Experimental acrylonitrile butadiene styrene and polyamide evisceration implant: a rabbit clinical and histopathology study

Estudo clínico e histopatológico em coelhos eviscerados com utilização de implantes de poliamida e acrilonitrila butadieno estireno

ABSTRACT

The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.

Keywords:
rabbits; ocular prosthesis; polymers

RESUMO

Avaliou-se a macroscopia, a microestrutura, a resposta clínica e histopatológica de implantes de acrilonitrila butadieno estireno (ABS) e poliamida em coelhos submetidos à evisceração. Para o estudo experimental, os implantes foram elaborados por meio de prototipagem rápida, com 12mm de diâmetro, pesados e tiveram suas superfícies avaliadas macroscopicamente e por microscopia eletrônica de varredura. Adicionalmente, foi realizado ensaio de compressão para determinar a força necessária para fraturar os implantes. Após a evisceração do olho esquerdo, nove coelhos da raça Nova Zelândia receberam implantes de poliamida e nove outros receberam implantes de ABS. Os animais foram avaliados diariamente nos primeiros 15 dias após a cirurgia e a cada sete dias até o fim do período experimental (90 dias). Avaliação histopatológica foi realizada aos 15, 45 e 90 dias após a cirurgia. Os implantes de ABS pesaram 0,44g, e os de poliamida 0,61g. A microscopia eletrônica de varredura demonstrou que os implantes de ABS eram formados por microporos equidistantes, enquanto os de poliamida apresentavam microporos de vários tamanhos. A força necessária para fraturar os implantes de ABS foi de 14.39±0.60 Mpa, enquanto para os de poliamida foi de 16.80±1.05Mpa. Quinze dias após a cirurgia, foi observada infiltração fibrovascular centrípeta. Os implantes podem ser utilizados para correção de cavidades anoftálmicas por se mostrarem inertes, biocompatíveis e permitirem a infiltração tecidual.

Palavras-chave:
coelho; prótese ocular; polímero

INTRODUCTION

Patients with congenital or acquired eye disorders may need surgical procedures to remove the eyeball or its contents. Loss of eye causes an aesthetically unacceptable situation. Loss of volume, which is generally replaced with an orbital implant and overlying prosthetic eye, is related. It is extremely important for the artificial eye patient to maintain a natural, normal appearing prosthetic eye (Wang et al., 2012WANG, J.; ZHANG, H.; CHEN, W.; LI, G. The psychosocial benefits of secondary hydroxyapatite orbital implant insertion and prosthesis wearing for patients with anophthalmia Ophthal. Plast. Reconstr. Surg., v.28, p.324-327, 2012.).

Several biomaterials have been used for improving the appearance after surgical procedures such as evisceration, enucleation or exenteration and among these, polymethylmethacrylate, glass, silicon, porous polyethylene and hydroxyapatite (Chuah et al., 2004CHUAH, C.T.; CHEE, S.P.; FONG, K.S. et al. Integrated hydroxyapatite implant and non-integrated implants in enucleated Asian patients. Ann. Acad. Med. Singapore, v.33, p.477-483, 2004.; Tabatabee et al., 2011; Baino et al., 2014BAINO, F.; PERERO, S.; FERRARIS, S. et al. Biomaterials for orbital implants and ocular prostheses: overview and future prospects. Acta Biomater., v.10, p.1064-1088, 2014.) have been used. With the creation of interconnection channels polymethylmethacrylate implants, tissue infiltration was observed in non-integrable implants (Oriá et al., 2011ORIÁ, A.P.; COSTA NETO, J.M.; LIMA, A.E.S. et al. Comportamento do polimetilmetacrilato munido com canais de interconexão como implantes orbitários em coelhos. In: CONGRESSO BRASILEIRO DA ANCLIVEPA, 32., 2011, Goiânia. Anais... Goiânia: ANCLIVEPA, 2011. (Resumo expandido).). Recently, new articles pointed out that changes in the structure of the implants enable tissue infiltration (Miyashita et al., 2013MIYASHITA, D.; CHAHUD, F.; BARROS da SILVA, G.E. et al. Tissue ingrowth into perforated polymethylmethacrylate orbital implants: An experimental study. Ophthal. Plast. Reconstr. Surg., v.29, p.160-163, 2013.; Gomes Junior et al., 2015; Oriá et al., 2016)

