Acessibilidade / Reportar erro

Why it is called monosegmented flow analysis

Letter

Why it is Called Monosegmented Flow Analysis

Celio Pasquini

Instituto de Química, Universidade Estadual de Campinas, C.P. 6154, 13083-970 Campinas - SP, Brazil

Sirs: A recently published paper1 reviews a flow technique that was initially described in 1985, based on the introduction of the sample between two air or inert gas bubbles in the flow analysis manifold2. This procedure generates a reproducible sample monosegment having restricted convection mixing with the carrier solution resulting in low dispersion of the sample during its transport to the detector, even with long residence times. Figure 1 compares flow patterns generated by three well known flow analysis systems. From the chemical point of view the monosegmented technique permits performing determinations under non-steady state conditions, ensured by the high timing reproducibility found in the monosegmented system due the presence of but two gas bubbles. This monosegmented system contrasts with the previous multisegmented systems (see Fig. 1B) originally described by Skeggs3. However, the main advantage of the monosegmented system is that the signal is obtained after allowing most of the reaction to take place, under the conditions of restricted dispersion of the sample (i.e. near the equilibrium state). From the physical point of view the steady state flow is more closely approximated by a monosegmented system than by the flow injection system.


The first paper introducing the new flow principle named it as Monosegmented Continuous Flow Analysis (MCFA)2. This name remained in use until the recommendations of IUPAC on the classification and definition of analytical methods based on flowing media were published4,5. Since then, many authors have recognized that the word "continuous" does not contribute significantly to the description of the flow process, and have accepted the name recommended by IUPAC: Monosegmented Flow Analysis (MSFA)4,5. A survey of the Institute for Scientific Information (ISI) data base reveals that, so far, 29 papers have employed the "monosegmented" word to describe this flow principle2,6-33 while only 3 works appearing in the ISI indexed periodicals have employed the term Segmental Flow Injection1,34,35 referring to the same flow approach. Unfortunately, the author of the review1 ignores the IUPAC recommendations4,5, preferring to use the name that he and his co-authors suggested five years after34 the first paper on the monosegmented technique was published2. Note that in the paper in which the name SFIA was first coined34, no mention the of earlier papers2,6 was made.

In the review, the author suggests that "MSFA is not effective in emphasizing some essential features of the technique1". He argues that, since the sample is injected, the word "injection" should be used in the name, as proposed by him. In fact, in most cases the sample is injected into the manifold by using a special injection device capable of generating the monosegment. However, the monosegment can also be produced by successively aspirating air and sample and flushing the monosegment with a carrier liquid in a flow system23,29,36 or by using a time based sampling system17. No injection per se is employed in these cases while the characteristics of the monosegmented system are maintained. Thus the name need not/should not contain the term "injection", as was noted in the IUPAC recommendations4,5. On the other hand, it is possible to find at least one paper in the literature describing injection of the sample and subsequent multisegmentation37. The name Segmental Flow Injection Analysis does not distinguish between mono and multisegments, although they present completely different properties.

The review1 emphasizes early systems where the necessity of bubble removal was mandatory and resulted in significant dispersion, reducing the sensitivity or calling for larger sample volumes. An early paper was published aiming only at resolving this problem6. Actually, with the modern detection systems based on the microcomputer and digitized signals, the bubbles can pass through the detection cell, even when spectrophotometric detection is employed19,20,21,27. Figure 2 shows a typical signal obtained using a computer based system that precludes bubble removal. Obviously, it looks more like a steady state signal than a flow injection signal because the concentration along the monosegment is essentially constant and the monosegment is nearly homogeneous21,27. This results in the signal based on a monosegment being independent of differences of refractive index among samples, overcoming problems due to the Schlieren effect27.


Not mentioned in the review1 is the unsurpassed advantage of the monosegmented approach: the ability of precise sample location which is possible because the sample is unambiguously present between two air bubbles as a single segment. This feature allows attaining a simple and complete management of the flow analyzer. Reagents can be selectively delivered only into the monosegment, where they are homogeneously distributed, allowing for a low consumption of expensive chemicals and for the use of the same manifold for a sequential determination of various analytes21. Simple optical switches and conditioning electronic circuits capable of distinguishing between the refractive indexes of air and solution are used to produce electronic logical level transitions (TTL) to flag the controlling computer about the passage of the gas/liquid boundaries that define the monosegment38. In contrast with other flow systems, in a MSFA system it is always possible to know precisely where the sample is, allowing the appropriate action to be implemented with the objective of conditioning, reaction or measurement. For example, the detection of the monosegement is made only when it is inside the flow cell20. The operation can be controlled by looking at the position of the first bubble immediately at the outlet of the flow cell.

Nobody can deny the enormous contribution of the Flow Injection concept39 to Analytical Sciences in general. The principle of dispersion controlled by convection/ diffusion is at the heart of this flow technique and it is achieved only by the non-segmented flow approach. On the other hand, the monosegmented approach uses a different principle and the use of a similar terminology would be confusing, as correctly interpreted by IUPAC3,4. In fact, the MSFA works in a distinct way, restricting the dispersion by compartmentalization. In doing so it provides many advantages as well as some disadvantages.

Thus, even without considering the recommendations of IUPAC4,5 it should be clear that Monosegmented Flow Analysis (MSFA) is the appropriate name for a flow approach which proposes the introduction of the sample in between two air bubbles, defining a monosegment, especially in view of the fact that this approach permits new features not achieved in previous flow approaches. The name MSFA communicates the main feature of the flow technique (the existence of the monosegment) and should remain the name for this rapidly growing flow analysis procedure.

The author is grateful to Dr. Carol H. Collins for helpful suggestions and manuscript revision.

References

Received: September 30, 1999

FAPESP helped in meeting the publication costs of this article

  • 1.Zhi, Z.L. Trends Anal. Chem. 1998, 17, 411.
  • 2.Pasquini, C.; de Oliveira, W.A. Anal. Chem. 1985, 57, 2575.
  • 3.Skegg Jr., L.T. J. Clin. Pathol. 1957, 28, 311.
  • 4.Van der Linden, W.E. Pure Appl. Chem. 1994, 66, 2494.
  • 5.Zagatto, E.A.G.; Oliveira, C.C.; Collins, C.H. Quim. Nova 1999, 22, 143.
  • 6.Pasquini, C. Anal. Chem. 1986, 58, 2346.
  • 7.de Andrade, J.C.; Loboschi, E.M. Analyst 1988, 113, 295.
  • 8.de Andrade, J.C.; Ferreira, M.; Baccan, N.; Bataglia, O.C. Analyst 1988, 113, 289.
  • 9.Reis, B.F.; Arruda, M.A.Z.; Zagatto, E.A.G.; Ferreira, J.R. Anal. Chim. Acta 1988, 206, 253.
  • 10.de Andrade, J.C.; Eiras, S.P.; Bruns, R.E. Anal. Chim. Acta 1991, 255, 149.
  • 11.de Faria, L.C.; Pasquini, C. J. Autom. Chem 1992, 14, 213.
  • 12.de Andrade, J.C.; Bruns, R.E.; Eiras, S.D. Analyst 1993, 118, 213.
  • 13.Nogueira, A.R.A.; Brienza, S.M.B.; Zagatto, E.A.G.; Lima, JLFC.; Araújo, A.N. Anal. Chim. Acta 1993, 176, 121.
  • 14.dos Reis, B.F.; Zagatto, E.A.G.; Martelli, P.B.; Brienza, S.M.B. Analyst 1993, 118, 719.
  • 15.Facchin, I.; Martins, J.W.; Zamora, P.G.P.; Pasquini, C. Anal. Chim. Acta 1994, 285, 287.
  • 16.Facchin, I.; Pasquini, C. Anal. Chim. Acta 1995, 308, 231.
  • 17.de Andrade, J.C.; Poppi, R.J.; Coscione, A.R. J. Autom. Chem 1996, 18, 199.
  • 18.Bellato, C.R.; Pasquini, C. Analyst 1996, 121, 1923.
  • 19.Facchin, I.; Rohwedder, J.J.R.; Pasquini, C. J. Autom. Chem. 1997, 19, 33.
  • 20.da Silva, M.C.H. and Pasquini, C., Anal Chim. Acta 1997, 349, 377.
  • 21.Raimundo Jr., I.M.; Pasquini, C. Analyst 1997, 122, 1039.
  • 22.Araújo, A.N.; Catita, J.A.M.; Lima, J.L.F.C.; Zagatto, E.A.G. Fresenius J. Anal. Chem. 1998, 360, 100.
  • 23.Vieira, J.A.; Raimundo Jr., I.M.; Reis, B.F.; Zagatto, E.A.G.; Lima, J.L.F.C. Anal. Chim. Acta 1998, 366, 257.
  • 24.da Silva, M.C.H.; Rohwedder, J.J.R.; Pasquini, C. Anal. Chim. Acta 1998, 366, 223.
  • 25.Nielsen, S.; Hansen, E.H. Anal. Chim. Acta 1998, 366, 163.
  • 26.Facchin, I.; Pasquini, C. Quim. Nova 1998, 21, 60.
  • 27.Brito, V.O.; Raimundo Jr., I.M. Anal. Chim. Acta 1998, 371, 317.
  • 28.Sotomayor, P.T.; Raimundo, I.M.; Neto, G.O.; de Oliveira, W.A. Sensor Actuat. B-Chem. 1998, 51, 382.
  • 29.Ganzarolli, E.M.; Lehmkuhl, A.; de Queiroz, R.R.R.; Souza, I.G. Quim. Nova 1999, 22, 53.
  • 30.Smiderle, M.; Reis, B.F.; Rocha, F.R.P. Anal. Chim. Acta 1999, 386, 129.
  • 31.Honorato, R.S.; Silva, E.C.; de Araújo, M.C.U.; Veras, G.; Santos, S.R.B.; Lima, J.L.F.C.; Lapa, R.A.S. Lab. Robotics Automat. 1999, 11, 97.
  • 32.Araújo, A.N.; Catita, J.A.M.; Lima, J.L.F.C. Farmaco 1999, 54, 51.
  • 33.Martelli, P.B.; Reis, B.F.; Korn, M.; Lima, J.L.F.C. Anal. Chim. Acta 1999, 387, 165.
  • 34.Tian, L.C.; Sun, X.P.; Xu, Y.Y.; Zhi, Z.L. Anal. Chim. Acta 1990, 303, 183.
  • 35.Borzitsky, J.A.; Dvinin, A.V.; Petrukhin, O.M.; Urusov, Y.I. Anal. Chim. Acta, 1993, 274, 125.
  • 36.Peterson, K.L.; Logan B.K.; Christian G.D.; Ruzicka, J. Anal. Chim. Acta, 1997, 337, 99.
  • 37.Gardner, W.S.; Malczyk, J.M. Anal. Chem. 1983, 55, 1645.
  • 38.Raimundo Jr., I.M.; Pasquini, C. Lab. Micro. 1994, 13, 55.
  • 39.Ruzicka, J.; Hansen, E.H. Anal. Chim. Acta 1975, 78, 145.

Publication Dates

  • Publication in this collection
    01 June 2001
  • Date of issue
    Dec 1999

History

  • Received
    30 Sept 1999
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil