Acessibilidade / Reportar erro

Proteção medular em cirurgia da aorta descendente com uso de "bio-pump" e exsangüinação controlada

Spinal protection during descending aortic surgery

Resumos

Os autores utilizam como método de proteção medular em cirurgia de aorta descendente, circulação extracorpórea átrio esquerdo-femoral esquerda, com baixa dose de heparina (1 mg/kg), bomba centrífuga (bio-pump) e exsangüinação controlada. Operaram 4 doentes com esta metodologia sem que houvesse mortalidade, paraplegia ou sangramento excessivo.

proteção medular em cirurgia de aorta; circulação extracorpórea; exsangüinação


The authors have used for spinal cord protection during descending aortic surgery, partial extracorporeal circulation from left atrium to left femoral artery, low dose of heparin (1 mg/kg), centrifugal pump (bio-pump) and controlled exsanguination. They have operated upon with this methodology 4 patients without mortality, paraplegia or excessive bleeding.

spinal protection in aortic surgery; extracorporeal circulation; exsanguination


ARTIGOS ORIGINAIS

Proteção medular em cirurgia da aorta descendente com uso de "bio-pump" e exsangüinação controlada

Spinal protection during descending aortic surgery

Henrique MuradIII; José L. FeitosaI; Rubens Giambroni FilhoIII; José Augusto de AzevedoIII; João de Deus e BritoI; Márcia S. PalharesI; Eliane C. GomesI; Francisco José do NascimentoIII; Diniz Alves de OliveiraIII; Maria Elisa G. FonsecaII; Amauri Dias do CoutoII; Mauro Paes Leme de SáI; Juscileide M. de Araújo PiresI

IDo Hospital Universitário Clementino Fraga Filho

IIDo Hospital São Vicente de Paulo

IIIDo Hospital Universitário Clementino Fraga Filho e do Hospital São Vicente de Paulo

Endereço para correspondência Endereço para correspondência: Henrique Murad Rua Oto de Alencar, 15, aptº. 302 CEP: 20271-220 Rio de Janeiro, RJ, Brasil

RESUMO

Os autores utilizam como método de proteção medular em cirurgia de aorta descendente, circulação extracorpórea átrio esquerdo-femoral esquerda, com baixa dose de heparina (1 mg/kg), bomba centrífuga (bio-pump) e exsangüinação controlada. Operaram 4 doentes com esta metodologia sem que houvesse mortalidade, paraplegia ou sangramento excessivo.

Descritores: proteção medular em cirurgia de aorta; circulação extracorpórea; exsangüinação.

ABSTRACT

The authors have used for spinal cord protection during descending aortic surgery, partial extracorporeal circulation from left atrium to left femoral artery, low dose of heparin (1 mg/kg), centrifugal pump (bio-pump) and controlled exsanguination. They have operated upon with this methodology 4 patients without mortality, paraplegia or excessive bleeding.

Descriptors: spinal protection in aortic surgery; extracorporeal circulation; exsanguination.

Texto completo disponível apenas em PDF.

Full text available only in PDF format.

Trabalho realizado no Serviço de Cirurgia do Hospital Universitário Clementino Fraga Filho da Universidade Federal do Rio de Janeiro e no Serviço de Cirurgia Cardíaca do Hospital São Vicente de Paulo. Rio de Janeiro, RJ, Brasil.

Apresentado ao 21º Congresso Nacional de Cirurgia Cardíaca. Porto Alegre, RS, 24 a 26 de março, 1994.

