Abstract

The simultaneous determination of two or more active components in pharmaceutical preparations, without previous chemical separation, is a common analytical problem. Published works describe the determination of AZT and 3TC separately, as raw material or in different pharmaceutical preparations. In this work, a method using UV spectroscopy and multivariate calibration is described for the simultaneous measurement of 3TC and AZT in fixed dose combinations. The methodology was validated and applied to determine the AZT+3TC contents in tablets from five different manufacturers, as well as their dissolution profile. The results obtained employing the proposed methodology was similar to methods using first derivative technique and HPLC.

multivariate calibration; lamivudine (3TC); zidovudine (AZT)


NOTA TÉCNICA

Simultaneous spectrophotometric determination of lamivudine and zidovudine in fixed dose combinations using multivariate calibration

Severino Grangeiro Jr.I; Miracy M. AlbuquerqueI; Davi P. SantanaI; Maria Fernanda PimentelII; Reniere H. da SilvaII; Simone S. SimõesIII, * * e-mail: simoes.simone@gmail.com

IDepartamento de Ciências Farmacêuticas, Universidade Federal de Pernambuco, 50740-540 Recife - PE, Brasil

IIDepartamento de Engenharia Química, Universidade Federal de Pernambuco, 50740-540 Recife - PE, Brasil

IIILaboratório Farmacêutico do Estado de Pernambuco, 58051-320 Recife - PE, Brasil

ABSTRACT

The simultaneous determination of two or more active components in pharmaceutical preparations, without previous chemical separation, is a common analytical problem. Published works describe the determination of AZT and 3TC separately, as raw material or in different pharmaceutical preparations. In this work, a method using UV spectroscopy and multivariate calibration is described for the simultaneous measurement of 3TC and AZT in fixed dose combinations. The methodology was validated and applied to determine the AZT+3TC contents in tablets from five different manufacturers, as well as their dissolution profile. The results obtained employing the proposed methodology was similar to methods using first derivative technique and HPLC.

Keywords: multivariate calibration; lamivudine (3TC); zidovudine (AZT).

INTRODUCTION

Lamivudine (3TC) and zidovudine (AZT) are nucleoside analogues and potent selective inhibitors of the HIV-1 and HIV-2 viruses. 3TC has shown to be synergistic to AZT, inhibiting the replication of HIV in cellular cultures.1 3TC induces its own viral resistance, causing the AZT to become sensitive again in a reverse transcriptase in many patients who present a process of resistance associated with AZT through mutation, weakening the virulence and the HIV capacity for viral replication and decreasing the genetic diversification of this enzyme.2 Because AZT+3TC is a combination of drugs used to treat a disease that is difficult to treat, the drugs produced for this purpose require producing laboratories to use methodologies capable of monitoring the stages of production, ensuring a high quality product.

The simultaneous determination of two or more active components in different pharmaceutical preparations, without previous chemical separation, is a common analytical problem.3 Official monographs, such as The Brazilian Pharmacopoeia and The United States Pharmacopoeia,4,5 describe the determination of AZT and 3TC separately, either as raw material or in different pharmaceutical preparations. No official monograph has been found that describes how this association in tablets can be determined.4-9 At the present, high performance liquid chromatography - HLPC is the technique commonly employed in the pharmaceutical industry to monitor the quality of the end products and the processes, especially when the product has an association of active compounds. A method using HPLC with ultraviolet (UV) detection for the determination of AZT+3TC has recently been described.10 HPLC with Uv detection and mass spectrometry has also been employed to determine the association of AZT+3TC in biological fluids.11-14 These techniques are, however, expensive, laborious, present high reagent consumption, and require many analytical manipulations. They also generate a number of chemical residues that must be treated properly. Consequently, the development of simpler and cheaper methods for the quality control of processes and end products is important. Uv-vis spectrophotometry can be used in pharmaceutical laboratories for a number of applications.15-21 Few works have been found using this technique to determine antiretroviral fixed dose combinations. Uslu et al. developed methods for the determination of AZT+3TC in binary mixtures,22 using first derivate and first derivative of the ratiospectra Uv-spectrophotometry, as well as high performance liquid chromatography. Methanol has been employed as a solvent for standard solutions and preparation of samples. These methods were validated using synthetic mixtures and tablets from only one pharmaceutical industry. Kapoor et al. have employed derivative spectrometry for the simultaneous determination of Estavudina (d4T) e lamivudine (3TC) antiretroviral in fixed dose combinations.23

Multivariate calibration has also been used to solve the problems of overlapping Uv spectra in mixtures of two or more components and when there is interference from the formulation matrix.24-28 Inverse calibration methods such as Partial Least Square (PLS) are widely used. In these methods the pure analyte spectrum is not required for modeling.

