Trace Element Analysis, Model-Based Clustering and Flushing to Prevent Drinking Water Contamination in Public Schools

Abstract

Drinking water samples taken from cafeteria sinks and water fountains in each of the 76 schools in the Winston-Salem/Forsyth County Schools (WSFCS) district (North Carolina, United States) were analyzed by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) to determine As, Cd, Cr, Cu, Pb, Sb, Se and Tl. All samples from currently active schools tested below the maximum contaminant level (MCL) set for each element. Model-based clustering was employed to identify schools more prone to drinking water contamination. This multivariate approach may be used in a prevention program that can be tailored to specific school districts, with each school tested at a frequency compatible with its contamination risk level. Water flow stagnation during the summer break results in higher elemental concentrations in school drinking water, but a simple 5-60 min flushing procedure significantly reduces the contamination levels.

Keywords:
drinking water contamination; ICP-MS; multivariate analysis; water flow stagnation; preventive flushing


Introduction

In recent years, there have been calls for changes in legislation regarding the mandatory testing of drinking water for copper (Cu) and lead (Pb) in schools in the United States.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016.

2 Lambrinidou, Y.; Triantafyllidou, S.; Edwards, M.; New Solutions: J. Environ. Occup. Health Policy 2010, 20, 25.
-33 Katner, A.; Pieper, K. J.; Lambrinidou, Y.; Brown, K.; Hu, C.-Y.; Mielke, H. W.; Edwards, M. A.; Environ. Justice 2016, 9, 109. Within the state of North Carolina, the State House Legislature introduced legislation in 201644 General Assembly of North Carolina; Schools/CC Facilities - Test Water for Lead, House Bill 1074; North Carolina General Assembly: Raleigh, 2016. requiring drinking water testing and monitoring for Pb at elementary schools and day care facilities built before 1987. Current United States legislation only requires mandatory testing in public schools that are also regulated as a public water supplier. However, approximately 89-92% of all schools in the country fall outside of this category, and testing is only done on a volunteer basis.22 Lambrinidou, Y.; Triantafyllidou, S.; Edwards, M.; New Solutions: J. Environ. Occup. Health Policy 2010, 20, 25.

Monitoring of drinking water for Cu and Pb falls under the mandates established by the Lead and Copper Rule (LCR) and its revisions.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016. The Environmental Protection Agency (EPA) has set forth plans to revise the LCR and address concerns and weaknesses within the legislation such as the fact that there are no enforceable health-based standards. Issues associated with adverse corrosive control methods, inappropriate sampling or sampling processing, delay in action, lack of clarity in what determines compliance, as well as partial lead service line replacements (PLSLR) and potential spikes in Pb concentrations in water as a result of PLSLRs are also being evaluated.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016.,33 Katner, A.; Pieper, K. J.; Lambrinidou, Y.; Brown, K.; Hu, C.-Y.; Mielke, H. W.; Edwards, M. A.; Environ. Justice 2016, 9, 109. In this context, the EPA released a white paper in 2016 advocating for the revision of the LCR with the following key goals outlined: further reduce exposure to Pb in drinking water, set clear enforceable requirements, and improve transparency, environmental justice and children's health.

In addition to the action levels (AL) set for Cu and Pb (1,300 and 15 µg L-1, respectively), the EPA has also established maximum contaminant levels (MCL) for As, Cd, Cr, Cu, Pb, Sb, Se and Tl.55 United States Environmental Protection Agency (US EPA); National Primary Drinking Water Standards; US EPA, Office of Water: Washington, D.C., 2009. The potential health deterrents of As and Pb on neurological development of children is well documented and studied.66 Rosado, J. L.; Ronquillo, D.; Kordas, K.; Rojas, O.; Alatorre, J.; Lopez, P.; Garcia-Vargas, G.; Caamaño, M. C.; Cebrián, M. E.; Stoltzfus, R. J.; Environ. Health Perspect. 2007, 115, 1371.

7 Tsai, S.-Y.; Chou, H.-Y.; The, H.-W.; Chen, C.-M.; Chen, C.-J.; NeuroToxicology 2003, 24, 747.

8 Rodríguez-Barranco, M.; Lacasaña, M.; Aguilar-Garduño, C.; Alguacil, J.; Gil, F.; González-Alzaga, B.; Rojas-García, A.; Sci. Total Environ. 2013, 454-455, 562.
-99 Council on Environmental Health; Pediatrics 2016, 138, e20161493. For Cd, Cr, Cu, Se and Tl, the potential negative health effects of long-term exposure are also recognized by the EPA and the World Health Organization (WHO), with critical concentrations ranging from 2 µg L-1 (Tl) to 1,300 µg L-1 (Cu).55 United States Environmental Protection Agency (US EPA); National Primary Drinking Water Standards; US EPA, Office of Water: Washington, D.C., 2009.,1010 World Health Organization (WHO); Guidelines for Drinking-Water Quality - Recommendations, vol. 1, 3rd ed.; World Health Organization (WHO): Geneva, 2008.

The most significant sources and/or causes of Pb in drinking water include Pb service lines, faucets and fixtures with leaded brass, pipes with Pb solder, and adverse water chemistry.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016. Common sources of Cu, Sb, As, Cd, Cr, Se and Tl in drinking water include corrosion of household plumbing systems, erosion of natural deposits (Cu); discharges from petroleum refineries, fire retardants, ceramics, electronics and solder (Sb); erosion of natural deposits, runoff from orchards, runoff from glass and electronics production wastes (As); corrosion of galvanized pipes, erosion of natural deposits, discharge from metal refineries, and runoff from waste batteries and paints (Cd); discharge from steel and pulp mills, and erosion of natural deposits (Cr); discharge from petroleum and metal refineries, erosion of natural deposits and discharge from mines (Se); and leaching from ore-processing sites, discharge from electronics, glass and drug factories (Tl).55 United States Environmental Protection Agency (US EPA); National Primary Drinking Water Standards; US EPA, Office of Water: Washington, D.C., 2009. The United States Congress amended the Safe Drinking Water Act in 1986 to prohibit the use of pipes with more than 8% Pb, and solder or flux with more than 0.2% of Pb in their constitution. Effective January 2014, the Reduction of Lead in Drinking Water Act reduced the maximum allowable amount of this element from 8% to no more than a weighted average of 0.025% on a wetted surface.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016. Although the amount of Pb in infrastructure built after 1986 in the United States has been significantly reduced due to legislation, many schools were built prior to 1987 and may have Pb service lines, as well as building materials containing solder and flux with relatively high amounts of this element. Implementation of corrosion control practices, such as water treatment with orthophosphate (OrthoP), is capable of preventing leaching of Pb into drinking water.1111 Cartier, C.; Nour, S.; Richer, B.; Deshommes, E.; Prévost, M.; Water Res. 2012, 46, 5205. However, the amount of Pb (as well as Cu and other elements) found in an individual tap varies over time due to several parameters such as variation in the constitution of plumbing materials, plumbing age, water quality, sampling procedure (e.g., water stagnation time, and flow rate during sampling), water use, and temperature.1212 Masters, S.; Parks, J.; Atassi, A.; Edwards, M. A.; Environ. Monit. Assess. 2016, 188, 177.,1313 Boyd, G. R.; Pierson, G. L.; Kirmeyer, G. J.; English, R. J. ; J. - Am. Water Works Assoc. 2008, 100, 53.

Studies involving elemental analysis of school drinking water have been carried out in the United States,22 Lambrinidou, Y.; Triantafyllidou, S.; Edwards, M.; New Solutions: J. Environ. Occup. Health Policy 2010, 20, 25.,1414 Boyd, G. R.; Pierson, G. L.; Kirmeyer, G. J.; Britton, M. D.; English, R. J.; J. - Am. Water Works Assoc. 2008, 100, 105.,1515 Triantafyllidou, S.; Le, T.; Gallagher, D.; Edwards, M.; Sci. Total Environ. 2014, 466-467, 1011. Canada1616 Barn, P.; Nicol, A.-M.; Struck, S.; Dosanjh, S.; Li, R.; Kosatsky, T.; Environ. Health Rev. 2013, 56, 96.,1717 Doré, E.; Deshommes, E.; Andrews, R. C.; Nour, S.; Prévost, M.; Water Res. 2018, 140, 110. and Saudi Arabia,1818 Al-Saleh, I. A.; Sci. Total Environ. 1996, 181, 215. however, most of them focused on just Cu and Pb, or Pb alone. In one of these studies, concentrations of Al, Cd, Cu, Fe, Ni and Zn in school water coolers in Saudi Arabia were found to exceed the guideline values set by the European Economic Community.1818 Al-Saleh, I. A.; Sci. Total Environ. 1996, 181, 215. Spikes in drinking water concentration of Pb as high as 1,520, 1,600, and 13,000 µg L-1 were found in Washington D.C. Public Schools (DCPS), Seattle Public Schools (SPS), and schools in the Los Angeles Unified School District (LAUSD), respectively.22 Lambrinidou, Y.; Triantafyllidou, S.; Edwards, M.; New Solutions: J. Environ. Occup. Health Policy 2010, 20, 25.,1414 Boyd, G. R.; Pierson, G. L.; Kirmeyer, G. J.; Britton, M. D.; English, R. J.; J. - Am. Water Works Assoc. 2008, 100, 105.,1515 Triantafyllidou, S.; Le, T.; Gallagher, D.; Edwards, M.; Sci. Total Environ. 2014, 466-467, 1011. Results from these studies caused public alarm and negative media coverage leading to water remediation strategies such as implementing water filters, supplying consumers with bottled water, and removing Pb in plumbing to reduce potential accumulation of this metal in school children.22 Lambrinidou, Y.; Triantafyllidou, S.; Edwards, M.; New Solutions: J. Environ. Occup. Health Policy 2010, 20, 25.,1515 Triantafyllidou, S.; Le, T.; Gallagher, D.; Edwards, M.; Sci. Total Environ. 2014, 466-467, 1011. In the present work, tap water samples were collected from all 76 schools in the Winston-Salem/Forsyth County Schools (WSFCS) district (North Carolina, United States), which serves approximately 54,385 students. Samples were taken from cafeteria sinks and water fountains, as they may be some of the most used sources of drinking water in a given school. Inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) was used to determine the concentrations of eight elements (i.e., As, Cd, Cr, Cu, Pb, Sb, Se and Tl), and the results were compared with MCLs and ALs set by the EPA.

Multivariate analysis encompasses techniques to explore and analyze multivariate data in order to extract the maximum amount of signal from the noise and make inferences about the sources of the data.1919 Everitt, B. S.; Hothorn, T.; An Introduction to Applied Multivariate Analysis with R; Springer-Verlag: New York, 2011. This strategy has been extensively applied in environmental water research,2020 Krishna, A. K.; Satyanarayanan, M.; Govil, P. K.; J. Hazard. Mater. 2009, 167, 366.

21 Kumar, M.; Ramanathan, A.; Tripathi, R.; Farswan, S.; Kumar, D.; Bhattacharya, P.; Chemosphere 2017, 166, 135.

22 Wang, J.; Liu, G.; Liu, H.; Lam, P. K. S.; Sci. Total Environ. 2017, 583, 421.
-2323 Chen, K.; Jiao, J. J.; Huang, J.; Huang, R.; Environ. Pollut. 2007, 147, 771. and to study potable water systems in Greece and the United States.2424 Andra, S. S.; Makris, K. C.; Charisiadis, P.; Costa, C. N.; Environ. Monit. Assess. 2014, 186, 7307. A data driven approach was used, for example, after residential water testing in Flint (Michigan, USA) to develop machine learning models capable of predicting whether or not a given parcel data would have a Pb concentration above the EPA action level of 15 µg L-1.2525 Abernethy, J.; Anderson, C.; Dai, C.; Farahi, A.; Nguyen, L.; Rauh, A.; Schwartz, E.; Shen, W.; Shi, G.; Stroud, J.; Tan, X.; Webb, J.; Yang, S.; arXiv 2016, arXiv:1610.00580. Although widely used in many and diverse fields of research, multivariate analysis has yet to be evaluated as a tool to study trace elements in drinking water of an entire school district. In the present work, principal components analysis (PCA) and cluster analysis (CA) are applied to identify subtle patterns within the data and provide information that may be essential for preventive action programs on drinking water contamination in schools. In this case, school building age and the concentrations of eight trace elements in drinking water from cafeteria sinks and water fountains are used in PCA and CA. In an additional study, the effect of water stagnation during the summer break on Cu and Pb concentrations in the school's drinking water supply was also evaluated. Four schools, selected according to the age of the building, Pb concentration during the school year, and activity level over the summer break, were tested after 52 days of drinking water stagnation. The same taps tested during the school year were retested after the summer break, at five points throughout a 2 h flush period, to evaluate the effect of flushing on minimizing water contamination.

Experimental

Instrumentation

An Agilent 8800 ICP-MS/MS (Tokyo, Japan) was used to determine As, Cd, Cr, Cu, Pb, Sb, Se and Tl in drinking water at the mass-to-charge ratios (m/z) of 75, 111, 52, 63, 208, 121, 78 and 205, respectively. On-mass ICP-MS/MS was used in all determinations, with H2 gas flowing at 4 mL min-1 in the collision/reaction cell.2626 Fernández, S. D.; Sugishama, N.; Encinar, J. R.; Sanz-Medel, A.; Anal. Chem. 2012, 84, 5851. Instrumental parameters and optimized conditions for elemental analysis are listed in Table 1.

Table 1
ICP-MS/MS operating parameters used to determine trace element concentrations in drinking water

Reagents, standard reference solutions and samples

All samples and analytical solutions were prepared using trace-metal-grade nitric acid (Fisher, Pittsburgh, PA, USA) and distilled-deionized water (18 MΩ cm, Purelab Option-Q, Elga, Woodridge, IL, USA). Single-element stock solutions of As, Cd, Cr, Cu, Pb, Se, Sb and Tl (1000 mg L-1, SPEX CertPrep, Metuchen, NJ, USA) were used to prepare the calibration standards. The external standard calibration method was employed in all determinations. A certified reference material (Trace Elements in Water, NIST 1643e) from the National Institute of Standards and Technology (NIST, Gaithersburg, MD, USA) was used to check the method's accuracy. Water samples were directly analyzed, with dilutions performed when necessary to fit the calibration curve concentration range.

Sample collection

Tap water samples from cafeteria sinks and water fountains in all 76 schools of the WSFCS district were collected. Cafeteria sinks were chosen based on ease of access at the time of sampling and high usage. Water fountains were chosen based on location in high-traffic areas of the schools. Fountains located outside the main office were sampled in most cases. Sample collection took place during school activity hours (8:00 am-4:30 pm) between October 2016 and May 2017. Samples for the summer stagnation study were collected in August 2017. A P8 coarse filter paper (Fisher Scientific, Pittsburgh, PA, USA) and a plastic funnel were used to collect the samples into prewashed 50 mL conical polypropylene tubes (Thermo Scientific, Waltham, MA, USA), which were preloaded with 5 mL of 10% v v-1 HNO3. The collection tube was then filled up to the 50 mL mark with the drinking water sample, for a final acid concentration of 1% v v-1. Prior to sample collection, the plastic funnel and filter paper were conditioned with the respective water sample. All glassware and plastic ware used in this study were kept overnight in a 10% v v-1 HNO3 bath, and thoroughly rinsed with distilled-deionized water before use.

Data analysis

After comparing the results for all eight elements evaluated with their respective MCLs and ALs, the data were further investigated to identify schools that would be a priority regarding drinking water monitoring and potential contamination by toxic elements. The data were first analyzed to observe the proportions and patterns of data below the limits of detection (LODs), which are reported here, along with maximum and minimum values for each element. The data used to determine element concentration averages, as well as in multivariate analyses, were exclusive to elements presenting more than 50% of their results above the respective LODs. The expectation maximization algorithm (EM)2727 Dempster, A. P.; Laird, N. M.; Rubin, D. B.; J. R. Stat. Soc. B 1977, 39, 1. of log-ratio transformed data2828 Egozcue, J. J.; Pawlowsky-Glahn, V.; Mateu-Figueras, G.; Barcelo-Vidal, C.; Math. Geol. 2003, 35, 279. was used to impute values below the LOD for each element using the zCompositions package in R.2929 Palarea-Albaladejo, J.; Martín-Fernández, J. A.; Chemom. Intell. Lab. Syst. 2015, 143, 85. Model-based clustering was performed using the mclust package in R.3030 Scrucca, L.; Fop, M.; Murphy, T. B.; Raftery, A. E.; R J. 2016, 8, 289. Finite mixture models were developed using the EM algorithm,2828 Egozcue, J. J.; Pawlowsky-Glahn, V.; Mateu-Figueras, G.; Barcelo-Vidal, C.; Math. Geol. 2003, 35, 279. and the best model was selected according to the Bayesian information criterion (BIC).3131 McLachlan, G. J.; Rathnayake, S.; Wiley Interdiscip. Rev.: Data Min. Knowl. Discovery 2014, 4, 341. PCA was used as an exploratory and visual tool to uncover mutual relationships and correlations in the data. In this case, multivariate relationships are described in terms of complementary scores and loadings plots.3232 Wold, S.; Esbensen, K.; Geladi, P.; Chemom. Intell. Lab. Syst. 1987, 2, 37. Spatial representations of the data were performed using the ggmap package in R.3333 Kahle, D.; Wickham, H.; R J. 2013, 5, 144. All of the R code used in this study is available upon request.

Different vocabulary is used in the data mining community to refer to samples and variables. In this work, samples are referred to as observations, and variables are referred to as features. Therefore, the observations are the samples of drinking water, and the features include the concentrations of trace elements in drinking water and the school building construction year.

Results and Discussion

Trace element concentrations in schools' drinking water

The LODs, limits of quantification (LOQs) and percent recoveries from a certified reference material (CRM) are listed in Table 2 for As, Cd, Cr, Cu, Pb, Sb, Se and Tl. The LODs ranged from 0.004-0.3 µg L-1, and are significantly lower than the respective MCL and AL values set by the EPA (Table 3). The percent recoveries ranged from 87-98%. To further evaluate the accuracy of the method used in this work and compare it with that routinely used to assess water quality in the county, concentrations of Cu and Pb in 56 samples were also determined by the Winston-Salem water treatment plant laboratory (Winston-Salem, NC, USA). No statistically significant difference was observed between the results from the two laboratories by applying a two-sample t-test at the 95% confidence level.

Table 2
Limits of detection (LOD) and quantification (LOQ), and percent recoveries from a certified reference material of water (NIST 1643e) for As, Cd, Cr, Cu, Pb, Sb, Se and Tl determined by ICP-MS/MS
Table 3
Summary statistics for cafeteria and fountain drinking water samples, and maximum contaminant levels (MCL) or action levels (AL) set by the EPA

The water treatment plant in Winston-Salem uses OrthoP as a passivation chemical to prevent elemental leaching from pipes into the drinking water. For all occupied buildings evaluated in this study, and for both taps sampled, no element concentration exceeded the respective MCL or AL. Average values for all eight elements were at least 40-fold lower than the MCLs (Pb), and even the highest concentrations found were 3-fold (Pb) to more than 200-fold (Cr) lower than the MCL and AL values (Table 3).

Investigation of school buildings more likely to present elemental concentration spikes

As discussed earlier, drinking water contamination with toxic elements such as Pb is primarily a result of leaching from service lines, faucets and fixtures, which may be exacerbated by changes in the water chemistry.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016.,3434 Kennedy, C.; Yard, E.; Dignam, T.; Buchanan, S.; Condon, S.; Brown, M. J.; Raymond, J.; Rogers, H. S.; Sarisky, J.; de Castro, R.; Arias, I.; Breysse, P.; MMWR Morb. Mortal. Wkly. Rep. 2016, 65.,3535 https://www.michigan.gov/documents/snyder/FWATF_FINAL_REPORT_21March2016_517805_7.pdf, accessed in September 2018.
https://www.michigan.gov/documents/snyde...
In normal conditions, one may argue that the main source of drinking water contamination in a building is the materials used in its construction. Therefore, older buildings (especially those constructed before stricter legislation on building material safety was established)44 General Assembly of North Carolina; Schools/CC Facilities - Test Water for Lead, House Bill 1074; North Carolina General Assembly: Raleigh, 2016. may be more prone to element concentration spikes in their drinking water supply. In this context, we carried out a study to identify school buildings that would be more likely to present higher concentrations of the eight elements evaluated, and that should be more closely monitored for drinking water contamination. We applied a multivariate approach using PCA and CA to identify more nuanced patterns, involving not only the age of the building, but also trace element concentration data and geographical location. Considering the proposed new legislation requiring drinking water testing for Pb at elementary schools and day care facilities built before 1987,44 General Assembly of North Carolina; Schools/CC Facilities - Test Water for Lead, House Bill 1074; North Carolina General Assembly: Raleigh, 2016. this strategy may contribute to optimizing public resources. Water testing efforts may target the most “at risk” buildings more intensely, and potentially toxic elements other than Pb may also be monitored.

Summary statistics for all water samples analyzed are listed in Table 3. Figures S1 and S2 (Supplementary Information (SI) section) show the proportions of data below elemental LODs for cafeteria and fountain samples, respectively. For both taps, more than 50% of observations were below the LOD for Cd, Se and Tl. Therefore, these three features were discarded when determining means and when performing multivariate analyses. On the other hand, all observations had detectable levels of Cu and Sb. Thus, the statistics shown in Table 3 were calculated only for school building construction year, and As, Cr, Cu, Pb and Sb (i.e., elements for which less than 50% of the data were below the respective LODs). These same features were used in PCA and CA.

Figure 1 shows the results for a univariate analysis of data on trace element concentration values and the age of the school buildings. It lists the features correlation plots for cafeteria sink and water fountain observations. Significant correlations (p < 0.05) are the same for both taps: building year-Cr (negatively correlated), building year-As (positively correlated), and Cr-As (negatively correlated). A negative correlation between a given elemental concentration and building year implies that older buildings have a higher concentration of that element. Thus, older school buildings in this study present higher concentrations of Cr and lower concentrations of As in the drinking water, which is further confirmed by the negative correlation observed for As and Cr (Figure 1). On the other hand, newer school buildings show higher concentrations of As and lower concentrations of Cr in the drinking water. In addition to the As sources discussed earlier, it has been reported that this element readily absorbs onto solid iron surfaces that are part of an aqueous environment such as drinking water distribution systems (DWDS).3636 Jain, A.; Raven, K. P.; Loeppert, R. H.; Environ. Sci. Technol. 1999, 33, 1179.

37 Sun, X.; Doner, H. E.; Soil Sci. Soc. Am. J. 1998, 163, 278.

38 Manceau, A.; Geochim. Cosmochim. Acta 1995, 59, 3647.
-3939 Waychunas, G. A.; Fuller, C. C.; Rea, B. A.; Davis, J. A.; Geochim. Cosmochim. Acta 1996, 57, 2251. However, the As associated with Fe materials and other solids in the DWDS may vary and is difficult to predict,4040 Lytle, D. A.; Sorg, T. J.; Frietch, C.; Environ. Sci. Technol. 2004, 38, 5365. and further research is required to explain the relationships observed in this study. It is possible that the trends observed in Figure 1 for both As and Cr are related to the materials available at the time the school was built. Although these results may provide useful information for preventive policies associated with drinking water safety, the maximum concentrations found for As and Cr were more than 50-fold and 200-fold lower than the respective MCLs (Table 3).

Figure 1
Correlation matrices for the cafeteria sink and water fountain datasets. Insignificant correlations (p ≥ 0.05) are marked with crossed boxes.

Cafeteria sink and water fountain data were also independently evaluated using a multivariate approach. Data were standardized to a mean of 0 and a standard deviation of 1 for both sets of data. Model-based clustering was used to objectively classify the samples. The models were set to optimize parameters according to a user-specified number of groups. Multivariate analyses involving 1-5 sample groups were tested, and the most efficient interpretation of clustered data was achieved with four groups.

Figure 2 is a biplot of the scores and loadings for the first two principal components (PCs) after performing PCA on the standardized cafeteria sink data. Ellipses are drawn around observations according to cluster group assignment. Although there is some overlap amongst the four groups, clear patterns arise from the first two PCs. Considering the loading vectors, observations in group 2 separate according to As, Cu, Pb and Sb. Groups 1 and 3 separate according to the negative correlation between Cr and building year. Group 4 consists of observations with near zero scores in the first two PCs.

Figure 2
Biplot of the scores and loadings from the first two PCs after PCA of the standardized cafeteria sink dataset. Groups 1-4 are composed of 19, 14, 15 and 25 cafeteria sink samples, respectively.

Figure 3 shows the boxplots of standardized cafeteria sink data for each feature according to group assignment. The y-axis in this figure represents the distance from the mean in number of standard deviations. Group 1 consists of cafeteria sinks in newer school buildings, with relatively low concentrations of each element in drinking water, except for As. School buildings in group 2 have varied dates of construction, but present generally higher concentrations of As, Cu, Pb and Sb in drinking water when compared with the other groups. Groups 3 and 4 contain samples from older school buildings (all built before 1977). Samples in these groups present generally lower element concentrations than those in group 2, except for Cr in group 3.

Figure 3
Boxplots of standardized cafeteria sink data. The x-axis represents the sample group assignment after model-based clustering, and the y-axis represents the number of standard deviations from the mean.

The results in Figures 2 and 3 suggest that regulations introduced to limit the amount of toxic elements in building materials, combined with corrosion control treatments administered by the water treatment plant, were effective at reducing drinking water contamination. All school buildings in group 1, which present the lowest trace elements levels in drinking water, were built after 1986.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016. This observation is reinforced by the results in Figure 4, which shows the geographical distribution of the four groups of samples associated with the cafeteria sink dataset. Schools in group 1 tend to be outside the older main urban center of the school district (Winston-Salem, Figure 4). As the city grew over the years, so did the awareness of environmental risks related to trace elements, which resulted in cleaner construction materials and lower concentrations of toxic elements such as Pb in drinking water. On the other hand, it is interesting to note that the relationship between age of the building and level of trace elements in drinking water is not always direct, especially for construction periods before 1987. Most schools in the WSFCS district were built in 1920s (ca. 9% of the buildings), 1950s and 1960s (ca. 49% of the buildings), and 1990s and 2000s (ca. 33% of the buildings). Despite consisting of schools built before 1977, groups 3 and 4 present relatively low levels of most elements in drinking water when compared to the other groups. Alternatively, schools in group 2, with the highest trace elements levels in drinking water, have a spread of building ages (i.e., construction years between 1925 and 2009).

Figure 4
Geographical location of WSFCS school buildings according to group assignment after model-based clustering of cafeteria sink data. The background in this figure was prepared with Google Maps and includes Winston-Salem (36.099861ºN, 80.244217ºW) and neighboring towns in Forsyth County, NC, USA.

Similar results to those discussed for cafeteria sink were observed for water fountain samples (SI section, Figures S3-S5). Considering the multivariate analysis results for both taps, the approach employed in this study is more effective at identifying school buildings more prone to toxic element concentration spikes than solely relying on building construction date. It provides valuable information on location and the most critical elements for effective targeting in a public policy involving preventive action and drinking water safety in schools. Water samples collected from cafeteria sink and water fountain taps in group 2, for example, may be more susceptible to spikes in Pb concentration (for which the maximum value is only 3 times lower than the respective MCL, Table 3) due to periods of water stagnation or changes in water chemistry.3434 Kennedy, C.; Yard, E.; Dignam, T.; Buchanan, S.; Condon, S.; Brown, M. J.; Raymond, J.; Rogers, H. S.; Sarisky, J.; de Castro, R.; Arias, I.; Breysse, P.; MMWR Morb. Mortal. Wkly. Rep. 2016, 65.,3535 https://www.michigan.gov/documents/snyder/FWATF_FINAL_REPORT_21March2016_517805_7.pdf, accessed in September 2018.
https://www.michigan.gov/documents/snyde...

To further investigate the potential negative effects of water stagnation on Pb concentrations, we carried out a study with a school that was vacant for approximately 2 years (not included in the previous discussions and data), and confirmed a significant spike in Pb concentration in its drinking water (44 µg L-1 of Pb in a cafeteria sink sample). To remediate such high contamination level, we evaluated the effect of simply flushing the tap for a few minutes. After 5 min of flushing, Pb concentration was reduced to less than 1.0 µg L-1. The results of a similar study performed with four schools during the summer break is discussed in more detail in the next section.

Water stagnation during summer break and potential Cu and Pb concentration spikes in drinking water

Drinking water samples from four schools were retested after 52 days of summer break to evaluate the effect of water stagnation on Cu and Pb concentrations. These elements were chosen due to their importance in current water safety legislation.11 United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016. The schools were chosen according to Pb concentration in drinking water during the school year and the level of activity in the building during the summer. Considering these parameters and group assignment after multivariate analyses, we hypothesized that the cafeteria sink and water fountain at location C (Table 4) would be the taps most prone to spikes in Cu and Pb concentration. Locations A and B had summer activity. Location D is an old building with summer activity. Location C is an old building with no summer activity, and is part of group 2 (Figures 2 and 3, and S3 and S4 (SI section)), with a relatively higher Pb concentration during the school year.

Table 4
Concentrations of Cu and Pb in drinking water collected during the school year and after a 52-day summer break

As observed in Table 4, there was an increase in Pb concentration in drinking water for half of the cafeteria sinks evaluated. An even greater percentage of water fountains tested presented Pb concentration increase during the summer break (i.e., 3 out of 4 taps). As expected, samples from the cafeteria sink and water fountain in school location C (group 2, Figures 2 and 3, and S3 and S4 (SI section)) presented the highest concentrations of Pb after the summer break. Most results for Cu also showed an increase in concentration due to water flow stagnation. It is important to note that despite the spikes observed, no Cu nor Pb concentrations reached values above the respective MCLs.

Similar to the experiment previously described for the unoccupied school building, a flushing procedure was evaluated as a simple method to minimize element contamination due to water stagnation during the summer break. Figure 5 shows the concentration profiles for Cu and Pb during the flushing of each tap at location C. Similar results are observed for the other locations evaluated (Figure S6, SI section). For all but one spout there was a drop in Cu and Pb concentration after flushing for 5 min. Interestingly, Pb concentrations at the water fountain in school location C increased after 5 min, and only showed signs of reduction (compared to the original Pb concentration) after 1 h of flushing. A similar effect, although less pronounced, was observed for the cafeteria sink in location B (Figure S6, SI section). These results may be related to any combination of factors affecting sampling, which were discussed earlier. The water flow was held relatively constant during sampling at all taps, so the spikes in Pb concentration observed during the flushing procedure may be associated with inherent and random particulate release from Pb-containing materials at the school.1212 Masters, S.; Parks, J.; Atassi, A.; Edwards, M. A.; Environ. Monit. Assess. 2016, 188, 177.

Figure 5
Two-hour flushing profile for Cu and Pb concentration in drinking water from cafeteria sinks and water fountains in school location C after 52 days of summer break.

Conclusions

All samples collected from currently active schools in the WSFCS district tested below the MCL value set for each element (e.g., Pb values were all ≤ 5.0 µg L-1). Univariate analysis identified significant correlations (p < 0.05) between the age of the school building and concentrations of As and Cr in drinking water. CA and PCA identified four distinct groups of schools, which were separated according to the age of the building and the concentrations of trace elements in the drinking water. This strategy may be useful to water safety administrators, as resources can be focused on locations most likely to present concentration spikes due to water stagnation or changes in water chemistry.

The method described in the present study is applicable to other school districts. It may be used as a model for a broader water contamination prevention program, in which samples from each school would be frequently collected during a long period of time (e.g., once a month for one year), and the results from a multivariate analysis would identify priority schools. Finally, policy makers could set sampling frequency (once a month, once every three months, once a year, etc.) and identify the elements to be determined in drinking water for each school. The main advantage of such an approach is that it can be tailored to specific school districts, with each school tested at a frequency compatible with its contamination risk level.

The results presented in this study suggest that water stagnation does increase the chance of higher elemental concentrations in drinking water, especially Pb. They also indicate that a simple 5-60 min flushing procedure is capable of significantly minimizing water contamination due to flow stagnation in unoccupied or temporarily unused buildings. For example, a water sample with a Pb concentration of 2.3 µg L-1 during the school year reached a value of 4.2 µg L-1 after a 52-day stagnation period. However, after 5 min of flushing, the concentration at that tap (cafeteria sink at location C) dropped below 1.0 µg L-1 for Pb.

  • Supplementary Information
    Supplementary data are available free of charge at http://jbcs.sbq.org.br as a PDF file.

Acknowledgments

This work was supported by the National Science Foundation's Major Research Instrumentation Program (NSF MRI, grant CHE-1531698). We also thank the Department of Chemistry and the Graduate School of Arts and Sciences at Wake Forest University, as well as Alind Barany, Wayne Loflin, Darrell Walker, Larry Ragan and the Winston-Salem/Forsyth County Water Utility for their support.

References

  • 1
    United States Environmental Protection Agency (US EPA); Lead and Copper Rule Revisions White Paper; US EPA, Office of Water: Washington, D.C., 2016.
  • 2
    Lambrinidou, Y.; Triantafyllidou, S.; Edwards, M.; New Solutions: J. Environ. Occup. Health Policy 2010, 20, 25.
  • 3
    Katner, A.; Pieper, K. J.; Lambrinidou, Y.; Brown, K.; Hu, C.-Y.; Mielke, H. W.; Edwards, M. A.; Environ. Justice 2016, 9, 109.
  • 4
    General Assembly of North Carolina; Schools/CC Facilities - Test Water for Lead, House Bill 1074; North Carolina General Assembly: Raleigh, 2016.
  • 5
    United States Environmental Protection Agency (US EPA); National Primary Drinking Water Standards; US EPA, Office of Water: Washington, D.C., 2009.
  • 6
    Rosado, J. L.; Ronquillo, D.; Kordas, K.; Rojas, O.; Alatorre, J.; Lopez, P.; Garcia-Vargas, G.; Caamaño, M. C.; Cebrián, M. E.; Stoltzfus, R. J.; Environ. Health Perspect 2007, 115, 1371.
  • 7
    Tsai, S.-Y.; Chou, H.-Y.; The, H.-W.; Chen, C.-M.; Chen, C.-J.; NeuroToxicology 2003, 24, 747.
  • 8
    Rodríguez-Barranco, M.; Lacasaña, M.; Aguilar-Garduño, C.; Alguacil, J.; Gil, F.; González-Alzaga, B.; Rojas-García, A.; Sci. Total Environ 2013, 454-455, 562.
  • 9
    Council on Environmental Health; Pediatrics 2016, 138, e20161493.
  • 10
    World Health Organization (WHO); Guidelines for Drinking-Water Quality - Recommendations, vol. 1, 3rd ed.; World Health Organization (WHO): Geneva, 2008.
  • 11
    Cartier, C.; Nour, S.; Richer, B.; Deshommes, E.; Prévost, M.; Water Res 2012, 46, 5205.
  • 12
    Masters, S.; Parks, J.; Atassi, A.; Edwards, M. A.; Environ. Monit. Assess 2016, 188, 177.
  • 13
    Boyd, G. R.; Pierson, G. L.; Kirmeyer, G. J.; English, R. J. ; J. - Am. Water Works Assoc 2008, 100, 53.
  • 14
    Boyd, G. R.; Pierson, G. L.; Kirmeyer, G. J.; Britton, M. D.; English, R. J.; J. - Am. Water Works Assoc 2008, 100, 105.
  • 15
    Triantafyllidou, S.; Le, T.; Gallagher, D.; Edwards, M.; Sci. Total Environ 2014, 466-467, 1011.
  • 16
    Barn, P.; Nicol, A.-M.; Struck, S.; Dosanjh, S.; Li, R.; Kosatsky, T.; Environ. Health Rev 2013, 56, 96.
  • 17
    Doré, E.; Deshommes, E.; Andrews, R. C.; Nour, S.; Prévost, M.; Water Res 2018, 140, 110.
  • 18
    Al-Saleh, I. A.; Sci. Total Environ 1996, 181, 215.
  • 19
    Everitt, B. S.; Hothorn, T.; An Introduction to Applied Multivariate Analysis with R; Springer-Verlag: New York, 2011.
  • 20
    Krishna, A. K.; Satyanarayanan, M.; Govil, P. K.; J. Hazard. Mater 2009, 167, 366.
  • 21
    Kumar, M.; Ramanathan, A.; Tripathi, R.; Farswan, S.; Kumar, D.; Bhattacharya, P.; Chemosphere 2017, 166, 135.
  • 22
    Wang, J.; Liu, G.; Liu, H.; Lam, P. K. S.; Sci. Total Environ 2017, 583, 421.
  • 23
    Chen, K.; Jiao, J. J.; Huang, J.; Huang, R.; Environ. Pollut 2007, 147, 771.
  • 24
    Andra, S. S.; Makris, K. C.; Charisiadis, P.; Costa, C. N.; Environ. Monit. Assess 2014, 186, 7307.
  • 25
    Abernethy, J.; Anderson, C.; Dai, C.; Farahi, A.; Nguyen, L.; Rauh, A.; Schwartz, E.; Shen, W.; Shi, G.; Stroud, J.; Tan, X.; Webb, J.; Yang, S.; arXiv 2016, arXiv:1610.00580.
  • 26
    Fernández, S. D.; Sugishama, N.; Encinar, J. R.; Sanz-Medel, A.; Anal. Chem 2012, 84, 5851.
  • 27
    Dempster, A. P.; Laird, N. M.; Rubin, D. B.; J. R. Stat. Soc. B 1977, 39, 1.
  • 28
    Egozcue, J. J.; Pawlowsky-Glahn, V.; Mateu-Figueras, G.; Barcelo-Vidal, C.; Math. Geol 2003, 35, 279.
  • 29
    Palarea-Albaladejo, J.; Martín-Fernández, J. A.; Chemom. Intell. Lab. Syst 2015, 143, 85.
  • 30
    Scrucca, L.; Fop, M.; Murphy, T. B.; Raftery, A. E.; R J 2016, 8, 289.
  • 31
    McLachlan, G. J.; Rathnayake, S.; Wiley Interdiscip. Rev.: Data Min. Knowl. Discovery 2014, 4, 341.
  • 32
    Wold, S.; Esbensen, K.; Geladi, P.; Chemom. Intell. Lab. Syst 1987, 2, 37.
  • 33
    Kahle, D.; Wickham, H.; R J 2013, 5, 144.
  • 34
    Kennedy, C.; Yard, E.; Dignam, T.; Buchanan, S.; Condon, S.; Brown, M. J.; Raymond, J.; Rogers, H. S.; Sarisky, J.; de Castro, R.; Arias, I.; Breysse, P.; MMWR Morb. Mortal. Wkly. Rep. 2016, 65
  • 35
    https://www.michigan.gov/documents/snyder/FWATF_FINAL_REPORT_21March2016_517805_7.pdf, accessed in September 2018.
    » https://www.michigan.gov/documents/snyder/FWATF_FINAL_REPORT_21March2016_517805_7.pdf
  • 36
    Jain, A.; Raven, K. P.; Loeppert, R. H.; Environ. Sci. Technol. 1999, 33, 1179.
  • 37
    Sun, X.; Doner, H. E.; Soil Sci. Soc. Am. J. 1998, 163, 278.
  • 38
    Manceau, A.; Geochim. Cosmochim. Acta 1995, 59, 3647.
  • 39
    Waychunas, G. A.; Fuller, C. C.; Rea, B. A.; Davis, J. A.; Geochim. Cosmochim. Acta 1996, 57, 2251.
  • 40
    Lytle, D. A.; Sorg, T. J.; Frietch, C.; Environ. Sci. Technol. 2004, 38, 5365.

Publication Dates

  • Publication in this collection
    Mar 2019

History

  • Received
    26 June 2018
  • Accepted
    8 Oct 2018
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br