Acessibilidade / Reportar erro

An Ion-Pair Reagent Incorporated Polystyrene Nanofiber Applied to Solid Phase Extraction of 5-Hydroxytryptamine in Human Plasma

Abstract

Polystyrene (PS) nanofibers incorporated with ion-pair (IP) reagent, e.g., sodium dodecyl sulfonate (SDSn), were developed as functional adsorbents for the solid-phase extraction (SPE) of ionic neurotransmitter such as 5-hydroxytryptamine (5-HT), prior to the determination by high performance liquid chromatography-fluorescence detection (HPLC-FLD). A comprehensive study was initiated to optimize the preconcentration step by exploring the main factors that affect the extraction/preconcentration efficiency of 5-HT, such as the composition of nanofibers, eluent and its volume, amount of adsorbent, pH and ionic strength. The validity of this method was investigated and optimal analytical performance was achieved including a wide dynamic range of 0.50-200 ng mL-1, detection limits of 0.50 ng mL–1 and precision (as RSD%) lower than 4% for both intra-day and inter-day assays. This method was then applied to the determination of 5-HT in human plasma with satisfactory results.

solid phase extraction; ion-pair reagent incorporated nanofiber; 5-hydroxytryptamine; human plasma


Introduction

Solid-phase extraction (SPE) is regarded as one of the most popular sample preparation methods. It has been used extensively to extract, purify and concentrate analytes from complex matrices, such as environmental and biological samples, attributed to its high preconcentration factors, low consumption of organic solvents, simplicity, relatively high selectivity and the ease of automation and operation.11 Zhao, X. L.; Li, J. D.; Shi, Y. L.; Cai, Y. Q.; Mou, S. F.; Jiang, G. B.; J. Chromatogr. A 2007, 1154, 52.

Electrospinning, an electrostatic fiber fabrication technique, can be used to spin ultra-thin fibers from polymers. The nanoscale fibers are generated by the application of strong electric field, which imposes a uniaxial stretching of a viscoelastic jet derived from the polymer solution to continuously reduce the diameter and leads to formatting nanofibres. It is a simple and cost-effectiveness technique for preparation of nanofibers.22 Alireza, V.; Samad, M. F.; IET Nanobiotechnol. 2014, 8, 83. The ultra-thin fibers produced by this process offer various advantages like high surface area to volume ratio, tunable porosity and the ability to manipulate nanofiber composition in order to get desired properties and function. Various applications have been reported, such as heavy metal removal, drug loading and release, chronic wound care.33 Yunpeng, H.; Yue-E, M.; Tianxi, L.; J. Appl. Polym. Sci. 2014, 131, 40864.

4 Goonoo, N.; Bhaw-luximon, A.; Jhurry, D.; J. Biomed. Nanotechnol. 2014, 10, 2173.
-55 Martina, A.; Sally, L. M.; Peter, K.; Macromol. Biosci. 2014, 14, 772.

Electrospun nanofibers were employed as adsorbent for SPE to extract and concentrate target analytes from a complex matrix, due to its pronounced micro and nano characteristics such as high surface area integrated with porous structure, and fiber diameter at nano range. Solid phase micro-extraction fibers are generated by electrospinning SU-8 (an epoxy-based negative photoresist), onto stainless-steel wires, which has been successfully used for the extraction of both nonpolar and polar compounds.66 Zewe, J. W.; Steach, J. K.; Olesik, S. V.; Anal. Chem. 2010, 82, 5341. An μ-SPE device, employing electrospun polypyrrole-polyamide nanofibers sheet as the extracting medium, has been applied to extract trace amounts of malathion from aqueous samples.77 Bagheri, H.; Aghakhani, A.; Akbari, M.; Ayazi, Z.; Anal. Bioanal. Chem. 2011, 400, 3607. Moreover, previously, our group has reported a packed-fiber solid-phase extraction (PFSPE), in which electrospun polystyrene (PS) nanofibers are packed into a small cartridge to extract drugs, hormone and vitamins in biological matrices,88 Kang, X. J.; Chen, L. Q.; Zhang, Y. Y.; Liu, W.; Gu, Z. Z.; J.Sep. Sci. 2008, 31, 3272.

9 Chen, L. Q.; Kang, X. J.; Sun, J.; Deng, J. J.; Gu, Z. Z.; Lu, Z. H.; J. Sep. Sci. 2010, 33, 2369.
-1010 Liu, Z. Y.; Kang, X. J.; Fang, F.; Microchim. Acta 2010, 168, 59. and even trace pollutants in environmental samples.1111 Qi, D. J.; Kang, X. J.; Chen, L. Q.; Zhang, Y. Y.; Wei, H. M.; Gu, Z. Z.; Anal. Bioanal. Chem. 2008, 390, 929. However, most of the published work has concentrated on the extraction of nonpolar or weakly polar compounds; for highly polar and hydrophilic compounds, the study of SPE were limited due to their pronounced difficulty in isolating and preconcentraing. Therefore, this inspires us and also leaves the opportunity to develop novel materials for the extraction of polar compounds by PFSPE.

One solution to the problem of adsorbing polar molecules is to introduce polar components into the solid phase, thus favoring the polar interaction between sorbent and analytes, and also enhancing the recoveries. Using hydrophilic sorbents and ion-pair (IP) reagent have been long known to alter selectivity and increase retention of highly polar compounds on solid phase.1212 Marce, R. M.; Borrull, F.; J. Chromatogr. A 2008, 885, 273. In the past, hydrophilic polymeric and ion-exchange sorbents were prepared by either copolymerizing monomers with desirable functional groups or by chemical modification with appropriate reagent, involving complicated multi-step process. In contrast, electrospinning can incorporate IP reagents directly into the nanofibers matrices, via a single step solution pre-mixing method. This, in fact, can be much convenient to enhance the overall performance of nanofibers for enrichment of polar target compounds. Basing on this hypothesis, a novel PS nanofiber integrated with counter ions was generated by incorporation of anionic surfactants (sodium dodecyl sulfonate, SDSn) into the spinning solution of PS polymer for the first time.

5-hydroxytryptamine (5-HT or serotonin) is a monoamine neurotransmitter widely distributed in biological systems and plays an important role in a number of pharmacological, physical and fundamental biological processes.1313 Goyal, R. N.; Gupta, V. K.; Oyama, M.; Bachheti, N.; Talanta 2007, 72, 976.,1414 Carson, M. C.; J. Chromatogr. A 2000, 885, 343. Consequently, to quantitatively analyze 5-HT is the key step for its extensive studies. However, the detection method of 5-HT was limited because of its very low concentration in human plasma and the presence of many native interfering. Therefore, it is necessary to pretreat samples such as clean-up and enrichment prior to analysis.

For this purpose, a solid phase extraction method, employing nanofibers adsorbent containing IP reagent, has been developed within our research group. 5-HT was selected as the model analyte to demonstrate the potential applications and advantages of this method. A special handheld device has been invented for biological sample pretreatment by PFSPE, allowing fine adjustment and optimization of factors influencing the extraction efficiency, such as the composition of nanofibers, eluent and its volume, amount of adsorbent, pH and salts. With sample pretreatment in place, the extraction method was further validated by successful determination of 5-HT level in human plasma samples.

Experimental

Chemicals and reagents

5-HT was purchased from Sigma-Aldrich (Shanghai, China), liquid chromatography grade methanol was obtained from Shandong Yuwang Chemical (Shangdong, China). Potassium dihydrogen phosphate, sodium lauryl sulfate (SLS), sodium heptane sulfonate, sodium hexadecyl sulfonate, phosphoric acid were purchased from Xilong Chemical Co., Ltd and were of analytical reagent grade. Ethylene diamine tetraacetic acid (EDTA), trichloroacetic acid (TCA), sodium dodecyl sulfonate (SDSn), sodium dodecyl benzene sulfonate (SDBS) were purchased from Sinopharm Chemical Reagent Co.,Ltd and were also of analytical reagent grade. Double distilled water was used throughout the experiments. PS (Mw = 185,000), tetrahydrofuran (THF) and dimethylformamide (DMF) of analytical grade were purchased from Shanghai Chemical Agents Institute (Shanghai, China). The pipette tip (200 μL) was from Yonghua glasswork (Haimen, Jiangsu, China). Heparinized spiked human plasma was provided by Nanjing Blood Donor Service (Nanjing, China) and was stored at -20 °C. Blank plasma sample was obtained from the irradiation under ultraviolet light (6 W, 365 nm) for 2 h.1515 Masanori, Y.; Yutaka, K.; Zenzo, T.; Takao, K.; Chem. Pharm. Bull. 1977, 25, 75. This research had been approved by the Ethic Committee of Southeast University, Nanjing, China.