In this work a method using Uv-spectrophotometry and multivariate calibration was developed for the simultaneous determination of lamivudine and zidovudine in fixed dose combinations. The methodology was applied to determine the content of AZT+3TC in tablets, as well as the dissolution profile of the tablets, from five different manufacturers. This methodology was validated and the results obtained were compared with methods using spectrophotometric first derivative and HPLC.

EXPERIMENTAL

Standard, reagents and solutions

All 3TC and AZT stock solutions (concentrations of 250 mg L-1 3TC and 500 mg L-1 AZT) were prepared from reference standards produced by the United States Pharmacopoeia.5 The solutions were prepared with dilutions using ultra-pure water. AZT+3TC tablets with nominal concentrations of 300 e 150 mg, respectively, were kindly provided by five pharmaceutical manufactors: LAFEPE, Farmanguinhos, IQUEGO, FURP e GlaxoSmithKline. In this work, these manufacturers will be denominated (randomly) A, B, C, D and E. The placebo was formulated according to the procedure used by the LAFEPE in the production of their commercial tablets, and was composed of the following: amide, amide glycolate, microcrystalline cellulose, polivinilpirrolidone, silicon dioxide, and magnesium stearate. In all the analyses, the commercial samples were prepared by diluting them with ultrapure water. Twenty tablets from each manufacturer were weighed, finely powdered and then the solutions were prepared with 3TC and AZT concentrations of 7.5 e 15 mg L-1, respectively.

Multivariate calibration and validation set

For the construction of multivariate calibration models, binary mixtures of AZT +3 TC were produced in the laboratory covering a range of 80 and 120% of the nominal value, according to the ANVISA guide (Resolution - RE n º 899, of May 29, 2003) requirements. This guide contains the rules for validation of analytical and bionalytical methods for the quantitative determination of analyte in raw materials or in dosage forms.

The SPXY algorithm (Sample set Partioning based on joint X-y distances algorithm) was used to select the samples for the calibration and prediction sets.29 22 samples were selected for the calibration set (?). 6 samples were selected to predict the AZT concentration (?) and 6 samples to predict the 3TC concentration (O). Figure 1 shows the distribution of samples into the calibration and prediction sets of samples; note that two samples were selected to predict the content of both 3CT and AZT. Thirty-nine commercial samples were also used in the validation set.


Partial least square regression (PLS) was employed to build the multivariate calibration models. All the computations were carried out using Unscrambler® 9.8 (CAMO Process A.S) and MVC1 software.30

UV-VIS spectra

A double beam UV-vis spectrometer, Shimadzu®, model UV-2401 PC, using a scanning speed of 8.3 nm s-1 and a quartz cuvette (10 mm optical path), was employed to acquire UV-vis spectra, in the spectral range of 200 to 300 nm. These spectra were used to build the calibration models using derivative spectrometry and PLS.

Reference method

The content of AZT + 3 TC in the samples was determined by a method based on HPLC and validated according to ICH and RE in 899/2003.10,31 The values obtained were used to build calibration models and to assess the predictive capacity of the models.

Reference analyses were performed employing a chromatographic system, Shimadzu®, consisting of binary pumps LC-10 ADvp, a UV/vis detector SPD 10 Avp in 270 nm, a CTO-10ASvp furnace (30 ºC), a SCL-10ADvp controller system and a SIL-10ADvp auto injector. The stationary phase was a C18 column 125 x 4.6 cm, with a porosity of 5 x 10-3 mm and a mobile phase ammonium acetate (J.T.Baker®) buffer of pH 5.4 and methanol, Merck® (65:35). The flow was 1.0 mL min-1 and injection volume 20 x 10-3 mL. Chromatograms were obtained and analyzed using Class-VP software.

Dissolution profile

The dissolution profile of the samples was determined using a dilutor, model VK 7010, equipped with a dissolution sampling station (model VK 8000), both from Vankel®. Eight vessels, each containing 900 mL of ultrapure water, rotated at 50 rpm with an apparatus paddle, at a temperature of 37 ± 0.5 ºC, were employed in this assay. 2 mL aliquots were collected at time intervals of 3, 6, 10, 15, 20 and 30 min. Each aliquot was transferred to a volumetric flask of 50 mL, so that the theoretical concentrations were 13.33 mg L-1 of AZT and 6.66 mg L-1 of 3TC.

