A multi-walled carbon nanotube-modified glassy carbon electrode as a new sensor for the sensitive simultaneous determination of paracetamol and tramadol in pharmaceutical preparations and biological fluids

Abstracts

A chemically modified electrode was constructed based on a multi-walled carbon nanotube-modified glassy carbon electrode (MWCNTs/GCE). It was demonstrated that this sensor can be used for the simultaneous determination of the pharmaceutically important compounds paracetamol (PAR) and tramadol (TRA). The measurements were carried out by the application of differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA) methods. Application of the DPV method demonstrated that in phosphate buffer (pH 7.5) there was a linear relationship between the oxidation peak current and the concentration of PAR over the range 0.5 µmol L-1 to 210 µmol L-1. A similar linear correlation between oxidation peak current and concentration was observed for TRA over the range of 2 µmol L-1 to 300 µmol L-1. Under optimal conditions the modified electrode exhibited high sensitivity, selectivity and stability for both PAR and TRA determination, making it a suitable sensor for the simultaneous submicromolar detection of PAR and TRA in solutions. The analytical performance of this sensor has been evaluated for detection of PAR and TRA in human serum, human urine and some pharmaceutical preparations with satisfactory results.

paracetamol; tramadol; carbon nanotube; modified glassy carbon; electrochemical sensor


Um eletrodo modificado quimicamente foi construído, baseado em eletrodo de carbono vítreo modificado por nanotubos de carbono de parede múltipla (MWCNTs/GCE). Demonstrou-se que este sensor pode ser usado para a determinação simultânea de compostos com importância farmacêutica, como o paracetamol (PAR) e o tramadol (TRA). As medidas foram realizadas com aplicação de voltametria de pulso diferencial (DPV), voltametria cíclica (CV) e cronoamperometria (CA). A aplicação do método DPV demonstrou que em tampão fosfato (pH 7,5) há uma relação linear entre a corrente de pico de oxidação e a concentração de PAR no intervalo entre 0,5 µmol L-1 e 210 µmol L-1. Uma correlação linear semelhante, entre a corrente de pico de oxidação e a concentração, foi observada para TRA no intervalo de 2 µmol L-1 a 300 µmol L-1. Sob condições ótimas, o eletrodo modificado exibiu alta sensibilidade, seletividade e estabilidade para a determinação de ambos, PAR e TRA, tornando este, um sensor adequado para a detecção submicromolar simultânea de PAR e TRA, em soluções. O desempenho analítico deste sensor foi avaliado para detecção de PAR e TRA em soro e urina humanos e em algumas preparações farmacêuticas, com resultados satisfatórios.


ARTICLE

A multi-walled carbon nanotube-modified glassy carbon electrode as a new sensor for the sensitive simultaneous determination of paracetamol and tramadol in pharmaceutical preparations and biological fluids

Ali BabaeiI,II,* * e-mail: a-babaei@araku.ac.ir ; Ali Reza TaheriI; Mohammad AfrasiabiIII

IDepartment of Chemistry and Research Center for Nanotechnology, University of Arak, P.O. Box 38156-879 Arak, Iran

IIResearch Center for Nanotechnology, University of Arak, P.O. Box 38156-879 Arak, Iran

IIIIslamic Azad University, Shoushtar Branch, Young Researchers Club, Shoushtar, Iran

ABSTRACT

A chemically modified electrode was constructed based on a multi-walled carbon nanotube-modified glassy carbon electrode (MWCNTs/GCE). It was demonstrated that this sensor can be used for the simultaneous determination of the pharmaceutically important compounds paracetamol (PAR) and tramadol (TRA). The measurements were carried out by the application of differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA) methods. Application of the DPV method demonstrated that in phosphate buffer (pH 7.5) there was a linear relationship between the oxidation peak current and the concentration of PAR over the range 0.5 µmol L-1 to 210 µmol L-1. A similar linear correlation between oxidation peak current and concentration was observed for TRA over the range of 2 µmol L-1 to 300 µmol L-1. Under optimal conditions the modified electrode exhibited high sensitivity, selectivity and stability for both PAR and TRA determination, making it a suitable sensor for the simultaneous submicromolar detection of PAR and TRA in solutions. The analytical performance of this sensor has been evaluated for detection of PAR and TRA in human serum, human urine and some pharmaceutical preparations with satisfactory results.