Despite the diversity of available implants, no ideal one has been defined, therefore, researches to try to find new biomaterials, which fulfill the characteristics of an ideal biomaterial, such as presenting low cost, minimal inflammatory reaction, be capable of sterilization, light and resistance to infection continues (Jordan et al., 2002JORDAN, D.R.; BROWNSTEIN, S.; GILBERG, S. et al. Investigation of bioresorbable orbital implant. Ophthal. Plast. Reconstr. Surg., v.18, p.342-348, 2002.). The polyamide is considered to be inert and has been used for decades in the form of surgical thread, which causes minimal inflammatory reaction with contact to body tissue (Rahal et al., 1997RAHAL, S.C.; ROCHA, N.S.; FIGUEIREDO, L.A.; IAMAGUTI, P. Estudo comparativo da reações teciduais produzidas pela "linha de pesca" (poliamida) e fio de náilon cirúrgico. Cienc. Rural, v.28, p.89-93, 1997.; Puricelli et al., 2011PURICELLI, E.; NÁCUL, A.M.; PONZONI, D. et al. Implante intramuscular de polimetilmetacrilato (PMMA) 30%, associado a veículo não-proteico: estudo experimental em ratos. Rev. Bras. Cir. Plast., v.26, p.385-389, 2011.). Acrylonitrile butadiene styrene already has a wide application in the electronics industry, automobile and household appliances (Díez-Pascual and Gascón, 2013) but even being a low-cost polymer there are no reports of its use in the health area. With the possibility to manipulate polymers to create a strong, porous structure, the aim of our study was to evaluate spherical acrylonitrile butadiene styrene and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well.

MATERIALS AND METHODS

The research protocols were approved by the Ethics Committee on Animal Use of the School of Veterinary Medicine and Animal Science, Federal University of Bahia, under protocol number 34/2013.

The implants were prepared by the Division of Tridimensional Technology of the Renato Archer Center for Information Technology (Campinas, São Paulo, Brazil). The ABS (ABS P400 ABS Model(r), Califórnia, USA) spheres were prepared using fusion deposition machining (FDM) technology (Vantage i, Minnesota, USA). The polyamide (Duraform PA(r), Califórnia, USA) spheres were prepared by selective laser sintering (SLS) technology (Sinterstation(tm) 2000(r), Califórnia, USA). The implants were weighed and the external surfaces were evaluated. In addition, attempts were made to break them between the thumb and forefinger (the pinch test), and the ease with which they could be penetrated with a 25x7 needle was ascertained. The force required to fracture the implant was determined by a tensile test with crosshead speed of 1 mm/min, and the fracture site was examined by scanning electron microscopy obtained at 15kV with several magnifications (Gomes Junior et al., 2015).

After mechanical cleaning with compressed air, implants were individually packaged and sterilized using ethylene oxide (SETE, Bahia, Brazil). To this end, 18 New Zealand rabbits (Oryctolagus cuniculus), males, weighing between 1.9 and 2.4kg, obtained from a rabbit breeding center (Federal University of Recôncavo of Bahia) were used. All the surgical procedures were conducted under isoflurane (Isoflurane(r), Cristália, São Paulo, Brazil) general anaesthesia. The left eye of each animal was used for evisceration. After retrobulbar block with 2% lidocaine (without epinephrine) (Xylestesin(r), Cristália, São Paulo, Brazil), the evisceration was performed by the same team. After dissection of the conjunctiva and Tenon's capsule, a 360° keratectomy was performed and four scleral fragments were prepared, each containing a straight extraocular muscle (dorsal, ventral, lateral and medial). Hemostasis was achieved by compression with gauze, and after immersion in saline, the ABS or polyamide implant was inserted (nine animals each). The dorsal and ventral fragments were sutured and then the lateral and medial fragments with single 6-0 polypropylene sutures (Prolene(r), Ethicon, São Paulo, Brazil), so as to cover the implant, followed by suturing Tenon's capsule and conjunctiva with 7-0 polypropylene suture.

Immediately after surgery the rabbits received ketoprofen (Ketofen(r), Merial, São Paulo, Brazil) at a dose of 1mg/kg, subcutaneously, and then at regular 24-hour intervals for the first three postoperative days; enrofloxacin (Flotril(r), Schering Plough, São Paulo, Brazil) at a dose of 0.025mg/kg, subcutaneously, single dose. To provide postoperative comfort to the animals, 2mg/kg morphine (Dimorf(r), Cristália, São Paulo, Brazil) was administered subcutaneously at regular 8-hour intervals for the first three postoperative days. Topical antibiotic (Ciloxan(r), Alcon, São Paulo, Brazil) was administered for two weeks every six hours.

Clinical evaluation was performed daily for 15 days and thereafter at intervals of 15 days until the end of the experimental period, always by the same professional. Ocular discharge and chemosis were classified as absent, mild, moderate or severe and the ocular surface was cleaned with gauze and saline after each evaluation to remove secretions. The pain was characterized as present or absent. For this evaluation, the animals were conditioned to allow periocular manipulation during the adjustment period, where after 30 days, the eyelids constrict on handling, but were easily opened with the thumb and index finger to expose the ocular surface. Bleeding, suture dehiscence, and exposure or extrusion of the implants were also assessed.

At each time, 15, 45 and 90 days, three animals from each group were euthanized with an overdose of barbiturate (sodium thiopental) and the left orbit exenterated. The exenterated contents of the left orbit of the rabbits were fixed in 10% buffered formalin for 48 to 96h. The capsule surrounding the implant was evaluated macroscopically and the spheres were then sectioned in half with a No. 23 scalpel blade for macroscopic evaluation of tissue integration. Since tissue infiltration could not be confirmed by histopathology because the spheres were rigid and not susceptible to cutting with a microtome, the spheres were subjected to HE staining to assess tissue infiltration better. It should be noted that when spheres were stained with HE and then washed in water, they did not retain the stain. For the histopathological processing, the tissue cover was included in paraffin using routine techniques and stained with hematoxylin and eosin (HE).

RESULTS

The mean weight of the ABS implants was 0.44±0.01g, while the polyamide weighed 0.61±0.01g. ABS implants were yellowish, solid, porous and rough while the polyamide ones appeared white, solid, compact and rugged (Figure 1).

Figure 1
Macrophotographs of the ABS (A) and polyamide (B) implants. Note the irregular appearance of the outer surface of the spheres.

The pinch test and attempt to penetrate the implants with a 25x7 needle were negative for both implants. The scanning electron microscopy confirmed the findings observed macroscopically in ABS implants, while despite having a compact appearance, polyamide implants proved to be porous. The outer surface of the ABS implants was formed by slightly irregular filaments, regularly aligned, parallel and transverse, with the formation of 200-μm micropores (Figure 2A). The polyamide implants had numerous irregular-sized microgranules of 15 to 120μm and the formation of micropores of various sizes between 9 and 117μm (Figure 2B). In the compression test, some ABS spheres became deformed and were excluded from the analysis. The mean pressure was 14.39334±0.59936 Mpa for ABS spheres and 16.79984±1.0504Mpa for polyamide spheres. Scanning electron microscopy of the inner surface showed a filamentous and compact appearance of the ABS filaments as well as an organized structure of 200μm micropores and the fracture area showed disruption of ABS filaments without damage to the rest of the structure (Figure 2B). With regard to the polyamide implant, the inner surface was similar to the outer surface, and in the fracture area, there was disaggregation of microgranules without altering their interaction (Figure 2D).

Figure 2
Scanning electron microscopy of the area of the outer and inner (fracture area) surface of ABS (A, B) and polyamide (C, D) implants. ABS implants (magnification X50 (A) and X40 (B)). Polyamide implants (magnification X50 (C) and X300 (D)).

There were no signs of infection, hemorrhage, suture dehiscence, exposure or extrusion of implants. Eye pain was noted in the immediate postoperative period characterized by intense blepharospasm in the first 24h. After this period, the animals kept eyelids open, but during the following 48h, they showed discomfort on handling, characterized by greater difficulty in opening the eyelids when compared to the non-operated eye. After this period, the animals did not show discomfort on touching the orbital region and allowed easy opening of the eyelids and exposure of the surgically treated region. Chemosis was observed in all animals in the immediate postoperative period, where it was intense for five days, becoming mild at 15 days and absent in subsequent evaluations. A slight eye discharge of mucoid consistency, whitish, nonpurulent, was observed in the immediate postoperative period and persisted throughout the study. Implant mobility was observed but was not quantified since there was no standard for the species.

In the macroscopic examination, all samples showed a fine capsule strongly adhered to both implants. Part of the capsule could not be removed and remained adhered to the implant surface. When assessing the inner surface of the implants microscopically after sectioning, tissue was observed permeating the micropores. The cell type could not be determined. At 15 days, tissue infiltration was seen heading to the center of the ABS and polyamide implants. At 45 days the tissue partially filled the polyamide spheres and completely filled the ABS spheres. At 90 days, polyamide spheres were completely filled (Figure 3). The filled tissue implants could be more easily visualized after HE staining (Figure 3).

Figure 3
Macrophotographs of ABS (A-D) and polyamide (E-H) implants after sectioning in half for evaluation of tissue infiltration. Note centripetal tissue infiltration in implants, with darker appearance at 15 days (A and E), 45 days (B and F) and 90 days (C and G) after surgery. The spheres were stained with HE to observe the tissue infiltration with greater clarity (D and H). Note the presence of tissue capsule adhered to the implant surface (arrow).

The fragments obtained from the sclera, surrounding the implants in both groups showed similar features upon histopathologic examination. All scleral fragments showed a few inflammatory cells (lymphocytes) 15 days after surgery. At 45 and 90 days, there was no evidence of cells related to inflammatory processes (Figure 4). Evidence of infection or foreign body reaction was not observed in any of the slides.

Figure 4
Photomicrographs of the scleral fragments of rabbits after removal of the ABS implant 15 (A) and 90 days after surgery (B) and polyamide implant 15 (C) and 90 days after surgery (D) Note the absence of inflammatory reaction in the area adjacent to the implants (*) (HE, X50). Magnification (HE, X400).

DISCUSSION

Prototyping techniques are employed in surgical planning, in the manufacture of implants and prosthetics and in the preparation of customized implants (Aherwar et al., 2014AHERWAR, A.; SINGH, A.; PATNAIK, A. A review paper on rapid prototyping and rapid tooling techniques for fabrication of prosthetic socket. In: BARTOLO, P.J.; LEMOS A.C.S.; PEREIRA, A.M.H. et al. (Eds). High value manufacturing: advanced research in virtual and rapid prototyping. London: Taylor & Francis Group, 2014. p.45-353.). However, to our knowledge, there is only reference to a patented resin (FullCure 720(r)) for making orbital implants, which was evaluated in the form of sphere in rabbits subjected to evisceration. The implants proved to be biocompatible but did not integrate (Kormann et al., 2013KORMANN, R.B.; MOREIRA, H.; CRESCENTE, G.; FOGGIATTO, J.A. Estudo experimental da biocompatibilidade de novo material para implante orbitário. Arq. Bras. Oftal., v.76, p.141-146, 2013.).

Polymer materials are indispensable in many fields, where they are used, for example, in packages and various medical devices. However, for medical applications, it is necessary to evaluate the possibility of sterilizing the biomaterial and determining its biocompatibility (Sehlinger et al., 2015SEHLINGER, A.; OCHSENREITHER, K.; BARTNICK, N.; MEIER, MAR. Potentially biocompatible polyacrylamides derived by the Ugi four-component reaction. Eur. Polym. J., v.65, p.313-324, 2015.). According to the manufacturer of polyamide (Duraform(r)), this compound is certified for use "in vivo." However, for ABS (ABS P400(r)), there have not been any "in vivo" studies. Besides the question of certification, there is no information in the literature regarding the tissue reaction caused by these materials in the form in which they are designed. Furthermore, the manufacturer indicates that the polyamide should have biological behavior tests conducted after the preparation of a given device for medical use. We were unable to find any published studies on the use of implants produced through rapid prototyping composed of polyamide and ABS, in the medical field. Additionally, there is no information in the literature on the way they are designed and on the proposed objective. As main strengths, it should be noted that the materials are easy to purchase and can be produced on an industrial scale.

The first ocular implants were composed of metal or glass which made them heavy and caused discomfort to patients. Therefore, the weight of the implants is a factor that must be considered when choosing a new biomaterial. The polyamide and ABS implants in this study showed weights of 0.60 and 0.44g, respectively. These values are lower than those of synthetic hydroxyapatite and coral implants weighing 0.62 and 0.79g, and there is no report in the literature of complications related to the weight of these implants (Jordan et al., 2000JORDAN, D.R.; MAWN, L.A.; BROWNSTEIN, S. et al. The bioceramic orbital implant: A new generation of porous implants. Ophthal. Plast. Reconstr. Surg., v.16, p.347-355, 2000.).

Non-porous implants such as polymethylmethacrylate are commonly used due to their low cost and ease of sterilization (Yoon et al., 2008YOON, J.S.; LEW, H.; KIM, S.J.; LEE, S.Y. Exposure rate of hydroxyapatite orbital implants a 15-year experience of 802 cases. Ophthalmology, v.115, p.566-572, 2008. ), but like double-setting alpha-tricalcium phosphate cement, they do not allow tissue infiltration because of insufficient pores on the surface (Yoon et al., 2008; Baino et al., 2014BAINO, F.; PERERO, S.; FERRARIS, S. et al. Biomaterials for orbital implants and ocular prostheses: overview and future prospects. Acta Biomater., v.10, p.1064-1088, 2014.). In such implants, the creation of interconnecting channels allows for tissue infiltration (Miyashita et al., 2013MIYASHITA, D.; CHAHUD, F.; BARROS da SILVA, G.E. et al. Tissue ingrowth into perforated polymethylmethacrylate orbital implants: An experimental study. Ophthal. Plast. Reconstr. Surg., v.29, p.160-163, 2013.; Gomes Junior et al., 2015; Oriá et al., 2016ORIÁ, A.P.; SOUZA, M.R.; DÓREA NETO, F.A. et al. Polymethylmethacrylate orbital implants with interconnecting channels. A retrospective study following enucleation in dogs and cats. Vet. Ophthal., v.19, n.2, p.102-9, 2016.). Porosity of the biomaterial appears to exert a greater influence on tissue response obtained. Tissue infiltration occurs in micropores larger than 5µm, but macrogranular materials with pores of 150-700µm foster fast fibrovascular growth (Son et al., 2012SON, J.; KIM, C.; YANG, J. Comparison of experimental porous silicone implants and porous silicone implants. Graefs Arch. Clin. Exper. Ophthalmol., v.250, p.879-885, 2012.), which was observed since ABS implants allowed earlier tissue infiltration than did those of polyamide. Considering that the adherence between the capsule and implant and tissue infiltration to the center of the spheres was observed macroscopically, it can be confirmed that the 200µm micropores were sufficient to enable tissue infiltration. The implants composed of the ABS show communication between pores, which allows similar tissue infiltration as porous implants of synthetic hydroxyapatite or porous coral and polyethylene (Yoon et al., 2008; Tabatabaee et al., 2011TABATABAEE, Z.; MAZLOUMI, M.; RAJABI, M.T. et al. Comparison of the exposure rate of wrapped hydroxyapatite (Bio-eye) versus unwrapped porous polyethylene (Medpor) orbital implants in enucleated patients. Ophthal. Plast. Reconstr. Surg., v.27, p.114-118, 2011.; Baino et al., 2014).

Like other studies involving orbital implants in rabbits, we did not observe complications such as exposure, extrusion, infection or suture dehiscence (Tabatabaee et al., 2011TABATABAEE, Z.; MAZLOUMI, M.; RAJABI, M.T. et al. Comparison of the exposure rate of wrapped hydroxyapatite (Bio-eye) versus unwrapped porous polyethylene (Medpor) orbital implants in enucleated patients. Ophthal. Plast. Reconstr. Surg., v.27, p.114-118, 2011.; Toft et al., 2012TOFT, P.B.; RASMUSSEN, M.L.; PRAUSE, J.U. One-stage explant-implant procedure of exposed porous orbital implants. Acta Ophthalmol., v.90, p.210-214, 2012.; Kormann et al., 2013KORMANN, R.B.; MOREIRA, H.; CRESCENTE, G.; FOGGIATTO, J.A. Estudo experimental da biocompatibilidade de novo material para implante orbitário. Arq. Bras. Oftal., v.76, p.141-146, 2013.; Miyashita et al., 2013MIYASHITA, D.; CHAHUD, F.; BARROS da SILVA, G.E. et al. Tissue ingrowth into perforated polymethylmethacrylate orbital implants: An experimental study. Ophthal. Plast. Reconstr. Surg., v.29, p.160-163, 2013.; Gomes Junior et al., 2015). Eye pain or discomfort was noted in the first three days in the postoperative period and might have been related to surgical manipulation. Chemosis was noted for a few days after surgery and might have been associated with the antiseptic agent employed and surgical manipulation (Miyashita et al., 2013). Eye discharge of whitish mucoid consistency, has already been described by other authors when performing evisceration in rabbits (Toft et al., 2012; Kormann et al., 2013; Miyashita et al., 2013) and it occurred in a discreet manner in the present study.

All foreign material in contact with body tissue causes a tissue reaction. Typically, a fibrovascular capsule is formed to isolate the foreign body from other tissues (Puriceli et al., 2011) and in general, the thicker the capsule, the greater the tissue reaction (Brandão et al., 2013BRANDÃO, S.M.; SCHELLINI, A.S.; PADOVANI, C.R. et al. Análise da biocompatibilidade de cones de biovidro e biovitrocerâmico (Biosilicato(r)) em cavidade eviscerada de coelho. Rev. Bras. Oftalmol., v.72, p.21-25, 2013.). Polyamide sutures are considered inert, and when placed in contact with the body tissue, a thin capsule is formed around them for the purpose of isolating them from the host tissues (Rahal et al., 1997RAHAL, S.C.; ROCHA, N.S.; FIGUEIREDO, L.A.; IAMAGUTI, P. Estudo comparativo da reações teciduais produzidas pela "linha de pesca" (poliamida) e fio de náilon cirúrgico. Cienc. Rural, v.28, p.89-93, 1997.). Thus, we expected a minimal inflammatory reaction and that the polyamide implant would be surrounded by a thin tissue capsule. Similarly, the reaction to the ABS implant was similar to that with the polyamide implant.

The inflammatory reaction usually lasts a few weeks after surgery and the cellular content of the inflammatory process varies widely according to the biomaterial used. In this study, with both implants, there was sparse mononuclear infiltrate, particularly lymphocytes, which are found in the majority of inflammatory responses to ocular implants. We expected that there would be a minimal inflammatory reaction and that the polyamide implants would be surrounded by a fine tissue capsule in a manner similar to suture, since it is a material considered inert (Rahal et al., 1997RAHAL, S.C.; ROCHA, N.S.; FIGUEIREDO, L.A.; IAMAGUTI, P. Estudo comparativo da reações teciduais produzidas pela "linha de pesca" (poliamida) e fio de náilon cirúrgico. Cienc. Rural, v.28, p.89-93, 1997.). The ABS implants showed a similar tissue reaction as polyamide implants.

In the literature, a more intense inflammatory reaction is noted in the first 15 days, which decreases over time (Miyashita et al., 2013MIYASHITA, D.; CHAHUD, F.; BARROS da SILVA, G.E. et al. Tissue ingrowth into perforated polymethylmethacrylate orbital implants: An experimental study. Ophthal. Plast. Reconstr. Surg., v.29, p.160-163, 2013.; Gomes Junior et al., 2015) however, both the ABS and polyamide evoked only a minimal inflammatory response by 15 days. At 45 days, there were no inflammatory cells, indicating good acceptance of biomaterials, since hydroxyapatite and porous polyethylene implants, considered the best for facial space filling, may show the accumulation of lymphocytes and granulocytes for more than six months after surgery (Toft et al., 2012TOFT, P.B.; RASMUSSEN, M.L.; PRAUSE, J.U. One-stage explant-implant procedure of exposed porous orbital implants. Acta Ophthalmol., v.90, p.210-214, 2012.). If the inflammatory reaction or the capsule showed exuberance at 90 days that would be evidence that the tissue reaction caused by the implant was still in progress and a longer period of evaluation would be necessary. This has been observed with cones of bioglass and bioglass ceramic and double-setting alpha-tricalcium phosphate cement that at 90 days still showed inflammation (Brandão et al., 2013BRANDÃO, S.M.; SCHELLINI, A.S.; PADOVANI, C.R. et al. Análise da biocompatibilidade de cones de biovidro e biovitrocerâmico (Biosilicato(r)) em cavidade eviscerada de coelho. Rev. Bras. Oftalmol., v.72, p.21-25, 2013.; Gomes Junior et al., 2015).

CONCLUSION

ABS and polyamide implants are inert and biocompatible and allow tissue integration; they can be used in the filling of anophthalmic cavities.

ACKNOWLEDGMENTS

We thank the Coordination for the Improvement of Higher Education (CAPES) and the Research Support Foundation of the State of Bahia (FAPESB DCR0019/2015) for financial support.

