Acessibilidade / Reportar erro

First Two Brazilian Cases: Correction of Ascending Aortic Aneurysm and Aortic Valve Stenosis with Sutureless/Rapid Deployment Aortic Prosthesis

Abstract

Ascending aortic aneurysm is usually associated with aortic valve diseases, especially aortic stenosis. The standard technique involves the substitution of the dilated aortic segment with a Dacron tube and replacement of the aortic valve with a regular prosthesis. The correction of ascending aortic aneurysm with aortic valve replacement using the new sutureless and rapid deployment prosthesis was performed by a minimally invasive approach and for the first time in a Brazilian Center.

Keywords:
Aortic Valve - Surgery; Heart Valve Prosthesis; Treatment Outcome

Authors' roles & responsibilities IAS Wrote the paper; final approval of the version to be published RBC Reviewed and performed critical analysis; final approval of the version to be published MVNS Reviewed and performed critical analysis; final approval of the version to be published HJBS Reviewed and performed critical analysis; final approval of the version to be published GKSP Reviewed and performed critical analysis; final approval of the version to be published

INTRODUCTION

The association between aortic valve dysfunction and dilatation of the ascending aorta is well known[11 Cotrufo M, Agozzino L, De Feo M, Della Corte A, De Santo LS, et al. Aortic valve dyfunction and dilated ascending aorta. A complex and controversial association. Ital Heart J [Internet]. 2003 [cited 2019 Apr 30];4(9):589-95. Available from: http://www.federcardio.it/pdf/2003/09/20030206.pdf.
http://www.federcardio.it/pdf/2003/09/20...
] and the treatment usually involves the aortic valve replacement with substitution of the dilated aortic segment. Sometimes, a total ascending aortic segment needs to be treated in addiction of a valve replacement, (Bentall De Bono) but an aortic-root-sparing approach may be feasible when there is no sinus dilatation[22 Peterss S, Charilaou P, Dumfarth J, Li Y, Bhandari R, Tranquilli M, et al. Aortic valve disease with ascending aortic aneurysm: impact of concomitant rootsparing (supracoronary) aortic replacement in nonsyndromic patients. J Thorac Cardiovasc Surg. 2016;152(3):791-798. doi:10.1016/j.jtcvs.2016.05.020.
https://doi.org/10.1016/j.jtcvs.2016.05....
]. In this new era of sutureless and rapid deployment prosthesis, a root-sparing ascending aortic replacement with modern prosthesis has been described with good results[33 Lio A, Ferrarini M, Miceli A, Glauber M. Sutureless prosthesis implantation and ascending aorta replacement through a ministernotomy approach. Innovations (Phila). 2018;13(3):239-41. doi:10.1097/IMI.0000000000000479.
https://doi.org/10.1097/IMI.000000000000...
]. Here, we describe our initial two cases, for the first time performed in Brazil.

CASE REPORT

Case 1

A 62-year-old male patient, with no history of comorbidities, presented with functional capacity reduction and complained of dyspnea on greater efforts of progressive worsening. Coronary angiography showed no obstructive lesions in coronary arteries.

Echocardiogram: EF 73%; Left atrium 37ml/m2; Aortic valve area 1.0cm2; maximum gradient 81 mmHg and medium gradient 51 mmHg; Pulmonary artery systolic pressure 33 mmHg; mitral valve without abnormalities.

Angiotomography: root 35mm; tubular thread ascending 47mm; arch 42mm; isthmus 25mm; descending 22mm.

He was submitted to an aortic valve replacement + replacement of the ascending aorta by the minimally invasive technique (mini-sternotomy in J). Briefly, under cardiopulmonary bypass, the distal ascending aorta was cross clamped. After anterior oblique aortotomy, a calcified and stenotic tricuspid aortic valve was found. Del Nido cardioplegia was delivered directly in coronary ostia. Resection of the entire dilated aortic segment was performed and a Dacron™ tube number 34 was sutured above the coronary ostia and a biological sutureless aortic valve (Perceval™ XL LivaNova) was implanted. Cross clamp time: 81 min. Total cardiopulmonary bypass time was 95 min.

Intraoperative transesophageal echocardiogram demonstrated normofunction of the valvular prosthesis, no paravalvular leak and a mean gradient of 3 mmHg.

Case 2

A 61-year-old male patient, with a history of hypertension and a long-term heart murmur accompanied of recent onset of dizziness and dyspnea. Echocardiogram showed severe aortic stenosis and ascending aortic aneurysm. Angiotomography showed ascending aorta with 48 mm diameter. Coronary cardiac catheterization with irregularities and severe aortic stenosis, with a systolic gradient of 80 mmHg.

He was submitted to aortic valve replacement + replacement of the ascending aorta by the minimally invasive technique (ministernotomy in J). Under cardiopulmonary bypass an anterior oblique aortotomy was performed. A type 1 bicuspid aortic valve was found, full of calcium and very stenotic. Del Nido cardioplegia was delivered directly in coronary ostia. Resection of the entire dilated aortic segment was performed and a Dacron tube number 32 was sutured above the coronary ostia and a biological rapid deployment valve (Intuity™ 25 Edwards) was implanted. Cross clamp time: 80 min. Total cardiopulmonary bypass time was 96 min.

Intraoperative transesophageal echocardiogram demonstrated preserved biventricular function, well positioned prosthesis, no paravalvular leak, mean gradient of 4 mmHg.

Both patients had an uneventful recovery and are doing well.

DISCUSSION

Aortic surgeries with aortic valve replacement are commonly time-consuming procedures. The use of available sutureless and rapid deployment valves have resulted in an important cross-clamp and by-pass time reduction[44 Miceli A, Santarpino G, Pfeiffer S, Murzi M, Gilmanov D, Concistré G, et al. Minimally invasive aortic valve replacement with perceval S sutureless valve: early outcomes and one-year survival from two European centers. J Thorac Cardiovasc Surg. 2014;148(6):2838-43. doi:10.1016/j.jtcvs.2014.02.085.
https://doi.org/10.1016/j.jtcvs.2014.02....
]in comparison with regular valves, at least in valve replacement procedures. Lio et al.[33 Lio A, Ferrarini M, Miceli A, Glauber M. Sutureless prosthesis implantation and ascending aorta replacement through a ministernotomy approach. Innovations (Phila). 2018;13(3):239-41. doi:10.1097/IMI.0000000000000479.
https://doi.org/10.1097/IMI.000000000000...
] reported successful utilization of non-conventional valves in combined surgeries (aorta and aortic valve) with reasonable time sparing. Considering the full regulatory acceptance, the growing utilization of these valves around the world and, especially because of their comfortable implantation, complex procedures can be performed in a simpler way. In our cases, the minimally invasive technic was applied, cross-clamp and by-pass time were reasonable, and the results were very good.

  • This study was carried out at the Cardiovascular Associados, Brasilia, DF, Brazil.
  • No financial support.

REFERENCES

  • 1
    Cotrufo M, Agozzino L, De Feo M, Della Corte A, De Santo LS, et al. Aortic valve dyfunction and dilated ascending aorta. A complex and controversial association. Ital Heart J [Internet]. 2003 [cited 2019 Apr 30];4(9):589-95. Available from: http://www.federcardio.it/pdf/2003/09/20030206.pdf
    » http://www.federcardio.it/pdf/2003/09/20030206.pdf
  • 2
    Peterss S, Charilaou P, Dumfarth J, Li Y, Bhandari R, Tranquilli M, et al. Aortic valve disease with ascending aortic aneurysm: impact of concomitant rootsparing (supracoronary) aortic replacement in nonsyndromic patients. J Thorac Cardiovasc Surg. 2016;152(3):791-798. doi:10.1016/j.jtcvs.2016.05.020.
    » https://doi.org/10.1016/j.jtcvs.2016.05.020
  • 3
    Lio A, Ferrarini M, Miceli A, Glauber M. Sutureless prosthesis implantation and ascending aorta replacement through a ministernotomy approach. Innovations (Phila). 2018;13(3):239-41. doi:10.1097/IMI.0000000000000479.
    » https://doi.org/10.1097/IMI.0000000000000479
  • 4
    Miceli A, Santarpino G, Pfeiffer S, Murzi M, Gilmanov D, Concistré G, et al. Minimally invasive aortic valve replacement with perceval S sutureless valve: early outcomes and one-year survival from two European centers. J Thorac Cardiovasc Surg. 2014;148(6):2838-43. doi:10.1016/j.jtcvs.2014.02.085.
    » https://doi.org/10.1016/j.jtcvs.2014.02.085

Publication Dates

  • Publication in this collection
    22 July 2019
  • Date of issue
    May-Jun 2019

History

  • Received
    27 May 2018
  • Accepted
    21 July 2018
Sociedade Brasileira de Cirurgia Cardiovascular Rua Afonso Celso, 1178 Vila Mariana, CEP: 04119-061 - São Paulo/SP Brazil, Tel +55 (11) 3849-0341, Tel +55 (11) 5096-0079 - São Paulo - SP - Brazil