Keywords: paracetamol, tramadol, carbon nanotube, modified glassy carbon, electrochemical sensor

RESUMO

Um eletrodo modificado quimicamente foi construído, baseado em eletrodo de carbono vítreo modificado por nanotubos de carbono de parede múltipla (MWCNTs/GCE). Demonstrou-se que este sensor pode ser usado para a determinação simultânea de compostos com importância farmacêutica, como o paracetamol (PAR) e o tramadol (TRA). As medidas foram realizadas com aplicação de voltametria de pulso diferencial (DPV), voltametria cíclica (CV) e cronoamperometria (CA). A aplicação do método DPV demonstrou que em tampão fosfato (pH 7,5) há uma relação linear entre a corrente de pico de oxidação e a concentração de PAR no intervalo entre 0,5 µmol L-1 e 210 µmol L-1. Uma correlação linear semelhante, entre a corrente de pico de oxidação e a concentração, foi observada para TRA no intervalo de 2 µmol L-1 a 300 µmol L-1. Sob condições ótimas, o eletrodo modificado exibiu alta sensibilidade, seletividade e estabilidade para a determinação de ambos, PAR e TRA, tornando este, um sensor adequado para a detecção submicromolar simultânea de PAR e TRA, em soluções. O desempenho analítico deste sensor foi avaliado para detecção de PAR e TRA em soro e urina humanos e em algumas preparações farmacêuticas, com resultados satisfatórios.

Introduction

Carbon nanotubes (CNT) are a form of carbon1,2 that, because of their physicochemical features, large surface area, high chemical stability, outstanding bio-compatibility, high conductance, good tensile strength, high catalytic capability and fast electron transfer rate, have been recognized as one of the almost quintessential nano-materials.3,4

Paracetamol (PAR) (acetaminophen, N-acetyl-p-aminophenol) is a widely used analgesic antipyretic drug that has actions similar to aspirin. It represents a suitable alternative for the patients who are sensitive to aspirin and is a major ingredient in numerous cold and influenza medications.5 While safe up to therapeutic doses, an overdose can lead to the accumulation of toxic metabolites, which may cause severe and sometimes fatal hepatoxicity and nephrotoxicity.6 Large doses, chronic use or concomitant use with alcohol or other drugs can also cause skin rashes, inflammation of the pancreas and liver disorders.7 The product of the hydrolytic degradation of paracetamol (4-aminophenol) can be present in pharmaceutical preparations as a degradation product of paracetamol or as a synthetic intermediate. It can be dangerous and cause teratogenic effects and nephrotoxicity.8

Tramadol (TRA) is a centrally acting analgesic that was first introduced in Germany in 1977. Today it has become the most prescribed opioid worldwide.9 It is generally said to be devoid of many of the serious adverse effects of traditional opioid receptor agonists such as the risk for respiratory depression10 and drug dependence.11 Based on this, in contrast to other opioids, the abuse potential of tramadol is considered to be either low or absent.9,12 Hence, tramadol is the only clinically available non-scheduled opioid.13 However recently reported results of post-marketing surveillance and case reports14 have shown that tramadol abuse and tramadol related fatalities have been noted. Its overall analgesic efficacy is comparable to that achieved using equianalgesic doses of morphine or alfentanil.15

The analgesic efficiency of TRA can be enhanced by combination with a non-opoid analgesic such as PAR.16 This combination is also used in patients when it is not possible to prescribe a nonsteroid anti-inflammatory, prior to treatment with potent opioids, and to spare the secondary effects of codeine may occur with high doses or in extended treatments.17 Because of their effectiveness and security, synergistic pharmaceutical formulations of PAR and TRA (e.g. 325 mg of PAR with 37.5 mg of TRA) are commonly used in the pain treatment. Consequently the determination of the levels of these compounds present in pharmaceuticals in order to prevent overdoses leading to toxic effects is of considerable importance.

A number of quantitative analytical methods have been reported for PAR determination in pharmaceutical formulations and biological samples, individually or associated to other active compounds. These include capillary electrophoresis,18 fluorimetry,19 titrimetry,20 flow injection analysis (FIA) (using different methods of detection),21 liquid chromatography,22 spectrophotometry,23 spectrofluorometry24 and chemiluminescence.25 For the determination of Tramadol itself, fewer analytical methodologies have been proposed. These are mainly based on high performance liquid chromatography (HPLC) coupled to different detectors,26 UV,27 fluorescence,28 electrochemical,29 capillary isotachophoresis,30 capillary gas chromatography,31 gas chromatography,32 gas chromatography-mass spectrometry,33 liquid chromatography-mass spectrometry (LC-MS)34 capillary electrophoresis,35 high performance thin layer chromatography (HPTLC),36 spectrophotometry37 and spectrofluorometry.38 In spite of the large number of published reports on the individual determination of PAR or TRA, there have been only a few reports of the simultaneous determination of PAR and TRA. These have involved a high performance liquid chromatography-electrospray ionization-mass spectrometric (LC-ESI-MS) and spectrophotometric methods.39,40 However these methods suffer from disadvantages such as, long analysis time, high costs and requirement for sample pretreatment which is time consuming, making them unsuitable for routine analysis. For these reasons, development of a simple, inexpensive, sensitive and accurate analytical method for simultaneous determination of PAR and TRA would be of considerable value.

Both PAR and TRA are electroactive compounds and can be oxidized electrochemically. To the best of our knowledge, there is only one report in the literature of simultaneous electrochemical studies of PAR and TRA.41 This method used (rather expensive) carbon nanoparticles with surface immobilized phenyl sulfonic acid groups as a modifier for GCE. The method still needs to be improved with respect to its analytical figures of merit. The electrochemical method still has its own advantages; however its improvement is of considerable importance. We have chosen to do this by using different modifiers for glassy carbon electrode.

In this work we outline the use of a multi-walled carbon nanotube modified glassy carbon electrode (MWCNTs/GCE) as a sensor for simultaneous determination of PAR and TRA. Our study has led to the development of a voltammetric method with useful characteristics as simplicity of electrode preparation by the use of lower cost material, low limit of detection (LOD) and wide linear dynamic range (LDR). To confirm its usefulness, the analytical performance of our sensor for determination of PAR and TRA in human serum, human urine and in actual pharmaceutical preparation samples is evaluated.

Experimental

Reagents and solutions

All chemicals were analytical grade and used without further purification. PAR and TRA were obtained from Merck and Fluka chemical companies, respectively. Multi-walled carbon nanotubes (MWCNTs ) ( > 95 wt%, 5-20 nm) were purchased from PlasmaChem GmbH company. Stock standard solutions of 10 mmol L-1 PAR and 10 mmol L-1 TRA were freshly prepared in 0.1 mol L-1 phosphate buffers of pH 7.5. All PAR and TRA solutions were prepared by diluting the stock standard solutions using 0.1 mol L-1 phosphate buffer (pH 7.5). Buffer solutions used in voltammetric studies were prepared as described elsewhere.42 Electrochemical experiments on PAR and TRA were carried out in 0.1 mol L-1 PBS at pH 7.5.

Fresh human serum samples were available from Razi Institute of Vaccine and Serum Company (Tehran, Iran). Serum and urine samples were filtered and diluted 20 times using a 0.1 mol L-1 PBS of pH 7.5, and checked for the determination of the recovery after spiking of PAR and TRA. Ten tablets of ZAFIN® (Laboratorio Saval S.A., Santiago, Chile), labeled as each being of average weight 459.8 mg and containing nominally 325.0 mg of PAR and 37.5 mg of TRA plus some ingredients like corn starch, hypromellose, lactose, magnesium stearate, polyethylene glycol, polysorbate 80 and sodium glycolate, were accurately weighed and powdered in a mortar. A weight equivalent to one tablet content was dissolved in 70 mL of 0.1 mol L-1 PBS (pH 7.5). After 10 min sonication, the solutions were filtered through Whatman No. 42 filter paper (Whatman, Middlesex, UK). The residue was washed three times with 10 mL of the appropriate solvent and the volume was adjusted to 100 mL using the same solvent. Finally, this solution was diluted 250 times using a 0.1 mol L-1 PBS of pH 7.5 and applied for the determination of the recovery in spiking of PAR and TRA compounds.

Instrumentation

All the voltammetric measurements were carried out using our nanotube-modified glassy carbon electrode (MWCNTs/GCE) as the working electrode, Ag/AgCl 3 mol L-1 KCl as the reference electrode and platinum wire as an auxiliary electrode. Differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA) experiments were carried out using an Autolab PGSTAT 30 Potentiostat Galvanostat (EcoChemie, The Netherlands) coupled with a 663 VA stand (Metrohm Switzerland). All potentials given are with respect to the potential of the reference electrode. The pH measurements were performed with a Metrohm 744 pH meter using a combination glass electrode.

Modification of the glassy carbon electrode

The glassy carbon electrode (GCE, 2-mm diameter, Metrohm) was first polished with 0.3 and 0.05 µm aluminum slurry and rinsed thoroughly with triply distilled water. It was then cleaned by sonication for 5 min, first in ethanol and then distilled water, and then dried under a nitrogen gas flow.

Variation of concentration of MWCNTs in DMF solution and volume of the suspension of MWCNTs/DMF for drop coating of the GCE, showed that the best sensitivity for the modified electrode could be obtained when concentration of 1 mg mL-1 and volume of 20 µL of MWCNTs/DMF were used. A stock solution of MWCNTs-DMF was prepared by dispersing 1 mg of MWNTs in 1 mL DMF using ultrasonic bath. Approximately 20 µL of this MWCNTs-DMF solution were coated on to the electrode surface. The electrode were then dried at room temperature to obtain the modified electrode.

This produced MWCNTs/GCE was placed in the electrochemical cell containing 0.1mol L-1 PBS and several cycles in the potential windows of 0.1 to 1 V were performed using the CV method to obtain stable responses.

General procedure

10 mL solutions containing appropriate amounts of PAR and TRA in 0.1 mol L-1 PBS at pH 7.5 were transferred into the voltammetric cell. The voltammograms were recorded by applying positive-going potential from 0 to 0.9 V. The voltammograms showed anodic peaks around 0.32 and 0.62 V corresponding to the PAR and TRA compounds with their heights being proportional to their concentrations in the solutions. Calibration curves were obtained by plotting the anodic peak currents of PAR and TRA against the corresponding concentrations. All experiments were carried out under open circuit conditions.

After each measurement, the MWCNTs/GCE was regenerated by thoroughly washing the electrode with triply distilled water and then 5% sodium hydroxide solution. The electrode was finally rinsed carefully with distilled water to remove all adsorbates from electrode surface and provide a fresh surface for next experiment.

Results and Discussion

Scanning electron microscopy (SEM) analysis of MWCNTs/GCE

SEM was used to observe directly the morphology of MWCNTs/GCE. The SEM images of the MWCNTs/GCE (Figure 1) showed that the GCE surface was mostly covered with homogenous MWCNTs, which were in the form of small bundles or single tubes.


Effect of modification of the electrodes on the effective area

The MWCNTs/GC modified electrode was characterized by electrochemical methods.

K3Fe(CN)6 exhibited a pair of quite reversible redox peaks at a bare GC electrode. At the modified electrode, a pair of higher and reversible redox peaks could still be observed. On the other hand, under the same conditions, the anodic peak of K3Fe(CN)6 at both the GC and MWCNTs/GC electrodes increased in proportion to the square root of the scan rate. It was found that in both cases the electrode process was diffusion controlled. The regression equations for the 4 mmol L-1 K3Fe(CN)6 were:

A reversible system should satisfy the Randles-Sevcik equation:43

According to the ratio of the slopes of the two lines, the apparent area of the MWNTs/GC modified electrode was about 9.8 times greater than that of the GC electrode.

Electrochemical behavior of PAR and TRA on MWCNTs/GCE

Cyclic voltammograms were recorded for 40 µmol L-1 PAR and 100 µmol L-1 TRA at MWCNTs/GCE and are shown in Figure 2. PAR, unlike TRA, showed a reversible oxidation which can be related to electrocatalytic behavior of MWCNTs. The effect of potential scan rate on the oxidation responses of PAR and TRA over the 10-800 mVs-1 range of scan rate was investigated. The linear relationships between the anodic peak currents and scan rates were observed for both in the range of 10-200 mVs-1 as follow:


The linear relationship between peak currents and scan rates suggests that the redox reactions of both the PAR and TRA compounds at MWCNTs/GCE are adsorption-controlled processes.

Differential pulse voltammograms recorded for paracetamol and tramadol at a bare GCE, and a MWCNTs/GCE are shown in Figure 3. Curve a shows the voltammogram of a solution of 140 µmol L-1 of PAR, and 170 µmol L-1 of TRA in PBS (pH 7.5) on a GC electrode. Curve b displays a voltammogram of PAR and TRA under the same conditions as a, on a MWCNTs/GCE electrode. It can be seen very small oxidation peaks for PAR and TRA at GC. The DPVs of PAR and TRA at MWCNTs/GCE (curve b) showed a considerable enhancement of the oxidation peak currents for both the PAR and TRA oxidations. The presence of MWCNTs can increase the electrode surface area and therefore account for the enhancements in the corresponding electrochemical oxidation peak currents observed.


Effects of solution pH

The effect of solution pH on the electrochemical response of the MWCNTs/GCE towards PAR and TRA in the simultaneous determination of 30 µmol L-1 PAR and 100 µmol L-1 TRA was investigated using DPV method. Variations of peak current with respect to pH of the electrolyte in the pH range from 4 to 10 are shown in Figure 4. It can be seen that the anodic peak currents of PAR increase with solution pH until the pH reaches 7. However at higher pHs the PAR oxidation peak current starts to diminish. The oxidation peak current for TRA also increases with pH but only starts to fall down from a pH of 8. A pH value of 7.5, which is close to biological pH value, was chosen as an optimum solution pH for further experiments.


Effect of accumulation time

Figure 5 shows plots of the anodic peak currents, obtained from DPV experiments, against accumulation time for solutions that are 40 µmol L-1 in PAR and 150 µmol L-1 in TRA. Initially, the peak current for TRA increases with accumulation time up to 40 s, but after 40 s of accumulation time, the peak current forms plateaus. For PAR, the corresponding oxidation peak current increases up to 50 s before leveling off. The accumulation time of 50 s was chosen as an optimum time for further experiments.


Linear dynamic range and limit of detection of the method

Regarding the complete resolution of differential voltammetric responses of PAR and TRA, the modified electrode successfully applied for the individual determination of PAR in the presence of TRA (Figure 6A) and individual determination of TRA in the presence of PAR (Figure 6B). The electrochemical responses of simultaneous additions of solutions of PAR and TRA in 0.1 mol L-1 PBS pH 7.5 using MWCNTs/GCE are depicted in Figures 7 and 8. Figure 7 shows differential pulse voltammograms and the corresponding calibration curves obtained for various concentrations of PAR and TRA at MWCNTs/GCE. For PAR, a linear dynamic range from 0.5 µmol L-1 to 210 µmol L-1, with a calibration equation of Ip(µA) = 0.6624c (µmol L-1) + 3.3392 (R2 = 0.9984), and a limit of detection (LOD) of 0.085 µmol L-1 (S/N = 3) were obtained. For TRA, a linear relationship was found over the range of 2 to 300 µmol L-1 with a calibration equation of Ip(µA) = 0.1623c (µmol L-1) + 0.5911 (R2 = 0.9978), and a limit of detection of 0.361 µmol L-1. The characteristics of the calibration curves of PAR and TRA in individual and mixture solutions are presented in Table 1. The investigations showed that these linear ranges were kept in mixture solutions of PAR and TRA, revealing high efficiency of the prepared modified electrode for determinations in pharmaceutical samples of these drugs.




Figure 8

Repeatability and long-term stability of the electrode

The repeatability of the analytical signals were studied and relative standard deviations (RSD) of 0.66 and 0.98% for 70 µmol L-1 PAR and 90 µmol L-1 TRA respectively, in ten consecutive determinations, were obtained.