  • 1 BERKOFF, H. A. & FOLLETTE, D. A. - Paraplegia associated with thoracic aortic surgery. Chest Surg. Clin. N. Am, 2: 379-381, 1992.
  • 2 CARPENTIER, A.; DELOCHE, A.; FABIANI, J. N.; et al.: New surgical approach to aortic dissection: flow reversal and tromboexclusion. J. Thorac. Cardiovasc. Surg, 81: 659-668, 1981.
  • 3 CERNAIANU, A. C; OLAH, A.; CILLEY Jr., J. H. et al.: Effect of sodium nitroprusside on paraplegia during cross-clamping of the thoracic aorta. Ann. Thorac. Surg, 56: 1035-1037, 1993.
  • 4 CONNOLLY. J. E. - Prevention of paraplegia secondary of operation on the aorta. J. Cardiovasc. Surg, 27: 410-415, 1986.
  • 5 COSELLI, J. S. - Descending/ Thoracic Abdominal Repair. Aortic Surgery Symposium, 3. New York, Futura Publishing Co., 1992.
  • 6 CRAWFORD, E. S.; SVENSSON. L. G.; HESS. K. R. - A prospective randomized study of cerebrospinal fluid drainage to prevent paraplegia after high-risk surgery on the thoracoabdominal aorta. J. Vasc Surg, 13: 36-45, 1991.
  • 7 CUNNINGHAM, J. N. - Spinal cord protection during thoracic aortic surgery. Aortic Surgery. Symposium, 3. New York, abril 1992.
  • 8 ERGIN, M. A. - Descending aneurysm: methods of protection. Aortic Surgery Symposium, 3. New York, april, 1992.
  • 9 GLOWER, D. D.; SPEIER, R. F.; WHITE, W. D.; et al.: Management and long term outcome of aortic dissection. Ann. Surg, 214: 31-41, 1991.
  • 10 KIEFFER, E.; RICHARD, T.; CHICAS, J.; et al.: Preoperative spinal cord arteriography in aneurysmal disease of the descending thoracic and thoracoabdominal aorta: preliminary results in 45 patients. Ann. Vasc. Surg, 3: 34-39, 1989.
  • 11 LASCHINGER, J. C.; CUNNINGHAM Jr., J. N.; COOPER, M. M.; et al.: Prevention of ischemic spinal cord injury following aortic cross-clamping. Use Of corticosteroids. Ann. Thorac. Surg, 38: 500-507, 1984.
  • 12 MILLER, D. C. - The continuing dilema concerning medical versus surgical management of patients with acute type 3 dissections. Sem. Thorac. Cardiovasc. Surg, 5: 33-46, 1993.
  • 13 MURAD, H. - Estudo dos métodos para prevenir isquemia medular em cirurgia da aorta descendente. Rio de Janeiro, RJ, 1992. [Tese. Mestrado. Universidade Federal do Rio de Janeiro]
  • 14 MYHRE, H. O.; SAETHER, O. D.; STENSETH, R. - Attempts to reduce paraplegia risk. In: Aortic surgery in the cause and management of aneurysms. GREENHALGH, R. M. & MANICK, J. A. (eds.) W. B. Saunders Co., London, 1990. p. 373-385.
  • 15 PALMA, H.; JULIANO, J. A.; CAL, R. G. R.; ALMEIDA, D. R.; OTA, L. H.; GIANOTTI, I. A.; ANDADE, J. C. S.; BUFFOLO, E. - Tratamento dos aneurismas da aorta descendente por endoprótese (tromba de elefante). Rev. Bras. Cir. Cardiovasc, 4: 190-194, 1989.
  • 16 SVENSON, L. G. & CRAWFORD, E. S. - Aortic dissection and aortic aneurysm surgery: clinical observations, experimental investigations and statistical analysis. Part I. Curr. Probl. Surg, 29 (11): 817-911, 1992.
  • 17 SVENSON, L. G. & CRAWFORD, E. S. - Aortic dissection and aortic aneurysm surgery: clinical observations, experimental investigations and statistical analysis. Part III. Curr. Probl. Surg, 30 (1): 1-163, 1993.
  • 18 SVENSON, L. G.; CRAWFORD, E. S.; HESS, K. R.; et al.: Dissection of the aorta and dissecting aneurysms: improving early and long-term surgical results. Circulation, 82 (Supl. 4): 24-38, 1990.
  • Endereço para correspondência:

    Henrique Murad
    Rua Oto de Alencar, 15, aptº. 302
    CEP: 20271-220 Rio de Janeiro, RJ, Brasil
  • Datas de Publicação

    • Publicação nesta coleção
      17 Fev 2011
    • Data do Fascículo
      Jun 1994
    Sociedade Brasileira de Cirurgia Cardiovascular Rua Afonso Celso, 1178 Vila Mariana, CEP: 04119-061 - São Paulo/SP Brazil, Tel +55 (11) 3849-0341, Tel +55 (11) 5096-0079 - São Paulo - SP - Brazil
    E-mail: bjcvs@sbccv.org.br