Acessibilidade / Reportar erro

Lactacidemia: métodos de dosagem do ácido lático

Resumo

A critical study of three methods for the determination of lactic acid (EDWARDS, MENDEL & GOLDSCHEIDER, MILLER & MUNTZ) is presented and some modifications are proposed. It was shown t hat more accurate results could be obtained with Edward's technic when an Iena glass filter is connected with the absorption tube. Before the dropping of the permanganate solution it is necessary to pass a current of air through the reaction flask to avoid the oxidation of the non-lactic acid substances which interfere with the reaction. The absorption tube must be maintained at 18°C during the destillation and the titration of the bisulphite binding aldehyde at 4°C. When the sample contains more than 5 mg it is useful to work with greater quantities of the bisulphite. More permanganate is consumed when the lactic acid concentration is higher. The sensivity of the method permits the titration of 0.04 mg to 5 mg of lactic acid in the sample. The calculated error of the method gave 0.018 % and the normal values for blood determined in 20 human cases averaged 10.30 mg per 100 ml (Table VI). MENDEL and GOLDSCHEIDER'S method was modified in the following details: Somogyis deproteinization was performed instead metaphosphoric acid as in the original method; to avoid the evaporation of the acetic aldehyde during the heating time with sulfuric acid a special glass stopped tube is proposed (Fig. 2). The reaction with sulfuric acid and veratrol is performed in an ice bath. Blood proteins precipitants were tried and Somogyi's lattest tecnic showed better results (Table V). Colorimetric readings were done in the PULFRICH photometer using filter S 53 and a 10 mm cup. The method is accurate within an error of 0.23 % and samples of 5 to 70 microg. could be easily determined. Normal values for human blood averaged 10.78 mg per 100 ml. More accurate results were obtained with the technic of MILLER & MUNTZ. Slight modifications were introduced: deproteinization with copper sulfate and sodium tungstate; satured p-hydroxydiphenyl solution according to KOENEMANN which is stable for 5 months when stored in the ice-box. Using the PULFRICH step-photometer the error is 0.17% with samples varying from 0.1 to 10 microg. of lactic acid. The filter employed was S 57 with the 5 mm cup. The method was adapted to 0.1 ml of blood. Normal values for human blood gave an average of 10.58 mg per 100 ml.


ABSTRACT

Lactacidemia: métodos de dosagem do ácido lático

Maria Isabel Mello

A critical study of three methods for the determination of lactic acid (EDWARDS, MENDEL & GOLDSCHEIDER, MILLER & MUNTZ) is presented and some modifications are proposed. It was shown t hat more accurate results could be obtained with Edward's technic when an Iena glass filter is connected with the absorption tube. Before the dropping of the permanganate solution it is necessary to pass a current of air through the reaction flask to avoid the oxidation of the non-lactic acid substances which interfere with the reaction. The absorption tube must be maintained at 18°C during the destillation and the titration of the bisulphite binding aldehyde at 4°C. When the sample contains more than 5 mg it is useful to work with greater quantities of the bisulphite. More permanganate is consumed when the lactic acid concentration is higher. The sensivity of the method permits the titration of 0.04 mg to 5 mg of lactic acid in the sample. The calculated error of the method gave 0.018 % and the normal values for blood determined in 20 human cases averaged 10.30 mg per 100 ml (Table VI). MENDEL and GOLDSCHEIDER'S method was modified in the following details: Somogyis deproteinization was performed instead metaphosphoric acid as in the original method; to avoid the evaporation of the acetic aldehyde during the heating time with sulfuric acid a special glass stopped tube is proposed (Fig. 2). The reaction with sulfuric acid and veratrol is performed in an ice bath. Blood proteins precipitants were tried and Somogyi's lattest tecnic showed better results (Table V). Colorimetric readings were done in the PULFRICH photometer using filter S 53 and a 10 mm cup. The method is accurate within an error of 0.23 % and samples of 5 to 70 microg. could be easily determined. Normal values for human blood averaged 10.78 mg per 100 ml. More accurate results were obtained with the technic of MILLER & MUNTZ. Slight modifications were introduced: deproteinization with copper sulfate and sodium tungstate; satured p-hydroxydiphenyl solution according to KOENEMANN which is stable for 5 months when stored in the ice-box. Using the PULFRICH step-photometer the error is 0.17% with samples varying from 0.1 to 10 microg. of lactic acid. The filter employed was S 57 with the 5 mm cup. The method was adapted to 0.1 ml of blood. Normal values for human blood gave an average of 10.58 mg per 100 ml.

Texto completo disponível apenas em PDF.

Full text available only in PDF format.

Datas de Publicação

  • Publicação nesta coleção
    16 Out 2009
  • Data do Fascículo
    Ago 1943
Instituto Oswaldo Cruz, Ministério da Saúde Av. Brasil, 4365 - Pavilhão Mourisco, Manguinhos, 21040-900 Rio de Janeiro RJ Brazil, Tel.: (55 21) 2562-1222, Fax: (55 21) 2562 1220 - Rio de Janeiro - RJ - Brazil
E-mail: memorias@fiocruz.br