The proposed modified electrode has a further attraction of good long-term stability. This was tested by measuring the decrease in voltammetric current during repetitive DPV measurements of PAR and TRA solutions with MWCNTs/GCE stored in solution or air for certain period of time. For example, in the determination of 50 µmol L-1 PAR and 150 µmol L-1 TRA in 0.1 mol L-1 PBS (pH 7.5), when the modified electrode was subjected to an experiment every 30 min, after 24 h gave less than 10.8 and 9.1% decrease in the voltammetric currents of PAR and TRA, respectively. When the electrode was stored in the atmosphere for 7 days, the currents response of PAR and TRA reduced less than 12.1 and 10.8%, respectively when the electrode subjected to a solution of the same composition.

Interference studies

The influences of common interfering species in the presence of 50 µmol L-1 PAR and 50 µmol L-1 TRA under optimum conditions were investigated, and the results confirmed that interfering species did not significantly influence the height of the peak currents for PAR and TRA. The tolerance limits (defined as the concentrations which give an error < 10%) for some of the most common interfering agents are shown in Table 2. The data in brackets are concentrations of the interfering species in µmol L-1. They show that the proposed method is free from interferences of the most common interfering agents.

Analytical applications

The applicability of a MWCNTs/GC electrode to the determination of PAR and TRA in human serum, human urine and drug samples was examined. Differential pulse voltammograms were obtained by spiking prepared real solutions with appropriate samples and using MWCNTs/GCE at optimum conditions as described earlier to analyse these. Concentrations were measured by applying the calibration plot. The results are shown in Tables 3 to 5. The values shown in parenthesis in Table 5, were obtained using UV-Vis spectroscopy method as previously reported.61 The recoveries indicate that both the accuracy and repeatability of our proposed method are very good. From above experimental results, it is very clear that this method has great potential for the determination of trace amounts of these compounds in biological systems and pharmaceutical preparations.

A comparison between the analytical characteristics of some reported electrochemical methods for determination of PAR and TRA and the present method is shown in Table 6. It can be seen that our proposed method has both a lower limit of detection and a wider linear dynamic range and has good sensitivity.

Conclusions

In this paper we have introduced a simple sensor based on multi-walled carbon nanotube modified glassy carbon electrode. We have shown that the application of MWCNTs increases anodic peak currents for both paracetamol and tramadol on the electrode surface. The results indicated that the use of MWCNTs/GCEs allows the simultaneous determination of PAR and TRA with good sensitivity and selectivity. The electrode also shows high stability in repetitive experiments. The effects of the potential interferants were studied, and were found to be insignificant for the most common ones. Use of the proposed sensor for the determination of PAR and TRA not only in some pharmaceutical preparations but also in some real samples such as those containing human serum or urine, gave satisfactory results without the necessity of sample pretreatments or time-consuming extractions. The simple fabrication procedure, high speed, reproducibility, high stability, wide linear dynamic range, low limit of detection, high sensitivity, suggest that the proposed sensor is an attractive candidate for practical applications.

Acknowledgments

The authors gratefully acknowledge the research council of Arak University for providing financial support for this work. Thanks to Dr. Alan Happer from Canterbury University in New Zealand for his valuable comments.

Submitted: November 10, 2010

Published online: May 12, 2011

  • 1. Iijima, S.; Nature 1991,354,56.
  • 2. Ajayan, P. M.; Chem. Rev. 1999,99,1787.
  • 3. Tasis, D.; Tagmatarchis, N.; Bianco, A.; Prato, M.; Chem. Rev. 2006,106,1105.
  • 4. Serp, P.; Corrias, M.; Kalck, P.; Appl. Catal., A 2003,253,337.
  • 5. Sweetman, S. C.; Martindale: The Complete Drug Reference, 33rd ed.; Pharmaceutical Press: London, 2002.
  • 6. Martin, F. L.; McLean, A. E.; Drug Chem. Toxicol. 1998,21,477.
  • 7. Prabakar, S. J. R.; Narayanan, S. S.; Talanta 2007,72,1818.
  • 8. Moffat, A. C.; Clark's Isolation and Identification of Drugs, 2nd ed.; The Pharmaceutical Press: London, 1986.
  • 9
    National coorporation of Pharmacies, Sweden (Apoteket AB) Salestatistics 2006.
  • 10. Klotz, U.; Arzneimittelforschung 2003,53,681.
  • 11. Richter, W.; Barth, H.; Flohe, L.; Giertz, H.; Arzneimittelforschung 1985,35,1742.
  • 12. Grond, S.; Sablotzki, A.; Clin. Pharmacokinet. 2004,43,879.
  • 13
    UN convention; Yellow List: List of Narcotic Drugs under International Control, UN convention, United Nations: Vienna, Austria, 2004.
  • 14. Epstein, D. H.; Preston, K. L.; Jasinski, D. R.; Biol. Psychol. 2006,73,90.
  • 15. Scott, L. J.; Perry, C. M.; Drugs 2000,60,139.
  • 16. Karen, M.; Lesley, J. S.; Drugs 2003,63,1079.
  • 17. Kucuk, A.; Kadioglu, Y.; Celebi, F.; J. Chromatogr., B 2005,816,203
  • 18. Zhao, S.; Bai, W.; Yuan, H.; Xiao, D.; Anal. Chim. Acta 2006,559,195.
  • 19. Murillo Pulgarín, J. A.; García Bermejo, L. F.; Anal. Chim. Acta 1996, 33,59.
  • 20. Srivastava, M. K.; Ahmed, S.; Singh, D.; Shukla, I. C.; Analyst 1985,110,735.
  • 21. Bloomfield, M. S.; Talanta 2002,58,1301.
  • 22. Ravisankar, S.; Vasudevan, M.; Gandhimathi, M. M.; Suresh, B.; Talanta 1998,46,1577.
  • 23. Bouhsain, Z.; Garrigues, S.; de la Guardia, M.; Fresenius J. Anal. Chem. 1997,357,973.
  • 24. Vilchez, J. L.; Blanc, R.; Avidad, R.; Navalon, A.; J. Pharm. Biomed. Anal. 1995,13,1119.
  • 25. Easwaramoorthy, D.; Yu, Y. C.; Huang, H. J.; Anal. Chim. Acta 2001,439,95.
  • 26. Zaghloul, I. Y.; Radwan, M. A.; J. Liq. Chromatogr. Relat. Technol. 1997,20,779.
  • 27. Medvedovici, A.; Albu, F.; Farca, A.; David, V.; J. Pharm. Biomed. Anal. 2004,34,67.
  • 28. Nobilis, M.; Kopecky, J.; Kvetina, J.; Chladek, J.; Svoboda, Z.; Vorisek, V.; Perlik, F.; Pour, M.; Kunes, J.; J. Chromatogr., A 2002,949,11.
  • 29. Valle, M.; Pavon, J. M.; Calvo, R.; Campanero, M. A.; Troconiz, I. F.; J. Chromatogr., B: Biomed. Sci. Appl. 1999,724,83.
  • 30. Pospisilova, M.; Polasek, M.; Jokl, V.; J. Pharm. Biomed. Anal. 1998,18,777.
  • 31. Ho, S. T.; Wang, J. J.; Liaw, W. J.; Ho, C. M.; Li, J. H.; J. Chromatogr., B: Biomed. Sci. Appl. 1999,736,89.
  • 32. Tao, Q.; Stone, D. J. Jr.; Borenstein, M. R.; Jean-Bart, V.; Codd, E. E.; Coogan, T. P.; Desai-Krieger, D.; Liao, S.; Raffa, R. B.; J. Chromatogr., B: Biomed. Sci. Appl. 2001,763,165.
  • 33. Gambaro, V.; Benvenuti, C.; Ferrari, L.; Dell Acqua, L.; Fare, F.; Il Farmaco 2003, 58, 947.
  • 34. Moore, C.; Marinetti, L.; Coulter, C.; Crompton, K.; Forensic Sci. Int 2008,176,47.
  • 35. Soetebeer, U. B.; Schierenberg, M. O.; Schulz, H.; Grunefeld, G.; Andresen, P.; Blaschke, G.; J. Chromatogr., B: Biomed. Sci. Appl. 2000,745,271.
  • 36. Venkateshwarlu, K.; Reddy, Y. N.; Srisailam, K.; Rajkumar, V.; Pai, M. G.; Curr. Trends Biotechnol. Pharm. 2008,2,421.
  • 37. Abdellatef, H. E.; J. Pharm. Biomed. Anal. 2002,29,835.
  • 38. Abdellatef, H. E.; El-Henawee, M. M.; El-Sayed, H. M.; Ayad, M. M.; Spectrochim. Acta, Part A 2006,65,1087.
  • 39. Zhu, T.; Ding, L.; Guo, X.; Yang, L.; Wen, A.; Chromatographia 2007,66,171.
  • 40. Toral, M. I.; Rivas, J.; Saldias, M.; Soto, C.; Orellana, S.; J. Chil. Chem. Soc. 2008,53,1543.
  • 41. Ghorbani-Bidkorbeh, F.; Shahrokhian, S.; Mohammadi, A.; Dinarvand, R.; Electrochim. Acta 2010,55,2752.
  • 42. Babaei, A.; Zendehdel, M.; Khalilzadeh, B.; Taheri, A. R.; Colloids Surf., B 2008,66,226.
  • 43. Bard, A. J.; Faulkner, L. R.; Electrochemical Methods, Fundamentals and Applications, Wiley: New York, 1980.
  • 44. Nattakarn, W.; Orawon, C.; J. Pharm. Biomed. Anal. 2002,28,841.
  • 45. Masawat, P.; Liawruangrath, S.; Vaneesorn, Y.; Liawruangrath, B.; Talanta 2002,58,1221.
  • 46. Vieira, I. C.; Lupetti, K. O.; Fatibello-Filho, O.; Quim. Nova 2003,26,39.
  • 47. Boopathi, M.; Won, M. S.; Shim, Y. B.; Anal. Chim. Acta 2004,512,191.
  • 48. Gomez-Caballero, A.; Goicolea, M. A.; Barrio, R. J.; Analyst 2005,130,1012.
  • 49. Wang, C.; Li, C.; Wang, F.; Wang, C.; Microchim. Acta 2006,155,365.
  • 50. Goyal, R. N.; Singh, S. P.; Electrochim. Acta 2006,51,3008.
  • 51. Messina, G. A.; De Vito, I. E.; Raba, J.; Anal. Chim. Acta 2006,559,152.
  • 52. Silva, M. L. S.; Garcia, M. B. Q.; Lima, J. L. F. C.; Barrado, E.; Anal. Chim. Acta 2006,573,383.
  • 53. Sun, D.; Zhang, H.; Microchim. Acta 2007,158,131.
  • 54, Wang, S. F.; Xie, F.; Hu, R. F.; Sens. Actuators, B 2007,123,495.
  • 55. Felix, F. S.; Brett, C. M. A.; Angnes, L.; J. Pharm. Biomed. Anal. 2007,43,1622.
  • 56. Sima, V.; Cristea, C.; Lapadus, F.; Marian, I. O.; Marian, A.; Sandulescu, R.; J. Pharm. Biomed. Anal. 2008,48,1195.
  • 57. Ashok Kumar, S.; Chun-Fang, T.; Shen-Ming, C.; Talanta 2008,76,997.
  • 58. Lourencao, B. C.; Medeiros, R. A.; Rocha-Filho, R. C.; Mazo, L. H.; Fatibello-Filho, O.; Talanta 2009,78,748.
  • 59. Garrido, E. M. P. J.; Garrido, J. M. P. J.; Borges, F.; J. Pharm. Biomed. Anal. 2003,32,975.
  • 60. Maria, S.; Quintino, M.; Koiti, A.; Henrique, E.; Lucio, A.; Electroanalysis 2002,14,1629.
  • 61. Toral, M. I.; Rivas, J.; Saldias, M.; Soto, C.; Orellana, S.; J. Chil. Chem. Soc. 2008,53,1543.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      04 Aug 2011
    • Date of issue
      Aug 2011

    History

    • Accepted
      12 May 2011
    • Received
      10 Nov 2010
    Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
    E-mail: office@jbcs.sbq.org.br