Acessibilidade / Reportar erro

Considerações sôbre a técnica de determinação do "Índice Lipásico Seabra"

Resumo

A detailed study of Seabra's lipasic reagent for the diagnostic of tuberculosis has been made. Substrate. The oily emulsion of cotton seed oil containing gum as dispersing agent, presented a pH variation to the ampoulles examined. In these belonging to the same cartoon as well as in those from different cartoons the values obtained electrometrically ranged from pH 5.8-6.4 (Table I). These variations lead us to presuppose: 1) instability of the oily emulsion in gum; 2) spontaneous hydrolysis of the oil; 3) different batches or technique of the oil extraction, or different sources. Buffer: The same variability observed with substrate was found for the buffer. In CHERRY & CRANDALL's method the buffer is pH 7.0. The saline solution from Seabra's oscillated from pH6.25-6.9 (table II). Titration - end point. A colorimetric comparison between the sample and the blank as suggested by Seabra becomes very difficult. The end point in the presence of serum, when phenolphtalein is used as indicator, is very difficult to compare with the blank containing water. Conclusion. The differences observed in the results when the same serum was used, must be due to the variations observed with Seabra's reagents.


ABSTRACT

Considerações sôbre a técnica de determinação do "Índice Lipásico Seabra"

M. I. Mello1

Laura T. Queiroga1

Instituto Oswaldo Cruz, Rio de Janeiro, Brasil

A detailed study of Seabra's lipasic reagent for the diagnostic of tuberculosis has been made. Substrate. The oily emulsion of cotton seed oil containing gum as dispersing agent, presented a pH variation to the ampoulles examined. In these belonging to the same cartoon as well as in those from different cartoons the values obtained electrometrically ranged from pH 5.8-6.4 (Table I). These variations lead us to presuppose: 1) instability of the oily emulsion in gum; 2) spontaneous hydrolysis of the oil; 3) different batches or technique of the oil extraction, or different sources. Buffer: The same variability observed with substrate was found for the buffer. In CHERRY & CRANDALL's method the buffer is pH 7.0. The saline solution from Seabra's oscillated from pH6.25-6.9 (table II). Titration - end point. A colorimetric comparison between the sample and the blank as suggested by Seabra becomes very difficult. The end point in the presence of serum, when phenolphtalein is used as indicator, is very difficult to compare with the blank containing water. Conclusion. The differences observed in the results when the same serum was used, must be due to the variations observed with Seabra's reagents.

Texto completo disponível apenas em PDF.

Full text available only in PDF format.

Datas de Publicação

  • Publicação nesta coleção
    01 Out 2009
  • Data do Fascículo
    Dez 1955
Instituto Oswaldo Cruz, Ministério da Saúde Av. Brasil, 4365 - Pavilhão Mourisco, Manguinhos, 21040-900 Rio de Janeiro RJ Brazil, Tel.: (55 21) 2562-1222, Fax: (55 21) 2562 1220 - Rio de Janeiro - RJ - Brazil
E-mail: memorias@fiocruz.br