Acessibilidade / Reportar erro

Randomized clinical trial on percutaneous minimally invasive osteosynthesis of fractures of the distal extremity of the radius Please cite this article as: Aita MA, Vieira Ferreira CH, Schneider Ibanez D, Saraiva Marquez R, Hideki Ikeuti D, Toledo Mota R, et al. Ensaio clínico randomizado de osteossíntese percutânea e minimamente invasiva das fraturas da extremidade distal do rádio. Rev Bras Ortop. 2014;49:218-226. , ☆☆ ☆☆ Work performed by the Hand and Microsurgery Group, ABC School of Medicine, Santo André, SP, Brazil.

Abstracts

OBJECTIVES:

the purpose of this study was to compare the postoperative radiological and clinical outcomes with minimally invasive percutaneous osteosynthesis using three implants: volar locking plate, intramedullary nail system and nonbridging external fixator for distal radius fractures.

METHODS:

forty-eight patients (A group, 16; B group 16; C group 16) underwent minimally invasive percutaneous osteosynthesis of reductible and unstable displaced (Type IIB by Rayhack Classification) distal radius fractures. In B group intramedullary nail system was used, in A group the patients were treated with volar locking plate and in C group the patients were treated by nonbridging external fixator from January 2011 to December 2012. The mean follow-up period was 12 months. Radiologic parameters, range of motion, grip strength, and disability of the arm, shoulder, and hand score were evaluated at each examination (3rd and 6th week, and 12th months). The visual analog scale of wrist pain and complications were assessed at the final follow-up.

RESULTS:

the groups did not differ significantly in radiological outcomes after 12 months, but the clinical results, VAS scale and dash score in group A (volar locking plate) and B (nail intramedullary) were statistically significantly better than that of C group (nonbridging external fixator). One patient underwent an osteosynthesis with nail intramedullary and another with external fixator (C group) developed persistent pain near the site of the superficial radial nerve because of the distal's screw and pins, respectively.

CONCLUSION:

in clinical parameters, significant differences in outcomes were found between groups A and B after six weeks versus C group.

Fractures of the radius; Internal fracture fixation; Bone plate


OBJETIVOS:

comparar o resultado clínico funcional dos pacientes com diagnóstico de fratura com desvio, redutível e instável da extremidade distal do rádio submetidos ao tratamento cirúrgico pela técnica de osteossíntese percutânea e minimamente invasiva com o uso de três tipos de implante: placa volar bloqueada, haste intramedular bloqueada e fixador externo. Comparar os resultados quanto à melhoria da qualidade de vida pelo questionário Dash e ao tempo de retorno ao trabalho.

MÉTODOS:

divididos em três grupos (A, placa - 16; B, haste - 16; C, fixador externo - 16), 48 pacientes foram submetidos ao tratamento cirúrgico da fratura da extremidade distal do rádio, redutível e instável, classificação Rayhack (Tipo IIB), pelo método minimamente invasivo, com três tipos de implante: haste intramedular bloqueada, placa volar bloqueada e fixador externo radio-radial. Estudo feito de janeiro de 2011 a dezembro de 2012. O tempo de seguimento foi de 12 meses. Parâmetros radiográficos, dor (escala VAS), medida do arco de movimento, força de preensão palmar e o questionário Dash foram avaliados na terceira e sexta semana e no sexto mês de pós-operatório.

RESULTADOS:

numa análise vertical dos valores apresentados, observamos uma melhoria estatística significativa em todos os parâmetros clínicos analisados no estudo, nos três grupos. Em relação à análise horizontal, ou seja, na comparação dos grupos entre si, não houve diferenças estatísticas significativas quanto aos parâmetros radiográficos após o 12° mês de seguimento. O grau de força de preensão palmar, a medida do arco de movimento, VAS e Dash apresentaram, na terceira e sexta semana de pós-operatório, valores estatísticos significativos superiores nos grupos A e B. Um paciente do grupo B apresentou dor no punho, por provável proximidade do parafuso com o primeiro túnel extensor, que foi removido; e outro do C apresentou dor no punho, no trajeto do ramo sensitivo do nervo radial, pela presença do pino de Schantz.

CONCLUSÃO:

a técnica minimamente invasiva é eficaz e segura, com melhoria clínica e funcional em todos os momentos do estudo. Ambos os três implantes são estáveis. Há superioridade estatística significativa dos resultados clínico-funcionais (grau de força e arco de movimento, Dash e VAS) até a sexta semana, para os grupos A (placa) e B (haste). No fim de 12 meses não há diferenças estatísticas significativas entre os grupos

Fraturas do rádio; Fixação interna de fraturas; Placas ósseas


Introduction

Fractures that affect the distal radius are among the most frequent fractures of the upper limbs and account for 74.5% of the fractures of the forearm, i.e. an incidence of 1:10,000 people.11. Alffram PA, Bauer GC. Epidemiology of fractures of the forearm. A biomechanical investigation of bone strength. J Bone Joint Surg Am. 1962;44:105-14. There is greater incidence in the dominant arm.22. Angelini LC, Grecco MAS. Tratamento da pseudartrose do terço distal do rádio. Acta Ortop Bras. 2005;13(2):95-9.

Currently, fractures of the distal extremity of the radius are regarded as complex, with a prognosis depending on the type of fracture and/or the treatment used. In seeking better clinical and functional results, surgical methods are increasingly indicated, and there has been great evolution in the implants developed for the distal extremity of the radius. Nonetheless, there is still space for classical conservative treatment, particularly for fractures without displacement.33. Fernandez DL, Palmer AK. Fractures of the distal radius. In: Green DP, Hotchkiss RN, Pederson WC, editors. Green's operative hand surgery. 4th ed. New York: Churchill Livingstone; 1999. p. 925-85.

Surgical methods have also evolved, with minimally invasive osteosynthesis techniques and approaches toward soft tissues that are more biological, i.e. less aggressive toward the covering of soft tissues.44. Wei DH, Poolman RW, Bhandari M, Wolfe VM, Rosenwasser MP. External fixation versus internal fixation for unstable distal radius fractures: a systematic review and meta-analysis of comparative clinical trials. J Orthop Trauma. 2012;26(7):386-94.

The implants that are most often used in our setting for treating these fractures are Kirschner wires, volar locking plates and transarticular external fixators.44. Wei DH, Poolman RW, Bhandari M, Wolfe VM, Rosenwasser MP. External fixation versus internal fixation for unstable distal radius fractures: a systematic review and meta-analysis of comparative clinical trials. J Orthop Trauma. 2012;26(7):386-94.

Stabilization of fractures of the distal extremity of the radius, using Kirschner wires placed separately or using the transarticular external fixation method, does not allow early rehabilitation of the wrist. Kirschner wires are a method with minimal osteosynthesis and require plaster-cast immobilization throughout the treatment, while external fixation using Schanz pins placed in the second or third metacarpals blocks flexion-extension of the wrist.

However, these and new implants developed for fractures of the distal extremity of the radius, such as intramedullary locking nails55. Nishiwaki M, Tazaki K, Shimizu H, Ilyas AM. Prospective study of distal radial fractures treated with an intramedullary nail. J Bone Joint Surg Am. 2011;93(15):1436-41. and nonbridging external fixators can be used percutaneously.66. Sen MK, Strauss N, Harvey EJ. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg. 2008;12(1):2-6.

The possibility of indirect open reduction of such fractures, i.e. without viewing the focus of the fracture, allows ever-earlier rehabilitation, given that the implants and the surgical approach are also less aggressive and more stable.66. Sen MK, Strauss N, Harvey EJ. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg. 2008;12(1):2-6.

Since there are no statistically significant results in the studies so far published with regard to surgical treatment of these fractures, and these systematic reviews and meta-analyses77. Handoll HH, Madhok R. Withdrawn: surgical interventions for treating distal radial fractures in adults. Cochrane Database Syst Rev. 2009;(3):CD003209. state that it is necessary to conduct studies with better qualitative evidence, we decided to carry out this study using a minimally invasive technique with three different implants: intramedullary locking nail, volar locking plate and nonbridging external fixator. All the implants allow the same rehabilitation protocol, with early mobilization recommended immediately after the surgery.

Objectives

To compare the functional clinical results (palm grip strength, wrist range of motion and pain) among patients with a diagnosis of an unstable but reducible displaced extra-articular fracture (type IIB of Rayhack's classification)88. Rayhack JM. The history and evolution of percutaneous pinning of displaced distal radius fractures. Orthop Clin North Am. 1993;24(2):287-300. of the distal extremity of the radius, who underwent surgical treatment by means of a minimally invasive percutaneous osteosynthesis technique, using three different implants: volar locking plate, intramedullary locking nail and external fixator.

To compare the results with regard to quality-of-life improvement through applying the DASH questionnaire.99. Jester A, Harth A, Wind G, Germann G, Sauerbier M. Disabilities of the arm, shoulder and hand (Dash) questionnaire: determining functional activity profiles in patients with upper extremity disorders. J Hand Surg Br. 2005;30(1):23-8.

Material and methods

Between January 2011 and December 2012, 100 patients who presented at the outpatient clinics of the Hand and Microsurgery Group, ABC School of Medicine, with a diagnosis of fracture of the distal extremity of the radius were evaluated. Forty-eight of these patients were included in the study and underwent physical examination and posteroanterior (PA) and lateral (L) radiographic examinations.

