Acessibilidade / Reportar erro

Effects of Temperature and Concentration on the Determination of PET Viscosity

Abstract

This work describes the use of experiment planning to investigate the effects of the variables temperature and concentration of the polymer solution on the viscosity test of polyethylene terephthalate (PET). For this, the response surface methodology was based on a central composite rotatable design (CCRD) to optimize the combinations of the analytical conditions. With the analysis of the standard sample of PET with intrinsic viscosity of 0.630 ± 0.008 dL g-1 and 2-chlorophenol solvent, it was observed that the solution flow temperature and PET concentration caused significant effects on the results, while the storage temperature of the solvent was not statistically significant. With the results and the model developed, an industrial solid state polymerization process of PET was evaluated with simulations of the production of 30 tons of PET, demonstrating the importance of controlling the variables to guarantee the performance in quality control laboratories.

Keywords:
design of experiments; polyethylene terephthalate; viscosity


Introduction

Polymers are macromolecules obtained from the repetition of monomers in the process of polymerization. Polyethylene terephthalate (PET) was developed by the researchers Whinfield and Dickson in 1941,11 Whinfield, J. R. ; Dickson, J. T. ; US pat. 2,465,319, 1949. whose monomer can be synthesized by the direct esterification between terephthalic acid and ethylene glycol or transesterification between dimethyl terephthalate and ethylene glycol. In polymerization and solid state polymerization (SSP) steps for shaping the physicochemical properties of the material, certain process parameters must be continuously monitored to ensure product quality. 22 Mark, H. F. ; Bikales, N. M. ; Overberger, C. G. ; Menges, G. ; Kroschwitz, J. I. ; Polyesters to Polypeptide Synthesis, Encyclopedia of Polymer Science and Engineering, 2nd ed. ; Wiley-Interscience: New York, USA, 1988. The main characterization test of the resin and PET materials is the intrinsic viscosity (IV or [η]), in which the molar mass of the polymer is indirectly determined. 33 Chang, S. ; Sheu, M. F. ; Chen, S. M. ; J. Appl. Polym. Sci. 1983, 28, 3289.,44 Billmeyer, F. W. ; Textbook of Polymer Science, 3rd ed. ; John Wiley & Sons: New York, USA, 1984.

In industrial processes, the results of material characterization are used as reference for adjustments in the reactors, such as distribution of residence time, temperature, pressure and operating flow. 55 Yamada, T. ; Polym. J. 1992, 24, 43.

6 Fogler, H. S. ; Elementos de Engenharia das Reações Químicas, 4th ed. ; LTC: Rio de Janeiro, Brazil, 2009.

7 Madanhire, I. ; Mbohwa, C. ; Procedia CIRP 2016, 40, 580.
-88 Li, J. ; Papadopoulos, C. T. ; Zhang, L. ; Int. J. Prod. Res. 2016, 54, 6281.

Some statistical techniques and tools have been used in engineering studies for process optimization, such as the planning of experiments (design of experiments, DOE). When properly executed, this tool allows the management of people and projects and provides specific data for scientific and statistical application,99 Freeman, L. J. ; Ryan, A. G. ; Kensler, J. L. K. ; Dickinson, R. M. ; Vining, G. G. ; Qual. Eng. 2013, 25, 315. in addition to being used in the development or improvement of products and detection of the effects of variables on processes. 1010 Rodrigues, M. I. ; Iemma, A. F. ; Experimental Design and Process Optimization; CRC Press: New York, USA, 2015.,1111 Box, G. E. P. ; Hunter, J. S. ; Hunter, W. G. ; Statistics for Experimenters: Design, Innovation, and Discovery; John Wiley & Sons: New Jersey, USA, 2005.

Although the design of experiments is a powerful tool for statistical investigations, its application at an industrial level is still not widespread. However, in recent years, some cases reported by the literature instigate the possibility of introducing this statistical technique in a range of processes, as performed by Fukuda et al. 1212 Fukuda, I. M. ; Pinto, C. F. F. ; Moreira, C. S. ; Saviano, A. M. ; Lourenço, F. R. ; Braz. J. Pharm. Sci. 2018, 54, e01006. in the evaluation of quality control to obtain pharmaceutical compounds and Bowden et al. 1313 Bowden, G. D. ; Pichler, B. J. ; Maurer, A. ; Sci. Rep. 2019, 9, 11370. in the development and optimization of new radiochemical methods and the new synthesis of the PET tracker in copper-mediated radiofluorination (CMRF). Freitas et al. 1414 Freitas, F. L. S. ; Chinellato, A. C. ; Filho, E. R. P. ; Cruz, S. A. ; Polym. Test. 2020, 81, 106275. conducted a study, also using the design of experiments, to assess the effects of variables and stabilization additives in post-consumer PET, allowing simultaneous information to be obtained from the combination of the variables of interest.

Since the viscosity analysis of PET is dependent on variables with high sensitivity both in terms of control and in relation to the effects on the results, the requirements for performing the test need to be monitored to avoid detrimental deviations in industrial proportions. In summary, the temperature during the analysis and the polymer concentration in the diluted solution are essential factors for determining the viscosity. 1414 Freitas, F. L. S. ; Chinellato, A. C. ; Filho, E. R. P. ; Cruz, S. A. ; Polym. Test. 2020, 81, 106275.

For the analysis of improvement and quality control in an industry of recycled PET resin production, located in the city of Poços de Caldas (Brazil), a statistical investigation was proposed to evaluate the effects of the variables on the results of intrinsic viscosity. In order to optimize the research, an experimental planning was used in the experimental design and, as the aim of the study, it was evaluated to develop an analytical model to predict the intrinsic viscosity and to highlight the impacts from this test in the processing line in cases of errors during the execution of the analyses. For this study only the analytical effects of the laboratory were considered, since the intrinsic viscosity of the materials tested were constant. The aim of the research was to present the sensitivity of the polymer solution (PET plus solvent) under the evaluated conditions.

Experimental

Viscosity assay

Analyses of the intrinsic viscosity were performed according to ASTM D2857,1515 ASTM D2857: Standard Practice for Dilute Solution Viscosity of Polymers; ASTM International, West Conshohocken, PA, 2016. in which the polymer sample was dissolved in organic solvent and the relative viscosity (RV or hr) of this solution was analyzed relative to the pure solvent, using for this purpose a viscometer for the observation and measurement of the flow time. Relative viscosity can be converted to intrinsic viscosity by empirical models. In this work, the Billmeyer’s and Huggins’ model was adopted to perform this transformation. 1515 ASTM D2857: Standard Practice for Dilute Solution Viscosity of Polymers; ASTM International, West Conshohocken, PA, 2016.

16 Visakh, P. M. ; Liang, M. ; Poly(Ethylene Terephthalate) Based Blends, Composites and Nanocomposites; Elsevier: London, UK, 2015.
-1717 Billmeyer, F. W. ; J. Polym. Sci. 1949, 4, 83.

For conducting the analyses, a standard sample of PET resin was used, with intrinsic viscosity of 0.630 ± 0.008 dL g-1, previously dried in a convection oven at 120.0 ºC for 180 min (temperature for subsequent dissolution), and 2-chlorophenol (ortho-chlorophenol or OCP) with purity greater than 99% of the brand Sigma-Aldrich® (São Paulo, Brazil) as solvent for polymer dissolution. The solvent was stored in an amber bottle in an acrylic aquarium containing distilled water and PID (proportional, integral and derivative) temperature controller and the resin sample, in a hermetically sealed flask before drying.

Design of the experiments (DOE)

The standard condition of flow temperature, polymer concentration and storage temperature of the solvent were, respectively, 25.0 ºC, 8.000 g dL-1 and 25.0 ºC. Intervals of analysis were determined by means of central composite rotatable design (CCRD), shown in Table 1. 1010 Rodrigues, M. I. ; Iemma, A. F. ; Experimental Design and Process Optimization; CRC Press: New York, USA, 2015. The results were analyzed by the online software Protimiza Experimental Design. 1818 Rodrigues, M. I. ; Costa, P. ; Protimiza Experimental Design, v.1.0; Protimiza, Brazil, 2018.

Table 1
Independent variables and their levels for performing the assays

To evaluate the influence of the hygroscopicity of the PET resin on the weighing of material and due to the drying characteristics, moisture analysis was conducted in a convection oven for 180 min at 175.0 ºC. The model generated was validated with analyses of the standard in intermediate conditions, in order to promote a scan of the internal points and to allow the creation of adjustment factors in future experiments. 11 Whinfield, J. R. ; Dickson, J. T. ; US pat. 2,465,319, 1949.,1919 Lobo, H. ; Bonilla, J. V. ; Handbook of Plastics Analysis; Marcel Dekker: New York, USA, 2003.

20 Whitehead, B. D. ; Ind. Eng. Chem. Process Des. Dev. 1977, 16, 341.

21 Pó, R. ; Occhiello, E. ; Giannotta, G. ; Pelosin, L. ; Abis, L. ; Polym. Adv. Technol. 1996, 7, 365.

22 Zhi, L. T. ; Gao, Q. ; Nan, X. H. ; Sironi, C. ; J. Appl. Polym. Sci. 1995, 57, 473.

23 Hibbeler, R. C. ; Fluid Mechanics; Pearson Pumtke Hall: New York, USA, 2015.

24 Rosato, D. V. ; Rosato, D. V. ; Rosato, M. G. ; Injection Molding Handbook, 3rd ed. ; Springer Science Business Media: New York, USA, 2000.
-2525 Elamri, A. ; Abid, K. ; Harzallah, O. ; Lallam, A. ; Am. J. Nano Res. Appl. 2015, 3, 11.

Effects of intrinsic viscosity on the industrial process

For the application of the developed model, practical process simulations were carried out in an SSP industrial column of PET resin. Line feed consisted of amorphous PET resin from the extrusion of recycled PET flakes with intrinsic viscosity of 0.760 ± 0.030 dL g-1 and exit of crystallized PET resin with viscosity of 0.820 ± 0.030 dL g-1.

Solid state polymerization column consisted basically of a crystallizer, a dryer, solid state polymerization reactor with inert gas (nitrogen, N2) and the fluidized bed with air at atmospheric temperature (< 40.0 ºC) for cooling, and had the function of raising the molar mass of the polymer (and consequently the intrinsic viscosity) for molding carbonated beverage containers and eliminating by-products such as ethylene glycol and acetaldehyde. 11 Whinfield, J. R. ; Dickson, J. T. ; US pat. 2,465,319, 1949.,1919 Lobo, H. ; Bonilla, J. V. ; Handbook of Plastics Analysis; Marcel Dekker: New York, USA, 2003.

20 Whitehead, B. D. ; Ind. Eng. Chem. Process Des. Dev. 1977, 16, 341.

21 Pó, R. ; Occhiello, E. ; Giannotta, G. ; Pelosin, L. ; Abis, L. ; Polym. Adv. Technol. 1996, 7, 365.
-2222 Zhi, L. T. ; Gao, Q. ; Nan, X. H. ; Sironi, C. ; J. Appl. Polym. Sci. 1995, 57, 473.

A quality control laboratory evaluated the intrinsic viscosity of the PET inlet and outlet of the SSP process at 4 h intervals and only the material conforming to the appropriate specification was available for later commercialization. The daily production was 30 tons of post-condensed PET resin (1250 kg h-1). Figure 1 shows the simplified block diagram of the process.

Figure 1
Simplified block diagram of the solid state polymerization (SSP) process of the recycled PET resin.

With the validated model, the coefficients of the equation for the creation of a correction factor of emission of the results as a function of temperature were used, due to the facility of detecting their error in the execution of the analysis (for polymer concentration, the same could also be performed; however, the difficulty of perceiving the failure of this variable is greater because it is the first stage of the test).

Results and Discussion

Regression models for the responses

Table 2 shows the values and results of intrinsic viscosity of the adopted experimental design. To assure the results, the assays were performed in triplicate in each combination of the analytical conditions.

Table 2
Matrix of the experimental design to investigate the effects of temperature and concentration variables on the polyethylene terephthalate (PET) viscosity assay

Equation 1 expresses the model with the variables coded for viscosity determination, which was obtained using statistically significant parameters for p < 0.05. The terms that were not statistically significant were excluded from the model and added in the lack of fit for R-squared calculation. The coefficient determined was 99.62%, which in this case was classified as excellent.

(1) η = 0 . 630 0 . 017 x 1 + 0 . 050 x 2

where [η] is intrinsic viscosity.

It was verified that the model is of first order, linear and that the variable x3 (solvent storage temperature) was not statistically significant in the interval studied. Table 3 shows the analysis of variance (ANOVA) results for the [η], considering only the statistically significant terms. Based on the F-test, the model generated is more predictive and superior to the tabulated F (3.74). 1010 Rodrigues, M. I. ; Iemma, A. F. ; Experimental Design and Process Optimization; CRC Press: New York, USA, 2015.

Table 3
ANOVA of the polyethylene terephthalate (PET) viscosity assay

Figure 2 shows that the experimental points were distributed around the diagonal line, indicating the excellent performance of the model. The variation of relative deviations was small (< 10%), representing the good fit of the model to the analytical points. Therefore, the coded model of equation 1 was used to generate the response surfaces for viscosity.

Figure 2
Response surface and contour diagram for the PET intrinsic viscosity assay.

The analysis of the surface and response contour in Figure 2 indicates that the increase in temperature during flow and concentration of the polymer solution promoted an increase in intrinsic viscosity result, higher than the specification limit, while the storage temperature of the solvent only induced a deviation within the specified range of the standard sample used. The opposite effect is also observed in the viscosity with the decrease in the value of these variables.

The observed effects on viscosity due to flow temperature and polymer concentration have physical coherence. In liquid solutions, the viscosity is directly proportional to the force of attraction between molecules and, with increasing temperature, this force of attraction decreases, thus promoting the decrease of the resistance to flow. Thus, in liquids, the viscosity decreases with increasing temperature. 2323 Hibbeler, R. C. ; Fluid Mechanics; Pearson Pumtke Hall: New York, USA, 2015. However, the increase in polymer concentration in the solution causes the increase in viscosity, since the addition of new molecules promote intermolecular interactions that cause greater internal friction and consequent increase in the resistance to the flow. 1313 Bowden, G. D. ; Pichler, B. J. ; Maurer, A. ; Sci. Rep. 2019, 9, 11370.

Additionally to the study, other factors were analyzed. PET resin pellets are a hygroscopic material from the processing point of view, and material hydrolysis may occur at high temperatures due to the breakdown of ester molecules. In this specific case of the study, the moisture evaluation was related to the effects of sample mass. 2424 Rosato, D. V. ; Rosato, D. V. ; Rosato, M. G. ; Injection Molding Handbook, 3rd ed. ; Springer Science Business Media: New York, USA, 2000.

25 Elamri, A. ; Abid, K. ; Harzallah, O. ; Lallam, A. ; Am. J. Nano Res. Appl. 2015, 3, 11.
-2626 Fakirov, S. ; Handbook of Thermoplastic Polymers: Homopolymers, Copolymers, Blends, and Composites, vol. 1; Wiley-VCH Verlag GmbH: Weinheim, Germany, 2002. When amorphous, the humidity of PET resin can reach, on average, up to 0.35% m/m and, if crystallized, approximately 0.25% m/m. 1212 Fukuda, I. M. ; Pinto, C. F. F. ; Moreira, C. S. ; Saviano, A. M. ; Lourenço, F. R. ; Braz. J. Pharm. Sci. 2018, 54, e01006.,2020 Whitehead, B. D. ; Ind. Eng. Chem. Process Des. Dev. 1977, 16, 341.

21 Pó, R. ; Occhiello, E. ; Giannotta, G. ; Pelosin, L. ; Abis, L. ; Polym. Adv. Technol. 1996, 7, 365.

22 Zhi, L. T. ; Gao, Q. ; Nan, X. H. ; Sironi, C. ; J. Appl. Polym. Sci. 1995, 57, 473.

23 Hibbeler, R. C. ; Fluid Mechanics; Pearson Pumtke Hall: New York, USA, 2015.

24 Rosato, D. V. ; Rosato, D. V. ; Rosato, M. G. ; Injection Molding Handbook, 3rd ed. ; Springer Science Business Media: New York, USA, 2000.

25 Elamri, A. ; Abid, K. ; Harzallah, O. ; Lallam, A. ; Am. J. Nano Res. Appl. 2015, 3, 11.
-2626 Fakirov, S. ; Handbook of Thermoplastic Polymers: Homopolymers, Copolymers, Blends, and Composites, vol. 1; Wiley-VCH Verlag GmbH: Weinheim, Germany, 2002. As the sample weighing ranges were conventionally varied up to 0.001 g, the moisture content became an important and necessary variable to be quantified to evaluate the possible effects on the standard weighings, which could have a direct impact on the concentrations in order to extrapolate the established limit.

By performing the procedure for moisture determination in triplicate, an average value of 0.040 ± 0.009% m/m was obtained. Considering the range of variation of the weighings, the presented moisture content resulted in a mass variation below the maximum limit tolerated for the execution of the weighings, which in general minimized this variable with respect to possible analytical errors of the study. 2727 Ouchi, I. ; Hosoi, M. ; Tomie, T. ; Jpn. J. Appl. Phys. 1992, 31, 2505.,2828 Pirzadeh, E. ; Zadhoush, A. ; Haghighat, M. ; J. Appl. Polym. Sci. 2007, 106, 1544.

Although the developed model presented an excellent correlation among the analytical points, for a better application of the results and the conclusions inherent to the study, a validation step was performed with intermediate points.

Model validation

The validation of the model of analysis consisted in selecting intermediate conditions of the statistically significant variables (keeping the variable x3 in the central condition), predicting the value of intrinsic viscosity and comparison with the experimental result. Table 4 presents the tests performed and the relative deviations found.

Table 4
Validation results of the model for viscosity analysis

It was found that the overall relative deviation of the validation was < 1%, which was another indicative of the adequacy of the experimental points to the model generated.

It was decided to apply and determine the correction factor only for the variable flow temperature, since it can be monitored continuously during the analysis. However, polymer concentration may undergo diversified undesirable variations (weighing, solvent transfer and dissolution), which impedes the effective use of a correction element. Ranging between 23.3 and 26.7 ºC, the corresponding temperature correction codes were created between -1.68 and 1.68.

Equation 2, which contains the developed algebraic model, indicates that the coefficient related to the flow temperature is 0.017. Thus, when multiplied by any of the correction codes, it will result in a portion that must be added to or subtracted from the value of [η] found at the temperature of the corresponding level. This operation allows the acquisition of the normalized result at 25.0 ºC.

(2) η T = 25 . 0 ° C = η T = i + 0 . 017 L i

where [η]T=25.0ºC is the intrinsic viscosity normalized to 25.0 ºC, [η]T=i is the intrinsic viscosity with temperature flow i and Li is the corresponding level (positive or negative).

Due to the specificities of the molecular chain of PET, the validity of the developed model needs to be validated for other groups of PET family, mainly for industrial grade samples. 11 Whinfield, J. R. ; Dickson, J. T. ; US pat. 2,465,319, 1949.,1414 Freitas, F. L. S. ; Chinellato, A. C. ; Filho, E. R. P. ; Cruz, S. A. ; Polym. Test. 2020, 81, 106275.,2626 Fakirov, S. ; Handbook of Thermoplastic Polymers: Homopolymers, Copolymers, Blends, and Composites, vol. 1; Wiley-VCH Verlag GmbH: Weinheim, Germany, 2002. Thus, during model validation and comparison with production samples, the correlation between the studied parameters and the results with samples produced during processing were critically evaluated.

Effects on the SSP process

The process control in an SSP column should monitor parameters of temperature and polymer flow so that the adjustment of the molar mass (intrinsic viscosity) is in accordance with the specification and desired application, which relates mainly to the type of product to be stored in PET packaging. However, other variables also need to compose the control mesh, such as inert gas flow in the fluidized reactor, working pressure, degree of crystallization and residence time of the material. 55 Yamada, T. ; Polym. J. 1992, 24, 43.,2929 Kemkes, J. F. ; J. Polym. Sci. 1969, 22, 713.

In particular, the residence time distribution, which varies between 10 and 30 h according to the required product, is associated with the increase in PET viscosity and, for adjustments of this parameter, the regulation of the distribution may be effected from the viscosity results of the control laboratory in order to increase the process time in cases of viscosity below the lower specification limit. However, as an example of the studied process, errors of analysis can compromise an entire production period, since each result is obtained after 90 min at sampling intervals of 4 h, and the process adjustments cause immediate impacts due to continuous production. 11 Whinfield, J. R. ; Dickson, J. T. ; US pat. 2,465,319, 1949.

The daily analyses of the production were carried out purposely with flow temperature of 23.5 and 26.5 ºC. In parallel, the same analyses were also conducted at 25.0 ºC to guarantee the quality of the PET resin. To normalize the results at 25.0 ºC of the analyses out of this value, equation 2 and the temperature correction codes were used. Table 5 shows the results and normalizations performed.

Table 5
Temperature correction factor in the viscosity analysis of polyethylene terephthalate (PET) resin

A critical analysis of the results in Table 5 reflects significantly in the process. It should be emphasized that the analyzed period comprises a daily production of 30 tons of PET resin. If the results emitted by the laboratory had been at 23.5 ºC, the whole production would be segregated with a quality classification lower than the commercial standard (since in fact, the material would be under normal condition). As a side effect, unnecessary adjustments would be made to the process variables in order to achieve the specification. Analogously, at 26.5 ºC, even at the wrong temperature, the production would not be disqualified; however, there would be a margin for false adjustments that would result in process lack of control.

In industrial quality control laboratories, the present study can be used for monitoring reference of the analytical variables of the PET intrinsic viscosity assay, since this is the main parameter to characterize the resin during its processing and subsequent application. 3030 Ma, Y. ; Agarwal, U. S. ; Sikkema, D. J. ; Lemstra, P. J. ; Polymer 2003, 44, 4085. In the case of the runoff temperature of the test, it was noted that small deviations (on the order of 0.1 ºC) are already sufficient to cause a change in the viscosity measure of the sample under evaluation.

Conclusions

The use of experimental design was proven advantageous in the investigation of the effects of the variables temperature and concentration of polymer solution in the viscosity test of PET. It was possible to verify that the storage temperature of the solvent 2-chlorophenol was not statistically significant in the analyses (within the study range between 23.3 and 26.7 ºC), which indicates that if the solvent is in this thermal range there will be no significant deviations in the results. In this study it was found that the flow temperature and concentration of the polymer strongly impact the relative viscosity and consequently induces errors in reporting intrinsic viscosity.

Acknowledgments

This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), Brazil, finance code 001.

References

  • 1
    Whinfield, J. R. ; Dickson, J. T. ; US pat. 2,465,319, 1949
  • 2
    Mark, H. F. ; Bikales, N. M. ; Overberger, C. G. ; Menges, G. ; Kroschwitz, J. I. ; Polyesters to Polypeptide Synthesis, Encyclopedia of Polymer Science and Engineering, 2nd ed. ; Wiley-Interscience: New York, USA, 1988.
  • 3
    Chang, S. ; Sheu, M. F. ; Chen, S. M. ; J. Appl. Polym. Sci. 1983, 28, 3289.
  • 4
    Billmeyer, F. W. ; Textbook of Polymer Science, 3rd ed. ; John Wiley & Sons: New York, USA, 1984.
  • 5
    Yamada, T. ; Polym. J. 1992, 24, 43.
  • 6
    Fogler, H. S. ; Elementos de Engenharia das Reações Químicas, 4th ed. ; LTC: Rio de Janeiro, Brazil, 2009.
  • 7
    Madanhire, I. ; Mbohwa, C. ; Procedia CIRP 2016, 40, 580.
  • 8
    Li, J. ; Papadopoulos, C. T. ; Zhang, L. ; Int. J. Prod. Res. 2016, 54, 6281.
  • 9
    Freeman, L. J. ; Ryan, A. G. ; Kensler, J. L. K. ; Dickinson, R. M. ; Vining, G. G. ; Qual. Eng. 2013, 25, 315.
  • 10
    Rodrigues, M. I. ; Iemma, A. F. ; Experimental Design and Process Optimization; CRC Press: New York, USA, 2015.
  • 11
    Box, G. E. P. ; Hunter, J. S. ; Hunter, W. G. ; Statistics for Experimenters: Design, Innovation, and Discovery; John Wiley & Sons: New Jersey, USA, 2005.
  • 12
    Fukuda, I. M. ; Pinto, C. F. F. ; Moreira, C. S. ; Saviano, A. M. ; Lourenço, F. R. ; Braz. J. Pharm. Sci. 2018, 54, e01006.
  • 13
    Bowden, G. D. ; Pichler, B. J. ; Maurer, A. ; Sci. Rep. 2019, 9, 11370.
  • 14
    Freitas, F. L. S. ; Chinellato, A. C. ; Filho, E. R. P. ; Cruz, S. A. ; Polym. Test. 2020, 81, 106275.
  • 15
    ASTM D2857: Standard Practice for Dilute Solution Viscosity of Polymers; ASTM International, West Conshohocken, PA, 2016.
  • 16
    Visakh, P. M. ; Liang, M. ; Poly(Ethylene Terephthalate) Based Blends, Composites and Nanocomposites; Elsevier: London, UK, 2015.
  • 17
    Billmeyer, F. W. ; J. Polym. Sci. 1949, 4, 83.
  • 18
    Rodrigues, M. I. ; Costa, P. ; Protimiza Experimental Design, v.1.0; Protimiza, Brazil, 2018.
  • 19
    Lobo, H. ; Bonilla, J. V. ; Handbook of Plastics Analysis; Marcel Dekker: New York, USA, 2003.
  • 20
    Whitehead, B. D. ; Ind. Eng. Chem. Process Des. Dev. 1977, 16, 341.
  • 21
    Pó, R. ; Occhiello, E. ; Giannotta, G. ; Pelosin, L. ; Abis, L. ; Polym. Adv. Technol. 1996, 7, 365.
  • 22
    Zhi, L. T. ; Gao, Q. ; Nan, X. H. ; Sironi, C. ; J. Appl. Polym. Sci. 1995, 57, 473.
  • 23
    Hibbeler, R. C. ; Fluid Mechanics; Pearson Pumtke Hall: New York, USA, 2015.
  • 24
    Rosato, D. V. ; Rosato, D. V. ; Rosato, M. G. ; Injection Molding Handbook, 3rd ed. ; Springer Science Business Media: New York, USA, 2000.
  • 25
    Elamri, A. ; Abid, K. ; Harzallah, O. ; Lallam, A. ; Am. J. Nano Res. Appl. 2015, 3, 11.
  • 26
    Fakirov, S. ; Handbook of Thermoplastic Polymers: Homopolymers, Copolymers, Blends, and Composites, vol. 1; Wiley-VCH Verlag GmbH: Weinheim, Germany, 2002.
  • 27
    Ouchi, I. ; Hosoi, M. ; Tomie, T. ; Jpn. J. Appl. Phys. 1992, 31, 2505.
  • 28
    Pirzadeh, E. ; Zadhoush, A. ; Haghighat, M. ; J. Appl. Polym. Sci. 2007, 106, 1544.
  • 29
    Kemkes, J. F. ; J. Polym. Sci. 1969, 22, 713.
  • 30
    Ma, Y. ; Agarwal, U. S. ; Sikkema, D. J. ; Lemstra, P. J. ; Polymer 2003, 44, 4085.

Publication Dates

  • Publication in this collection
    19 Aug 2020
  • Date of issue
    Sept 2020

History

  • Received
    30 Dec 2019
  • Accepted
    07 May 2020
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br