Validation

The methods were validated according to the procedures required by the Specific Brazilian Resolution RE nº 899 based on the ICH and IUPAC guide.32

RESULTS AND DISCUSSION

UV spectra

Figure 2 shows the aqueous solutions UV Spectra of (A) binary mixture (15 mg L-1 of AZT and 7.5 mg L-1 of 3TC); (B) commercial tablet, (C) AZT 15 mg L-1; (D) 3TC 7.5 mg L-1 and (E) placebo. Observing the placebo (E), binary mixture (A) and commercial tablet (B) spectra, there is no evidence of placebo interference in the range of 230 to 300 nm. The calibration set, thus, could be composed of binary mixtures only. A strong band overlap between AZT and 3TC can be seen.


Derivative spectroscopy

The analysis using UV-derivative was carried out based on the work by Uslu et al.. However, water was used as solvent instead of methanol due to its low cost and because it is not harmful to the environment. As a result of the molar absorptivity change, the absorption peaks were different.

Different scan speeds and Savitzky-Golay windows were evaluated. The best conditions obtained were: spectral range of 200 to 300 nm, with a scan 8.3 nm s-1 and δλ equal to 1.0 nm. The Savitzky-Golay windows with 11 and 17 points were selected for the first and second derivatives, respectively. For lamivudine, the values of D1, amplitudes were measured at 267.3 nm (zero-crossing of zidovudine). D1 amplitudes were measured at 249.3 nm (zero-crossing of lamivudine) to determine zidovudine. In the second derivative spectra, the amplitudes were measured at 250.7 nm (zero-crossing of AZT) to determine 3TC, and 239.0 and 229.0 nm (zero-crossing of 3TC), to determine AZT.

Spectra of pure component solutions were acquired to build the analytical curves. Linearity was also evaluated employing analytical curves with 8 concentration levels and three authentic replicates, using ANOVA and the lack of fit test (at 95% confidence level).31 The linear ranges for D1 method were: 0.60 to 50.0 and 0.12 to 100 mg L-1, for 3TC and AZT, respectively. For D2 method the linear ranges were: for λ = 250.7 nm, 0.34 to 50 mg L-1 (3TC); for λ = 229 nm, 0.33 to 0.10 mg L-1 (AZT) and for λ = 239 nm, 1.66 to 0.10 mg L-1 (AZT). The validation parameters are presented in Table 1. The specificity of the method was evaluated and no interference from the excipients was found when the method was applied to placebo samples. The accuracy, precision, detection and quantification limits were validated according to the requirements of Brazilian Resolution RE nº 899.33 The variables tested for robustness were: ultra-pure/deionized water; sonication time; filtered and non-filtered samples; and stability (0, 24 e 48 h). No significant variation, at 95% confidence level, was observed.

Multivariate calibration

Partial least squares models were built using the UV spectra of the calibration mixtures, the AZT and 3TC content of which had been previously determined by the HPLC reference method. A full cross validation was employed to select the number of PLS factors. A spectral range from 200 to 300 nm was employed first. When the model was applied to predict the AZT+3TC content in commercial tablets, however, high RMSEP values were obtained, as expected, as can be seen in Figure 2. This problem was attributed to interference from one of the excipients (polivinilpirrolidone), which absorbs in the range of 200-230 nm. This region was excluded and then new models were built using the range of 230 to 300 nm. The figures of merit for univariate methods are well established in the ICH guidelines.31 They are not clearly defined, however, for multivariate calibration methods, although the literature indicates various strategies.32,34,35 In this work, similar to Blanco,36 validation was performed to evaluate these parameters: sensibility, selectivity, limit of detection, robustness, accuracy and precision. In the robustness test the same variables were evaluated as in the derivative methods. No significant variation, at 95% confidence level, as can be seen in Table 2.

The calibration and validation parameters are presented in Table 3. The number of latent variables (VL) used in PLS model was determined based on the lower RMSECV, using the Haaland and Tomas criterion. Two latent variables were selected for both models, which is in accordance with the number of APIs. Sensitivity (SEN), selectivity (SEL), and limit of detection (LOD) were calculated based on the NAS theory, using the MVC1 algorithm.31 For multivariate calibration, the selectivity indicates the part of the total signal that is not lost due to spectral overlap. The sensitivity measures the changes in response as a function of the concentration of a particular the sensitivity measures the changes in response as a function of the concentration of a particular analyte.31,32 Considering the values presented in Tables 2 and 3, the methods were validated, as recommended by the Specific Brazilian Resolution RE nº 899 based on ICH and IUPAC guide.32

Determination of AZT + 3TC in fixed dose combinations of tablets from different manufacturers

After being validated, three methods (first and second derivative spectrometry, UV-VIS/PLS and HPLC) were employed to determine the content of AZT+3TC in tablets (nominal concentrations of 150 mg of AZT and 300 mg of 3TC) produced by 5 different manufacturers in Brazil. These pharmaceutical industries are denominated here as A, B, C, D and E. Eight replicates were performed. The results are presented in Table 4. There was no significant difference between the results of AZT+3TC content when using derivative and PLS methods and the reference HPLC method, at a 95% confidence level. The RSD are also similar.

Dissolution profile

A dissolution profile is useful to select formulations during the development of the pharmacotechnique process; to evaluate stability; to optimize formulations, to investigate the effects of variations in products that are in use, as well as to present a tool for lot quality control monitoring. This assay is also employed to determine the similarity between a generic formulation and its reference product.37 The derivative and PLS methods were also evaluated and compared with the reference HPLC method in the dissolution profile test. Dissolution tests were carried out on tablets produced by the five different manufacturers. To compare methods, a t-test was applied at each point of the dissolution profile. No statistically significant differences (at 95% confidence level) were found among the results of the methods. This result demonstrates that the derivative and PLS methods may be applied to an extended range of concentrations. Figure 3 shows the profile for laboratory A, as an example. For all methods, the similarity of the results is evident. Results from the first sampling time showed a large variability due to the technological aspects inherent to the manufacturing process of tablets. Among these, we may mention the variability of the thickness of the coating layer, particle size and compression force applied. Moreover, irregularities in sampling position may interfere in the results. These factors are most critical in the first sampling time by the fact that it is realized in 3 min, a time not long enough for the total disintegration of the tablet.


CONCLUSION

In this work, the spectrophotometric multivariate calibration method was validated and successfully applied to the simultaneous determination of lamivudine and zidovudine in fixed dose combinations for tablets from different manufacturers. Multivariate calibration method produced results similar to the reference HPLC method but was simpler, faster, and cheaper to use. The results of the multivariate method were also similar to the derivative methods. The zero-crossing derivative methods, however, may produce a considerable loss of accuracy and sensitivity because the measurements were taken at a very critical wavelength.22 Thus, the multivariate calibration method could be considered advantageous in relation to the derivative method. The use of multivariate calibration methods associated with spectroscopic methods, as an alternative to traditional univariate methods, has the advantage of simultaneous determination, which saves labor and considerably reduces the cost of the experiment (in terms of reagent consumption, time and waste generation). They can be very useful in product development and for process monitoring.

Despite these advantages, multivariate methods are not acceptable as an official method for the analysis of the final product. One of the reasons for this could be attributed to the need of a representative calibration set containing samples with a concentration range larger than the nominal content of the tablets produced by the industry. This is a practical critical aspect when near infrared spectroscopy is employed. In this work, using UV spectroscopy, as there is no evidence of placebo interference in the range of 230 to 300 nm, the calibration set was composed only by binary mixtures covering ± 20% of the nominal content.

