Acessibilidade / Reportar erro

Osseointegration and Success in Hip Arthroplasty Acetabular Revision Using Structured Homologous Graft: Average 9.6 Years Follow-up

Abstract

Objective

To evaluate the clinical and radiographic results and survival of the acetabular revision surgery of total hip arthroplasty with cemented implant without the use of reinforcement ring, associated with structural homologous bone grafting.

Methods

A total of 40 patients (44 hips) operated from 1995 to 2015 were retrospectively analyzed. Radiographs were evaluated according to the classification of the acetabular bone defect, graft shape, and the presence of osseointegration. Cases were considered as failures when the migration of the implant was > 5 mm in any direction, and/or the progression of radiolucency lines around the acetabular component were > 2 mm. We verified the association of radiographic findings with cases of failure using statistical tests and analyzed survival using the Kaplan-Meier curve.

Results

Of the 44 hips, 45.5% of the acetabular defects were Paprosky type 3A and 50% were 3B. In 65% of the hips, the graft configuration was classified as Prieto type 1 and in 31% as type 2. No radiographic evidence of osseointegration was observed in 13.6% of the cases. We observed 9 (20.5%) reconstruction failures. A correlation was observed between reconstruction failure and the absence of radiographic signs of graft osseointegration.

Conclusion

We observed good clinic and radiographic results, with survival of 79.54% in a mean follow-up of 9.65 years. Also, there was an association between absence of radiographic signs of osseointegration of the structural graft and failure in this series of patients with large bone defects. The failures did not correlate with the severity of the acetabular bone defect, thickness, or graft configuration.

arthroplasty, replacement, hip; grafting bone; cross-sectional studies; osseointegration; transplantation, homologous, reoperation; osteointegration

Resumo

Objetivo

Avaliarosresultadosclínicos, radiográficos e a sobrevida da cirurgia de revisão acetabular de artroplastia total de quadril com implante cimentado sem uso de anel de reforço, associado à enxertia óssea homóloga estrutural.

Métodos

Um total de 40 pacientes (44 quadris) operados de 1995 a 2015 foram analisados retrospectivamente. As radiografias foram avaliadas de acordo com a classificação do defeito ósseo acetabular, o formato do enxerto e à presença de osteointegração. Foram considerados casos de insucesso a migração do implante > 5 mm em qualquer direção e/ou a progressão de linhas de radioluscência em torno do componente acetabular > 2mm. Verificamos a associação dos achados radiográficos com os casos de falha utilizando testes estatísticos e analisamos a sobrevida utilizando a curva de Kaplan-Meier.

Resultados

Dos 44 quadris, 45,5% dos defeitos acetabulares eram Paprosky tipo 3A e 50%, 3B. Em 65% dos quadris, a configuração do enxerto foi classificada como tipo 1 de Prieto e em 31% como tipo 2. Não foi observada evidência radiográfica de osteointe-gração em 13,6% dos casos. Observamos 9 (20,5%) falhas de reconstrução. Foi observada correlação entre falha da reconstrução com a ausência de sinais radiográficos de osteointegração do enxerto.

Conclusão

Observamos bons resultados clínicos e radiográficos, com sobrevida de 79,54% em seguimento médio de 9,65 anos. Também houve associação entre ausência de sinais radiográficos de osteointegração do enxerto estrutural e falha nesta série de pacientes com grandes defeitos ósseos. As falhas não se correlacionaram com a severidade do defeito ósseo acetabular, espessura ou configuraçãodoenxerto.

artroplastia de quadril; enxerto ósseo; estudos transversais; osteointegração; transplante homólogo; reoperação

Introduction

Acetabular reconstruction surgery during total hip arthroplasty revision (THAR) is a complex procedure. Loosening of the implant after arthroplasty is one of the most frequent complications in the long term, leading to bone loss.11 Meneghini RM, Ford KS, McCollough CH, Hanssen AD, Lewallen DG. Bone remodeling around porous metal cementless acetabular components. J Arthroplasty 2010;25(05):741-747 The main objectives of acetabular reconstruction surgery are to obtain implant stability by restoring the hip anatomy with positioning of the component as close as possible to the center of joint rotation.22 Prieto HA, Kralovec ME, Berry DJ, Trousdale RT, Sierra RJ, Cabanela ME. Structural allograft supporting a trabecular metal cup provides durable results in complex revision arthroplasty. J Arthro-plasty 2017;32(11):3488-3494

There are several forms of treatment of large acetabular bone defects in THAR: placement of implant with high hip center of rotation (High Hip Center), use of large diameter implants (Jumbo cup), use of structural homologous bone graft (with or without reinforcement ring), impaction of fragmented homologous bone graft (with or without reinforcement ring), in addition to the use of enlargements in trabecular metal.33 Stigbrand H, Gustafsson O, Ullmark G. A 2- to 16-Year Clinical Follow-Up of Revision Total Hip Arthroplasty Using a New Acetabular Implant Combined With Impacted Bone Allografts and a Cemented Cup. J Arthroplasty 2018;33(03):815-822 However, the most appropriate treatment remains undefined.44 Guimarães RP, Yonamine AM, Faria CEN, Rudelli M. Is the size of the acetabular bone lesion a predictive factor for failure in revisions of total hip arthroplasty using an impacted allograft? Rev Bras Ortop 2016;51(04):412-417, 55 Butscheidt S, Moritz M, Gehrke T, et al. Incorporation and Remodeling of Structural Allografts in Acetabular Reconstruction: Multiscale, Micro-Morphological Analysis of 13 Pelvic Explants. J Bone Joint Surg Am 2018;100(16):1406-1415

Our service started the use of homologous graft in THAR in the 1980s, with the subsequent publication of the results.66 Roos MV, Roos BD, Sampaio CM, Marques PR Junior. Evaluation of a method of acetabular reconstruction using homologous bone graft and cemented implant. Rev Bras Ortop 2008;43(09): 367-375

7 Roos MV, Roos BD, Giora TS, Taglietti TM. Use ofcortical structural homologous bone graft in femoral reconstructive surgery. Rev Bras Ortop 2015;45(05):483-489
-88 Roos BD, Roos MV, Camisa A Jr. Circumferential proximal femoral allografts in revision hip arthroplasty: four to 20 years follow-up. Hip Int 2013;23(01):66-71The analysis of our cases and the result of the literature allows the verification of homologous bone graft consolidation with possible osseointegration in most cases, allowing a stable reconstruction.22 Prieto HA, Kralovec ME, Berry DJ, Trousdale RT, Sierra RJ, Cabanela ME. Structural allograft supporting a trabecular metal cup provides durable results in complex revision arthroplasty. J Arthro-plasty 2017;32(11):3488-3494 The use of bone graft makes it possible to restore the center of hip rotation, obtain implant stability, restore the acetabular integrity and bone stock, facilitating future revisions.99 Gerhardt DMJM, De Visser E, Hendrickx BW, Schreurs BW, Van Susante JLC. Bone mineral density changes in the graft after acetabular impaction bone grafting in primary and revision hip surgery. Acta Orthop 2018;89(03):302-307 With the stability of the graft in reconstruction, it is possible to provide conditions for revas-cularization and osseointegration to the host bone.99 Gerhardt DMJM, De Visser E, Hendrickx BW, Schreurs BW, Van Susante JLC. Bone mineral density changes in the graft after acetabular impaction bone grafting in primary and revision hip surgery. Acta Orthop 2018;89(03):302-307 The disadvantages that can be found with this technique are the potential resorption of the graft and the nonunion to the host bone.1010 Hooten JP Jr, Engh CA Jr, Engh CA. Failure of structural acetabular allografts in cementless revision hip arthroplasty. J Bone Joint Surg Br 1994;76(03):419-422,1111 Kwong LM, Jasty M, Harris WH. High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 years. J Arthroplasty 1993;8(04):341-346

The aim of the present study is to evaluate the clinical and radiographic results and survival of acetabular reconstruction surgery with cemented implant without the use of reinforcement ring, associated with structural homologous bone grafting.