The inclusion criteria were that the patients should be adults aged 18-65 years, of either sex, with a clinical and imaging diagnosis of this fracture (type IIB), and needed to fill out the voluntary free and informed consent statement and the protocol of conflicts of interest, as specified by the Research Ethics Committee (Appendix A Anex 1. Voluntary free and informed consent statement Study: a randomized comparative study using external fixators, percutaneous volar plates and intramedullary nails to surgically treat fractures of the distal extremity of the radius. Principal investigator: Walter Yoshinori Fukushima; Medical Registration Number (CRM): 109969-SP. Address: Rua Morvan Dias de Figueiredo, 155, apto 12, CEP 09732-580, São Bernardo do Campo, São Paulo. Discipline of Diseases of the Locomotor System (Orthopedics and Traumatology), ABC School of Medicine, Avenida Lauro Gomes, 2000, Bairro Vila Sacadura Cabral, Santo André – SP, CEP 09060-870, Brazil. Tel: +55 011 4993 5400. This study was assessed and approved by the institution’s Research Ethics Committee on July 4, 2007 (registration no. 160/2007). This committee is a body that has the aim of protecting your well-being. It is responsible for assessing and following up the ethical issues of all studies involving human beings so that the dignity, rights, safety and well-being of the research subjects are ensured. If you have any doubts and/or questions about your rights as a participant in this study, or if you are dissatisfied with the way in which the study is being conducted, you can get in touch with the Research Ethics Committee of the ABC School of Medicine at the following address: Avenida Príncipe de Gales, 821, 1st floor, CEPES Building, Santo André, SP, or by telephone: (11)-4993-5453. The hours of attendance are from Monday to Friday from 07:00 to 17:00. Name of subject or person with legal responsibility:________________ No. of identity document:_____________ Sex: M ()/F () Date of birth: ____/___ /___ Telephone: () Address:_________ I, Mr/Ms______________; declare for legal purposes that I am being guided in relation to all the risks, discomforts and benefits that result directly or indirectly (causal link) from the procedure(s) that I am undergoing. My participation as a patient, and/or the person responsible, is voluntary and I am aware that I am receiving the best treatment options for the disease or condition that I have, in its current state. I am aware that this participation is for a period of five years. The treatment offered, i.e. surgical treatment with a volar plate for angular stability, a nonbridging external fixator or an intramedullary locking nail, has the aim of achieving adequate stabilization of the fracture of the distal extremity of the radius. It has been discussed and is appropriate and adequate, such that it provides improvement of the present conditions. These surgical procedures will be carried out in patients with a diagnosis of fracturing of the distal radius, comprising the abovementioned surgical treatment. I am aware that complications relating to the disease may occur, with procedures equivalent to the complexity of the general clinical picture, local state and hospital conditions. The surgery will be accompanied by anesthetic procedures and possible complications such as anaphylaxis, drug interactions, cardiorespiratory arrest and various allergies. There are risks of implant loosening and surgical site infection. Additional procedures with medical indications due to severe risks will be performed as described in the literature, if these are essential formy benefit, for treatment in viewof emergency situations that might occur, and no non-routine procedures will be performed. If the use of intensive care units, semi-intensive care unit, blood transfusion or special examinations after the procedure(s) becomes necessary, these will be implemented and subsequently properly notified by the persons responsible for the sector. In the event of complications involving bleeding, blood transfusion may be effected, independent of religious convictions or beliefs. I am aware that routine sanitary measures in blood banks ensure the quality of the blood and blood derivatives fromthis source, but that there are diseases such as AIDS, hepatitis and Chagas disease, among others, that can be transmitted. The routine procedures comprise blood collection by means of peripheral vein puncture, other examinations (when necessary), dressings and the usual postoperative care. In cases of surgical implants, new surgical procedures such as reoperation or removal of implants unrelated to the procedure will be duly excluded and explained. If damage to health were to occur as a result of this investigation, a new surgical procedure with exchange of the implant(s) will be performed if necessary. Discomfort, pain, loss of strength, diminished range of joint motion, motor incapacity and other risks are inherent to the surgical procedure. Current diseases compatible with the degree of surgical complexity may progress to definitive motor incapacity and death. I will be benefited directly through the opportunity to receive adequate treatment for the disease, in its present state, at the institution that I have voluntarily chosen, from trained and qualified professionals. Regarding alternative procedures that could be advantageous, which I might have chosen, I am rejecting these and placing this treatment as the best option for the present moment of the disease. I have had the opportunity to ask all the questions that I deemed fundamental, important and necessary, and all of these were answered fully and satisfactorily. I am aware of the confidentiality, secrecy and privacy of the study. Nonetheless, at any stage of the treatment, clarifications for possible doubts are assured and I can ask such questions by appointment. I will have the right to be kept up to date with regard to the partial results from the treatment, complications and favorable or unfavorable evolution of the present disease, with support for intercurrences from the Hand Surgery Outpatient Clinic of the Padre Anchieta Teaching Hospital. I have the obligation to declare all previous diseases, diabetes, hypertension, contagious diseases, hematological diseases, allergies, drug use, smoking, medications in use, psychiatric treatment, etc.; and to rigorously follow all the guidance, make return visits to the outpatient clinic, take medications in accordance with prescriptions and follow the rules of the hospital and the ABC School of Medicine. There will not be any financial compensation in relation to my participation in the surgery and in the study. I will have the right to the surgical treatments proposed, anesthesia and medical follow-up, in conformity with the fees paid for these procedures, which are expressed in the contract with the Brazilian National Health System (SUS), to which I have a right. If a health problem is detected prior to the start of the study, I would expect to be referred to SUS for treatment. I believe that I have received sufficient explanations regarding the information that I have received and read, relating to the treatment, risks and benefits to which I have a right, and all the obligations. The purposes of the treatment and the study are clear to me; it is also clear that this form does not encompass all the complications. I am aware of making my choice and decision, and I voluntarily agree to submit myself to the treatment proposed. Likewise, I acknowledge that, regardless of the efforts of the doctor and the team, there is no guarantee or absolute assurance that the results will bring a cure for my disease. The guidance regarding anesthesia, the blood bank, the intensive care unit and other factors remains under the responsibility of each hospital sector, and the surgical team does not hold these responsibilities. I declare for legal purposes that I have obtained information relating to voluntary free and informed consent in a clear, assured and appropriate manner. I have had the opportunity to ask all my questions and obtain all the responses. All the information will be confidential; I am free to withdraw from the study at any time without prejudicing my medical care; I may be excluded from the study; and the data will only be used for research. Place:____________ Signature of patient or legal representative Date____ /____ /____ Signature of witness Date ____/___ /___ Investigator Date____/___ /___ ).

Patients were excluded according to the following criteria: presentation of associated diseases of the wrist, such as osteometabolic diseases; having undergone any previous surgical procedure; or presentation of conditions that affected the wrists bilaterally.

The functional evaluation was conducted by professionals in the Hand Occupational Therapy Sector of the Mario Covas State Hospital, who did not have access to information on the group to which the patients belonged.

Functional measurements of wrist range of motion were made in degrees using a single specific goniometer. Palm grip strength was measured in kilogram-force (kgf) by means of a hydraulic dynamometer (Jamar(r)).

The clinical analysis on pain was performed using a visual analog scale (VAS) from zero to ten, for subjective evaluation.

Quality of life was assessed using the DASH questionnaire,99. Jester A, Harth A, Wind G, Germann G, Sauerbier M. Disabilities of the arm, shoulder and hand (Dash) questionnaire: determining functional activity profiles in patients with upper extremity disorders. J Hand Surg Br. 2005;30(1):23-8. which is the instrument used in the majority of studies published on treatments for fractures of the distal extremity of the radius.

The randomization consisted of making matches in groups of three, by means of a draw, using standardized tickets marked A, B or C (A, volar locking plate; B, intramedullary nail; C, external fixator). The tickets were placed in a bag and mixed, and then the secretary of the sector pulled out a single ticket and placed it on the table. This ticket did not participate further in the draw until the group of three had been completed. This was done in the outpatient clinic, before the surgery.

Thus, the patients were divided into three groups: A, B and C.

The patients underwent percutaneous minimally invasive osteosynthesis using one of the three different implants. The patients in group A received a volar locking plate,66. Sen MK, Strauss N, Harvey EJ. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg. 2008;12(1):2-6. and 1010. Orbay JL, Badia A, Indriago IR, Infante A, Khouri RK, Gonzalez E, et al. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg. 2001;5(4):204-11. those in group B received an intramedullary nail and those in group C received an external fixator.1111. Schønnemann JO, Hansen TB, Søballe K. Randomised study of non-bridging external fixation compared with intramedullary fixation of unstable distal radial fractures. J Plast Surg Hand Surg. 2011;45(4-5):232-7.

Operative technique for osteosynthesis with volar locking plate (group A)

A volar access was used, under the radial flexor tendon of the carpus, 1 cm distally to the fracture, with dissection in layers down to the radius bone (Table 1).

Table 1
Epidemiological distribution and postoperative follow-up of the patients in group A.

The volar plate was slid in with the aid of radioscopy, through which the ideal positioning could be viewed.

Closed reduction of the fracture was performed, with provisional placement of one Kirschner wire.

A distal volar access was made in the wrist, at the exact location of the first hole of the plate, with dissection in layers down to the bone.

The plate was fixed using a 2.5 mm proximal cortical screw and a 2.5 mm distal locking screw, with viewing of the reduction with the aid of radioscopy.

The remaining screws were then put in: six distal and three proximal screws.1212. Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. Numberand locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg Am. 2010;35(6):885-91.

The layers and the skin were then sutured.

Postoperative radioscopy and radiography were performed on the wrist to check on the surgery.

A dressing was then placed around the wrist.

Operative technique for osteosynthesis with intramedullary locking nail (group B)

Closed reduction was performed on the fracture and it was stabilized provisionally using one or two Kirschner wires inserted in the region of the distal ulna, as far as the medial column of the radius, with the aid of radioscopy (Table 2).

Table 2
Epidemiological distribution and postoperative follow-up of the patients in group B.

The access route was minimal, dorsal and radial, measuring 2 cm, using the first extensor tunnel as the anatomical parameter. A single longitudinal opening was made in the dorsal retinaculum, with exposure of the extensor tendons of the first tunnel, which were pushed away dorsally.

A standard Kirschner wire and guide were then implanted in the region proximal to the radial styloid, which was pegged in the metaphyseal intramedullary region of the radius, just below the first extensor tunnel.

Intramedullary milling was performed using a specific cannulated drill bit, with a guidewire as an essential parameter.

Intramedullary milling tools of the size of the nail (ranging from one to five) were then emplaced manually. For perfect adjustment of the milling tool with the medulla of the bone, the size of the implant to be used was measured.

Finally, the intramedullary nail was emplaced, with the aid of radioscopy.

The fracture was stabilized distally using three 2.7 mm lateral locking screws, which enabled angular stability, using a guide adjacent to the nail.

The system was stabilized proximally using two 2.4 mm dorsal cortical screws, with the aid of a specific guide.

The layers and skin were sutured.

Postoperative radioscopy and radiography were performed on the wrist to check on the surgery.

A dressing was then placed around the wrist.

Operative technique for osteosynthesis with nonbridging external fixator (group C)

Percutaneous accesses measuring 0.5 mm were made in the radial styloid and in the distal region of the medial column of the radius, in order to insert Kirschner wires (Table 3).

Table 3
Epidemiological distribution and postoperative follow-up of the patients in group C.

Closed reduction was performed on the fracture and two crossed Kirschner wires were emplaced: one entering through the radial styloid and the other through the distal region of the medial column of the bone.

Two 3 mm Schanz pins were placed dorsally and distally to the fracture and two Schanz pins were placed dorsally radially and proximally to the fracture.

The external fixator was assembled on the Schanz pins, which allowed mobility of the wrist and enabled secure stabilization of the fracture.

The skin was sutured.

Postoperative radioscopy and radiography were performed on the wrist to check on the surgery.

A dressing was then placed around the wrist.

Postoperative period for groups A, B and C

The patients were clinically and radiographically assessed before the operation and afterwards, in the third and sixth weeks and sixth month. All of them underwent rehabilitation at the institution's Hand Occupational Therapy Sector, using the same protocol for analgesia, kinesiotherapy and functional gain, from the first week after the surgery until discharge.

This study was approved by the Medical Research Ethics Committee of the ABC School of Medicine in July 2007, through CEP/FMABC Protocol Registration No. 160/2007.

All the data were sent for statistical analysis. The statistical level of 5% (0.050) was used for applying statistical tests, i.e. when the calculated significance value (p) was less than 5% (0.050), a difference that was said to be "statistically significant" was observed (marked in red); and when the calculated significance value (p) was greater than or equal to 5% (0.050), a difference that was said to be "statistically non-significant" was observed. The SPSS software (Statistical Package for the Social Sciences), version 13.0, was used to obtain the results.

Results

The results from the patients were presented at three study times: third week (Table 4), sixth week (Table 5) and twelfth month (Table 6).

Table 4
Clinical and functional results in the third week.
Table 5
Clinical and functional results in the sixth week.
Table 6
Clinical and functional results in the 12th month.

Statistical study

The three groups studied were described and compared (horizontal statistical analysis) by applying the Kruskal-Wallis test, with the aim of ascertaining possible differences between the three groups studied, when compared concomitantly for the variables of interest.

Since some differences that were said to be statistically different were encountered, the Mann-Whitney test was applied, with adjustment using the Bonferroni correction, in order to attempt to identify which groups differed from each other when compared pair by pair.

The data were described and compared between the observation times, for each study group (vertical statistical analysis).

The Friedman test was applied, with the aim of ascertaining possible differences between the three observation times, for each study group and for the variables of interest.

Since there were statistically significant differences in all of the comparisons made, the Wilcoxon signed-rank test was applied, with adjustment using the Bonferroni correction, in order to attempt to identify which observation times differed from each other when compared pair by pair.

Complications

One patient in group B presented pain in the wrist, probably due to proximity of the distal locking screw to the first extensor tunnel. Just after the sixth month after the operation, this screw was removed and the pain ceased.

Another patient, in group C, presented wrist pain on the path of the sensory branch of the radial nerve, due to proximity of the presence of the Schanz pin. This pain also improved with removal of the pin in the sixth month after the surgery.

Discussion

Evolution of the treatments for fractures of the distal extremity of the radius has taken place along two lines: technologically, through development of implants that enable angular stability, and biologically, also through stabilizing the bone, but preserving the covering of soft tissues and thus enabling earlier functional return for this joint and leaving patients with less economic and social damage.

New designs for volar plates with a minimum thickness of only 2 or 3 mm, and new designs for instruments, with guides coupled to the intramedullary nail, along with the use of radiotransparent materials for external fixators, which have become established for treating these fractures over the last ten years, have made it possible to use minimally invasive techniques.

From vertical analysis, i.e. making comparisons between the data obtained within each group, our study showed statistically significant functional clinical results, irrespective of the implant, at all assessment times of the study, which showed that the minimally invasive technique was effective.

From the analysis on the radiographic parameters, all the patients presented the same initial reduction of the fracture, which showed that all the implants used in this study were safe and stable, thus enabling effective bone consolidation at the fracture.

Horizontal comparison of the functional clinical results between the groups (range of motion, palm grip strength, DASH and VAS) showed that there were statistically significant differences between the values for group C and those for groups A and B, in the third and sixth weeks after the surgery. From this, we can affirm that the patients who were treated with an intramedullary nail or a volar plate presented better quality of life and fewer pain symptoms than did those who were treated with an external fixator, up to the sixth week. However, after the sixth week, the clinical-functional parameters became statistically similar between the three groups.

The data obtained in this study were also compared with those from studies in the literature. Our results were similar to those of Schønnemann et al.1111. Schønnemann JO, Hansen TB, Søballe K. Randomised study of non-bridging external fixation compared with intramedullary fixation of unstable distal radial fractures. J Plast Surg Hand Surg. 2011;45(4-5):232-7. The palm grip strength results were better among patients treated with an intramedullary nail than among patients treated with a nonbridging external fixator,1212. Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. Numberand locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg Am. 2010;35(6):885-91. , 1313. McQueen MM. Redisplaced unstable fractures of the distal radius. A randomised, prospective study of bridging versus non-bridging external fixation. J Bone Joint Surg Br. 1998;80(4):665-9. , 1414. Wolfe SW, Austin G, Lorenze M, Swigart CR, Panjabi MM. A biomechanical comparison of different wrist external fixators with and without K-wire augmentation. J Hand Surg Am. 1999;24(3):516-24. and 1515. Yamako G, Ishii Y, Matsuda Y, Noguchi H, Hara T. Biomechanical characteristics of nonbridging external fixators for distal radius fractures. J Hand Surg Am. 2008;33(3):322-6. and the results relating to the radiographic parameters analyzed were similar, without any loss of the initial reduction, after consolidation of the fracture. We also used Kirschner wires in association with external fixators, in order to ensure greater fracture stability.1414. Wolfe SW, Austin G, Lorenze M, Swigart CR, Panjabi MM. A biomechanical comparison of different wrist external fixators with and without K-wire augmentation. J Hand Surg Am. 1999;24(3):516-24.

Comparing our values with those of Cui et al.,1616. Cui Z, Pan J, Yu B, Zhang K, Xiong X. Internal versus external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Int Orthop. 2011;35(9):1333-41. there were similarities in the results, with better evidence among the patients treated with a volar plate than among those treated with an external fixator.

Although the study by Zenke et al.1717. Zenke Y, Sakai A, Oshige T, Moritani S, Fuse Y, Maehara T, et al. Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma. 2011;25(7): 425-31. did not show any significant differences between the conventional method and the minimally invasive method using volar plates for treating these fractures, we observed better clinical-functional and DASH results in our study, in relation to the study by Orbay et al.,1010. Orbay JL, Badia A, Indriago IR, Infante A, Khouri RK, Gonzalez E, et al. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg. 2001;5(4):204-11. with palm grip strength of 97% versus 77% and DASH of 1.1 versus 8.28.

Regarding the number of screws for stabilizing the volar plate, better fixation was observed with three screws inserted proximally to the fracture focus (diaphyseal location) and at least six locking screws distally to the fracture focus. This was also observed in the biomechanical study by Mehling et al.1212. Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. Numberand locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg Am. 2010;35(6):885-91.

In evaluating complications, the studies by Richard et al.1818. Richard MJ, Wartinbee DA, Riboh J, Miller M, Leversedge FJ, Ruch DS. Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J Hand Surg Am. 2011;36(10):1614-20. and Rampoldi and Marsico1919. Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg. 2007;73(6):714-9. showed better functional results and a lower rate of complications among patients treated with volar plates than among those with external fixation. This was also observed in the present study, with values of 6.25% in group C and 0% in group A.

In a systematic review, Espósito et al.2020. Esposito J, Schemitsch EH, Saccone M, Sternheim A, Kuzyk PR. External fixation versus open reduction with plate fixation for distal radius fractures: ameta-analysis of randomised controlled trials. Injury. 2013;44(4):409-16. found a lower DASH score, better restoration of the length of the radius and lower infection rate in the group of patients with fractures who were treated by means of internal osteosynthesis using a plate than in those treated using an external fixator. These results resemble those of the present study.

Both in our study and in that of Xie et al.2121. Xie X, Xie X, Qin H, Shen L, Zhang C. Comparison of internal and external fixation of distal radius fractures. Acta Orthop. 2013;84(3):286-91. in 2013 (which was a systematic review on surgical treatment of these fractures), there were better functional results (forearm supination, restoration of palmar tilt and radial slope and a lower complication rate) in the group of patients treated with a volar plate than in those treated with an external fixator.

Sando et al.2222. Sando IC, Malay S, Chung KC. Analysis of publication bias in the literature for distal radius fracture. J Hand Surg Am. 2013;38(5):927-34, e5. conducted a study that showed the existence of publication bias among articles on surgical treatment of the distal extremity of the radius and found that out of the 215 studies analyzed, 75% presented positive results, 20% neutral results and 5% negative final values. These authors concluded that these articles presented characteristics that would lead to positive results and that these results may have facilitated publication of these studies. They also suggested that a standardized clinical register covering the entire United States should be created for the results to be followed up and assessed. In our study, we attempted to use minimally invasive methods, cases in which the fractures had the same characteristics and recognized assessment and rehabilitation protocols in order to minimize these sources of bias.

Although using intramedullary nails to treat these fractures is not common in our setting, it could be seen in the present study that the results obtained were excellent and that the learning curve was short.

Conclusion

The minimally invasive technique is effective and safe, with clinical and functional improvements at all observation times of the study. The three implants were stable, given that there were no alterations in the radiographic parameters. There were statistically significantly better clinical-functional results (degree of strength, range of motion, DASH and VAS) in group A (plate) and group B (nail), up to the sixth week. However, after the 12th month, there were no statistically significant differences in the clinical-functional parameters analyzed, between the three groups.

REFERENCES

  • 1
    Alffram PA, Bauer GC. Epidemiology of fractures of the forearm. A biomechanical investigation of bone strength. J Bone Joint Surg Am. 1962;44:105-14.
  • 2
    Angelini LC, Grecco MAS. Tratamento da pseudartrose do terço distal do rádio. Acta Ortop Bras. 2005;13(2):95-9.
  • 3
    Fernandez DL, Palmer AK. Fractures of the distal radius. In: Green DP, Hotchkiss RN, Pederson WC, editors. Green's operative hand surgery. 4th ed. New York: Churchill Livingstone; 1999. p. 925-85.
  • 4
    Wei DH, Poolman RW, Bhandari M, Wolfe VM, Rosenwasser MP. External fixation versus internal fixation for unstable distal radius fractures: a systematic review and meta-analysis of comparative clinical trials. J Orthop Trauma. 2012;26(7):386-94.
  • 5
    Nishiwaki M, Tazaki K, Shimizu H, Ilyas AM. Prospective study of distal radial fractures treated with an intramedullary nail. J Bone Joint Surg Am. 2011;93(15):1436-41.
  • 6
    Sen MK, Strauss N, Harvey EJ. Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg. 2008;12(1):2-6.
  • 7
    Handoll HH, Madhok R. Withdrawn: surgical interventions for treating distal radial fractures in adults. Cochrane Database Syst Rev. 2009;(3):CD003209.
  • 8
    Rayhack JM. The history and evolution of percutaneous pinning of displaced distal radius fractures. Orthop Clin North Am. 1993;24(2):287-300.
  • 9
    Jester A, Harth A, Wind G, Germann G, Sauerbier M. Disabilities of the arm, shoulder and hand (Dash) questionnaire: determining functional activity profiles in patients with upper extremity disorders. J Hand Surg Br. 2005;30(1):23-8.
  • 10
    Orbay JL, Badia A, Indriago IR, Infante A, Khouri RK, Gonzalez E, et al. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg. 2001;5(4):204-11.
  • 11
    Schønnemann JO, Hansen TB, Søballe K. Randomised study of non-bridging external fixation compared with intramedullary fixation of unstable distal radial fractures. J Plast Surg Hand Surg. 2011;45(4-5):232-7.
  • 12
    Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. Numberand locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg Am. 2010;35(6):885-91.
  • 13
    McQueen MM. Redisplaced unstable fractures of the distal radius. A randomised, prospective study of bridging versus non-bridging external fixation. J Bone Joint Surg Br. 1998;80(4):665-9.
  • 14
    Wolfe SW, Austin G, Lorenze M, Swigart CR, Panjabi MM. A biomechanical comparison of different wrist external fixators with and without K-wire augmentation. J Hand Surg Am. 1999;24(3):516-24.
  • 15
    Yamako G, Ishii Y, Matsuda Y, Noguchi H, Hara T. Biomechanical characteristics of nonbridging external fixators for distal radius fractures. J Hand Surg Am. 2008;33(3):322-6.
  • 16
    Cui Z, Pan J, Yu B, Zhang K, Xiong X. Internal versus external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Int Orthop. 2011;35(9):1333-41.
  • 17
    Zenke Y, Sakai A, Oshige T, Moritani S, Fuse Y, Maehara T, et al. Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma. 2011;25(7): 425-31.
  • 18
    Richard MJ, Wartinbee DA, Riboh J, Miller M, Leversedge FJ, Ruch DS. Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J Hand Surg Am. 2011;36(10):1614-20.
  • 19
    Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg. 2007;73(6):714-9.
  • 20
    Esposito J, Schemitsch EH, Saccone M, Sternheim A, Kuzyk PR. External fixation versus open reduction with plate fixation for distal radius fractures: ameta-analysis of randomised controlled trials. Injury. 2013;44(4):409-16.
  • 21
    Xie X, Xie X, Qin H, Shen L, Zhang C. Comparison of internal and external fixation of distal radius fractures. Acta Orthop. 2013;84(3):286-91.
  • 22
    Sando IC, Malay S, Chung KC. Analysis of publication bias in the literature for distal radius fracture. J Hand Surg Am. 2013;38(5):927-34, e5.
  • Please cite this article as: Aita MA, Vieira Ferreira CH, Schneider Ibanez D, Saraiva Marquez R, Hideki Ikeuti D, Toledo Mota R, et al. Ensaio clínico randomizado de osteossíntese percutânea e minimamente invasiva das fraturas da extremidade distal do rádio. Rev Bras Ortop. 2014;49:218-226.
  • ☆☆
    Work performed by the Hand and Microsurgery Group, ABC School of Medicine, Santo André, SP, Brazil.

Anex 1. Voluntary free and informed consent statement

Study: a randomized comparative study using external fixators, percutaneous volar plates and intramedullary nails to surgically treat fractures of the distal extremity of the radius.

Principal investigator: Walter Yoshinori Fukushima; Medical Registration Number (CRM): 109969-SP.

Address: Rua Morvan Dias de Figueiredo, 155, apto 12, CEP 09732-580, São Bernardo do Campo, São Paulo.

Discipline of Diseases of the Locomotor System (Orthopedics and Traumatology), ABC School of Medicine, Avenida Lauro Gomes, 2000, Bairro Vila Sacadura Cabral, Santo André – SP, CEP 09060-870, Brazil. Tel: +55 011 4993 5400.

This study was assessed and approved by the institution’s Research Ethics Committee on July 4, 2007 (registration no. 160/2007). This committee is a body that has the aim of protecting your well-being. It is responsible for assessing and following up the ethical issues of all studies involving human beings so that the dignity, rights, safety and well-being of the research subjects are ensured. If you have any doubts and/or questions about your rights as a participant in this study, or if you are dissatisfied with the way in which the study is being conducted, you can get in touch with the Research Ethics Committee of the ABC School of Medicine at the following address: Avenida Príncipe de Gales, 821, 1st floor, CEPES Building, Santo André, SP, or by telephone: (11)-4993-5453. The hours of attendance are from Monday to Friday from 07:00 to 17:00.

Name of subject or person with legal responsibility:________________

No. of identity document:_____________

Sex: M ()/F ()

Date of birth: ____/___ /___

Telephone: ()

Address:_________

I, Mr/Ms______________; declare for legal purposes that I am being guided in relation to all the risks, discomforts and benefits that result directly or indirectly (causal link) from the procedure(s) that I am undergoing. My participation as a patient, and/or the person responsible, is voluntary and I am aware that I am receiving the best treatment options for the disease or condition that I have, in its current state. I am aware that this participation is for a period of five years. The treatment offered, i.e. surgical treatment with a volar plate for angular stability, a nonbridging external fixator or an intramedullary locking nail, has the aim of achieving adequate stabilization of the fracture of the distal extremity of the radius. It has been discussed and is appropriate and adequate, such that it provides improvement of the present conditions. These surgical procedures will be carried out in patients with a diagnosis of fracturing of the distal radius, comprising the abovementioned surgical treatment. I am aware that complications relating to the disease may occur, with procedures equivalent to the complexity of the general clinical picture, local state and hospital conditions. The surgery will be accompanied by anesthetic procedures and possible complications such as anaphylaxis, drug interactions, cardiorespiratory arrest and various allergies. There are risks of implant loosening and surgical site infection. Additional procedures with medical indications due to severe risks will be performed as described in the literature, if these are essential formy benefit, for treatment in viewof emergency situations that might occur, and no non-routine procedures will be performed. If the use of intensive care units, semi-intensive care unit, blood transfusion or special examinations after the procedure(s) becomes necessary, these will be implemented and subsequently properly notified by the persons responsible for the sector. In the event of complications involving bleeding, blood transfusion may be effected, independent of religious convictions or beliefs. I am aware that routine sanitary measures in blood banks ensure the quality of the blood and blood derivatives fromthis source, but that there are diseases such as AIDS, hepatitis and Chagas disease, among others, that can be transmitted. The routine procedures comprise blood collection by means of peripheral vein puncture, other examinations (when necessary), dressings and the usual postoperative care. In cases of surgical implants, new surgical procedures such as reoperation or removal of implants unrelated to the procedure will be duly excluded and explained. If damage to health were to occur as a result of this investigation, a new surgical procedure with exchange of the implant(s) will be performed if necessary.

Discomfort, pain, loss of strength, diminished range of joint motion, motor incapacity and other risks are inherent to the surgical procedure. Current diseases compatible with the degree of surgical complexity may progress to definitive motor incapacity and death. I will be benefited directly through the opportunity to receive adequate treatment for the disease, in its present state, at the institution that I have voluntarily chosen, from trained and qualified professionals. Regarding alternative procedures that could be advantageous, which I might have chosen, I am rejecting these and placing this treatment as the best option for the present moment of the disease. I have had the opportunity to ask all the questions that I deemed fundamental, important and necessary, and all of these were answered fully and satisfactorily. I am aware of the confidentiality, secrecy and privacy of the study.

Nonetheless, at any stage of the treatment, clarifications for possible doubts are assured and I can ask such questions by appointment. I will have the right to be kept up to date with regard to the partial results from the treatment, complications and favorable or unfavorable evolution of the present disease, with support for intercurrences from the Hand Surgery Outpatient Clinic of the Padre Anchieta Teaching Hospital. I have the obligation to declare all previous diseases, diabetes, hypertension, contagious diseases, hematological diseases, allergies, drug use, smoking, medications in use, psychiatric treatment, etc.; and to rigorously follow all the guidance, make return visits to the outpatient clinic, take medications in accordance with prescriptions and follow the rules of the hospital and the ABC School of Medicine. There will not be any financial compensation in relation to my participation in the surgery and in the study. I will have the right to the surgical treatments proposed, anesthesia and medical follow-up, in conformity with the fees paid for these procedures, which are expressed in the contract with the Brazilian National Health System (SUS), to which I have a right. If a health problem is detected prior to the start of the study, I would expect to be referred to SUS for treatment. I believe that I have received sufficient explanations regarding the information that I have received and read, relating to the treatment, risks and benefits to which I have a right, and all the obligations. The purposes of the treatment and the study are clear to me; it is also clear that this form does not encompass all the complications. I am aware of making my choice and decision, and I voluntarily agree to submit myself to the treatment proposed. Likewise, I acknowledge that, regardless of the efforts of the doctor and the team, there is no guarantee or absolute assurance that the results will bring a cure for my disease. The guidance regarding anesthesia, the blood bank, the intensive care unit and other factors remains under the responsibility of each hospital sector, and the surgical team does not hold these responsibilities. I declare for legal purposes that I have obtained information relating to voluntary free and informed consent in a clear, assured and appropriate manner. I have had the opportunity to ask all my questions and obtain all the responses. All the information will be confidential; I am free to withdraw from the study at any time without prejudicing my medical care; I may be excluded from the study; and the data will only be used for research.

Place:____________

Signature of patient or legal representative Date____ /____ /____

Signature of witness Date ____/___ /___

Investigator Date____/___ /___

Publication Dates

  • Publication in this collection
    May-June 2014

History

  • Received
    16 June 2013
  • Accepted
    21 June 2013
Sociedade Brasileira de Ortopedia e Traumatologia Al. Lorena, 427 14º andar, 01424-000 São Paulo - SP - Brasil, Tel.: 55 11 2137-5400 - São Paulo - SP - Brazil
E-mail: rbo@sbot.org.br