agosto de 2006. Diário Of da União. 2006;53(9):6297–383.
  • 33
    Ministério da Saúde. Agência Nacional de Vigilância Sanitária. Resolucao - RDC No 156, de 11 de agosto de 2006. Diário Of da União . 2006;4.
  • 34
    ANVISA. Nota Técnica n° 001/2013/GEMAT/GGTPS/ANVISA. Infor
  • 35
    Kuniyoshi RR, Sternick EB, Nadalin E, Hachul DT. Reprocessamento de produtos médicos em eletrofisiologia. Arq Bras Cardiol. 2017;108(2):169–72. doi: 10.5935/abc.20170010
  • Study association
    This study is not associated with any thesis or dissertation work.
  • Sources of funding: There were no external funding sources for this study.