Materials and Methods

Between January 1995 and August 2015, 318 patients were submitted to THAR by 2 surgeons from the same medical team (Roos B. D. e Roos M. V.). Of these, 71 were submitted to THAR with the use of cemented acetabular implant without reinforcement ring associated with structural homologous bone grafting. Thirty-one patients were excluded due to loss of follow-up, follow-up < 24 months, or for presenting incomplete medical records or exams. Forty patients were analyzed (44 hips) in a retrospective study (►Table 1).

Table 1
Clinical and demographic characteristics of cases (operated hips)

The decision to use the technique evaluated in the present study was the preoperative radiographic finding of segmental or combined acetabular bone defects, in addition to large cavitary defects, with or without pelvic discontinuity (D'An-tonio Classification1212 D'Antonio JA, Capello WN, Borden LS, et al. Classification and management of acetabular abnormalities in total hip arthro-plasty. Clin Orthop Relat Res 1989;(243):126-137). The study was initiated after approval by the Ethics Committee of our institution.

Clinical Evaluation

Late pre- and postoperative clinical evaluation was performed in all patients using the Harris Hip Score (HHS) hip evaluation score.1313 Guimaraes RP, Alves DPL, Silva GB, et al. Translation and cultural adaptation of the Harris Hip Score into Portuguese. Acta Ortop Bras 2010;18(03):142-147

Radiographic Evaluation

Standardized radiographs of the pelvis were performed preoperatively, in the immediate postoperative period, and in the follow-up exams at 6 weeks, 3 months, 6 months, and, afterwards, annually.

The classification of the acetabular bone defect was preoperatively evaluated using the Paprosky1414 Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 1994;9(01):33-44 and D'Anto-nio methods,1212 D'Antonio JA, Capello WN, Borden LS, et al. Classification and management of acetabular abnormalities in total hip arthro-plasty. Clin Orthop Relat Res 1989;(243):126-137 in addition to the size of the defect in millimeters.66 Roos MV, Roos BD, Sampaio CM, Marques PR Junior. Evaluation of a method of acetabular reconstruction using homologous bone graft and cemented implant. Rev Bras Ortop 2008;43(09): 367-375

On immediate postoperative radiography, the percentage of coverage of the acetabular component by the structural graft and the measurement in millimeters of the largest craniocaudal thickness of the graft were evaluated. To describe the configuration of the structural graft in the acetab-ulum, we used the description published by Prieto et al.,22 Prieto HA, Kralovec ME, Berry DJ, Trousdale RT, Sierra RJ, Cabanela ME. Structural allograft supporting a trabecular metal cup provides durable results in complex revision arthroplasty. J Arthro-plasty 2017;32(11):3488-3494which defined it in three types: Type 1, buttress configuration or "flying buttress"; Type 2, dome support; and, Type 3, on base or "footing".

On later postoperative radiography, osseointegration of the graft was classified as described in another publication, which became known as the "Coon criterion".1515 da Silva AF, Antebi U, Honda EK, Rudelli M, Guimarães RP. Comparative Study of the Osteointegration of Irradiated and Non-irradiated Bone Grafts Used in Patients with Revision Hip Arthroplasty. Rev Bras Ortop 2019;54(04):477-482 Type 1 was defined as total continuity of the bone trabeculate at the interface between the host bone and the graft (total osseoin-tegration); Type 2, as partial continuity of the bone trabecu-late at the interface between the host bone and the graft (partial osseointegration); Type 3, as absence ofcontinuityof the bone trabeculate at the interface between the host bone and the graft (absence of osseointegration); and Type 4 as impossibility of visualization of the graft due to the presence of prosthetic components (screens, reinforcement rings, etc.).

In serial radiographs, the presence of progressive radio-lucent lines around the acetabular component, and signs of graft resorption and osteolysis were evaluated, according to the acetabular zones determined by DeLee et al.1616 DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976; (121):20-32

The migration of the acetabular component was measured in radiographs obtained in the immediate postoperative period compared to the later one, through parameters defined by Knight et al.,1717 Knight JL, Fujii K, Atwater R, Grothaus L. Bone-grafting for acetabular deficiency during primary and revision total hip arthroplasty. A radiographic and clinical analysis. J Arthroplasty 1993;8(04):371 -382 having as reference points the teardrop of both hips, the Köhler line, and the hip rotation center.

The reconstruction was considered a failure when there was loosening of the implant with migration > 5 mm in any direction, and/or the progression of radiolucent lines around the acetabular component > 2 mm wide. The cases of failure were compared with the others (success) seeking correlation with the classification of the bone defect according to Paprosky et al.1414 Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 1994;9(01):33-44 and D'Antonio et al.,1212 D'Antonio JA, Capello WN, Borden LS, et al. Classification and management of acetabular abnormalities in total hip arthro-plasty. Clin Orthop Relat Res 1989;(243):126-137 the size of the bone defect in millimeters,66 Roos MV, Roos BD, Sampaio CM, Marques PR Junior. Evaluation of a method of acetabular reconstruction using homologous bone graft and cemented implant. Rev Bras Ortop 2008;43(09): 367-375 the largest thickness of the graft in millimeters, the percentage of implant coverage by the graft, osseointegration of the graft,1515 da Silva AF, Antebi U, Honda EK, Rudelli M, Guimarães RP. Comparative Study of the Osteointegration of Irradiated and Non-irradiated Bone Grafts Used in Patients with Revision Hip Arthroplasty. Rev Bras Ortop 2019;54(04):477-482 the presence of graft resorption and osteolysis, in addition to its configuration.1818 Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res 2004;(429): 201-208

To avoid inter- and intra-observer errors, the measurements were performed by one team member and reviewed byanother. In case there was disagreement, a newevaluation was performed by a third member of the team, and then a consensus was reached.

Surgical Technique

We used the modified Hardinge anterolateral surgical approach in all cases. Initially, the acetabular component is removed; later, debris and fibrous tissue are cleaned from the cavity, using curettes and acetabular cutters, to reach a surface that is cruent and able to receive the graft. Then, the removal of the femoral stem is performed when necessary.

The graft is prepared and washed with saline, block graft was used on the acetabular ceiling associated or not with a chopped graft. After cleaning the acetabulum, a bed is prepared with impacted chopped graft at the site that will receive the bone block, so that there are no "dead zones" that allow the formation of fibrous tissue or cysts, hindering the consolidation and possible integration of the block.

The fixation of the structural graft in the host bone is through 3.5 mm spongy screws with partial thread, at a 45° angle and in variable number according to the size and number of bone blocks used. After fixing the graft, the cavity is milled until it reaches the ideal size. After complementary filling of the existing defects, the acetabular component is placed, cemented or not, and at least one anchorage is performed, made superiorly with a 10 mm drill, necessarily reaching the host bone, and another made in the ischium through the host bone, impacted graft, or bone block (depending on the size of the existing cavity). We used an iodopovidone solution with saline solution throughout the transoperative period.

Postoperative Management

Mechanical thromboembolic prophylaxis was used in the immediate postoperative period, prophylactic oral antico-agulation for 30 days and antibiotic prophylaxis with vanco-mycin and ceftriaxone. In addition, one gram of ceftazidime is added to each dose of bone cement used. A radiographic evaluation is performed 6 weeks after the surgical procedure, from that moment on, full support with a crutch is allowed as an accessory element of balance.

Statistical Analysis

Statistical analysis was performed to establish comparisons between pre- and postoperative measurements in relation to clinical and radiological data and criteria, using the Student t test, the chi-squared test, the Mann-Whitney test, or the Fischer exact test. The Shapiro Wilk normality test was used. Survival analysis of the acetabular component was performed using the Kaplan-Meier method with radiographic data. A significant value was considered when p < 0.05, with 95% confidence interval (CI). IBM SPSS Statistics for Windows, version 27.0 (IBM Corp., Armonk, NY, USA) was used for data analysis.

Results

Forty patients (44 hips), with a mean follow-up of9.65 years (2 to 18.75 years) were evaluated. In 39 initial patients of the series (88.66%), a conventional cemented acetabular component (noncrosslinked) was used.

Regarding clinical results, the mean preoperative Harris Hip Score (HHS)1313 Guimaraes RP, Alves DPL, Silva GB, et al. Translation and cultural adaptation of the Harris Hip Score into Portuguese. Acta Ortop Bras 2010;18(03):142-147 was 48.8 points, and in the late postoperative period it was 82. Comparatively, a statistically significant difference was observed (p < 0.001).

Of the 44 operated cases, 20 acetabular defects (45.5%) were classified as Paprosky type 3A1414 Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 1994;9(01):33-44 and 22 (50%) as type 3B. According to the classification by D'Antonio,1212 D'Antonio JA, Capello WN, Borden LS, et al. Classification and management of acetabular abnormalities in total hip arthro-plasty. Clin Orthop Relat Res 1989;(243):126-137 39 combined defects (88.6%) were observed. The size of the bone defect in millimeters66 Roos MV, Roos BD, Sampaio CM, Marques PR Junior. Evaluation of a method of acetabular reconstruction using homologous bone graft and cemented implant. Rev Bras Ortop 2008;43(09): 367-375 was on average 62.48 mm. The radiographic characteristics of the patients are described in Table 2.

Table 2
Radiographic characteristics of patients

The percentage of mean coverage of the implant cemented by the graft was 77% (43 to 100%), and in 41 cases (93.18%) > 50% coverage was evidenced. The largest cranio-caudal thickness of the graft was on average 2.2 mm (1.2 to 4.6 mm). In 29 hips (65%), the graft configuration was classified as Prieto type 1 (footing), and in 14 (31%) as type 2 (dome support).

Postoperatively, no radiographic evidence of osseointe-gration was observed in 6 (13.6%) cases (Coon 31515 da Silva AF, Antebi U, Honda EK, Rudelli M, Guimarães RP. Comparative Study of the Osteointegration of Irradiated and Non-irradiated Bone Grafts Used in Patients with Revision Hip Arthroplasty. Rev Bras Ortop 2019;54(04):477-482). In 14 hips (26%), partial graft reabsorption was observed, all in DeLee zone 1.1616 DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976; (121):20-32 In 8 cases (18.2%), the presence of osteolysis was evidenced, all in DeLee zone 3.1616 DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976; (121):20-32

Progressive radiolucency lines > 2 mm wide were observed around the acetabular implant in 9 cases. Of these, in 8 cases, migration > 5 mm was evidenced. According to the radiographic criteria established, 9 cases (20.5) were considered reconstruction failures. Five (11.5%) of these patients were resubmitted to revision surgery, one of whom had an infection. Of the 9 cases of failure, no osseointegration of the graft was observed in 6 cases (►Figs. 1 and 2).

Fig. 1
Radiographs of a 73-year-old female patient who had her right hip operated. A) preoperative radiography showing noncemented total hip arthroplasty with combined defect (D'Antonio); Paprosky 3B, measuring 82 mm; B) immediate postoperative radiography presenting acetabular reconstruction with structural graft and cemented acetabular component; C) postoperative radiography at 10 years and 6 months after acetabular reconstruction without signs of release.

Fig. 2
Radiographs of a 63-year-old female patient who had her right hip operated. A) preoperative radiography showing cemented total hip arthroplasty with pelvic discontinuity; Paprosky 3B, measuring 80 mm; B) immediate postoperative radiography presenting acetabular reconstruction with structural graft and cemented acetabular component; C) postoperative radiography at 3 years and 1 month after acetabular reconstruction with signs of loosening.

Using radiographic criteria to define failure, we found a 79.54% survival rate in a mean follow-up of 9.65 years. When the criterion was used for a new surgery to review the acetabular component for any reason, survival was 88.63%. As complications, we observed 4 cases (9.09%) of instability and 1 (2.27%) of infection.

The survival of the reconstruction was evaluated through the Kaplan-Meier curve, being 92.1% in 5 years and 78.3% in 10 years, when the radiographic parameters of failure were used. The 5- and 10-year survival free of new acetabular component revision surgery for any reason as an outcome was 94.4 and 83.2%, respectively (►Fig. 3).

Fig. 3
Kaplan-Meier curves for reconstruction survival without revision for: (A) acetabular loosening (92.1% in 5 years, 78.3% in 10 years, and 67.5% in 15 years) or (B) any cause (94.4% in 5 years and 83.2% in 10 and 15 years).

A correlation was observed between migration and reconstruction failure, with the absence of radiographic signs of graft osseointegration (p < 0.01). There were 5 cases with complications: 4 with instability (9.09%) and 1 (2.27%) with infection.

Discussion

In the present study, most patients had large acetabular defects; 90.9% of the defects were classified as Type III or IVof D'Antonio and 95.5% as Paprosky type 3A or 3B. A correlation was observed between reconstruction failure and absence of radiographic signs of graft osseointegration (p< 0.01). Patients with radiographic signs of failure showed significantly worse postoperative scores than the other patients.

Acetabular reconstruction in the presence of severe ace-tabular bone deficiency is a challenging scenario in hip revision surgery. Acetabular reconstruction techniques using structural bone graft allow restoring the center of hip rotation, obtaining implant stability, with the possibility of restoration of bone stock, facilitating future revisions.1818 Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res 2004;(429): 201-208

Acetabular reconstruction using a structural homologous graft in THAR presents controversial results in the litera-ture.1111 Kwong LM, Jasty M, Harris WH. High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 years. J Arthroplasty 1993;8(04):341-346, 1818 Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res 2004;(429): 201-208, 1919 van Haaren EH, Heyligers IC, Alexander FGM, Wuisman PIJM. High rate of failure of impaction grafting in large acetabular defects. J Bone Joint Surg Br 2007;89(03):296-300 Prieto et al.22 Prieto HA, Kralovec ME, Berry DJ, Trousdale RT, Sierra RJ, Cabanela ME. Structural allograft supporting a trabecular metal cup provides durable results in complex revision arthroplasty. J Arthro-plasty 2017;32(11):3488-3494 found 94% survival in noncemented implants with high porosity metal associated with the use of structural allograft in 5 years of follow-up. Brown et al., using structural allograft of distal femur associated with nonce-mented implant, observed 72% survival in 21 years of mean follow-up.2020 Brown NM, Morrison J, Sporer SM, Paprosky WG. The Use of Structural Distal Femoral Allograft for Acetabular Reconstruction of Paprosky Type IIIA Defects at a Mean 21 Years of Follow-Up. J Arthroplasty 2016;31(03): 680-683 Garbuz et al.2121 Garbuz D, Morsi E, Gross AE. Revision of the acetabular component ofa total hip arthroplastywith a massive structural allograft. Study with a minimum five-year follow-up. J Bone Joint Surg Am 1996;78(05):693-697 evaluated 33 cases of acetabular reconstruction with structural graft supporting > 50% of the implant, in a mean follow-up of 7 years. A 45% failure was observed, which occurred mainly in cases in which no reinforcement ring was used.

Butscheidt et al.,55 Butscheidt S, Moritz M, Gehrke T, et al. Incorporation and Remodeling of Structural Allografts in Acetabular Reconstruction: Multiscale, Micro-Morphological Analysis of 13 Pelvic Explants. J Bone Joint Surg Am 2018;100(16):1406-1415 analyzed 13 structural homologous grafts after death by radiography, computed tomography (CT), histology, and electron microscopy. The distance between the current allograft and the host bone, and the distance between the original allograft and the host bone were evaluated. The study observed adequate osseointegra-tion of all grafts along most of the interface between the graft and the host bone. The eventual nonosseointegration in some points did not lead to graft collapse within 22 years of follow-up.55 Butscheidt S, Moritz M, Gehrke T, et al. Incorporation and Remodeling of Structural Allografts in Acetabular Reconstruction: Multiscale, Micro-Morphological Analysis of 13 Pelvic Explants. J Bone Joint Surg Am 2018;100(16):1406-1415

The literature indicates a higher incidence of reconstruction failure when using a structural graft with > 50% ace-tabular implant coverage, which we did not evidence in the present series even without the use of reinforcement ring.1010 Hooten JP Jr, Engh CA Jr, Engh CA. Failure of structural acetabular allografts in cementless revision hip arthroplasty. J Bone Joint Surg Br 1994;76(03):419-422,1111 Kwong LM, Jasty M, Harris WH. High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 years. J Arthroplasty 1993;8(04):341-346,2222 Zmolek JC, Dorr LD. Revision total hip arthroplasty. The use of solid allograft. J Arthroplasty 1993;8(04):361-370 The patient with the longest follow-up time (18.75 years) has no signs of release or failure so far (►Fig. 4).

Fig. 4
Radiographs of a 74-year-old female patient who had her right hip operated. A) preoperative radiography showing cemented total hip arthroplasty with combined defect (D'Antonio); Paprosky 3A, measuring 74 mm; B) immediate postoperative radiography presenting acetabular reconstruction with structural graft and cemented acetabular component; C) postoperative radiography at 18 years and 9 months after acetabular reconstruction without signs of loosening.

Total hip arthroplasty revision in the presence of severe acetabular defects is more challenging and may have worse results. In the present study, with the analysis of the treatment of large bone defects, however, we did not observe a correlation between reconstruction failure and severity of the acetabular bone defect, graft thickness or configuration.

Our study has some limitations. We observed a good time of mean follow-up of the patients (9.65 years); however, we had a considerable loss of follow-up, which made it impossible to find more conclusions. Moreover, as the series of patients is old and there was no local availability of acetabu-lar implant cemented with crosslinked polyethylene, it should be considered that the use of conventional polyethylene in most cases may have compromised the survival of reconstruction due to early wear. We suggest future research to evaluate the osseointegration of the structural graft using only one type of cemented prosthetic implant, aiming to reduce confounding factors.

Conclusion

We observed good clinic and radiographic results, with survival of 79.54% in a mean follow-up of 9.65 years. There was an association between absence of radiographic signs of osseointegration of the structural graft and failure of acetab-ular THAR in the present series of patients with large bone defects. The failures did not correlate with the severity of the acetabular bone defect, thickness, or graft configuration.