Recebido em 12/3/10; aceito em 17/11/10; publicado na web em 25/2/11

  • 1
    Physicians' Desk Reference, 42nd ed.; N.J.: Medical Economics Co.: New Jersey, 1988.
  • 2. Moore, K. H.; Shaw, S.; Laurent, A. L.; Lloyd, P.; Duncan, B.; Morris, D. M.; O'mara, M. J.; Pakes, G. E.; J. Clin. Pharmacol. 1999, 39, 593.
  • 3. Özgür; M. Ü.; Alpdogan, G.; Koyuncu, I.; Anal. Lett. 2002, 35, 721.
  • 4
    Farmacopéia Brasileira, IV ed.; Atheneu: São Paulo, 2002.
  • 5
    The United States Pharmacopeia, 31th ed.; NF-26, Rockville, 2008.
  • 6. British Pharmacopoeia, The Stationery Office: London, 2008.
  • 7
    Farmacopéia Portuguesa, 8ª ed.; Infarmed: Lisboa, 2005.
  • 8
    Farmacopea de Los Estados Unidos Mexicanos, 8ª ed.; FEUM: Mexico, 2004.
  • 9
    The Japanese Pharmacopoeia, available at http://jpdb.nihs.go.jp/jp14e/contents.html, accessed April 2008.
  • 10. Beck, R. C. R; Cardoso, S. G.; Athayde, M. L.; Codevilla, C.; Kreutz, O.; Dalmora, S. L.; Quim. Nova 2007, 30, 1225.
  • 11. Wissen, C. P. W. G. M. V.; Aernoutse, R. E.; Burgern, D. M.; J. Chromatogr., B: Anal. Technol. Biomed. Life Sci. 2005, 816, 121.
  • 12. Fan, B.; Stewart, J. T.; J. Pharm. Biomed. Anal. 2002, 28, 903.
  • 13. Nascimento, J. E.; Magalhães, N. S. S.; Ribeiro, P. A.; Alves, A. J.; Braz. J. Pharm. Sci. 2004, 40, 60.
  • 14. Kenney, K. B.; Wring, S. A.; Carr, R. M.; Wells, G. N.; Dunn, J. A.; J. Pharm. Biom. Anal. 2000, 22, 967.
  • 15. Karpiska, J.; Sokól, A.; Skoczylas, M.; Spectrochim. Acta, Part A 2008, 71, 1562.
  • 16. Benamor, M.; Aguerssif, N.; Spectrochim. Acta, Part A 2008, 69, 676
  • 17. Hadad, G. M.; El-Gindy, A.; Mahmoud, W. M. M.; Spectrochim. Acta, Part A 2008, 70, 655.
  • 18. El-Yazbi, F. A.; Hammud, H. H.; Sulaf, A. A.; Spectrochim. Acta, Part A 2007, 68, 275.
  • 19. Busaranon, K.; Suntornsuk, W.; Suntornsuk, L.; J. Pharm. Biom. Anal. 2006, 41, 158.
  • 20. Shehata, M. A. M.; El Sabed, M. A; El Tarras, M. F.; El Bardicy, M. G.; J. Pharm. Biom. Anal. 2005, 38, 72.
  • 21. Garcia, P. L.; Santoro, M. I. R. M.; Kedor-Hackman, E. R. M.; Singh, A. K.; J. Pharm. Biom. Anal. 2005, 39, 764.
  • 22. Uslu, B.; Ozkan, S. A.; Anal. Chim. Acta 2002, 466, 175.
  • 23. Kapoor, N.; Khandavilli, S.; Panchagnula, R.; J. Pharm. Biom. Anal. 2006, 41, 761.
  • 24. Markopoulou, C. K.; Malliou, E. T.; Koundourellis, J. E.; Il Farmaco 2004, 59, 627.
  • 25. Yongnian, N.; Zhengbao, Q.; Kokot, S.; Chem. Intell. Lab. Syst. 2006, 82, 241.
  • 26. Khoshayand, M. R.; Abdollahi, H.; Shariatpanahi, M.; Saadatfard, A.; Mohammadia, A.; Spectrochim. Acta, Part A 2008, 70, 491.
  • 27. Metwally, F. H.; Spectrochim. Acta, Part A 2008, 69, 343.
  • 28. Nian, N. Y.; Xiao, W. Q.; Chin. Chem. Lett. 2008, 19, 981.
  • 29. Galvão, R. K. H.; Araujo, M. C. U.; Jose, G. E.; Ponte, M. J. C.; Silva, E. C.; Saldanha, T. C. B.; Talanta 2005, 67, 736.
  • 30. Olivieri, A. C.; Goicoechea, H. C.; Iñón, F. A.; Chem. Intell. Lab. Syst 2004, 73, 189.
  • 31
    ICH Guidelines: Q2(R1) Text on Validation of Analytical Procedures; at http://www.ich.org/LOB/media/MEDIA417.pdf, accessed May 2009.
  • 32. Olivieri, A. C.; Faber, N. M.; Ferré, J.; Boqué, R.; Kalivas, J. H.; Mark, H.; Pure Appl. Chem. 2006, 78, 661.
  • 33. Brasil. Resolução RE nº899 de 29/5/2003; Diário Oficial da União, Brasília, DF, 02/06/2003, seção 1 - Agência Nacional de Vigilância Sanitária (ANVISA) aprova o Guia para validação de métodos analíticos e bioanalíticos.
  • 34. Metwally, F. H.; Spectrochim. Acta, Part A 2008, 69, 343.
  • 35. Braga, J. W. B.; Poppi, R. J.; Quim. Nova 2004, 27, 1004.
  • 36. Blanco, M.; Eustaquio, A.; González, J. M.; Serrano, D.; J. Pharm. Biom. Anal. 2000, 22, 139.
  • 37. Abdou, H. M.; Dissolution, Biavailabilty e Bioequivalence, Mack Publishing Company: Easton, 1989.
  • *
    e-mail: