Endovascular approach for persistent ductus arteriosus closure in adult patient

Abstracts

The treatment for closure of persistent ductus arteriosus (PDA) in adults still controversial. The endovascular approach has been shown as an effective alternative to surgical treatment. We report a case of 45 years old pacient submitted to endovascular approach for PDA closure.

Ductus arteriosus; Heart Defects, congenital; Ductus arteriosus, patent


O tratamento da Persistência do Canal Arterial (PCA), em adultos, ainda é controverso. A utilização de próteses auto-expansíveis tem-se mostrado como uma alternativa eficaz ao tratamento cirúrgico. Apresentamos um caso de uma paciente de 45 anos submetida ao tratamento endovascular com o uso de stent auto-expansível.

Canal arterial; Cardiopatias congênitas; Permeabilidade do canal arterial


CASE REPORT

Endovascular approach for persistent ductus arteriosus closure in adult patient

José Carlos Dorsa Vieira PontesI; Guilherme Viotto Rodrigues da SilvaII; Amaury Edgardo Mont'Serrat Ávila Souza DiasIII; Ricardo Adala BenfattiIV

IPhD; Director of Clinical Surgery Dept.- UFMS

IIGraduate in Medicine - UFMS; Graduate in Medicine - UFMS

IIISpecialist; Thoracic Surgery Professor - UFMS

IVMaster's Degree; Thoracic Surgery Professor - UFMS

Correspondence address

ABSTRACT

The treatment for closure of persistent ductus arteriosus (PDA) in adults is still controversial. The endovascular approach has been shown as an effective alternative to the surgical treatment. We report a case of a 45 year-old patient submitted to endovascular approach for PDA closure.

Descriptors: Ductus arteriosus. Heart Defects, congenital. Ductus arteriosus, patent.

INTRODUCTION

The Persistent Ductus Arteriosus has frequent incidence, especially in premature children, and its correction is simple when performed in childhood [1]. When diagnosed in adulthood, the surgical correction of PDA becomes controversial, when the surgical procedure may be of highrisk due to the characteristics of the channel. The conventional surgical treatment depends on the clinical conditions of the patient, regarding the standard of pulmonary flow and anatomical characteristics of the very own ductus arteriosus. The endovascular treatment of aortic diseases made possible the application of the technique to congenital heart diseases, among them the PDA which, besides offering the possibility of satisfactory results, exposes the patient to lower transoperative risks, once it is a less invasive procedure. The technique has been reported by authors as being an efficient and safe alternative to the surgical treatment [2,3].

CASE REPORT

Patient, 45 years-old, female, admitted at the Hospital Universitário da UFMS complaining of progressive dyspnea, functional class III - New York Heart Association (NYHA). In the physical examination, she presented murmur near the left sternal border. In the thoracic X-ray it was observed an increase of the pulmonary artery trunk and increase of pulmonary circulation. The patient was submitted to transesophagic Doppler echocardiogram that showed the presence of a ductus arteriosus of 5 mm of diameter (Figure 1), discrete overload of the left ventricle and pulmonary hyperflow with gradient of 70 mmHg. In the hemodynamic study, the systolic and diastolic aortic pressures were, respectively, 107 mmHg and 54 mmHg; the systolic and diastolic pulmonary pressures were 20 mmHg and 76 mmHg, respectively; the pulmonary arteriography evidenced dilatation of the pulmonary artery with the pulmonary valve, allowing back-flow of a small contrast volume to the right ventricle.


After approval by the Ethics Committee of the NHU (Núcleo de Hospital Universitário da UFMS) and Term of Agreement signed by the patient, she was submitted to general anesthesia and oral-tracheal intubation, dorsal horizontal position, cardioscopy, pulse oxymetry, non invasive monitoring of blood pressure and vesicle probing.

Local inguinal bilateral antisepsis, dissection and repair of the right femoral artery. After complete heparinization of the patient it was performed the aortography, finding the PDA by means of radioscopy. Insertion of a self-expansive stent (34 mm in diameter and 9 cm in length - Braile Biomédica, São José do Rio Preto-SP), after marking the exact location of the left subclavian artery and the ductus. Positioning of the prosthesis, in order to occlude the ductus arteriosus, without, nevertheless, occluding the left subclavian artery. Performance of a new aortography observing the absence of aortopulmonary shunt.

There were no intercurrences in the postoperative evolution, being the patient extubated in the surgery room and released from hospital in the third day after the procedure. The radiography and computerized tomography of thorax evidenced adequate positioning of the endoprosthesis. After two months of the procedure, the FC evoluted to I - NYHA and the transesophagic echocardiogram showed absence of residual shunts and return of the cardiac parameters to normal (Figure 2). The patient started follow-up every six months without the use of any medication.


DISCUSSION

The persistence of ductus arteriosus is mostly diagnosed in childhood, being its treatment relatively simple, performing a duct ligation. In adults, the persistence of left-right shunt is associated with pulmonary hypertension and chronical ventricular dysfunction [3].

Maurice et al. describe a predisposition to bacterial endocarditis, being that by the age of 45 years; around 42% of the patients will have already died [4].

Bakir et al. [2] report that due to factors such as fragility and calcification of the aortic wall, besides the presence of possible aneurysms, the surgical treatment in adulthood is of high-risk and controversial.

Due to pulmonary high blood pressure, the risk of surgical occlusion increases even more when using hypothermia, according to Lai et al. [5].

Roques et al. [6] in 2001, reported the first case of endovascular correction of PDA, characterizing a simple and safe technique, proposed for the occlusion of the persistence of a calcified and aneurysmatic ductus arteriosus.

According to the available literature, the use of selfexpansive prosthesis for the endovascular treatment of PDA has proven very promising. However, the referrals must be discussed, since the system used to insert the prosthesis requires a minimum size of the artery and the distance between the PDA and the left subclavian artery must be a minimum of 15 mm, in order to assure efficiency and safety to the procedure [3].

In this report, the endovascular treatment for closure of persistent ductus arteriosus in adults proved to be a simple and safe alternative, becoming perhaps a procedure of choice in these types of patients.

REFERENCES

  • 1. Gaia DF, Palma JH, Kim HC, Souza JA, Alves CR, Buffolo E. Patent ductus arteriosus: endovascular treatment in adult patient. Arq Bras Cardiol. 2008;91(2):25-7.
  • 2. Bakir I, Degrieck I, Lecomte P, Coddens J, Foubert L, Heyse A, et al. Endovascular treatment of concomitant patent ductus arteriosus and type B aortic dissection in a patient with pulmonary artery dissection. J Thorac Cardiovasc Surg. 2006;132(2):438-40.
  • 3. Muñoz JJ, Urbaneja A, Gonzalez N, Martinez JL. Adult patent ductus arteriosus: treatment with a stent-graft. Cardiovasc Intervent Radiol. 2008;31(2):383-5.
  • 4. Campbell M. Natural history of persistent ductus arteriosus. Br Heart J. 1968;30(1):4-13.
  • 5. Lai YQ, Xu SD, Li ZZ, Yang BZ, Wang S, Li JH, et al. Thoracic endovascular aortic repair of adult patent ductus arteriosus with pulmonary hypertension. J Thorac Cardiovasc Surg. 2008;135(3):699-701.
  • 6. Roques F, Hennequin JL, Sanchez B, Ridarch A, Rousseau H. Aortic stent-graft for patent ductus arteriosus in adults: the aortic exclusion technique. Ann Thorac Surg. 2001;71(5):1708-9.
  • Endereço para correspondência:
    José Carlos Dorsa Vieira Pontes
    Universidade Federal do Mato Grosso do Sul. Departamento de Clínica Cirúrgica
    Av. Senador Filinto Muller, s/n
    Campo Grande, MS, Brasil
    E-mail:
  • Publication Dates

    • Publication in this collection
      19 July 2010
    • Date of issue
      Mar 2010

    History

    • Reviewed
      06 Oct 2009
    • Received
      07 June 2009
    Sociedade Brasileira de Cirurgia Cardiovascular Rua Afonso Celso, 1178 Vila Mariana, CEP: 04119-061 - São Paulo/SP Brazil, Tel +55 (11) 3849-0341, Tel +55 (11) 5096-0079 - São Paulo - SP - Brazil
    E-mail: bjcvs@sbccv.org.br