References

  • 1
    Meneghini RM, Ford KS, McCollough CH, Hanssen AD, Lewallen DG. Bone remodeling around porous metal cementless acetabular components. J Arthroplasty 2010;25(05):741-747
  • 2
    Prieto HA, Kralovec ME, Berry DJ, Trousdale RT, Sierra RJ, Cabanela ME. Structural allograft supporting a trabecular metal cup provides durable results in complex revision arthroplasty. J Arthro-plasty 2017;32(11):3488-3494
  • 3
    Stigbrand H, Gustafsson O, Ullmark G. A 2- to 16-Year Clinical Follow-Up of Revision Total Hip Arthroplasty Using a New Acetabular Implant Combined With Impacted Bone Allografts and a Cemented Cup. J Arthroplasty 2018;33(03):815-822
  • 4
    Guimarães RP, Yonamine AM, Faria CEN, Rudelli M. Is the size of the acetabular bone lesion a predictive factor for failure in revisions of total hip arthroplasty using an impacted allograft? Rev Bras Ortop 2016;51(04):412-417
  • 5
    Butscheidt S, Moritz M, Gehrke T, et al. Incorporation and Remodeling of Structural Allografts in Acetabular Reconstruction: Multiscale, Micro-Morphological Analysis of 13 Pelvic Explants. J Bone Joint Surg Am 2018;100(16):1406-1415
  • 6
    Roos MV, Roos BD, Sampaio CM, Marques PR Junior. Evaluation of a method of acetabular reconstruction using homologous bone graft and cemented implant. Rev Bras Ortop 2008;43(09): 367-375
  • 7
    Roos MV, Roos BD, Giora TS, Taglietti TM. Use ofcortical structural homologous bone graft in femoral reconstructive surgery. Rev Bras Ortop 2015;45(05):483-489
  • 8
    Roos BD, Roos MV, Camisa A Jr. Circumferential proximal femoral allografts in revision hip arthroplasty: four to 20 years follow-up. Hip Int 2013;23(01):66-71
  • 9
    Gerhardt DMJM, De Visser E, Hendrickx BW, Schreurs BW, Van Susante JLC. Bone mineral density changes in the graft after acetabular impaction bone grafting in primary and revision hip surgery. Acta Orthop 2018;89(03):302-307
  • 10
    Hooten JP Jr, Engh CA Jr, Engh CA. Failure of structural acetabular allografts in cementless revision hip arthroplasty. J Bone Joint Surg Br 1994;76(03):419-422
  • 11
    Kwong LM, Jasty M, Harris WH. High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 years. J Arthroplasty 1993;8(04):341-346
  • 12
    D'Antonio JA, Capello WN, Borden LS, et al. Classification and management of acetabular abnormalities in total hip arthro-plasty. Clin Orthop Relat Res 1989;(243):126-137
  • 13
    Guimaraes RP, Alves DPL, Silva GB, et al. Translation and cultural adaptation of the Harris Hip Score into Portuguese. Acta Ortop Bras 2010;18(03):142-147
  • 14
    Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 1994;9(01):33-44
  • 15
    da Silva AF, Antebi U, Honda EK, Rudelli M, Guimarães RP. Comparative Study of the Osteointegration of Irradiated and Non-irradiated Bone Grafts Used in Patients with Revision Hip Arthroplasty. Rev Bras Ortop 2019;54(04):477-482
  • 16
    DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976; (121):20-32
  • 17
    Knight JL, Fujii K, Atwater R, Grothaus L. Bone-grafting for acetabular deficiency during primary and revision total hip arthroplasty. A radiographic and clinical analysis. J Arthroplasty 1993;8(04):371 -382
  • 18
    Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res 2004;(429): 201-208
  • 19
    van Haaren EH, Heyligers IC, Alexander FGM, Wuisman PIJM. High rate of failure of impaction grafting in large acetabular defects. J Bone Joint Surg Br 2007;89(03):296-300
  • 20
    Brown NM, Morrison J, Sporer SM, Paprosky WG. The Use of Structural Distal Femoral Allograft for Acetabular Reconstruction of Paprosky Type IIIA Defects at a Mean 21 Years of Follow-Up. J Arthroplasty 2016;31(03): 680-683
  • 21
    Garbuz D, Morsi E, Gross AE. Revision of the acetabular component ofa total hip arthroplastywith a massive structural allograft. Study with a minimum five-year follow-up. J Bone Joint Surg Am 1996;78(05):693-697
  • 22
    Zmolek JC, Dorr LD. Revision total hip arthroplasty. The use of solid allograft. J Arthroplasty 1993;8(04):361-370
  • Work developed in the Department of Orthopedics and Traumatology, Hospital Ortopédico de Passo Fundo, Passo Fundo, RS, Brazil.
  • Financial Support
    The present study did not receive any financial support from either public, commercial or not-for-profit sources.

Publication Dates

  • Publication in this collection
    24 July 2023
  • Date of issue
    May-Jun 2023

History

  • Received
    20 July 2022
  • Accepted
    4 Oct 2022
Sociedade Brasileira de Ortopedia e Traumatologia Al. Lorena, 427 14º andar, 01424-000 São Paulo - SP - Brasil, Tel.: 55 11 2137-5400 - São Paulo - SP - Brazil
E-mail: rbo@sbot.org.br