Acessibilidade / Reportar erro

Experimental evaluation of the use of starch and carboxymethylcellulose in the prevention of intraperitoneal adhesions in hernia surgery with coated meshes

ABSTRACT

Purpose:

Laparoscopic hernia repair involves a risk of adhesion between coated mesh and viscera. Plant polysaccharides such as starch and carboxymethylcellulose (SC) make up a product that acts as a barrier and prevents intraperitoneal adhesions. This study aimed to evaluate whether topical SC can also reduce adhesions between mesh and intra-abdominal organs.

Methods:

Forty rats each received placement of two intraperitoneal mesh fragments, one on each side of the abdominal wall. Randomly, 20 animals received SC on the right and other 20 on the left, leaving the contralateral side as a control. Fourteen days after the surgery, the animals underwent an additional laparotomy in which macroscopic analysis was performed.

Results:

As for the percentage of the mesh area affected by adhesion, one (2.6%) animal had > 75% adhesion on the experimental side, and 11 animals (28.9%) on the control side. The adhesion intensity score showed firm adhesions in three (7.9%) animals on the experimental side and nine (23.7%) on the control side.

Conclusions:

The use of SC decreased the intensity of adhesions and the surface area of the mesh affected by adhesions. There was no negative interference of the product in the incorporation of the mesh into the abdominal wall.

Key words
Tissue Adhesions; Surgical Mesh; Hernia; Implants, Experimental

Introduction

The exact global incidence of incisional hernias is uncertain, with 2–20% of all laparotomies developing incisional hernias, especially midline laparotomies11 Dietz UA, Menzel S, Lock J, Wiegering A. The treatment of incisional hernia. Dtsch Arztebl Int. 2018;115(3):31–7. https://doi.org/10.3238/arztebl.2018.0031
https://doi.org/10.3238/arztebl.2018.003...
,22 Poruk KE, Farrow N, Azar F, Burce KK, Hicks CW, Azoury SC, Cornell P, Cooney CM, Eckhauser FE. Effect of hernia size on operative repair and post-operative outcomes after open ventral hernia repair. Hernia. 2016;20(6):805–10. https://doi.org/10.1007/s10029-016-1542-2
https://doi.org/10.1007/s10029-016-1542-...
. The recurrence of these hernias in cases of complex repair ranges between 20–30%, with a 30% recurrence after a second repair in cases of a new recurrence33 Bueno-Lledó J, Bonafe-Diana S, Carbonell-Tatay F, Torregrosa-Gallud A, Pous-Serrano S. Component separation and large incisional hernia: predictive factors of recurrence. Hernia. 2021;25(6):1593–600. https://doi.org/10.1007/s10029-021-02489-3
https://doi.org/10.1007/s10029-021-02489...
. These numbers are increasing due to the increasing number of patients undergoing laparotomies and major surgeries, older patients with connective tissue problems, and patients operated on with risk factors for hernia formation, such as obesity and diabetes44 Bittner R, Bain K, Bansal VK, Berrevoet F, Bingener-Casey J, Chen D, Chen J, Chowbey P, Dietz UA, de Beaux A, Ferzli G, Fortelny R, Hoffmann H, Iskander M, Ji Z, Jorgensen LN, Khullar R, Kirchhoff P, Köckerling F, Kukleta J, LeBlanc K, Li J, Lomanto D, Mayer F, Meytes V, Misra M, Morales-Conde S, Niebuhr H, Radvinsky D, Ramshaw B, Ranev D, Reinpold W, Sharma A, Schrittwieser R, Stechemesser B, Sutedja B, Tang J, Warren J, Weyhe D, Wiegering A, Woeste G, Yao Q. Update of Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society (IEHS))-Part A. Surg Endosc. 2019;33(10):3069–139. https://doi.org/10.1007/s00464-019-06907-7
https://doi.org/10.1007/s00464-019-06907...
,55 Faylona JM. Evolution of ventral hernia repair. Asian J Endosc Surg. 2017;10(3):252–8. https://doi.org/10.1111/ases.12392
https://doi.org/10.1111/ases.12392...
.

Laparoscopic surgeries are associated with a lower rate of early complications, such as surgical site infection, seroma, and bleeding66 Köckerling F, Simon T, Adolf D, Köckerling D, Mayer F, Reinpold W, Weyhe D, Bittner R. Laparoscopic IPOM versus open sublay technique for elective incisional hernia repair: a registry-based, propensity score-matched comparison of 9907 patients. Surg Endosc. 2019;33(10):3361–9. https://doi.org/10.1007/s00464-018-06629-2
https://doi.org/10.1007/s00464-018-06629...
, with a shorter duration of hospital stay and fewer hernia recurrences77 Henriksen NA, Friis-Andersen H, Jorgensen LN, Helgstrand F. Open versus laparoscopic incisional hernia repair: nationwide database study. BJS Open. 2021;5(1):zraa010. https://doi.org/10.1093/bjsopen/zraa010
https://doi.org/10.1093/bjsopen/zraa010...
. Also, other inherent advantages are reduced postoperative pain, earlier recovery, and favorable aesthetic effects88 Asencio F, Carbó J, Ferri R, Peiró S, Aguiló J, Torrijo I, Barber S, Canovas R, Andreu-Ballester JC. Laparoscopic versus open incisional hernia repair: long-term follow-up results of a randomized clinical trial. World J Surg. 2021;45(9):2734–41. https://doi.org/10.1007/s00268-021-06164-7
https://doi.org/10.1007/s00268-021-06164...
,99 Domen A, Stabel C, Jawad R, Duchateau N, Fransen E, Vanclooster P, de Gheldere C. Postoperative ileus after laparoscopic primary and incisional abdominal hernia repair with intraperitoneal mesh (DynaMesh®-IPOM versus Parietex™ Composite): a single institution experience. Langenbecks Arch Surg. 2021;406(1):209–18. https://doi.org/10.1007/s00423-020-01898-9
https://doi.org/10.1007/s00423-020-01898...
.

Despite these advantages, laparoscopic repairs using the intraperitoneal onlay mesh (IPOM) technique expose the patient to the risks of mesh in direct contact with intra-abdominal organs and structures. Even when using meshes which supposedly provide a protective barrier, there are reports of complications secondary to ileus, adhesions, mesh infections, abscesses, fibrosis, chronic pain, and even intestinal obstruction, and enteric fistulas99 Domen A, Stabel C, Jawad R, Duchateau N, Fransen E, Vanclooster P, de Gheldere C. Postoperative ileus after laparoscopic primary and incisional abdominal hernia repair with intraperitoneal mesh (DynaMesh®-IPOM versus Parietex™ Composite): a single institution experience. Langenbecks Arch Surg. 2021;406(1):209–18. https://doi.org/10.1007/s00423-020-01898-9
https://doi.org/10.1007/s00423-020-01898...

10 Santos Filho PVD, Santos RS, Leão SC, Duarte IX, Lima SO. Experimental evaluation of intraabdominal adhesions comparing two different intraperitoneal meshes and the effect of a natural anti-inflammatory product on their formation. Acta Cir Bras. 2021;35(12):e351205. https://doi.org/10.1590/ACB351205
https://doi.org/10.1590/ACB351205...