REFERENCES

  • AHERWAR, A.; SINGH, A.; PATNAIK, A. A review paper on rapid prototyping and rapid tooling techniques for fabrication of prosthetic socket. In: BARTOLO, P.J.; LEMOS A.C.S.; PEREIRA, A.M.H. et al. (Eds). High value manufacturing: advanced research in virtual and rapid prototyping. London: Taylor & Francis Group, 2014. p.45-353.
  • BAINO, F.; PERERO, S.; FERRARIS, S. et al. Biomaterials for orbital implants and ocular prostheses: overview and future prospects. Acta Biomater., v.10, p.1064-1088, 2014.
  • BRANDÃO, S.M.; SCHELLINI, A.S.; PADOVANI, C.R. et al. Análise da biocompatibilidade de cones de biovidro e biovitrocerâmico (Biosilicato(r)) em cavidade eviscerada de coelho. Rev. Bras. Oftalmol., v.72, p.21-25, 2013.
  • CHUAH, C.T.; CHEE, S.P.; FONG, K.S. et al. Integrated hydroxyapatite implant and non-integrated implants in enucleated Asian patients. Ann. Acad. Med. Singapore, v.33, p.477-483, 2004.
  • DÍEZ-PASCUAL, A.M.; GASCÓN, D. Carbon nanotube buckypaper reinforced acrylonitrile−butadiene−styrene composites for electronic applications. ACS Appl. Mater. Interfaces, v.5, p.1210-1219, 2013.
  • GOMES JUNIOR, D.C.; ORIÁ, A.P.; DÓREA NETO, F.A. et al. Double-setting alpha-tricalcium phosphate cement provided with interconection channels in rabbits after enucleation: A potential implant for the anophthalmic socket. Arq. Bras. Med. Vet. Zootec, v.67, p.119-124, 2015.
  • JORDAN, D.R.; MAWN, L.A.; BROWNSTEIN, S. et al. The bioceramic orbital implant: A new generation of porous implants. Ophthal. Plast. Reconstr. Surg., v.16, p.347-355, 2000.
  • JORDAN, D.R.; BROWNSTEIN, S.; GILBERG, S. et al. Investigation of bioresorbable orbital implant. Ophthal. Plast. Reconstr. Surg., v.18, p.342-348, 2002.
  • KORMANN, R.B.; MOREIRA, H.; CRESCENTE, G.; FOGGIATTO, J.A. Estudo experimental da biocompatibilidade de novo material para implante orbitário. Arq. Bras. Oftal., v.76, p.141-146, 2013.
  • MIYASHITA, D.; CHAHUD, F.; BARROS da SILVA, G.E. et al. Tissue ingrowth into perforated polymethylmethacrylate orbital implants: An experimental study. Ophthal. Plast. Reconstr. Surg., v.29, p.160-163, 2013.
  • ORIÁ, A.P.; COSTA NETO, J.M.; LIMA, A.E.S. et al. Comportamento do polimetilmetacrilato munido com canais de interconexão como implantes orbitários em coelhos. In: CONGRESSO BRASILEIRO DA ANCLIVEPA, 32., 2011, Goiânia. Anais... Goiânia: ANCLIVEPA, 2011. (Resumo expandido).
  • ORIÁ, A.P.; SOUZA, M.R.; DÓREA NETO, F.A. et al. Polymethylmethacrylate orbital implants with interconnecting channels. A retrospective study following enucleation in dogs and cats. Vet. Ophthal., v.19, n.2, p.102-9, 2016.
  • RAHAL, S.C.; ROCHA, N.S.; FIGUEIREDO, L.A.; IAMAGUTI, P. Estudo comparativo da reações teciduais produzidas pela "linha de pesca" (poliamida) e fio de náilon cirúrgico. Cienc. Rural, v.28, p.89-93, 1997.
  • SEHLINGER, A.; OCHSENREITHER, K.; BARTNICK, N.; MEIER, MAR. Potentially biocompatible polyacrylamides derived by the Ugi four-component reaction. Eur. Polym. J., v.65, p.313-324, 2015.
  • SON, J.; KIM, C.; YANG, J. Comparison of experimental porous silicone implants and porous silicone implants. Graefs Arch. Clin. Exper. Ophthalmol., v.250, p.879-885, 2012.
  • TABATABAEE, Z.; MAZLOUMI, M.; RAJABI, M.T. et al. Comparison of the exposure rate of wrapped hydroxyapatite (Bio-eye) versus unwrapped porous polyethylene (Medpor) orbital implants in enucleated patients. Ophthal. Plast. Reconstr. Surg., v.27, p.114-118, 2011.
  • TOFT, P.B.; RASMUSSEN, M.L.; PRAUSE, J.U. One-stage explant-implant procedure of exposed porous orbital implants. Acta Ophthalmol., v.90, p.210-214, 2012.
  • PURICELLI, E.; NÁCUL, A.M.; PONZONI, D. et al. Implante intramuscular de polimetilmetacrilato (PMMA) 30%, associado a veículo não-proteico: estudo experimental em ratos. Rev. Bras. Cir. Plast., v.26, p.385-389, 2011.
  • WANG, J.; ZHANG, H.; CHEN, W.; LI, G. The psychosocial benefits of secondary hydroxyapatite orbital implant insertion and prosthesis wearing for patients with anophthalmia Ophthal. Plast. Reconstr. Surg., v.28, p.324-327, 2012.
  • YOON, J.S.; LEW, H.; KIM, S.J.; LEE, S.Y. Exposure rate of hydroxyapatite orbital implants a 15-year experience of 802 cases. Ophthalmology, v.115, p.566-572, 2008.

Publication Dates

  • Publication in this collection
    Sep-Oct 2016

History

  • Received
    18 Aug 2015
  • Accepted
    10 Dec 2015
Universidade Federal de Minas Gerais, Escola de Veterinária Caixa Postal 567, 30123-970 Belo Horizonte MG - Brazil, Tel.: (55 31) 3409-2041, Tel.: (55 31) 3409-2042 - Belo Horizonte - MG - Brazil
E-mail: abmvz.artigo@gmail.com