Instrumentation

The nanofibers were fabricated with electrospinning at the voltage of 17.5 kV supplied by a Dongwen high-voltage generator (DW-P403-1AC, Tianjin, China). The flow rate of the syringe was controlled by a SLGO syringe pump (TCI-I, Beijing, China). The morphology images of SDSn incorporated PS nanofibers were obtained by using a Hitachi S-3000N scanning electron microscope (SEM, Tokyo, Japan), at an acceleration voltage of 10 kV. ImageJ software 1.48v was used for the fiber diameter calculation. Fiber pore diameter, pore volume, and surface area were analysised by Micromeritics analyzer (ASAP 2020, Norcross, U.S.A).

High performance liquid chromatography (HPLC) was carried out on a Shimadzu LC serious system (Tokyo, Japan) equipped with a LC-20A pump, a Shimadzu RF-10AXL fluorescence detector and a HPLC software package. The separation was performed using a Shimadzu C18 column (150 mm × 4.6 mm, 5 μm) from Dikma (Dikma Techologies, Beijing, China), which was kept in an oven at 30 °C. The mobile phase was composed of 50 mmol L–1 phosphoric acid buffer solution (pH 4.5), 0.1 mmol L–1 EDTA and 5.8% (v/v) methanol at a flow rate of 1.0 mL min–1. The injection volume was 20 μL. The wavelengths of excitation and emission were 280 nm and 340 nm, respectively.

Fabrication of IP reagents incorporated PS nanofibers and PFSPE handheld device

IP incorporated PS nanofibers were prepared by electrospinning as follow: 10% m/v PS solution was prepared by dissolving an appropriate amount of PS into a mixture of DMF and THF (4/6, v/v), with addition of 5% m/v IP reagents (SDSn, SLS, SDBS, sodium heptane sulfonate and sodium hexadecyl sulfonate). This solution was loaded into a glass syringe (5 mL). The glass syringe was fitted to a steel needle with a tip diameter of 0.5 mm and a flat tip, which was connected to the anode. The aluminum foil collecting equipment was connected to the cathode. A voltage of 17.5 kV was supplied by a high‑voltage generator. The distance between the needle tip and the collector was 20 cm. The feeding rate of the precursor solution was fixed at 2.0 mL h–1. The morphology and size of nanofibers were examined using SEM.

The PFSPE columns were developed according to the procedure described in a previous article.1111 Qi, D. J.; Kang, X. J.; Chen, L. Q.; Zhang, Y. Y.; Wei, H. M.; Gu, Z. Z.; Anal. Bioanal. Chem. 2008, 390, 929. 3 mg of SDSn incorporated PS nanofibers were divided into four or five parts, and packed into the tip end of the solid-phase column. Then, the column was inserted into the handheld device as plotted in Figure 1. The SPE column could be inserted into the tubular column cartridge and fixed by holddown groove and bottom ferrule. Pushing the pressure bar, the sample solution could be pushed through the sorbent by the pressure of air forced by a gas tight plastic syringe (pressurizer). A steady flow speed could be maintained by adjusting bayonet lock and the slot on the pressure bar. Such design enabled a massive saving on the manual-work required for biological sample preparation, such as plasma, saliva and urine, which is usually volume-limited and highly viscous.

Figure 1
Schematic representation of handheld solid-phase extraction device. (a) PFSPE column, (b) handheld device and (c) pressure subassembly

Recommend SPE procedure

The procedure recommended for the nanofiber solid phase extraction was as follow: plasma sample (500 μL) was mixed with 60 μL (30%, m/v) of TCA solution by vortexing for 30 s, then centrifuged at 12,750 × g for 5 min. The supernatant was separated and adjusted to pH 6.0 with 50 μL of sodium hydroxide (0.3 mol L–1), before injected through the nanofiber column by the handheld device carefully controlled in a drop wise manner (about 0.5 mL min–1). The column was preconditioned with 100 μL of methanol and 200 μL of water. The target analyte retained on the PS-SDSn nanofibers was eluted with 100 μL of methanol and 1 mol L–1 ammonium formate (1/1, v/v) into the collecting tubes, then 20 μL of the eluent was injected into chromatographic system.

Conventional ion-pair solid-phase extraction (IP SPE)

PS nanofibers and the PFSPE columns were fabricated as described in a previous paper.1616 Kang, X. J.; Pan, C.; Xu, X.; Yao, Y. F.; Wang, Y. Y.; Qi, D. J.; Gu, Z. Z.; Anal. Chim. Acta 2007, 587, 75. The PFSPE columns with 3 mg of PS nanofibers were activated by 100 μL of methanol and 100 μL of water, followed with 100 μL of 0.05 mol L–1 SDSn solution. Meanwhile, 100 μL of 0.05 mol L–1 SDSn solution was added to the 500 μL of prepared human plasma sample before loading to the preconditioned PFSPE columns. The flow rate was controlled in a drop wise manner (about 0.5 mL min–1) and 5-HT was eluted with 100 μL of methanol.

Results and Discussion

Fabrication of SDSn incorporated PS nanofibers

The SEM images of SDSn incorporated PS nanofibers and PS nanofibers are shown in Figure 2. The average fiber diameter has been calculated by use of free and open source ImageJ software based on the images of 20 nanofibers shown in Figure 2. The result was that the diameter of the PS nanofibers was 381 ± 94 nm (n = 20) and SDSn incorporated PS nanofibers was 232 ± 63 nm (n = 20). The pore diameter, pore volume, and surface area of PS nanofibers and SDSn incorporated PS nanofibers were respectively 3.25 nm, 0.02 cm3 g-1, 9.65 m2 g-1 and 5.04 nm, 0.02 cm3 g-1, 19.52 m2 g-1.

Figure 2
SEM images of (A) SDSn incorporated PS nanofibers and (B) PS nanofibers.

The performance of IP reagents incorporated nanofibers as sorbents for SPE strongly relied on the composition of nanofibers. In this study, IP reagents of different hydrophilic groups, hydrocarbon length, and the concentration of them were investigated to elucidate interaction between 5-HT and the solid phase. The effect of nanofiber composition was investigated by using spiked plasma sample at the 5-HT concentrations of 5, 50 and 200 ng mL–1.

Three IP reagents (SDSn, SLS, and SDBS) with different hydrophilic group, i.e., sulfonic acid, benzene sulfonic acid, and ester sulfate group were tested to seek optimal performance by adding an equal amount (0.18 mol L–1) of them into the PS solution to prepare the nanofibers. As shown in Figure 3a, the extract recoveries showed no difference among three nanofibers when the spiked 5-HT concentration was 5 ng mL–1, but PS-SDSn nanofibers performed better than the other two when the spiked 5-HT concentration was 50 and 200 ng mL–1, thus, SDSn was selected as the modifier to prepare IP reagents incorporated nanofibers by electrospinning.

Figure 3
Effect of composition of IP reagent incorporated nanofibers on the recoveries of 5-HT. (a) Effect of IP reagent with different hydrophilic group; (b) effect of hydrocarbon chain length of sulfonate and (c) effect of SDSn concentration.

Besides, the effect of hydrocarbon chain length of the sulfonate on the extraction was studied. Sodium heptane sulfonate, sodium dodecyl sulfonate, and sodium hexadecyl sulfonate were used to prepare nanofibers from the electrospinning solution containing 0.18 mol L–1 of each sulfonate. The extraction efficiency of 5-HT was tested and PS-SDSn nanofibers performed better than others, as presented in Figure 3b.

The effect of SDSn concentration on extraction efficiency was also investigated. The concentration of SDSn was tested form 1% to 10% (m/v). As seen in Figure 3c, the extraction efficiency of 5-HT increased when the percents (m/v) of SDSn was in the range of 1% to 5%, while in the range of 5% to 10%, the extraction efficiency decreased. Therefore, 5% was chosen as the optimum concentration of SDSn.

Optimization of the SPE procedure

In order to achieve high extraction efficiency for the target analyte, several important parameters, such as amount of adsorbent, eluent composition and its volume, pH and salt concentration in sample solution should be considered cautiously. A spiked plasma sample containing 50 ng mL–1 of 5-HT was used as model sample in the optimized experiments.

Effect of packed nanofibers amount

The amount of nanofibers plays an important role in the solid-phase extraction process. It was found that extraction efficiency increased with the increasing fiber quantity up to 3.0 mg of packing quantity, and over 3.0 mg variations of 5-HT recoveries were not remarkable. Therefore, 3 mg was selected as the appropriate amount to achieve effective pretreatment.

Effect of eluent

The effect of eluent and its volume on extraction efficiency were tested for eluting 5-HT by using methanol and acetonitrile as solvent. It was found that methanol performed better than acetonitrile. This may be attributed to the difference in dielectric constant for methanol (33.7) and acetonitrile (38.8). Compared with acetonitrile, methanol has a lower dielectric constant; the molecules of this solvent exert a weaker ability to produce solvation to stabilize cations like ammonium ions in the eluent, which promotes the replacement of 5-HT by formation of ion-pair between ammonium and SDSn ions, and so methanol had the higher efficiency as the eluting solvent for 5-HT. To ensure maximum elution of 5-HT from the PFSPE columns, an eluent experiment was carried out by changing the volume of methanol from 50 to 200 μL. The results indicated that the recovery of 5-HT increased with the increasing of the methanol volume from 50 to 100 μL. Once above 100 μL, the recovery reached a plateau. Consequently, 100 μL of methanol was chosen as the eluent.

Effect of pH

The pH of samples solution could also be an important factor in SPE enrichment procedure because it affected the degree of ionization of the 5-HT and the ability to form IP with counter ion(s). The effect of pH on the extraction of 5-HT was examined in the range of pH 3.0 to 10.0. The maximum extraction efficiency of 5-HT was achieved at pH 6.0, while the lowest was obtained at pH 3.0 or 10.0. This was attributed to the alkaline nature of 5-HT (pKa 9.8)1717 Huang, Y. F.; Chiang, C. K.; Lin, Y. W.; Liu, K.; Hu, C. C.; Bair, M. J.; Chang, H. T.; Electrophoresis 2008, 29, 1942. and the pka of alkyl sulfonates. When sample solution is at weak acidic pH, 5-HT can combine with protons to form cation, and it mainly exists in its unionized form or even in negative ion form at basic pH, which could not be attracted by conter ions. The pKa of alkyl sulfonates ranges in values between 2.0 and 3.0, depending on the substituents on the alkyl group.1818 Jingming, W.; Hian, L. L.; Anal. Chem. 2006, 78, 7292. Thus, at pH less than 3, SDSn exists mainly in the neutral form. The IP complex between SDSn molecular and positive charged 5-HT is hardly formed. When the pH is higher than 3.0, SDSn hydrolyzes to form sulfonate, which interacts with 5-HT by electrostatic force. Thus, the pH of sample solution was adjusted to pH 6.0.

Effect of salt concentration

The effect of salt concentration on the extraction efficiency was tested with sodium chloride ranging from 0 to 500 mmol L–1. Results shown in Figure 4 clearly suggested that the addition of sodium chloride decreased retention of 5-HT on PS-SDSn nanofibers. Generally, addition of NaCl to sample solution increases the ionic strength as well as changes the physical properties of Nernst diffusion layer.1919 Long, H. Y.; Zhang, J. C.; Chin. J. Integr. Tradit. West. Med. (Chin. Ed.) 2012, 32, 926. It is well known that adding salt to solution would decrease the solubility of organic compounds in water phase,1010 Liu, Z. Y.; Kang, X. J.; Fang, F.; Microchim. Acta 2010, 168, 59. resulting in an increase in the amount of the analytes extracted by the nanofibers. However, IP incorporated nanofibers adsorbing 5-HT primarily was based on electrostatic interaction, thus causing the competition mechanism. This means that ions with the same charge compete with the target analytes, thereby decreasing the extent of IP formation and the extraction efficiency.1414 Carson, M. C.; J. Chromatogr. A 2000, 885, 343. The addition of NaCl also reduces mass transfer by changing the Nernst diffusion layer, probably leading to the decreased rate of the formation of the ion pairs,1818 Jingming, W.; Hian, L. L.; Anal. Chem. 2006, 78, 7292. and therefore the decreased extraction efficiency. Consequently, salt should be eliminated from the system.

Figure 4
Effect of salt addition to the sample. Nanofibers: 3 mg; SDSn concentration: 5% (m/v); 5-HT concentration: 50 ng mL–1; sample solution volume: 500 μL (pH 6.0); sample flow rate: 0.5 mL min–1; eluent: methanol and 1 mol L–1 ammonium formate (1/1, v/v). Error bars illustrate the relative standard deviation from six replicates determinations.

Reusability of SDSn incorporated PS nanofibers

Commonly SPE cartridges are for single-use only. Considering the adsorbing site was introduced onto the fiber surface by incorporated electrospinning rather than chemically synthesis, the potential to reuse SDSn incorporated nanofibers should be investigated to indicate the stability of adsorbing sites existed in the fibers. After per circle of samples treatment as shown in recommend SPE procedure section, 100 μL of methanol were employed to wash the column followed by 200 μL of water to eliminate any possible residue of 5-HT. The column was then reused to investigate the recovery of 5-HT. The results are shown in Figure 5. It is clear that the variation of recoveries were not obvious for the former four times, however, the recoveries of 5-HT were reduced when the column was reused for the fifth time. Therefore, these adsorbing sites were stable enough to support multiple uses up to 4 times.

Figure 5
Reusability of SDSn incorporated nanofibers. Nanofibers: 3 mg; SDSn concentration: 5% (m/v); sample solution volume: 500 μL (pH 6.0); sample flow rate: 0.5 mL min–1; eluent: methanol and 1 mol L–1 ammonium formate (1/1, v/v). Error bars indicate the relative standard deviation from six replicates determinations.

Reproducibility, linearity, and sensitivity

Quantitative analysis using nanofiber-packed SPE was evaluated by determination of 5-HT in spiked plasma sample under optimized conditions. The calibration curves, prepared on six consecutive days, showed to be linear in the concentration range of 0.50-200 ng mL–1 (with r2 value of 0.999). The detection limit, calculated at a signal-to-noise ratio of 3 (S/N = 3), was 0.5 ng mL–1. The precision and accuracy of the method were determined by consecutively analyzing six replicates of spiked plasma at the concentrations of 5, 50 and 200 ng mL–1 as shown in Table 1. The average coefficients of variation (RSD / %) of intra-day and inter-day assays were found to be below 4%. The average recovery at 5, 50, 200 ng mL–1 for 5-HT in spiked plasma samples was 105.2%, 97.2% and 99.8%, respectively (n = 6).

Table.1
The intra- and inter-day validation method for the determination of 5-HT in human plasma

Comparison with conventional IP SPE

In this section, the comparative studies were performed between the recommended SPE procedure and conventional IP SPE, in terms of extraction recovery, reproducibility and sensitivity. The comparisons were investigated by using spiked plasma sample at 5-HT concentrations of 5, 50 and 200 ng mL–1. The results were summarized in Table 2. Compared with IP SPE, SPE with SDSn incorporated nanofibers showed higher recoveries and low detection limit. Another advantage of the new method was the fact that no IP reagent was added into the sample, which would be preferable for mass spectrometry analysis.

Table 2
Comparison of PFSPE with IP SPE

Application

To evaluate the applicability of the developed method in real clinical samples (Figure 6), 12 human plasma samples from 6 Tourette children before and after treatment were prepared and analyzed.1919 Long, H. Y.; Zhang, J. C.; Chin. J. Integr. Tradit. West. Med. (Chin. Ed.) 2012, 32, 926. Under the optimized conditions, 500 μL of each sample was extracted by the SDSn incorporated nanofibers. The results revealed that the plasma concentration of 5-HT was decreased in most children after treatment (Figure 7).

Figure 6
HPLC-FLD chromatograms. (a) 200 ng mL–1 5-HT standard solution; (b) separation of human plasma sample without nanofiber-packed solid phase extraction; (c) extraction of 500 μL of human plasma sample with 3 mg of SDSn incorporated nanofibers. The mobile phases were composed of 50 mmol L–1 phosphoric acid buffer solution (pH 4.5), 0.1 mmol L–1 EDTA and 5.8% (v/v) methanol, which was used at a flow rate of 1.0 mL min–1. The wavelengths of excitation and emission were 280 nm and 340 nm and injection volume was 20 μL. Other conditions were as stated in recommend SPE procedure.
Figure 7
The change of concentration of 5-HT in Tourette children's plasma.

Conclusion

A new functional SPE adsorbent based on IP reagent incorporated PS nanofibers was prepared and successfully applied to the extraction and preconcentration of 5-HT in human plasma samples. Several factors affecting the PFSPE procedure including the composition of nanofibers, eluent compostion and its volume, amount of adsorbent, pH and salt concentration were optimized systematically. The LOD, recovery, and precision of proposed method meet the requirements of 5-HT detection. Thus, an accurate, simple, and sensitive method based on HPLC‑FLD was developed for the determination of 5-HT in human plasma, which can be used in physiological and psychological studies.

Acknowledgments

This work was supported by the National Basic Research Program (973 Program No. 2012CB933302), the National Natural Science Foundation of China (No. 81172720 and No. 21307086). Authors thank Dr Hongyan Long from Nanjing Municipal Hospital of Chinese Medicine for kindly providing clinical plasma samples.

References

  • 1
    Zhao, X. L.; Li, J. D.; Shi, Y. L.; Cai, Y. Q.; Mou, S. F.; Jiang, G. B.; J. Chromatogr. A 2007, 1154, 52.
  • 2
    Alireza, V.; Samad, M. F.; IET Nanobiotechnol. 2014, 8, 83.
  • 3
    Yunpeng, H.; Yue-E, M.; Tianxi, L.; J. Appl. Polym. Sci. 2014, 131, 40864.
  • 4
    Goonoo, N.; Bhaw-luximon, A.; Jhurry, D.; J. Biomed. Nanotechnol. 2014, 10, 2173.
  • 5
    Martina, A.; Sally, L. M.; Peter, K.; Macromol. Biosci. 2014, 14, 772.
  • 6
    Zewe, J. W.; Steach, J. K.; Olesik, S. V.; Anal. Chem. 2010, 82, 5341.
  • 7
    Bagheri, H.; Aghakhani, A.; Akbari, M.; Ayazi, Z.; Anal. Bioanal. Chem. 2011, 400, 3607.
  • 8
    Kang, X. J.; Chen, L. Q.; Zhang, Y. Y.; Liu, W.; Gu, Z. Z.; J.Sep. Sci 2008, 31, 3272.
  • 9
    Chen, L. Q.; Kang, X. J.; Sun, J.; Deng, J. J.; Gu, Z. Z.; Lu, Z. H.; J. Sep. Sci 2010, 33, 2369.
  • 10
    Liu, Z. Y.; Kang, X. J.; Fang, F.; Microchim. Acta 2010, 168, 59.
  • 11
    Qi, D. J.; Kang, X. J.; Chen, L. Q.; Zhang, Y. Y.; Wei, H. M.; Gu, Z. Z.; Anal. Bioanal. Chem 2008, 390, 929.
  • 12
    Marce, R. M.; Borrull, F.; J. Chromatogr. A 2008, 885, 273.
  • 13
    Goyal, R. N.; Gupta, V. K.; Oyama, M.; Bachheti, N.; Talanta 2007, 72, 976.
  • 14
    Carson, M. C.; J. Chromatogr. A 2000, 885, 343.
  • 15
    Masanori, Y.; Yutaka, K.; Zenzo, T.; Takao, K.; Chem. Pharm. Bull. 1977, 25, 75.
  • 16
    Kang, X. J.; Pan, C.; Xu, X.; Yao, Y. F.; Wang, Y. Y.; Qi, D. J.; Gu, Z. Z.; Anal. Chim. Acta 2007, 587, 75.
  • 17
    Huang, Y. F.; Chiang, C. K.; Lin, Y. W.; Liu, K.; Hu, C. C.; Bair, M. J.; Chang, H. T.; Electrophoresis 2008, 29, 1942.
  • 18
    Jingming, W.; Hian, L. L.; Anal. Chem. 2006, 78, 7292.
  • 19
    Long, H. Y.; Zhang, J. C.; Chin. J. Integr. Tradit. West. Med. (Chin. Ed.) 2012, 32, 926.

Publication Dates

  • Publication in this collection
    Mar 2015

History

  • Received
    22 July 2014
  • Accepted
    23 Jan 2015
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br