11 Jenkins ED, Yom V, Melman L, Brunt LM, Eagon JC, Frisella MM, Matthews BD. Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair. Surg Endosc. 2010;24(12):3002–7. https://doi.org/10.1007/s00464-010-1076-0
https://doi.org/10.1007/s00464-010-1076-...

12 Zinther NB, Wara P, Friis-Andersen H. Functional cine MRI and transabdominal ultrasonography for the assessment of adhesions to implanted synthetic mesh 5-7 years after laparoscopic ventral hernia repair. Hernia. 2010;14(5):499–504. https://doi.org/10.1007/s10029-010-0676-x
https://doi.org/10.1007/s10029-010-0676-...
-1313 Vuilleumier HA. Adverse effects of intraperitoneal onlay mesh used for incisional hernia repair. Master’s Thesis, Université de Lausanne; 2011. . In addition, possible long-term complications of this technique have not been fully elucidated1414 Soare AM, Cârţu D, Nechita SL, Andronic O, Șurlin V. Complications of Intraperitoneal Mesh Techniques for Incisional Hernia - A Systematic Review. Chirurgia (Bucur). 2021;116(6 Suppl.):S36-S42. .

Adhesions that increase these potential risks occur due to foreign body reaction secondary to the inflammatory reaction generated by the presence of a prosthesis inside the abdominal cavity and in contact with intracavitary organs1010 Santos Filho PVD, Santos RS, Leão SC, Duarte IX, Lima SO. Experimental evaluation of intraabdominal adhesions comparing two different intraperitoneal meshes and the effect of a natural anti-inflammatory product on their formation. Acta Cir Bras. 2021;35(12):e351205. https://doi.org/10.1590/ACB351205
https://doi.org/10.1590/ACB351205...
,1111 Jenkins ED, Yom V, Melman L, Brunt LM, Eagon JC, Frisella MM, Matthews BD. Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair. Surg Endosc. 2010;24(12):3002–7. https://doi.org/10.1007/s00464-010-1076-0
https://doi.org/10.1007/s00464-010-1076-...
,1515 Yang GPC. From intraperitoneal onlay mesh repair to preperitoneal onlay mesh repair. Asian J Endosc Surg. 2017;10(2):119–27. https://doi.org/10.1111/ases.12388
https://doi.org/10.1111/ases.12388...
,1616 Delibegovic S, Koluh A, Cickusic E, Katica M, Mustedanagic J, Krupic F. Formation of adhesion after intraperitoneal application of TiMesh: experimental study on a rodent model. Acta Chir Belg. 2016;116(5):293-300. https://doi.org/10.1080/00015458.2016.1179513
https://doi.org/10.1080/00015458.2016.11...
. Some products available on the market can reduce adhesion formation whether between organs or intraperitoneal structures1717 Metwally M, Cheong Y, Li TC. A review of techniques for adhesion prevention after gynaecological surgery. Curr Opin Obstet Gynecol. 2008;20(4):345–52. https://doi.org/10.1097/GCO.0b013e3283073a6c
https://doi.org/10.1097/GCO.0b013e328307...

18 Poehnert D, Grethe L, Maegel L, Jonigk D, Lippmann T, Kaltenborn A, Schrem H, Klempnauer J, Winny M. Evaluation of the Effectiveness of Peritoneal Adhesion Prevention Devices in a Rat Model. Int J Med Sci. 2016;13(7):524–32. https://doi.org/10.7150/ijms.15167
https://doi.org/10.7150/ijms.15167...

19 Korell M, Ziegler N, De Wilde RL. Use of modified polysaccharide 4DryField (®) PH for adhesion prevention and hemostasis in gynecological surgery: a two-center observational study by second-look laparoscopy. Biomed Res Int. 2016;2016:3029264. https://doi.org/10.1155/2016/3029264
https://doi.org/10.1155/2016/3029264...

20 Blumhardt G, Haas M, Polte S. Effect of 4DryField ® PH, a novel adhesion barrier, on recurrence of intestinal adhesions after extensive visceral adhesiolysis. Case Rep Surg. 2018;2018:9628742. https://doi.org/10.1155/2018/9628742
https://doi.org/10.1155/2018/9628742...
-2121 Park J, Kang H, Choi YS, Suh SW, Hong SA, Choi GJ, Sim WJ. Prevention of intra-abdominal adhesions using the combination of Mediclore® and a statin. Eur Surg Res. 2022;63(3):123–31. https://doi.org/10.1159/000519708
https://doi.org/10.1159/000519708...
or between the mesh and intra-abdominal structures2222 Bouliaris K, Asprodini E, Liakos P, Diamantis A, Koukoulis G, Befani C, Tzika S, Tepetes K. Adhesion Prevention to Polypropylene Meshes Using Combined Icodextrin Four Percent and Dimetindene Maleate. J Surg Res. 2019;234:325–33. https://doi.org/10.1016/j.jss.2018.10.003
https://doi.org/10.1016/j.jss.2018.10.00...
,2323 Winny M, Maegel L, Grethe LV, Jonigk D, Borchert P, Kaltenborn A, Schrem H, Klempnauer J, Poehnert D. Treatment of de-peritonealized intestine with 4DryField ® PH prevents adhesions between non-resorbable intra-peritoneal hernia mesh and bowel. Am J Transl Res. 2016;8(12):5706–14.
https://doi.org/10.1097/AJTRR.0000000000...
. In this context, plant polysaccharides such as starch and carboxymethylcellulose (SC) make up a product that acts as a hemostatic and mechanical barrier and prevents intraperitoneal adhesions2424 Carvalho MV, Marchi E, Pantoroto M, Rossini M, da Silva DM, Teodoro LF, Pantaroto A. Agentes hemostáticos locais e adesivos teciduais [Topical haemostatic agents and tissue adhesives]. Rev Col Bras Cir. 2013;40(1):66-71. https://doi.org/10.1590/s0100-69912013000100012
https://doi.org/10.1590/s0100-6991201300...
,2525 Bae JS, Jin HK, Jang KH. The effect of polysaccharides and carboxymethylcellulose combination to prevent intraperitoneal adhesion and abscess formation in a rat peritonitis model. J Vet Med Sci. 2004;66(10):1205–11. https://doi.org/10.1292/jvms.66.1205
https://doi.org/10.1292/jvms.66.1205...
.

The objective of this study was to evaluate whether topical SC can reduce adhesions between the mesh and intra-abdominal organs after IPOM hernia repair in an experimental model, in addition to the already known effect of preventing intraperitoneal adhesions.

Methods

Ethical approval

This research project complied with the rules of the National Council for Animal Experimentation and was approved by the Animal Ethics Committee of Universidade Tiradentes (no. 011120).

Intraperitoneal mesh

The Symbotex mesh is a synthetic, nonabsorbable mesh made of three-dimensional polyester monofilaments coated with bioabsorbable collagen film on its visceral side. Polyester is the result of the reaction of alcohol with carboxylic acid and is a strong, durable, and hydrophilic material. It has pores of 2.3 – 3.3 mm and 66 g/m22 Poruk KE, Farrow N, Azar F, Burce KK, Hicks CW, Azoury SC, Cornell P, Cooney CM, Eckhauser FE. Effect of hernia size on operative repair and post-operative outcomes after open ventral hernia repair. Hernia. 2016;20(6):805–10. https://doi.org/10.1007/s10029-016-1542-2
https://doi.org/10.1007/s10029-016-1542-...
and has multiple filaments1010 Santos Filho PVD, Santos RS, Leão SC, Duarte IX, Lima SO. Experimental evaluation of intraabdominal adhesions comparing two different intraperitoneal meshes and the effect of a natural anti-inflammatory product on their formation. Acta Cir Bras. 2021;35(12):e351205. https://doi.org/10.1590/ACB351205
https://doi.org/10.1590/ACB351205...
. The mesh was donated by the company.

Anti-adhesion product

Adhesion STP (ASTP) is a natural product made by the plant polysaccharides SC, which have hemostatic and anti-adhesion properties. Carboxymethylcellulose is a low-molecular-weight and water-soluble cellulose product. It reduces adhesion and fibrosis formation by creating a film that works as a mechanical barrier, acting as a healing reorganization agent2626 Astur DC, Baras FC, Chaim RM, Krob JJ, Arliani GG, De Oliveira GT. The efficacy of bicomponent carboxymethylcellulose-polysaccharide B as a hemostatic and anti-adherent agent at the tibial insertion of the hamstring tendons after reconstruction of the anterior cruciate ligament. Muscles Ligaments Tendons J. 2019;9(1):8–13. https://doi.org/10.32098/mltj.01.2019.02
https://doi.org/10.32098/mltj.01.2019.02...
. Starch is derived from plants and acts by dehydrating the blood. It also has a hemostatic action when associated with carboxymethylcellulose2727 Carvalho MVH de, Marchi E. Mechanism of action of topical hemostatic and adhesive tissue agents. Rev Médica Minas Gerais. 2013;23(4):488–93. https://doi.org/10.5935/2238-3182.20130077
https://doi.org/10.5935/2238-3182.201300...
. In addition, this combination stimulates the production of tissue plasminogen activator by macrophages, which results in the conversion of plasminogen into plasmin, with consequent fibrinolytic action and decreased fibrin and adhesion formation2525 Bae JS, Jin HK, Jang KH. The effect of polysaccharides and carboxymethylcellulose combination to prevent intraperitoneal adhesion and abscess formation in a rat peritonitis model. J Vet Med Sci. 2004;66(10):1205–11. https://doi.org/10.1292/jvms.66.1205
https://doi.org/10.1292/jvms.66.1205...
. Carboxymethylcellulose is quickly metabolized by human enzymes, and starch acts for approximately 40 days, generating a low risk of granulomatous reaction due to the short absorption period2626 Astur DC, Baras FC, Chaim RM, Krob JJ, Arliani GG, De Oliveira GT. The efficacy of bicomponent carboxymethylcellulose-polysaccharide B as a hemostatic and anti-adherent agent at the tibial insertion of the hamstring tendons after reconstruction of the anterior cruciate ligament. Muscles Ligaments Tendons J. 2019;9(1):8–13. https://doi.org/10.32098/mltj.01.2019.02
https://doi.org/10.32098/mltj.01.2019.02...
,2828 Poehnert D, Abbas M, Maegel L, Sambale F, Lavrentieva A, Kreipe HH, Klempnauer J, Winny M. Evaluation of the biological tolerability of the starch-based medical device 4DryField® PH in vitro and in vivo a rat model. J Biomater Appl. 2015;30(4):463–71. https://doi.org/10.1177/0885328215592257
https://doi.org/10.1177/0885328215592257...
.

Experimental design

A total of 40 Wistar male rats weighing between 250 and 350 g were used. The animals were housed in the bioterium, with a natural light-dark cycle, adjusted environmental temperature and humidity, and fed and watered ad libitum, both before and after surgery.

The animals underwent laparotomy with placement of two intraperitoneal mesh fragments, one on each side of the abdominal wall. Randomly, 20 animals received SC in the abdominal cavity on the right, and other 20 animals received SC on the left, leaving the contralateral side as a control (with mesh and without SC). The experiment used two 3-g bottles of the product, totaling 6 g, equally divided among the 40 animals analyzed using a precision scale.

Fourteen days after the surgery, the animals underwent an additional laparotomy, in which macroscopic analysis was performed.

Surgical procedure

The animals were anaesthetized with an intraperitoneal injection of 50 mg/kg ketamine hydrochloride and 20 mg/kg xylazine hydrochloride.

After shaving and antisepsis, an 8-cm long incision was made in the ventral part of the abdomen, involving the skin, aponeurosis, and peritoneum, reaching the abdominal cavity. Thereafter, two fragments of meshes measuring 1.5 × 1,5 cm were interposed and fixed to the abdominal wall 1 cm from the midline, with four simple stiches using 4-0 polypropylene (Fig. 1). Randomly, one side of the abdominal cavity received the topical administration of 0.15 g of SC (Fig. 2). Finally, the abdominal wall was sutured using a 3-0 nylon thread with continuous sutures.

Figure 1
Coated mesh fragment fixed to the abdominal wall.
Figure 2
Mesh plus starch and carboxymethylcellulose in the abdominal cavity on the right side.

After complete post-anesthesia recovery, the animals were placed in appropriate cages, with a maximum of three animals per cage, being offered water and food ad libitum until the next surgical procedure.

Euthanasia of the animals and macroscopic post-mortem examination

On the 14th postoperative day (POD), the animals were euthanized using a CO2 chamber. Then, necroscopy was performed, and the macroscopic aspects related to the mesh were observed. The degree of adhesions between the organs and meshes (adhesion scoring), area of adhesion between the surface of the mesh and intraperitoneal structures (adhesion coverage on the mesh surface), and integration of the mesh into the abdominal wall (tissue integration score) were evaluated1010 Santos Filho PVD, Santos RS, Leão SC, Duarte IX, Lima SO. Experimental evaluation of intraabdominal adhesions comparing two different intraperitoneal meshes and the effect of a natural anti-inflammatory product on their formation. Acta Cir Bras. 2021;35(12):e351205. https://doi.org/10.1590/ACB351205
https://doi.org/10.1590/ACB351205...
,2929 Jayanth ST, Pulimood A, Abraham D, Rajaram A, Paul MJ, Nair A. A randomized controlled experimental study comparing chitosan coated polypropylene mesh and ProceedTM mesh for abdominal wall defect closure. Ann Med Surg. 2015;4(4):388–94. https://doi.org/10.1016/j.amsu.2015.10.002
https://doi.org/10.1016/j.amsu.2015.10.0...
,3030 Gruber-Blum S, Petter-Puchner AH, Brand J, Fortelny RH, Walder N, Oehlinger W, Koenig F, Redl H. Comparison of three separate antiadhesive barriers for intraperitoneal onlay mesh hernia repair in an experimental model. Br J Surg. 2011;98(3):442–9. https://doi.org/10.1002/bjs.7334
https://doi.org/10.1002/bjs.7334...
(Tables 13).

Table 1
Adhesion scoring.
Table 2
Assessment of area of adhesion coverage on the mesh surface.
Table 3
Tissue integration score.

Statistical analysis

The variables were described as absolute and relative percentage frequencies. The hypothesis of equal location measures was tested using the Mann-Whitney’s test. The rank-biserial correlation effect size was estimated to evaluate the size of the observed differences, which evaluates the percentage of evidence favorable to a given hypothesis. The study considered a 5% significance level and used the R Core Team 2022 software (Version 4.2.0).

Results

One animal died on the nineth POD and another on the 12th POD due to undetermined causes. The mesh used with and without topical SC was evaluated regarding the percentage of surface affected by adhesions, the degree of intensity of the adhesions formed, and the degree of incorporation of the mesh into the abdominal wall on the 14th POD (Table 4).

Table 4
Results of adhesions and integration on 14th postoperative day.

In all cases, the results showed some degree of adhesion with or without SC, even with coated meshes.

As for the percentage of the mesh area affected by adhesion, two (5.3%) animals with mesh and SC and one (2.6%) only with mesh had 0% of their surface affected, as they had adhesions only on the mesh edges; 27 (71.1%) animals on the experimental side and 16 (42.1%) on the control side had between 1–25% of their surface affected; four (10.5%) animals on the experimental side and three (7.9%) on the control side had between 25–50% of their surface affected (Fig. 3); four (10.5%) animals on the experimental side and seven (18.4%) on the control side had between 50–75% of their surface affected; and one (2.6%) animal had > 75% adhesion on the experimental side and 11 animals (28.9%) on the control side. The results for the % of mesh surface affected by adhesions (p = 0.001) were significant, with evidence of a higher % adhesion surface on the control side (R = -0.384).

Figure 3
Adhesions between bowel and mesh (25–50% of their surface affected).

Another variable analyzed was the adhesion intensity score, which showed that 29 (76.3%) animals had flimsy adhesions between the mesh and the intra-abdominal structures on the experimental side, and 21 (55.3%) on the control side. Intermediate adhesions were present in six (15.8%) animals on the experimental side and eight (21.1%) on the control side. Firm adhesions were present in three (7.9%) animals on the experimental side and nine (23.7%) on the control side. The intensity of adhesions formed also showed significant results (p = 0.039), with evidence of firmer adhesions in the control group (R = 0.231).

SC presented no significant results regarding the integration between the mesh and the abdominal wall (p = 0.579), with 36 (94.7%) animals on the experimental side and 37 (97.4%) on the control side being classified as A; two experimental animals (5.3%) and no control classified as B; and only one (2.6%) control animal classified as C (Fig. 4).

Figure 4
Mesh with less than 50 per cent of mesh surface integrated.

Discussion

As mesh adhesions are one of the main complications and cause of concern when using the IPOM technique, surgeons seek ways to reduce or stop these adhesions. Some surgical techniques avoid the use of intraperitoneal meshes and access retromuscular or preperitoneal spaces3131 Belyansky I, Reza Zahiri H, Sanford Z, Weltz AS, Park A. Early operative outcomes of endoscopic (eTEP access) robotic-assisted retromuscular abdominal wall hernia repair. Hernia. 2018;22(5):837–47. https://doi.org/10.1007/s10029-018-1795-z
https://doi.org/10.1007/s10029-018-1795-...

32 Grossi JVM, Lee B, Belyansky I, Carbonell AM, Cavazzola LT, Novitsky YW, Ballecer CD. Critical view of robotic-assisted transverse abdominal release (r-TAR). Hernia. 2021;25(6):1715–25. https://doi.org/10.1007/s10029-021-02391-y
https://doi.org/10.1007/s10029-021-02391...

33 Bracale U, Corcione F, Neola D, Castiglioni S, Cavallaro G, Stabilini C, Botteri E, Sodo M, Imperatore N, Peltrini R. Transversus abdominis release (TAR) for ventral hernia repair: open or robotic? Short-term outcomes from a systematic review with meta-analysis. Hernia. 2021;25(6):1471–80. https://doi.org/10.1007/s10029-021-02487-5
https://doi.org/10.1007/s10029-021-02487...
-3434 Megas IF, Benzing C, Winter A, Raakow J, Chopra S, Pratschke J. A propensity-score matched analysis of ventral-TAPP vs. laparoscopic IPOM for small and mid-sized ventral hernias. Comparison of perioperative data, surgical outcome and cost-effectiveness. Hernia. 2022;26(6):1521–30. https://doi.org/10.1007/s10029-022-02586-x
https://doi.org/10.1007/s10029-022-02586...
. However, these options are not always possible, and IPOM is necessary, especially in urgent surgeries with older and/or obese patients. In addition, these new techniques are more complex, requiring specific training and sometimes the use of robotic platforms3535 Van Hoef S, Tollens T. Primary non-complicated midline ventral hernia: is laparoscopic IPOM still a reasonable approach? Hernia. 2019;23(5):915–25. https://doi.org/10.1007/s10029-019-02031-6
https://doi.org/10.1007/s10029-019-02031...
. Another way to prevent these adhesions is to use topical agents that act as an additional protective barrier that separates the mesh from adjacent intra-abdominal structures during the healing process in the critical period of adhesion formation2828 Poehnert D, Abbas M, Maegel L, Sambale F, Lavrentieva A, Kreipe HH, Klempnauer J, Winny M. Evaluation of the biological tolerability of the starch-based medical device 4DryField® PH in vitro and in vivo a rat model. J Biomater Appl. 2015;30(4):463–71. https://doi.org/10.1177/0885328215592257
https://doi.org/10.1177/0885328215592257...
.

In the present study, despite using a coated mesh, all animals showed some degree of adhesion. As for the percentage of the mesh area affected by adhesion, two animals (5.2%) on the experimental side and one (2.6%) on the control had 0% of the surface affected, as they had adhesions only on the mesh edges. The other animals showed adhesions on the mesh surface with or without SC. Some experimental and even clinical studies demonstrated that, even with the protective barrier, these intraperitoneal meshes present different degrees of adhesions with intra-abdominal structures99 Domen A, Stabel C, Jawad R, Duchateau N, Fransen E, Vanclooster P, de Gheldere C. Postoperative ileus after laparoscopic primary and incisional abdominal hernia repair with intraperitoneal mesh (DynaMesh®-IPOM versus Parietex™ Composite): a single institution experience. Langenbecks Arch Surg. 2021;406(1):209–18. https://doi.org/10.1007/s00423-020-01898-9
https://doi.org/10.1007/s00423-020-01898...

10 Santos Filho PVD, Santos RS, Leão SC, Duarte IX, Lima SO. Experimental evaluation of intraabdominal adhesions comparing two different intraperitoneal meshes and the effect of a natural anti-inflammatory product on their formation. Acta Cir Bras. 2021;35(12):e351205. https://doi.org/10.1590/ACB351205
https://doi.org/10.1590/ACB351205...

11 Jenkins ED, Yom V, Melman L, Brunt LM, Eagon JC, Frisella MM, Matthews BD. Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair. Surg Endosc. 2010;24(12):3002–7. https://doi.org/10.1007/s00464-010-1076-0
https://doi.org/10.1007/s00464-010-1076-...

12 Zinther NB, Wara P, Friis-Andersen H. Functional cine MRI and transabdominal ultrasonography for the assessment of adhesions to implanted synthetic mesh 5-7 years after laparoscopic ventral hernia repair. Hernia. 2010;14(5):499–504. https://doi.org/10.1007/s10029-010-0676-x
https://doi.org/10.1007/s10029-010-0676-...
-1313 Vuilleumier HA. Adverse effects of intraperitoneal onlay mesh used for incisional hernia repair. Master’s Thesis, Université de Lausanne; 2011. ,3636 Sommer T, Friis-Andersen H. DynaMesh® in the repair of laparoscopic ventral hernia: a prospective trial. Hernia. 2013;17(5):613–8. https://doi.org/10.1007/s10029-013-1090-y
https://doi.org/10.1007/s10029-013-1090-...
. For this reason, ways to mitigate this complication and its clinical repercussions are being studied. In the present study, the SC protective barrier did not reduce the incidence of adhesions, but other aspects evaluated, such as adhesion intensity and surface area, were decreased after its use.

The meshes coated with a protective barrier have different materials on their visceral surface that allow contact between the mesh and intra-abdominal organs. These materials include polyvinylidene fluoride, polylactic acid, oxygenated regenerated cellulose, polyglycolic acid, collagen, and chitosan3737 Baylón K, Rodríguez-Camarillo P, Elías-Zúñiga A, Díaz-Elizondo JA, Gilkerson R, Lozano K. Past, present and future of surgical meshes: a review. Membranes (Basel). 2017;7(3):47. https://doi.org/10.3390/membranes7030047
https://doi.org/10.3390/membranes7030047...
,3838 Jamry A, Jałyński M, Piskorz L, Brocki M. Assessment of adhesion formation after laparoscopic intraperitoneal implantation of Dynamesh IPOM mesh. Arch Med Sci. 2013;9(3):487–92. https://doi.org/10.5114/aoms.2013.35345
https://doi.org/10.5114/aoms.2013.35345...
. The Symbotex mesh used in the experiment has collagen as a protective material. The use of a second protection mechanism, as in the experiment, added to the one already present on the mesh, may have synergistically acted and offered extra protection that resulted in lower intensity and smaller area of adhesion. The SC barrier protects the intra-abdominal organs from mechanical injuries caused by contact with the mesh, thus decreasing adhesion formation, since less contact and trauma decrease tissue damage and increase vascular permeability with fibrinogen release and fibrin formation3939 Brüggmann D, Tchartchian G, Wallwiener M, Münstedt K, Tinneberg HR, Hackethal A. Intraabdominale adhäsionen - Definition, entstehung, bedeutung in der operativen medizin und möglichkeiten der reduktion. Dtsch Arztebl. 2010;107(44):769–75. https://doi.org/10.3238/arztebl.2010.0769
https://doi.org/10.3238/arztebl.2010.076...
. Other meshes with different protective materials associated with the topical use of SC can be tested in future studies to clarify whether this probable added protection effect also occurs with other materials.

The product used in the experiment is available in the Brazilian market under the commercial name Adhesion STP. It is marketed in the form of powder or gel, with packages of 1, 3, or 5 g and with the possibility of laparoscopic application. This study used the powder presentation as it can be applied to a larger area and it is easier to use. Another brand like the one used in the study is the 4DryField (4DF), which contains only starch and no carboxymethylcellulose and it is not available in Brazil, but it is used in Europe. This product is also available as powder and in 1-, 3-, 5-, and 9-g packages. Arista is another product containing the plant polysaccharide starch and it is also available as powder and in presentations of 1, 3, and 5 g.

This experiment used a total of 6 g of SC (two 3-g bottles), divided equally among 40 rats, totaling 0.15 g of the product in each animal, with the contralateral side of the studied abdomen being the control. Such volume was determined based on the total coverage of half of the abdominal cavity of each animal, with SC being sufficient to cover the contact area between the mesh and the intracavitary organs, respecting the proposed dose of up to 1 g/kg2828 Poehnert D, Abbas M, Maegel L, Sambale F, Lavrentieva A, Kreipe HH, Klempnauer J, Winny M. Evaluation of the biological tolerability of the starch-based medical device 4DryField® PH in vitro and in vivo a rat model. J Biomater Appl. 2015;30(4):463–71. https://doi.org/10.1177/0885328215592257
https://doi.org/10.1177/0885328215592257...
. It is not clear whether the use of larger volumes can further reduce the adhesion intensity and area. Therefore, further studies evaluating this aspect are necessary. Larger volumes than those available in current presentations may be necessary for the protective effect to occur in clinical practice, especially when larger meshes are used, respecting its tolerability.

There are no studies in the literature evaluating the systemic effects of SC in the form of ASTP. There is also no mention of side effects in its instructions for use. 4DF, in turn, brings a package insert warning regarding the possibility of an inflammatory reaction with increased C-reactive protein after its use. However, a retrospective study evaluated systemic inflammatory effects, and this product was considered safe as it did not induce a significant systemic inflammatory response in patients using between 3–5 g of 4DF4040 Ziegler N, Torres-de la Roche LA, Devassy R, De Wilde RL. Changed inflammatory markers after application of 4DryField PH for adhesion prevention in gynecological surgery. Arch Gynecol Obstet. 2021;304(4):951–5. https://doi.org/10.1007/s00404-021-06095-7
https://doi.org/10.1007/s00404-021-06095...
. Another experimental study also evaluated the tolerability of this same presentation and concluded that the product had excellent biocompatibility with in-vitro analysis, showing no cytotoxicity or tumor cell growth. This analysis demonstrated that a dose of up to 1.09 g/kg is well tolerated and degraded after a few days2828 Poehnert D, Abbas M, Maegel L, Sambale F, Lavrentieva A, Kreipe HH, Klempnauer J, Winny M. Evaluation of the biological tolerability of the starch-based medical device 4DryField® PH in vitro and in vivo a rat model. J Biomater Appl. 2015;30(4):463–71. https://doi.org/10.1177/0885328215592257
https://doi.org/10.1177/0885328215592257...
. Experimental foreign body reaction was also considered minimal4141 Byun Y, Kim EJ, Lee A, Suh YA, Sohn HJ, Lee JM, Kang JS, Choi YJ, Han Y, Kim H, Kwon W, Jang JY. In vivo study for the hemostatic efficacy and foreign body reaction of a new powder-type polysaccharide hemostatic agent. Ann Surg Treat Res. 2022;102(2):65–72. https://doi.org/10.4174/astr.2022.102.2.65
https://doi.org/10.4174/astr.2022.102.2....
. Although these are plant-derived products with good biocompatibility and low risk of triggering allergic reactions, future experimental studies are also needed to assess the systemic effects and tolerability of SC in the form of ASTP.

Plant polysaccharides have been used to avoid intra-abdominal adhesions after conventional surgery. On an experimental basis, compared to other non-adherent agents, it significantly reduced the incidence and severity of adhesions after laparotomies4242 Poehnert D, Grethe L, Maegel L, Jonigk D, Lippmann T, Kaltenborn A, Schrem H, Klempnauer J, Winny M. Evaluation of the effectiveness of peritoneal adhesion prevention devices in a rat model. Int J Med Sci. 2016;13(7):524–32. https://doi.org/10.7150/ijms.15167
https://doi.org/10.7150/ijms.15167...
. It has also been studied in case series, with evidence of decreased new adhesion formation with topical use in a two-year follow-up2020 Blumhardt G, Haas M, Polte S. Effect of 4DryField ® PH, a novel adhesion barrier, on recurrence of intestinal adhesions after extensive visceral adhesiolysis. Case Rep Surg. 2018;2018:9628742. https://doi.org/10.1155/2018/9628742
https://doi.org/10.1155/2018/9628742...
.

Another clinical study evaluated 20 women undergoing re-laparotomies after using 4DF, showing that 18 of them had effective adhesion prevention with topical use of 3–15 g of the product1919 Korell M, Ziegler N, De Wilde RL. Use of modified polysaccharide 4DryField (®) PH for adhesion prevention and hemostasis in gynecological surgery: a two-center observational study by second-look laparoscopy. Biomed Res Int. 2016;2016:3029264. https://doi.org/10.1155/2016/3029264
https://doi.org/10.1155/2016/3029264...
. As for its specific ability to prevent or reduce adhesions between intraperitoneal meshes and intra-abdominal structures, only one experimental study using 4DF starch is available in the literature2323 Winny M, Maegel L, Grethe LV, Jonigk D, Borchert P, Kaltenborn A, Schrem H, Klempnauer J, Poehnert D. Treatment of de-peritonealized intestine with 4DryField ® PH prevents adhesions between non-resorbable intra-peritoneal hernia mesh and bowel. Am J Transl Res. 2016;8(12):5706–14.
https://doi.org/10.1097/AJTRR.0000000000...
. That study evaluated 20 rats using the gel and powder presentations, having as a control group study previously published in the literature. Unlike the present study, that study used conventional meshes without a protective barrier. Even so, the product significantly reduced adhesions, especially in powder form. In the present study, we chose to use coated meshes, since they are the meshes used in clinical practice, which have also resulted in adhesion formation. The Arista plant polysaccharide also demonstrated decreased adhesion formation in an experiment with its use as a hemostatic agent4343 Hoffmann NE, Siddiqui SA, Agarwal S, McKellar SH, Kurtz HJ, Gettman MT, Ereth MH. Choice of hemostatic agent influences adhesion formation in a rat cecal adhesion model. J Surg Res. 2009;155(1):77–81. https://doi.org/10.1016/j.jss.2008.08.008
https://doi.org/10.1016/j.jss.2008.08.00...
. Starch has a synergistic effect when associated with carboxymethylcellulose, providing additional capacity to reduce intra-abdominal adhesions and abscess formation, as demonstrated in an experimental study2525 Bae JS, Jin HK, Jang KH. The effect of polysaccharides and carboxymethylcellulose combination to prevent intraperitoneal adhesion and abscess formation in a rat peritonitis model. J Vet Med Sci. 2004;66(10):1205–11. https://doi.org/10.1292/jvms.66.1205
https://doi.org/10.1292/jvms.66.1205...
. No other studies prior to this one used starch associated with carboxymethylcellulose (Adhesion STP) to avoid adherence to coated meshes.

As for the intensity of the adhesions evaluated in the study, there were mesh adhesions with the intestine and liver on the side of the mesh without SC (Fig. 3). A higher percentage of firm adhesions was also observed on the control side compared to the experimental group. In this group, among the nine firm adhesions, three involved the intestine and liver. This finding demonstrates that complications could be significant if this concept is extrapolated to humans.

As for the percentage of the surface area of the mesh affected by adhesions, most of the adhesions on the SC side scored 1–25%, and only one animal had adhesions in > 75% of the mesh. In the sided without SC, the number of animals with adhesions decreased in the score between 1–25% and increased in the score between 5–75% and > 75%, demonstrating protective effect of SC in the area affected by adhesions.

As for incorporation, the purpose of this study was to assess whether the topical use of SC could interfere in this process, but there was no statistically significant difference, i.e., its use did not interfere with the mesh incorporation into the abdominal wall. Only one animal on the side without SC had < 50% incorporation. This is important because the proper incorporation of the mesh into the abdominal wall is crucial for the outcome of hernia surgeries. Thus, the product could not interfere with the biological process of fibrous tissue formation.

Since this is the only study evaluating the effect of ASTP, with another experimental study evaluating the effect of 4DF in preventing intraperitoneal mesh adhesions, different experimental studies with larger samples, different dosages, other meshes, and even comparing the available brands are needed before we can propose the clinical use of this product.

Conclusion

The topical use of the product composed of SC experimentally decreased the intensity of adhesions and the surface area of the mesh affected by adhesions with intra-abdominal structures. There was no negative interference of the product in the incorporation of the mesh into the abdominal wall.

Acknowledgments

Not applicable.

  • Research performed at Postgraduate Program in Surgical Science, Universidade Estadual de Campinas, Campinas (SP), Brazil. Part of Doctorate Degree, Postgraduate Program in Surgical Science. Tutor: Prof. Dr. Elcio Hirano.
  • Funding

    Not applicable.

Data availability statement

The data will be available upon request

References

  • 1
    Dietz UA, Menzel S, Lock J, Wiegering A. The treatment of incisional hernia. Dtsch Arztebl Int. 2018;115(3):31–7. https://doi.org/10.3238/arztebl.2018.0031
    » https://doi.org/10.3238/arztebl.2018.0031
  • 2
    Poruk KE, Farrow N, Azar F, Burce KK, Hicks CW, Azoury SC, Cornell P, Cooney CM, Eckhauser FE. Effect of hernia size on operative repair and post-operative outcomes after open ventral hernia repair. Hernia. 2016;20(6):805–10. https://doi.org/10.1007/s10029-016-1542-2
    » https://doi.org/10.1007/s10029-016-1542-2
  • 3
    Bueno-Lledó J, Bonafe-Diana S, Carbonell-Tatay F, Torregrosa-Gallud A, Pous-Serrano S. Component separation and large incisional hernia: predictive factors of recurrence. Hernia. 2021;25(6):1593–600. https://doi.org/10.1007/s10029-021-02489-3
    » https://doi.org/10.1007/s10029-021-02489-3
  • 4
    Bittner R, Bain K, Bansal VK, Berrevoet F, Bingener-Casey J, Chen D, Chen J, Chowbey P, Dietz UA, de Beaux A, Ferzli G, Fortelny R, Hoffmann H, Iskander M, Ji Z, Jorgensen LN, Khullar R, Kirchhoff P, Köckerling F, Kukleta J, LeBlanc K, Li J, Lomanto D, Mayer F, Meytes V, Misra M, Morales-Conde S, Niebuhr H, Radvinsky D, Ramshaw B, Ranev D, Reinpold W, Sharma A, Schrittwieser R, Stechemesser B, Sutedja B, Tang J, Warren J, Weyhe D, Wiegering A, Woeste G, Yao Q. Update of Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society (IEHS))-Part A. Surg Endosc. 2019;33(10):3069–139. https://doi.org/10.1007/s00464-019-06907-7
    » https://doi.org/10.1007/s00464-019-06907-7
  • 5
    Faylona JM. Evolution of ventral hernia repair. Asian J Endosc Surg. 2017;10(3):252–8. https://doi.org/10.1111/ases.12392
    » https://doi.org/10.1111/ases.12392
  • 6
    Köckerling F, Simon T, Adolf D, Köckerling D, Mayer F, Reinpold W, Weyhe D, Bittner R. Laparoscopic IPOM versus open sublay technique for elective incisional hernia repair: a registry-based, propensity score-matched comparison of 9907 patients. Surg Endosc. 2019;33(10):3361–9. https://doi.org/10.1007/s00464-018-06629-2
    » https://doi.org/10.1007/s00464-018-06629-2
  • 7
    Henriksen NA, Friis-Andersen H, Jorgensen LN, Helgstrand F. Open versus laparoscopic incisional hernia repair: nationwide database study. BJS Open. 2021;5(1):zraa010. https://doi.org/10.1093/bjsopen/zraa010
    » https://doi.org/10.1093/bjsopen/zraa010
  • 8
    Asencio F, Carbó J, Ferri R, Peiró S, Aguiló J, Torrijo I, Barber S, Canovas R, Andreu-Ballester JC. Laparoscopic versus open incisional hernia repair: long-term follow-up results of a randomized clinical trial. World J Surg. 2021;45(9):2734–41. https://doi.org/10.1007/s00268-021-06164-7
    » https://doi.org/10.1007/s00268-021-06164-7
  • 9
    Domen A, Stabel C, Jawad R, Duchateau N, Fransen E, Vanclooster P, de Gheldere C. Postoperative ileus after laparoscopic primary and incisional abdominal hernia repair with intraperitoneal mesh (DynaMesh®-IPOM versus Parietex™ Composite): a single institution experience. Langenbecks Arch Surg. 2021;406(1):209–18. https://doi.org/10.1007/s00423-020-01898-9
    » https://doi.org/10.1007/s00423-020-01898-9
  • 10
    Santos Filho PVD, Santos RS, Leão SC, Duarte IX, Lima SO. Experimental evaluation of intraabdominal adhesions comparing two different intraperitoneal meshes and the effect of a natural anti-inflammatory product on their formation. Acta Cir Bras. 2021;35(12):e351205. https://doi.org/10.1590/ACB351205
    » https://doi.org/10.1590/ACB351205
  • 11
    Jenkins ED, Yom V, Melman L, Brunt LM, Eagon JC, Frisella MM, Matthews BD. Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair. Surg Endosc. 2010;24(12):3002–7. https://doi.org/10.1007/s00464-010-1076-0
    » https://doi.org/10.1007/s00464-010-1076-0
  • 12
    Zinther NB, Wara P, Friis-Andersen H. Functional cine MRI and transabdominal ultrasonography for the assessment of adhesions to implanted synthetic mesh 5-7 years after laparoscopic ventral hernia repair. Hernia. 2010;14(5):499–504. https://doi.org/10.1007/s10029-010-0676-x
    » https://doi.org/10.1007/s10029-010-0676-x
  • 13
    Vuilleumier HA. Adverse effects of intraperitoneal onlay mesh used for incisional hernia repair. Master’s Thesis, Université de Lausanne; 2011.
  • 14
    Soare AM, Cârţu D, Nechita SL, Andronic O, Șurlin V. Complications of Intraperitoneal Mesh Techniques for Incisional Hernia - A Systematic Review. Chirurgia (Bucur). 2021;116(6 Suppl.):S36-S42.
  • 15
    Yang GPC. From intraperitoneal onlay mesh repair to preperitoneal onlay mesh repair. Asian J Endosc Surg. 2017;10(2):119–27. https://doi.org/10.1111/ases.12388
    » https://doi.org/10.1111/ases.12388
  • 16
    Delibegovic S, Koluh A, Cickusic E, Katica M, Mustedanagic J, Krupic F. Formation of adhesion after intraperitoneal application of TiMesh: experimental study on a rodent model. Acta Chir Belg. 2016;116(5):293-300. https://doi.org/10.1080/00015458.2016.1179513
    » https://doi.org/10.1080/00015458.2016.1179513
  • 17
    Metwally M, Cheong Y, Li TC. A review of techniques for adhesion prevention after gynaecological surgery. Curr Opin Obstet Gynecol. 2008;20(4):345–52. https://doi.org/10.1097/GCO.0b013e3283073a6c
    » https://doi.org/10.1097/GCO.0b013e3283073a6c
  • 18
    Poehnert D, Grethe L, Maegel L, Jonigk D, Lippmann T, Kaltenborn A, Schrem H, Klempnauer J, Winny M. Evaluation of the Effectiveness of Peritoneal Adhesion Prevention Devices in a Rat Model. Int J Med Sci. 2016;13(7):524–32. https://doi.org/10.7150/ijms.15167
    » https://doi.org/10.7150/ijms.15167
  • 19
    Korell M, Ziegler N, De Wilde RL. Use of modified polysaccharide 4DryField (®) PH for adhesion prevention and hemostasis in gynecological surgery: a two-center observational study by second-look laparoscopy. Biomed Res Int. 2016;2016:3029264. https://doi.org/10.1155/2016/3029264
    » https://doi.org/10.1155/2016/3029264
  • 20
    Blumhardt G, Haas M, Polte S. Effect of 4DryField ® PH, a novel adhesion barrier, on recurrence of intestinal adhesions after extensive visceral adhesiolysis. Case Rep Surg. 2018;2018:9628742. https://doi.org/10.1155/2018/9628742
    » https://doi.org/10.1155/2018/9628742
  • 21
    Park J, Kang H, Choi YS, Suh SW, Hong SA, Choi GJ, Sim WJ. Prevention of intra-abdominal adhesions using the combination of Mediclore® and a statin. Eur Surg Res. 2022;63(3):123–31. https://doi.org/10.1159/000519708
    » https://doi.org/10.1159/000519708
  • 22
    Bouliaris K, Asprodini E, Liakos P, Diamantis A, Koukoulis G, Befani C, Tzika S, Tepetes K. Adhesion Prevention to Polypropylene Meshes Using Combined Icodextrin Four Percent and Dimetindene Maleate. J Surg Res. 2019;234:325–33. https://doi.org/10.1016/j.jss.2018.10.003
    » https://doi.org/10.1016/j.jss.2018.10.003
  • 23
    Winny M, Maegel L, Grethe LV, Jonigk D, Borchert P, Kaltenborn A, Schrem H, Klempnauer J, Poehnert D. Treatment of de-peritonealized intestine with 4DryField ® PH prevents adhesions between non-resorbable intra-peritoneal hernia mesh and bowel. Am J Transl Res. 2016;8(12):5706–14.
    » https://doi.org/10.1097/AJTRR.00000000000009
  • 24
    Carvalho MV, Marchi E, Pantoroto M, Rossini M, da Silva DM, Teodoro LF, Pantaroto A. Agentes hemostáticos locais e adesivos teciduais [Topical haemostatic agents and tissue adhesives]. Rev Col Bras Cir. 2013;40(1):66-71. https://doi.org/10.1590/s0100-69912013000100012
    » https://doi.org/10.1590/s0100-69912013000100012
  • 25
    Bae JS, Jin HK, Jang KH. The effect of polysaccharides and carboxymethylcellulose combination to prevent intraperitoneal adhesion and abscess formation in a rat peritonitis model. J Vet Med Sci. 2004;66(10):1205–11. https://doi.org/10.1292/jvms.66.1205
    » https://doi.org/10.1292/jvms.66.1205
  • 26
    Astur DC, Baras FC, Chaim RM, Krob JJ, Arliani GG, De Oliveira GT. The efficacy of bicomponent carboxymethylcellulose-polysaccharide B as a hemostatic and anti-adherent agent at the tibial insertion of the hamstring tendons after reconstruction of the anterior cruciate ligament. Muscles Ligaments Tendons J. 2019;9(1):8–13. https://doi.org/10.32098/mltj.01.2019.02
    » https://doi.org/10.32098/mltj.01.2019.02
  • 27
    Carvalho MVH de, Marchi E. Mechanism of action of topical hemostatic and adhesive tissue agents. Rev Médica Minas Gerais. 2013;23(4):488–93. https://doi.org/10.5935/2238-3182.20130077
    » https://doi.org/10.5935/2238-3182.20130077
  • 28
    Poehnert D, Abbas M, Maegel L, Sambale F, Lavrentieva A, Kreipe HH, Klempnauer J, Winny M. Evaluation of the biological tolerability of the starch-based medical device 4DryField® PH in vitro and in vivo a rat model. J Biomater Appl. 2015;30(4):463–71. https://doi.org/10.1177/0885328215592257
    » https://doi.org/10.1177/0885328215592257
  • 29
    Jayanth ST, Pulimood A, Abraham D, Rajaram A, Paul MJ, Nair A. A randomized controlled experimental study comparing chitosan coated polypropylene mesh and ProceedTM mesh for abdominal wall defect closure. Ann Med Surg. 2015;4(4):388–94. https://doi.org/10.1016/j.amsu.2015.10.002
    » https://doi.org/10.1016/j.amsu.2015.10.002
  • 30
    Gruber-Blum S, Petter-Puchner AH, Brand J, Fortelny RH, Walder N, Oehlinger W, Koenig F, Redl H. Comparison of three separate antiadhesive barriers for intraperitoneal onlay mesh hernia repair in an experimental model. Br J Surg. 2011;98(3):442–9. https://doi.org/10.1002/bjs.7334
    » https://doi.org/10.1002/bjs.7334
  • 31
    Belyansky I, Reza Zahiri H, Sanford Z, Weltz AS, Park A. Early operative outcomes of endoscopic (eTEP access) robotic-assisted retromuscular abdominal wall hernia repair. Hernia. 2018;22(5):837–47. https://doi.org/10.1007/s10029-018-1795-z
    » https://doi.org/10.1007/s10029-018-1795-z
  • 32
    Grossi JVM, Lee B, Belyansky I, Carbonell AM, Cavazzola LT, Novitsky YW, Ballecer CD. Critical view of robotic-assisted transverse abdominal release (r-TAR). Hernia. 2021;25(6):1715–25. https://doi.org/10.1007/s10029-021-02391-y
    » https://doi.org/10.1007/s10029-021-02391-y
  • 33
    Bracale U, Corcione F, Neola D, Castiglioni S, Cavallaro G, Stabilini C, Botteri E, Sodo M, Imperatore N, Peltrini R. Transversus abdominis release (TAR) for ventral hernia repair: open or robotic? Short-term outcomes from a systematic review with meta-analysis. Hernia. 2021;25(6):1471–80. https://doi.org/10.1007/s10029-021-02487-5
    » https://doi.org/10.1007/s10029-021-02487-5
  • 34
    Megas IF, Benzing C, Winter A, Raakow J, Chopra S, Pratschke J. A propensity-score matched analysis of ventral-TAPP vs. laparoscopic IPOM for small and mid-sized ventral hernias. Comparison of perioperative data, surgical outcome and cost-effectiveness. Hernia. 2022;26(6):1521–30. https://doi.org/10.1007/s10029-022-02586-x
    » https://doi.org/10.1007/s10029-022-02586-x
  • 35
    Van Hoef S, Tollens T. Primary non-complicated midline ventral hernia: is laparoscopic IPOM still a reasonable approach? Hernia. 2019;23(5):915–25. https://doi.org/10.1007/s10029-019-02031-6
    » https://doi.org/10.1007/s10029-019-02031-6
  • 36
    Sommer T, Friis-Andersen H. DynaMesh® in the repair of laparoscopic ventral hernia: a prospective trial. Hernia. 2013;17(5):613–8. https://doi.org/10.1007/s10029-013-1090-y
    » https://doi.org/10.1007/s10029-013-1090-y
  • 37
    Baylón K, Rodríguez-Camarillo P, Elías-Zúñiga A, Díaz-Elizondo JA, Gilkerson R, Lozano K. Past, present and future of surgical meshes: a review. Membranes (Basel). 2017;7(3):47. https://doi.org/10.3390/membranes7030047
    » https://doi.org/10.3390/membranes7030047
  • 38
    Jamry A, Jałyński M, Piskorz L, Brocki M. Assessment of adhesion formation after laparoscopic intraperitoneal implantation of Dynamesh IPOM mesh. Arch Med Sci. 2013;9(3):487–92. https://doi.org/10.5114/aoms.2013.35345
    » https://doi.org/10.5114/aoms.2013.35345
  • 39
    Brüggmann D, Tchartchian G, Wallwiener M, Münstedt K, Tinneberg HR, Hackethal A. Intraabdominale adhäsionen - Definition, entstehung, bedeutung in der operativen medizin und möglichkeiten der reduktion. Dtsch Arztebl. 2010;107(44):769–75. https://doi.org/10.3238/arztebl.2010.0769
    » https://doi.org/10.3238/arztebl.2010.0769
  • 40
    Ziegler N, Torres-de la Roche LA, Devassy R, De Wilde RL. Changed inflammatory markers after application of 4DryField PH for adhesion prevention in gynecological surgery. Arch Gynecol Obstet. 2021;304(4):951–5. https://doi.org/10.1007/s00404-021-06095-7
    » https://doi.org/10.1007/s00404-021-06095-7
  • 41
    Byun Y, Kim EJ, Lee A, Suh YA, Sohn HJ, Lee JM, Kang JS, Choi YJ, Han Y, Kim H, Kwon W, Jang JY. In vivo study for the hemostatic efficacy and foreign body reaction of a new powder-type polysaccharide hemostatic agent. Ann Surg Treat Res. 2022;102(2):65–72. https://doi.org/10.4174/astr.2022.102.2.65
    » https://doi.org/10.4174/astr.2022.102.2.65
  • 42
    Poehnert D, Grethe L, Maegel L, Jonigk D, Lippmann T, Kaltenborn A, Schrem H, Klempnauer J, Winny M. Evaluation of the effectiveness of peritoneal adhesion prevention devices in a rat model. Int J Med Sci. 2016;13(7):524–32. https://doi.org/10.7150/ijms.15167
    » https://doi.org/10.7150/ijms.15167
  • 43
    Hoffmann NE, Siddiqui SA, Agarwal S, McKellar SH, Kurtz HJ, Gettman MT, Ereth MH. Choice of hemostatic agent influences adhesion formation in a rat cecal adhesion model. J Surg Res. 2009;155(1):77–81. https://doi.org/10.1016/j.jss.2008.08.008
    » https://doi.org/10.1016/j.jss.2008.08.008

Publication Dates

  • Publication in this collection
    18 Sept 2023
  • Date of issue
    2023

History

  • Received
    26 May 2023
  • Accepted
    11 July 2023
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia https://actacirbras.com.br/ - São Paulo - SP - Brazil
E-mail: actacirbras@gmail.com