Acessibilidade / Reportar erro

A sensitive simultaneous determination of epinephrine and tyrosine using an iron(III) doped zeolite-modified carbon paste electrode

Abstracts

A Zeolite modified carbon paste electrode doped with iron(III) was used as a highly sensitive and selective electrochemical sensor for simultaneous determination of minor amounts of epinephrine (Ep) and tyrosine (Tyr) as the biologically important compounds. The results of differential pulse voltammetry (DPV) using this modified electrode show two well-resolved anodic waves for the oxidation of Ep and Tyr ,which makes it possible for simultaneous determination of both compounds. A linear range from 0.9 to 216 mmol L-1 for Ep at a constant concentration of 30 mmol L-1 Tyr in buffered solution (phosphate buffer, pH 3.0) was obtained from DPV measurement using this electrode with a correlation coefficient of 0.9998 and a detection limit of 0.44 mmol L-1. The linear range, which is obtained for Tyr in the presence of 30 mmol L-1 Ep, was in the range from 1.2 to 90 µmol L-1 with a correlation coefficient of 0.9989 and a detection limit of 0.32 mmol L-1. The modified electrode had good reproducibility (RSD < 2.5%), low detection limit (sub-micromolar) and high sensitivity for the detection of both Ep and Tyr with a very high stability in its voltammetric response. The analytical performance of this sensor has been evaluated for detection of Ep and Tyr in human serum and in a pharmaceutical sample with satisfactory results.

Epinephrine; tyrosine; Fe(III) doped zeolite; modified carbon paste electrode


Um eletrodo de pasta de carbono modificado com zeólitas e dopado com ferro(III) foi usado como um sensor eletroquímico de alta sensibilidade e seletividade para a determinação simultânea de pequenas quantidades de compostos biologicamente importantes como epinefrina (Ep) e tirosina (Tyr). Os resultados da voltametria de pulso diferencial (DPV) usando este eletrodo modificado mostra duas ondas anódicas bem traçadas para a oxidação da Ep e da Tyr, as quais tornam possíveis a determinação simultanêa destes compostos. A faixa linear de 0,9 a 216 mmol L-1 para a Ep em uma concentração fixa de 30 mmol L-1 Tyr em solução tampão fosfato, pH 3,0 foi obtida das medidas de DPV usando este eletrodo, com um coeficiente de correlação de 0,9998 e limite de quantificação igual a 0,44 mmol L-1. A linearidade obtida para a Tyr na presença de 30 mmol L-1 de Ep, foi de 1,2 a 90 mmol L-1 com um coeficiente de correlação de 0,9989 e limite de quantificação de 0,32 mmol L-1. O eletrodo modificado apresentou uma boa reprodutibilidade (RSD< 2.5%), baixo limite de quantificação (sub-micromolar) e alta sensibilidade para a detecção de ambos Ep e Tyr com uma elevada estabilidade em sua resposta voltamétrica. O desempenho analítico deste sensor tem sido avaliado para a detecção de epinefrina e tirosina em soro humano e em amostras farmacêuticas com resultados satisfatórios.


ARTICLE

A sensitive simultaneous determination of epinephrine and tyrosine using an iron(III) doped zeolite-modified carbon paste electrode

Ali Babaei* * e-mail: a-babaei@araku.ac.ir ; Somaieh Mirzakhani; Balal Khalilzadeh

Department of Chemistry, Arak University, Arak, P.O. Box 38156-879, Iran

ABSTRACT

A Zeolite modified carbon paste electrode doped with iron(III) was used as a highly sensitive and selective electrochemical sensor for simultaneous determination of minor amounts of epinephrine (Ep) and tyrosine (Tyr) as the biologically important compounds. The results of differential pulse voltammetry (DPV) using this modified electrode show two well-resolved anodic waves for the oxidation of Ep and Tyr ,which makes it possible for simultaneous determination of both compounds. A linear range from 0.9 to 216 mmol L-1 for Ep at a constant concentration of 30 mmol L-1 Tyr in buffered solution (phosphate buffer, pH 3.0) was obtained from DPV measurement using this electrode with a correlation coefficient of 0.9998 and a detection limit of 0.44 mmol L-1. The linear range, which is obtained for Tyr in the presence of 30 mmol L-1 Ep, was in the range from 1.2 to 90 µmol L-1 with a correlation coefficient of 0.9989 and a detection limit of 0.32 mmol L-1. The modified electrode had good reproducibility (RSD < 2.5%), low detection limit (sub-micromolar) and high sensitivity for the detection of both Ep and Tyr with a very high stability in its voltammetric response. The analytical performance of this sensor has been evaluated for detection of Ep and Tyr in human serum and in a pharmaceutical sample with satisfactory results.

Keywords: Epinephrine, tyrosine, Fe(III) doped zeolite, modified carbon paste electrode

RESUMO

Um eletrodo de pasta de carbono modificado com zeólitas e dopado com ferro(III) foi usado como um sensor eletroquímico de alta sensibilidade e seletividade para a determinação simultânea de pequenas quantidades de compostos biologicamente importantes como epinefrina (Ep) e tirosina (Tyr). Os resultados da voltametria de pulso diferencial (DPV) usando este eletrodo modificado mostra duas ondas anódicas bem traçadas para a oxidação da Ep e da Tyr, as quais tornam possíveis a determinação simultanêa destes compostos. A faixa linear de 0,9 a 216 mmol L-1 para a Ep em uma concentração fixa de 30 mmol L-1 Tyr em solução tampão fosfato, pH 3,0 foi obtida das medidas de DPV usando este eletrodo, com um coeficiente de correlação de 0,9998 e limite de quantificação igual a 0,44 mmol L-1. A linearidade obtida para a Tyr na presença de 30 mmol L-1 de Ep, foi de 1,2 a 90 mmol L-1 com um coeficiente de correlação de 0,9989 e limite de quantificação de 0,32 mmol L-1. O eletrodo modificado apresentou uma boa reprodutibilidade (RSD< 2.5%), baixo limite de quantificação (sub-micromolar) e alta sensibilidade para a detecção de ambos Ep e Tyr com uma elevada estabilidade em sua resposta voltamétrica. O desempenho analítico deste sensor tem sido avaliado para a detecção de epinefrina e tirosina em soro humano e em amostras farmacêuticas com resultados satisfatórios.

Introduction

Epinephrine (Ep), Scheme 1 (a), often called adrenaline, is one of the most important neurotransmitters in mammalian central nervous systems, existing in the nervous tissue and body fluid, and controlling the nervous system in the performance of a series of biological reactions and nervous system chemical processes. Many biological reactions, and the nervous system chemical processes can be considered as a type of organic electrochemical process.1,2 Therefore, a study on the electrochemical behavior of Ep is a great help in understanding the effects of the nervous system and artificial substitutes, and is of great significance to pharmacological research and the life sciences. Determination of concentrations of Ep is important for the study of neurotransmission, for diagnosis of neurological disorders, such as Parkinson's, and for developing medicines to treat the diseases.3 Tyrosine (Tyr), Scheme 1 (b), is a vital constituent of proteins, which are indispensable in human nutrition for establishing and maintaining a positive nitrogen balance,4 and is the precursor of dopa, dopamine, thyroxin, and epinephrine hormone or neurotransmitters.5,6 The absence of Tyr could cause albinism and alkaptonuria, while a high L-tyrosine concentration in culture medium results in increased sister chromatid exchange. Thus, the analytical determination of Tyr is a pharmacological necessity.

Various approaches for Ep analysis include methods such as fluorescence,7-10 chemiluminescence,11 radioimmunoassay,12 capillary electrophoresis13-15 and liquid chromatography coupled with several types of detection methods.16,17 The detection of tyrosine is usually accomplished by spectrophotometric,18 fluorimetric,19 and liquid chromatography-tandem mass spectrometry,20 gas chromatography-mass spectrometry,21 and high-performance liquid chromatography.22 These methods are very significant due to their importance in separation science and provide very low detection limits. However, the majority of these methods have some disadvantages, include sample pre-treatment, time consuming and high analysis cost. These disadvantages prevent them for routine analysis. Therefore development of a sensitive and rapid method with low cost for determination of Ep and Tyr is necessary. The development and application of novel electrochemical sensors for Ep23-26 and Tyr27-30 analysis, with respect to their sensitivity, accuracy, and simplicity, has been of greater interest in recent years.

Tyr is a precursor in the production of Ep in biological samples. It has been found that a decrease in the amount of Tyr leads to a decrease in production of Ep in some animals31 Tyr and Ep compounds presenting in blood serum. It seems that the application of a sensor for simultaneous determination of Ep and Tyr would be useful to control concentrations of those compounds in some patients. There have been no reports on the application of an electrochemical sensor for simultaneous determination of Ep and Tyr in the literature.

The continuous interest in modified carbon paste electrodes has increased the use of inorganic materials as electrode modifier agents. Among the inorganic materials, zeolites have been widely used as ion exchangers because of their unique size, shape and charge selectivity, high ion exchange capability, high thermal stability, low cost and resistance to extreme conditions.32 Substantial efforts have been dedicated to the development of sensors using zeolite-modified electrodes.33-37 In this work, we present the application of the iron(III) doped zeolite modified carbon paste electrode (Fe3+/ZMCPE), prepared by mixing iron(III) doped zeolite as the modifier with carbon paste electrode (CPE), for simultaneous determination of Ep and Tyr. To the best of our knowledge this is the first report on the application of Fe3+/ZMCPE for the determination of these compounds. Finally the analytical performance of this sensor for determination of Ep and Tyr in epinephrine injection as a pharmaceutical sample and human serum sample, respectively, was evaluated using the differential pulse voltammetry (DPV) method.

Experimental

Reagents and solutions

All chemicals were analytical grade from Sigma Chemical Company and used without further purification. All solutions were prepared from triply distilled water. Phosphate solution (0.15 mol L-1) was prepared by dissolving 10.1 mL of concentrated orthophosphoric acid in water and diluting it to 1.0 L in a volumetric flask. The buffer solutions were prepared by addition of 7.5 mol L-1 sodium hydroxide to the phosphoric acid solution to reach appropriate pH values, then the solution volume was adjusted to 1.0 L. Stock solutions of 1 mmol L-1 Ep and Tyr were freshly prepared in distilled water. Voltammetric experiments on Ep and Tyr were carried out in 0.15 mol L-1 phosphate buffer at pH 3.0. Zeolite NaY was synthesized in our laboratory as previously reported.38

Apparatus

All the voltammetric measurements were carried out using modified carbon-paste (Fe3+Y/ZMCPE ) as a working electrode, Ag|AgCl|3 mol L-1 KCl as the reference electrode and platinum wire as the auxiliary electrode. Differential pulse voltammetry experiments were carried out with pulse amplitude of 50 mV, scan rate of 20 mV s-1 and a pulse interval of 0.3 s, using an Autolab PGSTAT 30 Potentiostat Galvanostat (EcoChemie, The Netherlands) coupled with a 663 VA stand (Metrohm Switzerland). Cyclic voltammetric measurements were carried out using Autolab PGSTAT 30 Potentiostat Galvanostat by means of three electrode configuration as described for DPV experiments without applying accumulation time at various scan rates. All potentials given are with respect to the potential of the reference electrode. pH measurements were performed with a Metrohm 744 pHmeter using a combination glass electrode.

Electrode preparation

The iron(III) doped zeolite was prepared as previously reported.37 Briefly, 1 g of NaY zeolite was lightly ground and immersed in 250 mL of 0.01 mol L-1 FeCl3 solution and stirred for 48 h. The Fe3+ exchanged zeolite was carefully washed with HCl solution (pH 2.0) to remove occluded material and surface-adherent salt, washed with triply distilled water to remove chloride ion, and finally dried in room temperature. We have recently reported characterization of the structure of the iron(III) doped zeolite structure.39

The zeolite-modified electrode was prepared by mixing 60% of graphite, 10% of zeolite powders and 30% of mineral oil (m/m). Then the resulting composite was dispersed in diethyl ether solvent to obtain better homogeneity. The mixture was stirred by a magnetic stirrer till the solvent evaporated completely. The prepared composite material was then dried at room temperature for 24 h. The obtained paste was packed into the end of an insulin syringe (i.d. 2 mm) and arranged with copper wire serving as external electric contact. The unmodified carbon paste electrode (CPE) was also prepared in the same way as the Fe3+Y/ZMCPE preparation procedure, except that no iron(III) doped zeolite was added. The electrode surface was smoothed on a piece of weighing paper. A new surface could be obtained by pushing an excess of paste out of the tube, removing the excess, and mechanically polishing again the electrode surface.

Results and Discussion

Electrochemical oxidation of epinephrine and tyrosine

The cyclic voltammograms were recorded for Ep and Tyr at Fe3+/ZMCPE as shown in Figure 1. As can be seen at the surface of the electrode, oxidations of Ep and Tyr are irreversible at the surface of the electrode. These results indicate the slow electron transfer rate for oxidation of these biomolecules at the modified electrode. Such sluggish electron transfer kinetics is related to the electrode fouling caused by the deposition of Ep and Tyr and their oxidation products. Ep shows a reduction peak at -0.2 V indicating irreversible reduction of Ep according to Scheme 2a. The effect of potential scan rate on the oxidation response of Ep and Tyr were investigated in the 5-200 mV s-1 scan rate range of scan rate (not shown). A linear relationship between the anodic peak current and the square root of scan rate were found for respectively Ep and Tyr as follows:


However, a plot of Ipa for Ep and Tyr vs. n were not linear. The linear relationship between peak currents and square root of scan rates is indicative that the oxidation currents were diffusion controlled, which is the ideal case for quantitative measurements. These phenomena could be due to the rates of adsorption of Ep and Tyr on the electrode surface being slower than the diffusion rates in such a scan rate range.

The differential pulse voltammograms recorded for Ep and Tyr at bare carbon paste (CPE), zeolite modified carbon paste (ZMCPE) and Fe(III) doped modified carbon paste (Fe3+/ZMCPE) electrodes, are shown in Figure 2. Curve a shows the voltammograms of 80 mmol L-1 Ep and 80 μmol L-1 of Tyr in phosphate buffer (pH 3.0) at CPE. Curves b and c display voltammograms of Ep and Tyr under the same conditions as for curve a at the ZMCPE and the Fe3+Y/ZMCPE, respectively. It can be seen for the CPE that very small oxidation peaks were observed for Ep and Tyr. The ZMCPE showed a slight enhancement of the Ep oxidation peak current when compared with CPE. However, no enhancement of the Tyr oxidation peak current was observed. Ep can adsorb a proton at pH 3.0 to form the corresponding cation and therefore could be adsorbed by the zeolite due to the cation exchange character of the zeolite NaY structure. The differential pulse voltammograms of Ep and Tyr showed excellent improvement in oxidation peak currents for those compounds (curve (c)).There are some reports on the tendency of complex formation between iron(III) and Ep,40 and iron(III) and Tyr.41 Therefore Ep and Tyr could become more accumulated on the electrode surface due to their interaction with iron(III). Consequently, application of the Fe3+Y/ZMCPE leads to enhancement of current sensitivity and selectivity in simultaneous determinations of Ep and Tyr compounds.


Effects of pH

The effects of pH on the electrochemical response of the Fe3+Y/ZMCPE towards the simultaneous determination of Ep and Tyr solutions were investigated. Variations of peak current with respect to pH of the electrolyte in the pH range from 2.0 to 7.0 are shown in Figure 3. It can be seen that the anodic peak current of Ep increases slightly with decrease in the solution pH from 7.0 to 3.0. In such acidic media Ep (pKa 8.6) would be protonated and then protonated Ep could become accumulated on the Fe3+Y/ZMCPE surface due to the cation exchange properties of the zeolite or the effect of the electrode negative charge at the accumulation potential of -0.2 V. Further decrease of pH leads to the corresponding Ep oxidation peak current diminishing. In highly acidic solution the competition between the proton and the protonated form of Ep to adsorb on the Fe3+Y/ZMCPE could have occurred. The oxidation peak current of Tyr was almost independent of variation in pH. Therefore, the optimum solution pH selected was 3.0. In addition, all the anodic peak currents for the oxidation of Ep and Tyr shifted towards more negative potential with an increase in pH, showing that protons have taken part in their electrode reaction processes. The relationship between pH and the corresponding peak potentials for Ep and Tyr are shown below:


The slope of EPvs. pH are 60 and 54 mV/pH which are very close to the anticipated Nernstian value for the process in which the number of protons are equal to the number of transferred electrons. This conclusion is in accordance with the known electrochemical reactions of Ep and Tyr.42,43 It has been known that Ep can be oxidized via a two electron and two proton process42 and Tyr can be oxidized via a one electron and one proton process.43

Effects of accumulation potential

The effects of accumulation potential on the anodic peak currents of Ep and Tyr solutions were examined over the range -0.5 to 0.3 V. The results showed that the peak current of Ep was slightly increased at an accumulation potential of -0.2 V. The oxidation peak current of Tyr was almost independent of applied accumulation potential. Thus the accumulation potential of -0.2 V was selected as the optimum accumulation potential for further experiments.

Effects of accumulation time

The effects of accumulation time on differential pulse anodic peak currents for Ep and Tyr were investigated. Initially the peak currents for these compounds increase with accumulation time up to 40 s, however after 40 s of accumulation time, the peak currents reach a plateau. As a consequence, the accumulation time of 40 s was chosen as an optimum time for further experiments.

Effect of modifier percent

The effect of Fe3+ doped zeolite as a modifier in the composition of Fe3+Y/ZMCPE is shown in Figure 4. The results showed that the anodic peak current of Ep and Tyr reached the highest value at 15% (m/m) of the modifier at constant value of 30% (m/m) of mineral oil. Higher concentration of modifier showed a decrease in peak current. This is presumably due to reduction of conductivity of the electrode due to decrease in graphite powder concentration. Consequently a carbon paste composition of 15% modifier zeolite, 55% graphite and 30% mineral oil was used in further studies.


Linear range, detection limit and reproducibility of the method

To verify the linear relationship between anodic peak currents and Ep and Tyr concentrations several calibration curves were constructed under optimum conditions as accumulation potential of -0.2 V, an accumulation time of 30 s and 15% (m/m) iron(III) doped zeolite as a modifier in the Fe3+Y/ZMCPE, in 0.15 mol L-1 phosphate buffer (pH 3.0) solutions. Figures 5 and 6 show differential pulse voltammograms obtained at Fe3+Y/ZMCPE in various concentrations of Ep and Tyr, respectively. Figure 5 shows DPV at various concentrations of Ep in the presence of 30 mmol L-1 Tyr. A linear dynamic range from 0.9 mmol L-1 to 216 mmol L-1, with a calibration equation of Ip(nA) = 34.343c (mmol L-1) + 2.3197 (R2 = 0.9998), and a detection limit of 0.44 mmol L-1 was obtained. A linear relationship was found for Tyr in the 1.2 to 90 mmol L-1 range containing 30 mmol L-1 Ep, with a calibration equation of Ip(nA) = 9.3454 c(mmol L-1) + 10.635 (R2 = 0.9988) and a detection limit of 0. 32 mmol L-1 (Figure 6).



The linear dynamic range and detection limit of this method were compared with some recent voltammetric methods for determination of Ep or Tyr (Table 1). The results show that the proposed method is preferable in determinations of both Ep and Tyr.

Interference studies

The influences of common interfering species were investigated in the presence of a mixture of 30 mmol L-1 Ep and 30 mmol L-1 Tyr (Table 2). The results showed that concentrations of the interfering species did not significantly influence the height of the peak currents. The tolerance limit was defined as the concentrations which give an error of < 10% in the determination of Ep and Tyr compounds.

Analytical applications

Applicability of the Fe3+/ZMCPE was examined for the determination of Tyr in human serum and Ep in epinephrine injections and serum. The human serum was diluted with phosphate buffer solution (0.15 mol L-1, pH 3.0) and a 10.0 mL portion was transferred to the voltammetric cell, individually. The samples were diluted 20 times and spiked with various concentrations of Tyr and Ep. The concentrations were obtained by applying standard addition method. Using the proposed methods described above the diluted (200 times) epinephrine injection was analyzed by applying standard addition method. In addition, a certain volume of standard solution of Ep was added into the corresponding injection for testing recovery. The results were shown in Table 3. The recoveries were from 93.3 to 103.3%, showing that the proposed methods could be efficiently used for the determination of trace amounts of these compounds in biological systems and pharmaceutical preparations.

Reproducibility and long-term stability of the electrode

The main advantage of using the Fe3+Y/ZMCPE is easy and quick surface renewal after each use. Thus, the repeatability of the analytical signal has been studied. Indeed, the relative standard deviation (RSD) of 2.73% and 1.01% has been obtained for 80 mmol L-1 Ep and 60 mmol L-1 Tyr, respectively in ten consecutive determinations. It should be noted that the Fe3+Y/ZMCP electrode surface was polished, as described in experimental section, before each consecutive determination. Another attraction of the proposed modified electrode was that the resulting carbon paste electrode showed a good long-term stability. Stability of the proposed electrode was tested by measuring the decrease in voltammetric current during repetitive DPV measurements of Ep and Tyr with Fe3+Y/ZMCPE stored in solution or air. For example, determination of 40 mmol L-1 Ep, 40 mmol L-1 Tyr in 0.15 mol L-1 phosphate buffer solution (pH 3.0), when the modified electrode was subjected to an experiment every 30 min, gave no significant change in the voltammetric currents up to 24 h. When the electrode was stored in the atmosphere, the current response remained almost unchanged for 40 days. The high stability of the zeolite-modified carbon paste electrode could be related to the strong affinity of zeolite Y for iron(III)44 and the insolubility of the zeolite in water.

Conclusions

In the present work, we introduced a new electrode based on iron(III) doped zeolite modified carbon paste. Iron(III) loaded in a zeolite matrix can increase anodic peak currents by adsorption of Ep and Tyr compounds on the electrode surface. The results indicated that the Fe3+Y/ZMCPE facilitates the simultaneous determination of Ep and Tyr with good sensitivity and selectivity. The electrode showed high stability in repetitive experiments due to the high affinity of zeolite Y for iron(III) and the low solubility of the zeolite in water. The effects of potential interfering ions were studied, and it was found that the proposed procedure was free from interferences of most common interfering ions and organic compounds. The proposed sensor was used with satisfactory results in determinations of Ep and Tyr in some real samples like diluted human serum and epinephrine injection without the necessity of using sample pretreatment or any time-consuming extraction or evaporation steps prior to the analysis. The simple fabrication procedure, good reproducibility, high stability, wide linear dynamic range, low detection limit, high sensitivity and a distinct advantage of polishing in the event of surface fouling, suggest that this electrode is an attractive candidate as a sensor for practical applications.

Acknowledgments

The authors gratefully acknowledge the financial support of this work by the research council of Arak University. Thanks to Dr. A. James McQuillan from Otago University in New Zealand for his valuable comments.

Received: December 22, 2008

Web Release Date: November 12, 2009

  • 1. Zhao, Q.; Gan, Z.; Zhuang Q.; Electroanalysis 2002, 14, 1609.
  • 2. Ijima, S.; Nature 1991, 354, 56.
  • 3. Wightman, R. M.; May, L. J.; Michael, A. C.; Anal. Chem. 1988, 60, 769A.
  • 4. Jin, G. P.; Lin, X. Q.; Electrochem. Commun. 2004, 6, 454.
  • 5. Carlsson, A.; Lindqvist, M.; Arch, N.S.; Pharmacology 1978, 303, 157.
  • 6. Femstrom, H.F.; Femstrom, J.D.; Life Sci. 1995, 57, 97.
  • 7. Nohta, H.; Yukizawa, T.; Ohkura, Y.; Yoshimura, M.; Ishida, J.; Yamaguchi, M.; Anal. Chim. Acta 1997, 344, 233.
  • 8. Llavero, M. P.; Rubio, S.; Gomez-Hens, A.; Perez Bendito, D.; Anal. Chim. Acta 1990, 229, 27.
  • 9. Canizares, P.; Luque De Castro, M. D.; Anal. Chim. Acta 1995, 317, 335.
  • 10. Guo, Y.; Yang, J.; Wu, J.; Du, A.; J. Fluores. 2005, 15, 131.
  • 11. Guo, Z.; Dong, S., Electroanalysis 2005, 17, 607.
  • 12. Murphy, J. F.; Davies, D.H.; Smith, C. J.; J. Immunol. Methods 1992, 154, 89.
  • 13. Wei, S.; Song, G.; Lin, J.-M.; J. Chromatogr., A 2005, 1098, 166.
  • 14. Zhu, R.; Kok, W. T.; Anal. Chem. 1997, 69, 4010.
  • 15. Siren, H.; Karjalainen, U.; J. Chromatogr., A 1999, 853, 527.
  • 16. Zhang, S.; Xu, Q.; Zhang, W.; Jin, L.; Jin J.-Y.; Anal. Chim. Acta 2001, 427, 45.
  • 17. Xu, F.; Gao, M.; Shi, G.; Wang, L. Zhang, W.; Xue, J.; Jin, L.; Jin, J.-Y.; Anal. Chim. Acta 2001, 439, 239.
  • 18. Azuma, Y.; Maekawa, M.; Kuwabara, Y.; Nakajima, T.; Taniguchi, K.; Kanno, T.; Clin. Chem. 1989, 35, 1399.
  • 19. Wang, F.; Wu, K. Z.; Qing, Y.; Ci, Y. X.; Anal. Lett. 1992, 25, 1469.
  • 20. Orhan, H.; Vermeulen, N. P. E.; Tump, C.; Zappey, H.; Meerman, J. H. N.; J. Chromatogr., B 2004, 799, 245.
  • 21. Deng, C. H.;. Deng, Y. H; Wang, B.; Yang, X. H.; J. Chromatogr., B 2002, 780, 407.
  • 22. Sabine, L.; Jean, P. G.; Joelle, S.; Bernard, B.; J. Chromatogr., B 1997, 696, 9.
  • 23. Yao, H.; Sun, Y.; Lin, X.; Tang, Y.; Liu, A.; Li, G.; Li, W.; Zhang, S.; Anal. Sci. 2007, 23, 677.
  • 24. Qiao, J. X.; Luo, H. Q.; Li, N. B.; Colloids Surf., B 2008, 62, 31.
  • 25. Luczak, T.; Electroanalysis 2008, 20, 1317.
  • 26. Hu, W.; Sun, D.; Ma, W.; Chem. Anal. (Warsaw, Pol.) 2008, 53, 703.
  • 27. Jin, G.-P.; Lin, X.-Q.; Electrochem. Commun. 2004, 6, 454.
  • 28. Xu, Q.; Wang; S.-F.; Microchim. Acta 2005, 151, 47.
  • 29. Zhao, G.; Qi, Y. Electroanalysis 2006, 18, 830.
  • 30. Yogeswaran, U.; Thiagarajan, S.; Chen, S. M.; Carbon 2007, 45, 2783.
  • 31. Lee, P.V.; J. Pharmacol. Exp. Ther. 1954, 112, 291.
  • 32. Walcarius, A.; Electroanalysis 1996, 8, 971.
  • 33. Wang, J.; Walcarius, A.; J. Electroanal. Chem 1996, 407, 183.
  • 34. Wang, J.; Walcarius, A.; J. Electroanal. Chem. 1996, 404, 237.
  • 35. Rando, M. D. C.; Rodriguez, I. N.; Cisneros, H. H.; Anal. Chim. Acta 1998, 370, 231.
  • 36. Jiang, Y.; Zou, M.; Yuan, K.; Xu, H.; Electroanalysis 1999, 11, 254.
  • 37. Mazlum Ardakani, M.; Akrami, Z.; Kazemian, H.; Zare, H. R.; J. Electroanal. Chem. 2006, 586, 31.
  • 38. Breck, D. W.; Tonawanda, N. Y.; assigned to Union Carbide Corporation; Patent 3130007, 1964
  • 39. Babaei, A.; Zendehdel, M.; Khalilzadeh, B.; Taheri, A.; Colloids Surf., B 2008, 66, 226.
  • 40. Sandra, L. J.; Sue, E.; Lovis, G; J. Inorg. Biochem. 1997, 66, 165.
  • 41. Durmus, A.; Eichen, C.; Sift, B. H.; Kratel, A.; Kappl, R.; Huttermann, J. Krebs, B.; Eur. J. Biochem. 1999, 260, 709.
  • 42. Chen, S.-M.; Peng, K.-T .; J. Electroanal. Chem 2003, 547 179.
  • 43. Jin, G.-P.; Lin, X.-Q .; Electrochem. Commun. 2004, 6, 454.
  • 44. Jiang, Y.; Zou, M.; Yuan, K.; Xu, H.; Electroanalysis 1999, 11, 254.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      14 Oct 2011
    • Date of issue
      2009

    History

    • Received
      22 Dec 2008
    • Accepted
      12 Nov 2009
    Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
    E-mail: office@jbcs.sbq.org.br